986 resultados para Rapid test
Resumo:
A S. mansoni adult worm cDNA expression library was screened with sera from baboons in a early phase after infection. The clones that were positive with the early infection sera were examined for reactivity with pre-infection sera and heterologous infection sera. In order to discriminate a positive antibody reaction from the reactivity due to residual anti-E. coli antibodies, an unrelated cDNA clone was plated with the positive clone. The unrelated clone provided the negative background and the contrast necessary to discern a positive antibody reaction. In this way, we were able to eliminate selected clones that were positive with the pre-infection sera or heterologous infection sera. This characterization of the expression library clones enabled us to quickly target only clones with the desired pattern of antibody reactivity for sequencing, subcloning, and expressing
Resumo:
A survey for canine tegumentary leishmaniasis (CTL) has been carried out between 1986 and 1993 in seven endemic localities for American cutaneous leishmaniasis in the State of Rio de Janeiro. 270 dogs have been examined for their clinical aspects, the development of delayed hypersensitivity (DHS) with Immunoleish antigen and with immunofluorescent antibody research of IgG (IF). 28.2% of them had ulcer lesions and 3.3% had scars. The lesions consisted of single (39.5%) and mucocutaneous lesions (31.6%), multiple cutaneous (25.0%) and mucocutaneous lesions associated with cutaneous ulcers (4.0%). Twelve (15.8%) isolates from biopsies were analyzed by zimodeme and schizodeme and identified as L. (V.) braziliensis. The overall prevalence of canine infection that was evaluated with the skin test was of 40.5% and with IF it was of 25.5%. Both tests showed a high positive rate with relation to the animals with mucosal lesions, as in the case of human mucocutaneous leishmaniasis. The comparison of the two tests showed the skin test to have a better performance although there was no statistical difference (p>0.05) between them. The proportional sensitivity and specificity was of 84.0% and 74.0%, respectively. The Immunoleish skin test and IF are useful tools to be employed in CTL field epidemiological surveys.
Resumo:
Proteins secreted to the extracellular environment or to the periphery of the cell envelope, the secretome, play essential roles in foraging, antagonistic and mutualistic interactions. We hypothesize that arms races, genetic conflicts and varying selective pressures should lead to the rapid change of sequences and gene repertoires of the secretome. The analysis of 42 bacterial pan-genomes shows that secreted, and especially extracellular proteins, are predominantly encoded in the accessory genome, i.e. among genes not ubiquitous within the clade. Genes encoding outer membrane proteins might engage more frequently in intra-chromosomal gene conversion because they are more often in multi-genic families. The gene sequences encoding the secretome evolve faster than the rest of the genome and in particular at non-synonymous positions. Cell wall proteins in Firmicutes evolve particularly fast when compared with outer membrane proteins of Proteobacteria. Virulence factors are over-represented in the secretome, notably in outer membrane proteins, but cell localization explains more of the variance in substitution rates and gene repertoires than sequence homology to known virulence factors. Accordingly, the repertoires and sequences of the genes encoding the secretome change fast in the clades of obligatory and facultative pathogens and also in the clades of mutualists and free-living bacteria. Our study shows that cell localization shapes genome evolution. In agreement with our hypothesis, the repertoires and the sequences of genes encoding secreted proteins evolve fast. The particularly rapid change of extracellular proteins suggests that these public goods are key players in bacterial adaptation.
Resumo:
The persistence of agglutinins detected by MAT has created some problems to the interpretation of the results. The aim of this study was to examine the data of serology from 70 patients with serologically confirmed diagnosis of leptospirosis by during 3-13 months after being affected with leptospires in order to elucidate the interpretation of the persistence of agglutinins detected by MAT. Sixty-one patients sera (87.14%) had titers equal or greater than 800. Of these, two individuals maintained titers of 800 thirteen months after the onset. This study showed that only one sample of sera with high titers is not reliable to determine the time at which infection occurred.
Resumo:
The aim of this study was to validate the 14C-urea breath test for use in diagnosis of Helicobacter pylori infection. Thirty H. pylori positive patients, based on histologic test and thirty H. pylori negative patients by histology and anti-H. pylori IgG entered the study. Fasting patients drank 5 uCi of 14C-urea in 20 ml of water. Breath samples were collected at 0, 5, 10, 15, 20 and 30 min. The difference of cpm values between the two groups was significant at all the time intervals, besides time 0 (p<0.0001). At 20 min, the test gave 100% sensitivity and specificity with a cut-off value of 562 cpm. Females were higher expirers than males (p=0.005). 14C-urea breath test is highly accurate for Helicobacter pylori diagnosis. It is fast, simple and should be the non-invasive test used after treating Helicobacter pylori infection.
Resumo:
We compared the indirect immunofluorescence assay (IFA) with Western blot (Wb) as a confirmatory method to detect antibodies anti retrovirus (HIV-1 and HTLV-I/II). Positive and negative HIV-1 and HTLV-I/II serum samples from different risk populations were studied. Sensitivity, specificity, positive, negative predictive and kappa index values were assayed, to assess the IFA efficiency versus Wb. The following cell lines were used as a source of viral antigens: H9 ( HTLV-III b); MT-2 and MT-4 (persistently infected with HTLV-I) and MO-T (persistently infected with HTLV-II). Sensitivity and specificity rates for HIV-1 were 96.80% and 98.60% respectively, while predictive positive and negative values were 99.50% and 92.00% respectively. No differences were found in HIV IFA performance between the various populations studied. As for IFA HTLV system, the sensitivity and specificity values were 97.91% and 100% respectively with positive and negative predictive values of 100% and 97.92%. Moreover, the sensitivity of the IFA for HTLV-I/II proved to be higher when the samples were tested simultaneously against both antigens (HTLV-I-MT-2 and HTLV-II-MO-T). The overall IFA efficiency for HIV-1 and HTLV-I/II-MT-2 antibody detection probed to be very satisfactory with an excellent correlation with Wb (Kappa indexes 0.93 and 0.98 respectively). These results confirmed that the IFA is a sensitive and specific alternative method for the confirmatory diagnosis of HIV-1 and HTLV-I/II infection in populations at different levels of risk to acquire the infection and suggest that IFA could be included in the serologic diagnostic algorithm.
Resumo:
In the present study ELISA was standardized for the diagnosis of swine cysticercosis based on necropsy parameters and confirmed positive and negative control sera. Serum samples from pigs with other infections were also assayed to determine possible cross-reactions. Four antigens were assayed: from Taenia crassiceps vesicular fluid (VF-Tcra) and crude larvae extract (T-Tcra), and from Taenia solium extracts of scolex (S-Ts) and of larvae (T-Ts). A checkerboard evaluation of antigen, serum and conjugate dilutions, as well as the use of Tween-20 and skim cow milk in wash and blocking solution had a marked effect on improving ELISA performance. All the antigens showed a good performance, but VF-Tcra was the best, with 96.0% and 80.0% sensitivities for cut-offs respectively at 2sd and 3sd, and corresponding specificities of 97.5% and 100.0%. Cross-reactivity was observed only with hydatidosis and ascaridiosis. In view of the high performance observed, the ELISA test should be recommended for the diagnosis of cysticercosis in suspected swine in slaughterhouses and for the screening of cysticercosis in swine production. These results will support integrated measures of cysticercosis control throughout the chain of swine production, effectively contributing to public health.
Resumo:
Dissertation presented to obtain the Ph.D degree in Neuroscience Instituto de Tecnologia Química e Biológica, Universidade Nova de Lisboa
Resumo:
An epizootic outbreak of rabies occurred in 1995 in Ribeirão Preto, SP, with 58 cases of animal rabies (54 dogs, 3 cats and 1 bat) confirmed by the Pasteur Institute of São Paulo, and one human death. The need to provide care to a large number of people for the application of equine rabies immune globulin (ERIG) prevented the execution of the skin sensitivity test (SST) and often also the execution of desensitization, procedures routinely used up to that time at the Emergency Unit of the University Hospital of the Faculty of Medicine of Ribeirão Preto, University of São Paulo (EU-UHFMRP-USP), a reference hospital for the application of heterologous sera. In view of our positive experience of several years with the abolition of SST and of the use of premedication before the application of antivenom sera, we used a similar schedule for ERIG application. Of the 1489 victims of animal bites, 1054 (71%) received ERIG; no patient was submitted to SST and all received intravenously anti-histamines (anti-H1 + anti-H2) and corticosteroids before the procedure. The patients were kept under observation for 60 to 180 minutes and no adverse reaction was observed. On the basis of these results, since December 1995 ERIG application has been decentralized in Ribeirão Preto and has become the responsibility of the Emergency Unit of the University Hospital and the Central Basic Health Unit, where the same routine is used. Since then, 4216 patients have received ERIG (1818 at the Basic Health Unit and 2398 at the EU-UHFMRP), with no problems. The ideal would be the routine use of human rabies immune globulin (HRIG) in public health programs, but this is problematic, because of their high cost. However, while this does not occur, the use of SST is no longer justified at the time of application of ERIG, in view of the clinical evidence of low predictive value and low sensitivity of SST involving the application of heterologous sera. It is very important to point out that a negative SST result may lead the health team to a feeling of false safety that no adverse reaction will occur, but this is not true for the anaphylactoid reactions. The decision to use premedication, which is based on knowledge about anaphylaxis and on the pharmacology of the medication used, is left to the judgment of health professionals, who should always be prepared for eventual untoward events.
Resumo:
We have compared the searching of the presence of "honeycomb" structures by direct microscopy on wet mount preparations with the direct immunofluorescence (DIF) for the diagnosis of Pneumocystis carinii pneumonia (PCP) in 115 bronchoalveolar (BAL) fluids. The samples belonged to 115 AIDS patients; 87 with presumptive diagnosis of PCP and 28 with presumptive diagnosis other than PCP. The obtained results were coincident in 114 out of 115 studied samples (27 were positive and 87 negative) with both techniques. A higher percentage of positive results (32.18%) among patients with presumptive diagnosis of PCP with respect to those with presumptive diagnosis other than PCP (3.57%) was observed. One BAL fluid was positive only with DIF, showed scarce and isolated P. carinii elements and absence of typical "honeycomb" structures. The searching for "honeycomb" structures by direct microscopy on wet mount preparations could be considered as a cheap and rapid alternative for diagnosis of PCP when other techniques are not available or as screening test for DIF. This method showed a sensitivity close to DIF when it was applied to BAL fluids of AIDS patients with poor clinical condition and it was performed by an experienced microscopist.
Resumo:
The wide use of antibiotics in aquaculture has led to the emergence of resistant microbial species. It should be avoided/minimized by controlling the amount of drug employed in fish farming. For this purpose, the present work proposes test-strip papers aiming at the detection/semi-quantitative determination of organic drugs by visual comparison of color changes, in a similar analytical procedure to that of pH monitoring by universal pH paper. This is done by establishing suitable chemical changes upon cellulose, attributing the paper the ability to react with the organic drug and to produce a color change. Quantitative data is also enabled by taking a picture and applying a suitable mathematical treatment to the color coordinates given by the HSL system used by windows. As proof of concept, this approach was applied to oxytetracycline (OXY), one of the antibiotics frequently used in aquaculture. A bottom-up modification of paper was established, starting by the reaction of the glucose moieties on the paper with 3-triethoxysilylpropylamine (APTES). The so-formed amine layer allowed binding to a metal ion by coordination chemistry, while the metal ion reacted after with the drug to produce a colored compound. The most suitable metals to carry out such modification were selected by bulk studies, and the several stages of the paper modification were optimized to produce an intense color change against the concentration of the drug. The paper strips were applied to the analysis of spiked environmental water, allowing a quantitative determination for OXY concentrations as low as 30 ng/mL. In general, this work provided a simple, method to screen and discriminate tetracycline drugs, in aquaculture, being a promising tool for local, quick and cheap monitoring of drugs.
Resumo:
Sulfadiazine is an antibiotic of the sulfonamide group and is used as a veterinary drug in fish farming. Monitoring it in the tanks is fundamental to control the applied doses and avoid environmental dissemination. Pursuing this goal, we included a novel potentiometric design in a flow-injection assembly. The electrode body was a stainless steel needle veterinary syringe of 0.8-mm inner diameter. A selective membrane of PVC acted as a sensory surface. Its composition, the length of the electrode, and other flow variables were optimized. The best performance was obtained for sensors of 1.5-cm length and a membrane composition of 33% PVC, 66% onitrophenyloctyl ether, 1% ion exchanger, and a small amount of a cationic additive. It exhibited Nernstian slopes of 61.0 mV decade-1 down to 1.0×10-5 mol L-1, with a limit of detection of 3.1×10-6 mol L-1 in flowing media. All necessary pH/ionic strength adjustments were performed online by merging the sample plug with a buffer carrier of 4-(2-hydroxyethyl)-1-piperazineethanesulfonic acid, pH 4.9. The sensor exhibited the advantages of a fast response time (less than 15 s), long operational lifetime (60 days), and good selectivity for chloride, nitrite, acetate, tartrate, citrate, and ascorbate. The flow setup was successfully applied to the analysis of aquaculture waters. The analytical results were validated against those obtained with liquid chromatography–tandem mass spectrometry procedures. The sampling rate was about 84 samples per hour and recoveries ranged from 95.9 to 106.9%.