908 resultados para Phantom Borders


Relevância:

10.00% 10.00%

Publicador:

Resumo:

In orange commercial farms, Zn deficiencies symptoms and small fruits were observed in Corrientes, Argentine. During four years (1995 to 1998), Valencia orange (Citrus sinensis Osb.) on Rough lemon (C. jambhiri Lush.) rootstock, implanted in 1974 in sandy soil, where six treatments were tested. Treatments varied from 1 to 3 Kg KCl.tree-1.year-1 (applied in April and December) with and without Zineb 80, 0,35%. year-1, 20 L. tree-1 (13,3 g Zn.tree-1 applied in December). The experimental design was a randomized complete block with four replications, with a single tree and borders in the experimental plot. Foliar sample were taken every year in Autumn and Summer, foliar concentrations of Zn and K were determined by atomic spectrum absorption. Harvested fruits were classified into small, medium and big. Analysis of Variance, Tukey test and Pearson correlations between production and foliar concentrations were performed. Higher fertilization levels of K with Zn increased medium and big fruits production (Kg and percentage). Foliar concentrations of K and Zn were positively correlated with big and medium fruit production and negatively correlated with small one. Chemical names used: Ethilenbis-ditiocarbamate of Zn (Zineb).

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE: To implement and characterize an isotropic three-dimensional cardiac T2 mapping technique. METHODS: A self-navigated three-dimensional radial segmented balanced steady-state free precession pulse sequence with an isotropic 1.7-mm spatial resolution was implemented at 3T with a variable T2 preparation module. Bloch equation and Monte Carlo simulations were performed to determine the influence of the heart rate, B1 inhomogeneity and noise on the T2 fitting accuracy. In a phantom study, the accuracy of the pulse sequence was studied through comparison with a gold-standard spin-echo T2 mapping method. The robustness and homogeneity of the technique were ascertained in a study of 10 healthy adult human volunteers, while first results obtained in patients are reported. RESULTS: The numerical simulations demonstrated that the heart rate and B1 inhomogeneity cause only minor deviations in the T2 fitting, whereas the phantom study showed good agreement of the technique with the gold standard. The volunteer study demonstrated an average myocardial T2 of 40.5 ± 3.3 ms and a <15% T2 gradient in the base-apex and anterior-inferior direction. In three patients, elevated T2 values were measured in regions with expected edema. CONCLUSION: This respiratory self-navigated isotropic three-dimensional technique allows for accurate and robust in vitro and in vivo T2 quantification. Magn Reson Med 73:1549-1554, 2015. © 2014 Wiley Periodicals, Inc.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE: All methods presented to date to map both conductivity and permittivity rely on multiple acquisitions to compute quantitatively the magnitude of radiofrequency transmit fields, B1+. In this work, we propose a method to compute both conductivity and permittivity based solely on relative receive coil sensitivities ( B1-) that can be obtained in one single measurement without the need to neither explicitly perform transmit/receive phase separation nor make assumptions regarding those phases. THEORY AND METHODS: To demonstrate the validity and the noise sensitivity of our method we used electromagnetic finite differences simulations of a 16-channel transceiver array. To experimentally validate our methodology at 7 Tesla, multi compartment phantom data was acquired using a standard 32-channel receive coil system and two-dimensional (2D) and 3D gradient echo acquisition. The reconstructed electric properties were correlated to those measured using dielectric probes. RESULTS: The method was demonstrated both in simulations and in phantom data with correlations to both the modeled and bench measurements being close to identity. The noise properties were modeled and understood. CONCLUSION: The proposed methodology allows to quantitatively determine the electrical properties of a sample using any MR contrast, with the only constraint being the need to have 4 or more receive coils and high SNR. Magn Reson Med, 2014. © 2014 Wiley Periodicals, Inc.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND: Left atrial (LA) dilatation is associated with a large variety of cardiac diseases. Current cardiovascular magnetic resonance (CMR) strategies to measure LA volumes are based on multi-breath-hold multi-slice acquisitions, which are time-consuming and susceptible to misregistration. AIM: To develop a time-efficient single breath-hold 3D CMR acquisition and reconstruction method to precisely measure LA volumes and function. METHODS: A highly accelerated compressed-sensing multi-slice cine sequence (CS-cineCMR) was combined with a non-model-based 3D reconstruction method to measure LA volumes with high temporal and spatial resolution during a single breath-hold. This approach was validated in LA phantoms of different shapes and applied in 3 patients. In addition, the influence of slice orientations on accuracy was evaluated in the LA phantoms for the new approach in comparison with a conventional model-based biplane area-length reconstruction. As a reference in patients, a self-navigated high-resolution whole-heart 3D dataset (3D-HR-CMR) was acquired during mid-diastole to yield accurate LA volumes. RESULTS: Phantom studies. LA volumes were accurately measured by CS-cineCMR with a mean difference of -4.73 ± 1.75 ml (-8.67 ± 3.54%, r2 = 0.94). For the new method the calculated volumes were not significantly different when different orientations of the CS-cineCMR slices were applied to cover the LA phantoms. Long-axis "aligned" vs "not aligned" with the phantom long-axis yielded similar differences vs the reference volume (-4.87 ± 1.73 ml vs. -4.45 ± 1.97 ml, p = 0.67) and short-axis "perpendicular" vs. "not-perpendicular" with the LA long-axis (-4.72 ± 1.66 ml vs. -4.75 ± 2.13 ml; p = 0.98). The conventional bi-plane area-length method was susceptible for slice orientations (p = 0.0085 for the interaction of "slice orientation" and "reconstruction technique", 2-way ANOVA for repeated measures). To use the 3D-HR-CMR as the reference for LA volumes in patients, it was validated in the LA phantoms (mean difference: -1.37 ± 1.35 ml, -2.38 ± 2.44%, r2 = 0.97). Patient study: The CS-cineCMR LA volumes of the mid-diastolic frame matched closely with the reference LA volume (measured by 3D-HR-CMR) with a difference of -2.66 ± 6.5 ml (3.0% underestimation; true LA volumes: 63 ml, 62 ml, and 395 ml). Finally, a high intra- and inter-observer agreement for maximal and minimal LA volume measurement is also shown. CONCLUSIONS: The proposed method combines a highly accelerated single-breathhold compressed-sensing multi-slice CMR technique with a non-model-based 3D reconstruction to accurately and reproducibly measure LA volumes and function.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper describes an evaluation framework that allows a standardized and quantitative comparison of IVUS lumen and media segmentation algorithms. This framework has been introduced at the MICCAI 2011 Computing and Visualization for (Intra)Vascular Imaging (CVII) workshop, comparing the results of eight teams that participated. We describe the available data-base comprising of multi-center, multi-vendor and multi-frequency IVUS datasets, their acquisition, the creation of the reference standard and the evaluation measures. The approaches address segmentation of the lumen, the media, or both borders; semi- or fully-automatic operation; and 2-D vs. 3-D methodology. Three performance measures for quantitative analysis have been proposed. The results of the evaluation indicate that segmentation of the vessel lumen and media is possible with an accuracy that is comparable to manual annotation when semi-automatic methods are used, as well as encouraging results can be obtained also in case of fully-automatic segmentation. The analysis performed in this paper also highlights the challenges in IVUS segmentation that remains to be solved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In May 1985 José Agustín Goytisolo launched an ambitious project to translate into Spanish works originally written in Catalan. To this end, with a small group of collaborators he founded the Marca Hispanica collection. Its aim was to spread Catalan literature beyond its borders to reach millions of readers of Spanish through schools, teachers and language academies around the world. The initial idea was to make available in bilingual editions a hundred representative works of Catalan literature but, in the event, only twenty-two volumes were ever published. Based on access to unpublished documents, in this article we defend this endeavour, report on its progress and relate the circumstances, beyond the control of the participants, that led to its demise.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE: To improve coronary magnetic resonance angiography (MRA) by combining a two-dimensional (2D) spatially selective radiofrequency (RF) pulse with a T2 -preparation module ("2D-T2 -Prep"). METHODS: An adiabatic T2 -Prep was modified so that the first and last pulses were of differing spatial selectivity. The first RF pulse was replaced by a 2D pulse, such that a pencil-beam volume is excited. The last RF pulse remains nonselective, thus restoring the T2 -prepared pencil-beam, while tipping the (formerly longitudinal) magnetization outside of the pencil-beam into the transverse plane, where it is then spoiled. Thus, only a cylinder of T2 -prepared tissue remains for imaging. Numerical simulations were followed by phantom validation and in vivo coronary MRA, where the technique was quantitatively evaluated. Reduced field-of-view (rFoV) images were similarly studied. RESULTS: In vivo, full field-of-view 2D-T2 -Prep significantly improved vessel sharpness as compared to conventional T2 -Prep, without adversely affecting signal-to-noise (SNR) or contrast-to-noise ratios (CNR). It also reduced respiratory motion artifacts. In rFoV images, the SNR, CNR, and vessel sharpness decreased, although scan time reduction was 60%. CONCLUSION: When compared with conventional T2 -Prep, the 2D-T2 -Prep improves vessel sharpness and decreases respiratory ghosting while preserving both SNR and CNR. It may also acquire rFoV images for accelerated data acquisition.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVES: The aims of the study were to use cone beam computed tomography (CBCT) images of nasopalatine duct cysts (NPDC) and to calculate the diameter, surface area, and 3D-volume using a custom-made software program. Furthermore, any associations of dimensions of NPDC with age, gender, presence/absence of maxillary incisors/canines (MI/MC), endodontic treatment of MI/MC, presenting symptoms, and postoperative complications were evaluated. MATERIAL AND METHODS: The study comprised 40 patients with a histopathologically confirmed NPDC. On preoperative CBCT scans, curves delineating the cystic borders were drawn in all planes and the widest diameter (in millimeter), surface area (in square millimeter), and volume (in cubic millimeter) were calculated. RESULTS: The overall mean cyst diameter was 15 mm (range 7-47 mm), the mean cyst surface area 566 mm(2) (84-4,516 mm(2)), and the mean cyst volume 1,735 mm(3) (65-25,350 mm(3)). For 22 randomly allocated cases, a second measurement resulted in a mean absolute aberration of ±4.2 % for the volume, ±2.8 % for the surface, and ±4.9 % for the diameter. A statistically significant association was found for the CBCT determined cyst measurements and the need for preoperative endodontic treatment to MI/MC and for postoperative complications. CONCLUSION: In the hands of a single experienced operator, the novel software exhibited high repeatability for measurements of cyst dimensions. Further studies are needed to assess the application of this tool for dimensional analysis of different jaw cysts and lesions including treatment planning. CLINICAL RELEVANCE: Accurate radiographic information of the bone volume lost (osteolysis) due to expansion of a cystic lesion in three dimensions could help in personalized treatment planning.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim of this thesis is to create the energy balance from county of South Savo and 20 municipalities comprising the year 2006. The energy balance is restricted to county and municipality borders. Purpose of energy balance is to clarify the present state of energy supply and present information for future decisions. The main objectives for the future are e.g. replacing oil with renewable energy sources and exploiting the forest reserves of South Savo more effectively. Today South Savo is known as being one of the forerunners in use of renewable energy. The growing demand for energy is in South Savo mostly covered with renewable energy sources such as forest chips. The initial data for this thesis is gathered from local energy companies and energy producers. This thesis also exploits formerly made energy balances, publications and statistic from different organisations. The literature study of thesis begins with the basic information about South Savo and energy sources used in the year 2006. Following the thesis includes the energy balance consisting of primary energy sources and consumption of energy. Rest of the thesis includes facts about carbon dioxide emissions, future energy sources and conclusions of results, reliability and expected use of this thesis. Results of this thesis define well the present state of South Savo and are in line with county goals. The results will be used as an aid for policy-making and for considering the condition of current energy supply in South Savo. The method of doing this energy balance can be adapted for other counties as well.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: To assess the feasibility of a method based on microwave spectrometry to detect structural distortions of metallic stents in open air conditions and envisage the prospects of this approach toward possible medical applicability for the evaluation of implanted stents. Methods: Microwave absorbance spectra between 2.0 and 18.0 GHz were acquired in open air for the characterization of a set of commercial stents using a specifically design setup. Rotating each sample over 360º, 2D absorbance diagrams were generated as a function of frequency and rotation angle. To check our approach for detecting changes in stent length (fracture) and diameter (recoil), two specific tests were performed in open air. Finally, with a few adjustments, this same system provides 2D absorbance diagrams of stents immersed in a water-based phantom, this time over a bandwidth ranging from 0.2 to 1.8 GHz. Results: The authors show that metallic stents exhibit characteristic resonant frequencies in their microwave absorbance spectra in open air which depend on their length and, as a result, may reflect the occurrence of structural distortions. These resonances can be understood considering that such devices behave like dipole antennas in terms of microwave scattering. From fracture tests, the authors infer that microwave spectrometry provides signs of presence of Type I to Type IV stent fractures and allows in particular a quantitative evaluation of Type III and Type IV fractures. Recoil tests show that microwave spectrometry seems able to provide some quantitative assessment of diametrical shrinkage, but only if it involves longitudinal shortening. Finally, the authors observe that the resonant frequencies of stents placed inside the phantom shift down with respect to the corresponding open air frequencies, as it should be expected considering the increase of dielectric permittivity from air to water. Conclusions: The evaluation of stent resonant frequencies provided by microwave spectrometry allows detection and some quantitative assessment of stent fracture and recoil in open air conditions. Resonances of stents immersed in water can be also detected and their characteristic frequencies are in good agreement with theoretical estimates. Although these are promising results, further verifica tion in a more relevant phantom is required in order to foresee the real potential of this approach.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJETIVO: Avaliar a precisão das doses de radiação absorvidas na terapia de transplantes de medula óssea durante a técnica de irradiação de corpo inteiro. MATERIAIS E MÉTODOS: Utilizaram-se 200 pastilhas de sulfato de cálcio com disprósio compactado com teflon (CaSO4 + teflon), calibradas no ar e no "phantom", selecionadas aleatoriamente e dispostas em grupos de cinco no corpo dos pacientes. As leituras dosimétricas foram efetuadas pela leitora Harshaw 4000A. Nove pacientes foram irradiados no corpo inteiro em paralelos e em opostos laterais, utilizando-se unidade de cobalto-60, modelo Alcion II, com taxa de dose de 0,80 Gy/min a 80,5 cm, {campo (10 × 10) cm²}. A dosimetria dessa unidade foi realizada com dosímetro Victoreen 500. Para a determinação da dose média em cada ponto avaliado usaram-se os fatores individuais de calibração das pastilhas no ar e no "phantom", colocando-se um "build up" de 2 mm para superficializar a dose à distância de 300 cm. RESULTADOS: Em 70% dos pacientes obteve-se variação de dose menor que 5% e em 30% dos pacientes essa variação foi inferior a 10%, quando comparados os valores medidos com aqueles calculados em cada ponto. Na cabeça ocorre absorção, em média, de 14% da dose administrada, e nos pulmões, acréscimo de 2% na dose administrada. Nos pacientes com distância látero-lateral maior que 35 cm as variações entre as doses calculadas e medidas podem chegar a 30% da dose desejada, sem o uso de filtros compensadores. CONCLUSÃO: Os valores medidos das doses absorvidas nos diversos pontos anatômicos, comparados aos valores desejados (teóricos), apresentam tolerância de ±10%, considerando-se as diferenças anatômicas existentes, quando utilizados os fatores de calibração individuais das pastilhas.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJETIVO: Estudar a intercambiabilidade dos resultados de densidade mineral óssea entre máquinas de absortimetria de raios-x em duas energias (DEXA) Hologic® e de absortimetria computadorizada de raios-x convencionais em duas energias (CDEXA) Cromox®. MATERIAIS E MÉTODOS: Para 38 casos de quadril e 31 casos de coluna lombar avaliados em 43 pacientes atendidos em um centro de diagnóstico por imagem, medidas de densidade mineral óssea foram realizadas em ambas as máquinas. A máquina Cromox® foi calibrada usando-se o phantom Cromox® de referência para absortimetria óssea. RESULTADOS: Forte correlação entre os resultados obtidos nas duas máquinas foi encontrada para cada sítio do esqueleto. O coeficiente de correlação linear medido para o colo femoral direito foi r = 0,920, p < 0,0001, e r = 0,923, p < 0,0001 para as vértebras L2-L4 da coluna lombar. Como o resultado expresso em Tscore é importante na prática clínica em densitometria óssea, a diferença média em Tscore entre as máquinas foi calculada, resultando em média aritmética de DTscore = 0,191 para o quadril e média aritmética de DTscore = 0,228 para a coluna. Estado esquelético é estabelecido de acordo com a definição da Organização Mundial da Saúde como normal, osteopenia ou osteoporose. A concordância de estado esquelético entre as máquinas foi superior a 76% para o quadril e superior a 77% para a coluna, e superior a 96% quando se considerou concordância em ao menos um dos dois sítios. CONCLUSÃO: Os coeficientes de correlação linear obtidos são muito próximos das referências internacionais entre máquinas padrão-ouro, reportados como r > 0,95. Para ambos os sítios, a diferença média aritmética em Tscore entre as máquinas é pequena, menor que a menor variação significativa.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Gustav Hasford is the author of two important Vietnam War novels: The Short-Timers (1979), which was adapted by Stanley Kubrick into Full Metal Jacket (1987), and The Phantom Blooper (1990), its sequel. Relentlessly critical of the war that destroyed his generation, Hasford uses an array of Gothic themes, tropes and figures - such as the werewolf, vampire, and ghost - to describe the transformation of men into monsters that begins with basic training and can never be reversed. These and other Gothic devices allow Hasford to demystify and disenchant the Vietnam War, to strip it of euphemisms and official myths, and to reveal the violence that lays beneath. Unlike other well-known writers of the same generation, such as Michael Herr and Chris O'Brien, Hasford eschews postmodern techniques in order to pursue a rhetorical strategy of horror combined with black humor. The results are two novels of extraordinary ferocity, critical acumen and wit. The chapter concludes with an analysis of the specifically Gothic reading experience of ethical dilemma - a Gothic exercise in judgment - choreographed by both narratives.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE: Iterative algorithms introduce new challenges in the field of image quality assessment. The purpose of this study is to use a mathematical model to evaluate objectively the low contrast detectability in CT. MATERIALS AND METHODS: A QRM 401 phantom containing 5 and 8 mm diameter spheres with a contrast level of 10 and 20 HU was used. The images were acquired at 120 kV with CTDIvol equal to 5, 10, 15, 20 mGy and reconstructed using the filtered back-projection (FBP), adaptive statistical iterative reconstruction 50% (ASIR 50%) and model-based iterative reconstruction (MBIR) algorithms. The model observer used is the Channelized Hotelling Observer (CHO). The channels are dense difference of Gaussian channels (D-DOG). The CHO performances were compared to the outcomes of six human observers having performed four alternative forced choice (4-AFC) tests. RESULTS: For the same CTDIvol level and according to CHO model, the MBIR algorithm gives the higher detectability index. The outcomes of human observers and results of CHO are highly correlated whatever the dose levels, the signals considered and the algorithms used when some noise is added to the CHO model. The Pearson coefficient between the human observers and the CHO is 0.93 for FBP and 0.98 for MBIR. CONCLUSION: The human observers' performances can be predicted by the CHO model. This opens the way for proposing, in parallel to the standard dose report, the level of low contrast detectability expected. The introduction of iterative reconstruction requires such an approach to ensure that dose reduction does not impair diagnostics.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Connectivity analysis on diffusion MRI data of the whole- brain suffers from distortions caused by the standard echo- planar imaging acquisition strategies. These images show characteristic geometrical deformations and signal destruction that are an important drawback limiting the success of tractography algorithms. Several retrospective correction techniques are readily available. In this work, we use a digital phantom designed for the evaluation of connectivity pipelines. We subject the phantom to a âeurooetheoretically correctâeuro and plausible deformation that resembles the artifact under investigation. We correct data back, with three standard methodologies (namely fieldmap-based, reversed encoding-based, and registration- based). Finally, we rank the methods based on their geometrical accuracy, the dropout compensation, and their impact on the resulting connectivity matrices.