994 resultados para Preliminary Observations
Resumo:
A newly opened excavation in the Cassina beds of the Lower Meride Limestone (Monte San Giorgio UNESCO WHL, Canton Ticino, Southern Alps) has yielded a small collection of Ladinian plant fossils, together with vertebrate (mostly fish) and invertebrate remains The flora contains at least five species, conifer remains assignable to the genera Elatocladus, Voltzia and Pelourdea are the most common elements A new species, Elatocladus cassinae n Sp, is formally, described Co-occurring with the conifers arc seed ferns (Ptilozamites) and a few putative cycadalean remains (Taemopteris) Among the identified genera, only Volizia has previously been reported from Monte San Giorgio The fossils presented in this paper indicate that a diversified flora thrived in the region during the Ladman Floral composition and preservation patterns are suggestive of a taphonomically-biased record and a relatively far-away source area
Resumo:
PURPOSE Inotuzumab ozogamicin (CMC-544) is an antibody-targeted chemotherapy agent composed of a humanized anti-CD22 antibody conjugated to calicheamicin, a potent cytotoxic agent. This was a phase I study to determine the maximum-tolerated dose (MTD), safety, and preliminary efficacy of inotuzumab ozogamicin in an expanded MTD cohort of patients with relapsed or refractory CD22(+) B-cell non-Hodgkin's lymphoma (NHL). PATIENTS AND METHODS Inotuzumab ozogamicin was administered intravenously as a single agent once every 3 or 4 weeks at doses ranging from 0.4 to 2.4 mg/m(2). Outcomes included MTD, safety, pharmacokinetics, response, progression-free survival (PFS), and overall survival. Results Seventy-nine patients were enrolled. The MTD was determined to be 1.8 mg/m(2). Common adverse events at the MTD were thrombocytopenia (90%), asthenia (67%), and nausea and neutropenia (51% each). The objective response rate at the end of treatment was 39% for the 79 enrolled patients, 68% for all patients with follicular NHL treated at the MTD, and 15% for all patients with diffuse large B-cell lymphoma treated at the MTD. Median PFS was 317 days (approximately 10.4 months) and 49 days for patients with follicular NHL and diffuse large B-cell lymphoma, respectively. CONCLUSION Inotuzumab ozogamicin has demonstrated efficacy against CD22(+) B-cell NHL, with reversible thrombocytopenia as the main toxicity.
Resumo:
INTRODUCTION. NAVA is a new spontaneous-assisted ventilatory mode based on thedetection of diaphragmatic electrical activity (Eadi) and its feedback to adjust ventilatorsettings. NAVA uses the Eadi, an expression of the respiratory center's activity, to initiatepressurization, set the level of pressure support and cycle the ventilator into exhalation.Therefore, NAVA should theoretically allow near-perfect synchronization between the patientand the ventilator. However there are few data documenting these effects in intensive carepatients.OBJECTIVES. To determine whether NAVA can improve patient-ventilator synchronycompared to standard pressure support (PS) in intubated intensive care patients.METHODS. Comparative study of patient-ventilator interaction during PS with cliniciandetermined ventilator settings and NAVA with NAVA gain (proportionality factor betweenEadi and the amount of delivered inspiratory pressure) set as to obtain the same peak airwaypressure as the total pressure obtained in PS. A 20 min continuous recording with eachventilatory mode was performed allowing determination of trigger delay (Td), patient neuralinspiratory time (Tin), duration of pressurization by the ventilator (Tiv), excess durationof pressurization (Ti excess = Tiv - Tin/Tin 9 100) and number of asynchrony events byminute: non-triggering breaths, auto-triggering, double triggering, premature and delayedcycling.Results are given in mean ± SD. p is considered significant if\0.05.RESULTS. Preliminary results (mean ± SD): five patients (age 75 ± 12 years, 1 M/4F,BMI 25.7 ± 4.1 kg m-2), two pts with COPD, 1 with restrictive disease, initial settings: PS14.6 ± 1.7 cm H2O, PEEP 6.4 ± 1.5 cm H2O, NAVA gain 2.8 ± 1.3PS NAVA % reduction NAVAversus PSTd (ms) 210.4 ± 63.0 51.8 ± 12.1* 74.5 ± 5.0Ti excess (%) 12.9 ± 19.6 2.2 ± 0.6 70.8 ± 37.8n asynchrony/minute 7.6 ± 6.4 4.1 ± 3.7* 47.5 ± 17.0Respiratory rate (min-1) 16.8 ± 2.6 20.4 ± 4.7 NA* p\0.05CONCLUSION. Compared to standard PS, NAVA improves patient ventilator interaction byreducing Td and the overall incidence of asynchrony events. There is also a strong trend inreducing delayed cycling. This ongoing trial should provide evidence that NAVA can indeedimprove patient-ventilator synchrony in intubated patients undergoing PS.REFERENCE(S). 1. Sinderby C, Navalesi P et al (1995) Neural control of mechanicalventilation in respiratory failure. Nat Med 5(12):1433-1436.2. Colombo D, Cammarota G et al (2008) Physiologic response to varying levels of pressuresupport and neurally adjusted ventilator assist in patients with acute respiratory failure.Intensive Care Med 34(11):2010-2018.
Resumo:
A passive sampling device called Monitor of NICotine or "MoNIC", was constructed and evaluated by IST laboratory for determining nicotine in Environmental Tobacco Smoke (ETS). Vapour nicotine was passively collected on a potassium bisulfate treated glass fibre filter as collection medium. Analysis of amount of nicotine on the treated filter by gas chromatography equipped with Thermoionic-Specific Detector (GCTSD) after liquid-liquid extraction of 1mL of 5N NaOH : 1 mL of n-heptane saturated with NH3 using quinoline as internal standard. Based on nicotine amount of 0.2 mg/cigarette as reference, the inhaled Cigarette Equivalents (CE) by non-smokers can be calculated. Using the detected CE on the badge for nonsmokers, and comparing with amount of nicotine and cotinine level in saliva of both smokers and exposed non-smokers (N=49), we can confirm the use of the CE concept for estimating exposure to ETS. The Valais CIPRET (Center of information and prevention of the addiction to smoking), is going to organize a big campaign on the subject of the passive addiction to smoking entitled "Smoked passive, we suffer from it, we die from it ". This campaign will take place in 2007 and has for objective to inform clearly the population of Valais of the dangerousness of the passive smoke. More than 1'500 MoNIC badges were gracefully distributed to Swiss population to perform a self-monitoring of population exposure level to ETS, expressed in term of CE. Non-stimulated saliva were also collected to determine ETS biomarkers nicotine/cotinine levels of participating volunteers. Preliminary results of different levels of CE in occupational and non-occupational situations in relation with ETS were presented in this study.
Resumo:
This paper derives a model of markets with system goods and two technological standards. An established standard incurs lower unit production costs but causes a negative externality. The paper derives the conditions for policy intervention and compares the effect of direct and indirect cost-reducing subsidies in two markets with system goods in the presence of externalities. If consumers are committed to the technology by purchasing one of the components, direct subsidies are preferable. For a medium-low cost difference between technological standards and a low externality cost it is optimal to provide a direct subsidy only to the first technology adopter. As the higher the externality cost raises, the more technology adopters should be provided with direct subsidies. This effect is robust in all extensions. In the absence of consumers commitment to a technological standard indirect and direct subsidies are both desirable. In this case, the subsidy to the first adopter is lower then the subsidy to the second adopter. Moreover, for the low cost difference between technological standards and low externality cost the fi rst fi rm chooses a superior standard without policy intervention. Finally, a perfect compatibility between components based on different technological standards enhances an advantage of indirect subsidies for medium-high externality cost and cost difference between technological standards. Journal of Economic Literature Classi fication Numbers: C72, D21, D40, H23, L13, L22, L51, O25, O33, O38. Keywords: Technological standards; complementary products; externalities; cost-reducing subsidies; compatibility.
Resumo:
BACKGROUND: Antipyresis is a common clinical practice in intensive care, although it is unknown if fever is harmful, beneficial, or a negligible adverse effect of infection and inflammation. METHODS: In a randomized study, rectal temperature and discomfort were assessed in 38 surgical intensive care unit patients without neurotrauma or severe hypoxemia and with fever (temperature >/=38.5 degrees C) and systemic inflammatory response syndrome. Eighteen patients received external cooling while 20 received no antipyretic treatment. RESULTS: Temperature and discomfort decreased similarly in both groups after 24 hours. No significant differences in recurrence of fever, incidence of infection, antibiotic therapy, intensive care unit and hospital length of stay, or mortality were noted between the groups. CONCLUSIONS: These results suggest that the systematic suppression of fever may not be useful in patients without severe cranial trauma or significant hypoxemia. Letting fever take its natural course does not seem to harm patients with systemic inflammatory response syndrome or influence the discomfort level and may save costs.