846 resultados para Radio-frequency power
Resumo:
The objective of this longitudinal study, conducted in a neonatal intensive care unit, was to characterize the response to pain of high-risk very low birth weight infants (<1,500 g) from 23 to 38 weeks post-menstrual age (PMA) by measuring heart rate variability (HRV). Heart period data were recorded before, during, and after a heel lanced or wrist venipunctured blood draw for routine clinical evaluation. Pain response to the blood draw procedure and age-related changes of HRV in low-frequency and high-frequency bands were modeled with linear mixed-effects models. HRV in both bands decreased during pain, followed by a recovery to near-baseline levels. Venipuncture and mechanical ventilation were factors that attenuated the HRV response to pain. HRV at the baseline increased with post-menstrual age but the growth rate of high-frequency power was reduced in mechanically ventilated infants. There was some evidence that low-frequency HRV response to pain improved with advancing PMA.
Resumo:
Recent findings in the field of biomaterials and tissue engineering provide evidence that surface immobilised growth factors display enhanced stability and induce prolonged function. Cell response can be regulated by material properties and at the site of interest. To this end, we developed scaffolds with covalently bound vascular endothelial growth factor (VEGF) and evaluated their mitogenic effect on endothelial cells in vitro. Nano- (254±133 nm) or micro-fibrous (4.0±0.4 μm) poly(ɛ-caprolactone) (PCL) non-wovens were produced by electrospinning and coated in a radio frequency (RF) plasma process to induce an oxygen functional hydrocarbon layer. Implemented carboxylic acid groups were converted into amine-reactive esters and covalently coupled to VEGF by forming stable amide bonds (standard EDC/NHS chemistry). Substrates were analysed by X-ray photoelectron spectroscopy (XPS), enzyme-linked immuno-assays (ELISA) and immunohistochemistry (anti-VEGF antibody and VEGF-R2 binding). Depending on the reaction conditions, immobilised VEGF was present at 127±47 ng to 941±199 ng per substrate (6mm diameter; concentrations of 4.5 ng mm(-2) or 33.3 ng mm(-2), respectively). Immunohistochemistry provided evidence for biological integrity of immobilised VEGF. Endothelial cell number of primary endothelial cells or immortalised endothelial cells were significantly enhanced on VEGF-functionalised scaffolds compared to native PCL scaffolds. This indicates a sustained activity of immobilised VEGF over a culture period of nine days. We present a versatile method for the fabrication of growth factor-loaded scaffolds at specific concentrations.
Resumo:
Cardiac tissue engineering approaches can deliver large numbers of cells to the damaged myocardium and have thus increasingly been considered as a possible curative treatment to counteract the high prevalence of progressive heart failure after myocardial infarction (MI). Optimal scaffold architecture and mechanical and chemical properties, as well as immune- and bio-compatibility, need to be addressed. We demonstrated that radio-frequency plasma surface functionalized electrospun poly(ɛ-caprolactone) (PCL) fibres provide a suitable matrix for bone-marrow-derived mesenchymal stem cell (MSC) cardiac implantation. Using a rat model of chronic MI, we showed that MSC-seeded plasma-coated PCL grafts stabilized cardiac function and attenuated dilatation. Significant relative decreases of 13% of the ejection fraction (EF) and 15% of the fractional shortening (FS) were observed in sham treated animals; respective decreases of 20% and 25% were measured 4 weeks after acellular patch implantation, whereas a steadied function was observed 4 weeks after MSC-patch implantation (relative decreases of 6% for both EF and FS).
Resumo:
In studies assessing outdoor range use of laying hens, the number of hens seen on outdoor ranges is inversely correlated to flock size. The aim of this study was to assess individual ranging behavior on a covered (veranda) and an uncovered outdoor run (free-range) in laying hen flocks varying in size. Five to ten percent of hens (aged 9–15 months) within 4 small (2–2500 hens), 4 medium (5–6000), and 4 large (≥9000) commercial flocks were fitted with radio frequency identification (RFID) tags. Antennas were placed at both sides of all popholes between the house and the veranda and the veranda and the free-range. Ranging behavior was directly monitored for approximately three weeks in combination with hourly photographs of the free-range for the distribution of hens and 6h long video recordings on two parts of the free-range during two days. Between 79 and 99% of the tagged hens were registered on the veranda at least once and between 47 and 90% were registered on the free-range at least once. There was no association between the percentage of hens registered outside the house (veranda or free-range) and flock size. However, individual hens in small and medium sized flocks visited the areas outside the house more frequently and spent more time there than hens from large flocks. Foraging behavior on the free-range was shown more frequently and for a longer duration by hens from small and medium sized flocks than by hens from large flocks. This difference in ranging behavior could account for the negative relationship between flock size and the number of hens seen outside at one point of time. In conclusion, our work describes individual birds’ use of areas outside the house within large scale commercial egg production.
Resumo:
BACKGROUND: Several parameters of heart rate variability (HRV) have been shown to predict the risk of sudden cardiac death (SCD) in cardiac patients. There is consensus that risk prediction is increased when measuring HRV during specific provocations such as orthostatic challenge. For the first time, we provide data on reproducibility of such a test in patients with a history of acute coronary syndrome. METHODS: Sixty male patients (65+/-8years) with a history of acute coronary syndrome on stable medication were included. HRV was measured in supine (5min) and standing (5min) position on 2 occasions separated by two weeks. For risk assessment relevant time-domain [standard deviation of all R-R intervals (SDNN) and root mean squared standard differences between adjacent R-R intervals (RMSSD)], frequency domain [low-frequency power (LF), high-frequency power (HF) and LF/HF power ratio] and short-term fractal scaling component (DF1) were computed. Absolute reproducibility was assessed with the standard errors of the mean (SEM) and 95% limits of random variation, and relative reproducibility by the intraclass correlation coefficient (ICC). RESULTS: We found comparable SEMs and ICCs in supine position and after an orthostatic challenge test. All ICCs were good to excellent (ICCs between 0.636 and 0.869). CONCLUSIONS: Reproducibility of HRV parameters during orthostatic challenge is good and comparable with supine position.
Resumo:
PURPOSE: Exercise-related sudden cardiac deaths (SCD) occur with a striking male predominance. A higher sympathetic tone in men has been suggested as risk factor for SCD. Elite athletes have the highest risk for exercise-related SCD. We aimed to analyze the autonomic nervous system of elite cross-country skiers from Norway, Russia and Switzerland in supine position and after orthostatic challenge in various training periods (TP). METHOD: Measurements of heart rate variability (HRV) were performed on a weekly basis over 1 year using an orthostatic challenge test with controlled breathing. Main outcome parameters were the high-frequency power in supine position (HFsupine) as marker of cardiac parasympathetic activity and the low-frequency/high-frequency power ratio after orthostatic challenge (LF/HFstand) as marker of cardiac sympathetic activation. Training intensity and duration were recorded daily and expressed as training strain. The training year was divided into three TPs. An average of weekly HRV measurements was calculated for each TP. RESULT: Female (n = 19, VO2max 62.0 +/- 4.6 ml kg(-1) min(-1), age 25.8 +/- 4.3 years) and male (n = 16, VO2max 74.3 +/- 6.3 ml kg(-1) min(-1), age 24.4 +/- 4.2 years) athletes were included. Training strain was comparable between sexes (all p > 0.05) and changed between TPs (all p < 0.05) while no HRV parameters changed over time. There were no sex differences in HFsupine while the LF/HFstand was significantly higher in male athletes in all TPs. CONCLUSION: For a comparable amount of training, male athletes showed constantly higher markers of sympathetic activity after a provocation maneuver. This may explain part of the male predominance in sports-related SCD.
Resumo:
Accurate assessments of fish populations are often limited by re-observation or recapture events. Since the early 1990s, passive integrated transponders (PIT tags) have been used to understand the biology of many fish species. Until recently, PIT applications in small streams have been limited to physical recapture events. To maximize recapture probability, we constructed PIT antenna arrays in small streams to remotely detect individual fish. Experiences from two different laboratories (three case studies) allowed us to develop a unified approach to applying PIT technology for enhancing data assessments. Information on equipment, its installation, tag considerations, and array construction is provided. Theoretical and practical definitions are introduced to standardize metrics for assessing detection efficiency. We demonstrate how certain conditions (stream discharge, vibration, and ambient radio frequency noise) affect the detection efficiency and suggest that by monitoring these conditions, expectations of efficiency can be modified. We emphasize the importance of consistently estimating detection efficiency for fisheries applications.
Resumo:
A medical cyclotron accelerating H- ions to 18 MeV is in operation at the Bern University Hospital (Inselspital). It is the commercial IBA 18/18 cyclotron equipped with a specifically conceived 6 m long external beam line ending in a separate bunker. This feature is unique for a hospital-based facility and makes it possible to conduct routine radioisotope production for PET diagnostics in parallel with multidisciplinary research activities, among which are novel particle detectors, radiation biophysics, radioprotection, radiochemistry and radiopharmacy developments. Several of these activities, such as radiobiology experiments for example, require low current beams down to the pA range, while medical cyclotrons are designed for high current operation above 10 μA. In this paper, we present the first results on the low current performance of a PET medical cyclotron obtained by ion source, radio-frequency and main coil tuning. With this method, stable beam currents down to (1.5+/- 0.5 ) pA were obtained and measured with a high-sensitivity Faraday cup located at the end of the beam transport line.
Resumo:
In this paper, we propose a particle filtering (PF) method for indoor tracking using radio frequency identification (RFID) based on aggregated binary measurements. We use an Ultra High Frequency (UHF) RFID system that is composed of a standard RFID reader, a large set of standard passive tags whose locations are known, and a newly designed, special semi-passive tag attached to an object that is tracked. This semi-passive tag has the dual ability to sense the backscatter communication between the reader and other passive tags which are in its proximity and to communicate this sensed information to the reader using backscatter modulation. We refer to this tag as a sense-a-tag (ST). Thus, the ST can provide the reader with information that can be used to determine the kinematic parameters of the object on which the ST is attached. We demonstrate the performance of the method with data obtained in a laboratory environment.
Resumo:
We report on the fabrication details of TES based on Mo/Au bilayers. The Mo layer is deposited by radio frequency (RF) sputtering and capped with a sputter deposited thin Au protection layer. Afterwards, a second Au layer of suitable (lower) resistivity is deposited ex‐situ by e‐beam evaporation, until completion of the total desired Au thickness. The deposition was performed at room temperature (RT) on LPCVD Si3 N4 membranes. Such a deposition procedure is very reproducible and allow controlling the critical temperature (Tc) and normal electrical resistance (RN ) of the Mo/Au bilayer. The process is optimized to achieve low stress bilayers, thus avoiding the undesirable curvature of the membranes. Bilayers are patterned using photolithographic techniques and wet etching procedures. Mo superconducting paths are used to contact the Mo/Au bilayers, thus ensuring good electrical conductivity and thermal isolation. The entire fabrication process let to stable and reproducible sensors with required and tunable functional properties
Resumo:
This paper presents a microinverter to be integrated into a solar module. The proposed solution combines a forward converter and a constant off-time boundary mode control, providing MPPT capability and unity power factor in a single-stage converter. The transformer structure of the power stage remains as in the classical DC-DC forward converter. Transformer primary windings are utilized for power transfer or demagnetization depending on the grid semi-cycle. Furthermore, bidirectional switches are used on the secondary side allowing direct connection of the inverter to the grid. Design considerations for the proposed solution are provided, regarding the inductance value, transformer turns ratio and frequency variation during a line semi-cycle. The decoupling of the twice the line frequency power pulsation is also discussed, as well as the maximum power point tracking (MPPT) capability. Simulation and experimental results for a 100W prototype are enclosed
Resumo:
Este Proyecto Fin de Carrera trata sobre el estudio de la precisión de los modelos de transistores de radiofrecuencia y el efecto que la misma produce en un circuito real, como es la variabilidad de diversas magnitudes tales como la ganancia y el punto de compresión a 1 decibelio. Para ello se ha construido un circuito de pruebas que ha sido sometido a diversas simulaciones y sobre el que se han realizado numerosas medidas que han sido analizadas mediante software de análisis estadístico. This Final Year Project is about the study of the precision of models of radio frequency transistors and the effect it produces in a real circuit, as is the variability of various magnitudes such as gain and one‐decibel compression point. For this we have built a test circuit that has been subjected to various simulations and on which there have been numerous measures that have been analyzed by statistical analysis software.
Resumo:
In recent years, spacial agencies have shown a growing interest in optical wireless as an alternative to wired and radio-frequency communications. The use of these techniques for intra-spacecraft communications reduces the effect of take-off acceleration and vibrations on the systems by avoiding the need for rugged connectors and provides a significant mass reduction. Diffuse transmission also eases the design process as terminals can be placed almost anywhere without a tight planification to ensure the proper system behaviour. Previous studies have compared the performance of radio-frequency and infrared optical communications. In an intra-satellite environment optical techniques help reduce EMI related problems, and their main disadvantages - multipath dispersion and the need for line-of-sight - can be neglected due to the reduced cavity size. Channel studies demonstrate that the effect of the channel can be neglected in small environments if data bandwidth is lower than some hundreds of MHz.
Resumo:
Intraoral devices for bite-force sensing have several applications in odontology and maxillofacial surgery, as bite-force measurements provide additional information to help understand the characteristics of bruxism disorders and can also be of help for the evaluation of post-surgical evolution and for comparison of alternative treatments. A new system for measuring human bite forces is proposed in this work. This system has future applications for the monitoring of bruxism events and as a complement for its conventional diagnosis. Bruxism is a pathology consisting of grinding or tight clenching of the upper and lower teeth, which leads to several problems such as lesions to the teeth, headaches, orofacial pain and important disorders of the temporomandibular joint. The prototype uses a magnetic field communication scheme similar to low-frequency radio frequency identification (RFID) technology (NFC). The reader generates a low-frequency magnetic field that is used as the information carrier and powers the sensor. The system is notable because it uses an intra-mouth passive sensor and an external interrogator, which remotely records and processes information regarding a patient?s dental activity. This permits a quantitative assessment of bite-force, without requiring intra-mouth batteries, and can provide supplementary information to polysomnographic recordings, current most adequate early diagnostic method, so as to initiate corrective actions before irreversible dental wear appears. In addition to describing the system?s operational principles and the manufacture of personalized prototypes, this report will also demonstrate the feasibility of the system and results from the first in vitro and in vivo trials.
Resumo:
This work is related to the improvement of the output impedance of the Buck converter by means of introducing an additional power path that virtually increases the output capacitance during transients. It is well known that in VRM applications, with wide load steps, voltage overshoots and undershoots may lead to undesired performance of the load. To solve this problem, high-bandwidth high-switching frequency power converters can be applied to reduce the transient time or a big output capacitor can be applied to reduce the output impedance. The first solution can degrade the efficiency by increasing switching losses of the MOSFETS, and the second solution is penalizing the cost and size of the output filter. The Output Impedance Correction Circuit (OICC), as presented here, is used to inject or extract a current n-1 times larger than the output capacitor current, thus virtually increasing n times the value of the output capacitance during the transients. This feature allows the usage of a low frequency Buck converter with smaller capacitor but satisfying the dynamic requirements.