578 resultados para Polychlorinated biphenyls (PCB)
Resumo:
Bio-impedance analysis (BIA) provides a rapid, non-invasive technique for body composition estimation. BIA offers a convenient alternative to standard techniques such as MRI, CT scan or DEXA scan for selected types of body composition analysis. The accuracy of BIA is limited because it is an indirect method of composition analysis. It relies on linear relationships between measured impedance and morphological parameters such as height and weight to derive estimates. To overcome these underlying limitations of BIA, a multi-frequency segmental bio-impedance device was constructed through a series of iterative enhancements and improvements of existing BIA instrumentation. Key features of the design included an easy to construct current-source and compact PCB design. The final device was trialled with 22 human volunteers and measured impedance was compared against body composition estimates obtained by DEXA scan. This enabled the development of newer techniques to make BIA predictions. To add a ‘visual aspect’ to BIA, volunteers were scanned in 3D using an inexpensive scattered light gadget (Xbox Kinect controller) and 3D volumes of their limbs were compared with BIA measurements to further improve BIA predictions. A three-stage digital filtering scheme was also implemented to enable extraction of heart-rate data from recorded bio-electrical signals. Additionally modifications have been introduced to measure change in bio-impedance with motion, this could be adapted to further improve accuracy and veracity for limb composition analysis. The findings in this thesis aim to give new direction to the prediction of body composition using BIA. The design development and refinement applied to BIA in this research programme suggest new opportunities to enhance the accuracy and clinical utility of BIA for the prediction of body composition analysis. In particular, the use of bio-impedance to predict limb volumes which would provide an additional metric for body composition measurement and help distinguish between fat and muscle content.
Resumo:
This research is motivated by a practical application observed at a printed circuit board (PCB) manufacturing facility. After assembly, the PCBs (or jobs) are tested in environmental stress screening (ESS) chambers (or batch processing machines) to detect early failures. Several PCBs can be simultaneously tested as long as the total size of all the PCBs in the batch does not violate the chamber capacity. PCBs from different production lines arrive dynamically to a queue in front of a set of identical ESS chambers, where they are grouped into batches for testing. Each line delivers PCBs that vary in size and require different testing (or processing) times. Once a batch is formed, its processing time is the longest processing time among the PCBs in the batch, and its ready time is given by the PCB arriving last to the batch. ESS chambers are expensive and a bottleneck. Consequently, its makespan has to be minimized. ^ A mixed-integer formulation is proposed for the problem under study and compared to a formulation recently published. The proposed formulation is better in terms of the number of decision variables, linear constraints and run time. A procedure to compute the lower bound is proposed. For sparse problems (i.e. when job ready times are dispersed widely), the lower bounds are close to optimum. ^ The problem under study is NP-hard. Consequently, five heuristics, two metaheuristics (i.e. simulated annealing (SA) and greedy randomized adaptive search procedure (GRASP)), and a decomposition approach (i.e. column generation) are proposed—especially to solve problem instances which require prohibitively long run times when a commercial solver is used. Extensive experimental study was conducted to evaluate the different solution approaches based on the solution quality and run time. ^ The decomposition approach improved the lower bounds (or linear relaxation solution) of the mixed-integer formulation. At least one of the proposed heuristic outperforms the Modified Delay heuristic from the literature. For sparse problems, almost all the heuristics report a solution close to optimum. GRASP outperforms SA at a higher computational cost. The proposed approaches are viable to implement as the run time is very short. ^
Resumo:
This research deals with the development of a dynamic job quotation system for printed circuit board (PCB) fabrication, which can estimate the price and completion time of a job based on customer preference and current capacity of the shop floor. The primary purpose of building a dynamic quotation system is to maximize the company's profit by quoting optimum lead-time and competitive price for the day-to-day orders received from different customers and original equipment manufacturers. The system was developed using MS-Access relational database. Evaluating the output of the system it was observed that the dynamic system provided more reliable estimation of the lead-time needed for fabricating new jobs. The overall price quoted by the system was competitive with higher profit margin when compared to traditional static systems. This system would therefore provide a vital link between the job quoting and scheduling system of the firm enabling better utilization of the available resources.
Resumo:
The electronics industry, is experiencing two trends one of which is the drive towards miniaturization of electronic products. The in-circuit testing predominantly used for continuity testing of printed circuit boards (PCB) can no longer meet the demands of smaller size circuits. This has lead to the development of moving probe testing equipment. Moving Probe Test opens up the opportunity to test PCBs where the test points are on a small pitch (distance between points). However, since the test uses probes that move sequentially to perform the test, the total test time is much greater than traditional in-circuit test. While significant effort has concentrated on the equipment design and development, little work has examined algorithms for efficient test sequencing. The test sequence has the greatest impact on total test time, which will determine the production cycle time of the product. Minimizing total test time is a NP-hard problem similar to the traveling salesman problem, except with two traveling salesmen that must coordinate their movements. The main goal of this thesis was to develop a heuristic algorithm to minimize the Flying Probe test time and evaluate the algorithm against a "Nearest Neighbor" algorithm. The algorithm was implemented with Visual Basic and MS Access database. The algorithm was evaluated with actual PCB test data taken from Industry. A statistical analysis with 95% C.C. was performed to test the hypothesis that the proposed algorithm finds a sequence which has a total test time less than the total test time found by the "Nearest Neighbor" approach. Findings demonstrated that the proposed heuristic algorithm reduces the total test time of the test and, therefore, production cycle time can be reduced through proper sequencing.
Resumo:
The ability of a previously PCB-enriched microbial culture from Venice Lagoon marine sediments to dechlorinate pentachlorophenol (PCP) and 2,3,5-trichlorophenol (2,3,5-TCP) was confirmed under anaerobic conditions in microcosms consisting of site water and sediment. Dechlorination activities against Aroclor 1254 PCB mixture were also confirmed as control. Pentachlorophenol was degraded to 2,4,6-TCP (75.92±0.85 mol%), 3,5-DCP (6.40±0.75 mol%), and phenol (15.40±0.87 mol%). From the distribution of the different dechlorination products accumulated in the PCP-spiked cultures over time, two dechlorination pathways for PCP were proposed: (i) PCP to 2,3,4,6-TeCP, then to 2,4,6-TCP through the removal of both meta double-flanked chlorine substituents (main pathway); (ii) alternately, PCP to 2,3,5,6-TeCP, 2,3,5-TCP, 3,5-DCP, then phenol, through the removal of the para double-flanked chlorine, followed by ortho single-flanked chlorines, and finally meta unflanked chlorines (minor pathway). Removal of meta double-flanked chlorines is thus preferred over all other substituents. 2,3,5-TCP, that completely lacks double-flanked chlorines, was degraded to 3,5-DCP through removal of the ortho single-flanked chlorine, with a 99.6% reduction in initial concentration of 2,3,5-TCP by week 14. 16S rRNA PCR-DGGE using Chloroflexi-specific primers revealed a different role of the two microorganisms VLD-1 and VLD-2, previously identified as dechlorinators in the Aroclor 1254 PCB-enriched community, in the dehalogenation of chlorophenols. VLD-1 was observed both in PCP- and TCP-dechlorinating communities, whereas VLD-2 only in TCP-dechlorinating communities. This indicates that VLD-1 and VLD-2 may both dechlorinate ortho single-flanked chlorines, but only VLD-1 is able to remove double-flanked meta or para chlorines.
Resumo:
Total knee arthroplasty (TKA) has revolutionized the life of millions of patients and it is the most efficient treatment in cases of osteoarthritis. The increase in life expectancy has lowered the average age of the patient, which requires a more enduring and performing prosthesis. To improve the design of implants and satisfying the patient's needs, a deep understanding of the knee Biomechanics is needed. To overcome the uncertainties of numerical models, recently instrumented knee prostheses are spreading. The aim of the thesis was to design and manifacture a new prototype of instrumented implant, able to measure kinetics and kinematics (in terms of medial and lateral forces and patellofemoral forces) of different interchangeable designs of prosthesis during experiments tests within a research laboratory, on robotic knee simulator. Unlike previous prototypes it was not aimed for industrial applications, but purely focusing on research. After a careful study of the literature, and a preliminary analytic study, the device was created modifying the structure of a commercial prosthesis and transforming it in a load cell. For monitoring the kinematics of the femoral component a three-layers, piezoelettric position sensor was manifactured using a Velostat foil. This sensor has responded well to pilot test. Once completed, such device can be used to validate existing numerical models of the knee and of TKA and create new ones, more accurate.It can lead to refinement of surgical techniques, to enhancement of prosthetic designs and, once validated, and if properly modified, it can be used also intraoperatively.
Resumo:
In an investigation of gas hydrates in deep ocean sediments, gas samples from Deep Sea Drilling Project Site 533 on the Blake Outer Ridge in the northwest Atlantic were obtained for molecular and isotopic analyses. Gas samples were collected from the first successful deployment of a pressure core barrel (PCB) in a hydrate region. The pressure decline curves from two of the four PCB retrievals at in situ pressures suggested the presence of small amounts of gas hydrates. Compositional and isotopic measurements of gases from several points along the pressure decline curve indicated that (1) biogenic methane (d13C = -68 per mil; C1/C2 = 5000) was the dominant gas (>90%); (2) little fractionation in the C1/C2 ratio or the C carbon isotopic composition occurred as gas hydrates decomposed during pressure decline experiments; (3) the percent of C3, i-C4, and CO2 degassed increased as the pressure declined, indicating that these molecules may help stabilize the hydrate structure; (4) excess nitrogen was present during initial degassing; and (5) C1/C2 ratios and isotopic ratios of C gases were similar to those obtained from conventional core sampling. The PCB gas also contained trace amounts of saturated, acyclic, cyclic, and aromatic C5-C14 hydrocarbons, as well as alkenes and tetrahydrothiophenes. Gas from a decomposed specimen of gas hydrate had similar molecular and isotopic ratios to the PCB gas (d13C of -68 per mil for methane and a C1/C2 ratio of about 6000). Regular trends in the d13C of methane (about -95 to -60 per mil) and C1/C2 ratios (about 25000 to 2000) were observed with depth. Capillary gas chromatography (GC) and total scanning fluorescence measurements of extracted organic material were characteristic of hydrocarbons dominated by a marine source, though significant amounts of perylene were also present.
Resumo:
The relative contribution of regional contamination versus dietary differences to geographic variation in polar bear (Ursus maritimus) contaminant levels is unknown. Dietary variation between Alaska, Canada, East Greenland, and Svalbard subpopulations was assessed by muscle nitrogen and carbon stable isotope (d15N, d13C) and adipose fatty acid (FA) signatures relative to their main prey (ringed seals). Western and southern Hudson Bay signatures were characterized by depleted d15N and d13C, lower proportions of C20 and C22 monounsaturated FAs and higher proportions of C18 and longer chain polyunsaturated FAs. East Greenland and Svalbard signatures were reversed relative to Hudson Bay. Alaskan and Canadian Arctic signatures were intermediate. Between-subpopulation dietary differences predominated over interannual, seasonal, sex, or age variation. Among various brominated and chlorinated contaminants, diet signatures significantly explained variation in adipose levels of polybrominated diphenyl ether (PBDE) flame retardants (14-15%) and legacy PCBs (18-21%). However, dietary influence was contaminant class-specific, since only low or nonsignificant proportions of variation in organochlorine pesticide (e.g., chlordane) levels were explained by diet. Hudson Bay diet signatures were associated with lower PCB and PBDE levels, whereas East Greenland and Svalbard signatures were associated with higher levels. Understanding diet/food web factors is important to accurately interpret contaminant trends, particularly in a changing Arctic.
Resumo:
As a model of high trophic level carnivores, sledge dogs were fed from 2 to 18 months of age with minke whale blubber containing organohalogen compounds (OHC) corresponding to 128 µg PCB/day. Controls were fed uncontaminated porcine fat. Thyroid hormone levels were assessed in 7 exposed and 7 control sister bitches (sampled at age 6-18 months) and 4 exposed and 4 control pups, fed the same diet as their mothers (sampled age 3-12 months). Lower free and total T3 and T4 were seen in exposed vs. control bitches beyond 10 months of age, and total T3 was lower through 3-12 months of age in exposed pups. A negative correlation with thyroid gland weight was significant for SumDDT, as was a positive association with total T3 for dieldrin. This study therefore supports observational data that OHCs may adversely affect thyroid functions, and it suggests that OHC exposure duration of 10 months or more may be required for current OHC contamination levels to result in detectable adverse effects on thyroid hormone dynamics.
Resumo:
A new wideband transition between substrate integrated waveguide (SIW) and rectangular waveguide (RWG) that resembles a right angle waveguide E-bend at Ku/K band is presented. The transition has removable but stable mounting, requires only PCB fabrication and has adaptable quality and bandwidth characteristics depending on the number of substrate layers used.
Resumo:
DANTAS, Rodrigo Assis Neves; NÓBREGA, Walkíria Gomes da; MORAIS FILHO, Luiz Alves; MACÊDO, Eurides Araújo Bezerra de ; FONSECA , Patrícia de Cássia Bezerra; ENDERS, Bertha Cruz; MENEZES, Rejane Maria Paiva de; TORRES , Gilson de Vasconcelos. Paradigms in health care and its relationship to the nursing theories: an analytical test . Revista de Enfermagem UFPE on line. v.4,n.2, p.16-24.abr/jun. 2010. Disponível em < http://www.ufpe.br/revistaenfermagem/index.php/revista>.
Resumo:
Thesis (Master's)--University of Washington, 2016-08
Resumo:
DANTAS, Rodrigo Assis Neves; NÓBREGA, Walkíria Gomes da; MORAIS FILHO, Luiz Alves; MACÊDO, Eurides Araújo Bezerra de ; FONSECA , Patrícia de Cássia Bezerra; ENDERS, Bertha Cruz; MENEZES, Rejane Maria Paiva de; TORRES , Gilson de Vasconcelos. Paradigms in health care and its relationship to the nursing theories: an analytical test . Revista de Enfermagem UFPE on line. v.4,n.2, p.16-24.abr/jun. 2010. Disponível em < http://www.ufpe.br/revistaenfermagem/index.php/revista>.
Resumo:
Chemical contamination levels and stable isotope ratios provide integrated information about contaminant exposure, trophic position and also biological and environmental influences on marine organisms. By combining these approaches with otolith shape analyses, the aim of the present study was to document the spatial variability of Hg and PCB contamination of the European hake (Merluccius merluccius) in the French Mediterranean, hypothesizing that local contaminant sources, environmental conditions and biological specificities lead to site-specific contamination patterns. High Hg concentrations discriminated Corsica (average: 1.36 ± 0.80 μg g− 1 dm) from the Gulf of Lions (average values < 0.5 μg g− 1 dm), where Rhône River input caused high PCB burdens. CB 153 average concentrations ranged between 4.00 ± 0.64 and 18.39 ± 12.38 ng g− 1 dm in the Gulf of Lions, whatever the sex of the individuals, whereas the highest values in Corsica were 6.75 ± 4.22 ng g− 1 dm. Otolith shape discriminated juveniles and adults, due to their different habitats. The use of combined ecotracers was revealed as a powerful tool to discriminate between fish populations at large and small spatial scale, and to enable understanding of the environmental and biological influences on contamination patterns.
Resumo:
This thesis presents the achievements and scientific work conducted using a previously designed and fabricated 64 x 64-pixel ion camera with the use of a 0.35 μm CMOS technology. We used an array of Ion Sensitive Field Effect Transistors (ISFETs) to monitor and measure chemical and biochemical reactions in real time. The area of our observation was a 4.2 x 4.3 mm silicon chip while the actual ISFET array covered an area of 715.8 x 715.8 μm consisting of 4096 ISFET pixels in total with a 1 μm separation space among them. The ion sensitive layer, the locus where all reactions took place was a silicon nitride layer, the final top layer of the austriamicrosystems 0.35 μm CMOS technology used. Our final measurements presented an average sensitivity of 30 mV/pH. With the addition of extra layers we were able to monitor a 65 mV voltage difference during our experiments with glucose and hexokinase, whereas a difference of 85 mV was detected for a similar glucose reaction mentioned in literature, and a 55 mV voltage difference while performing photosynthesis experiments with a biofilm made from cyanobacteria, whereas a voltage difference of 33.7 mV was detected as presented in literature for a similar cyanobacterial species using voltamemtric methods for detection. To monitor our experiments PXIe-6358 measurement cards were used and measurements were controlled by LabVIEW software. The chip was packaged and encapsulated using a PGA-100 chip carrier and a two-component commercial epoxy. Printed circuit board (PCB) has also been previously designed to provide interface between the chip and the measurement cards.