967 resultados para PERCUTANEOUS CYSTOSCOPY


Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVES: Pulmonary valve insufficiency remains a leading cause for reoperations in congenital cardiac surgery. The current percutaneous approach is limited by the size of the access vessel and variable right ventricular outflow tract morphology. This study assesses the feasibility of transapical pulmonary valve replacement based on a new valved stent construction concept. METHODS: A new valved stent design was implanted off-pump under continuous intracardiac echocardiographic and fluoroscopic guidance into the native right ventricular outflow tract in 8 pigs (48.5 +/- 6.0 kg) through the right ventricular apex, and device function was studied by using invasive and noninvasive measures. RESULTS: Procedural success was 100% at the first attempt. Procedural time was 75 +/- 15 minutes. All devices were delivered at the target site with good acute valve function. No valved stents dislodged. No animal had significant regurgitation or paravalvular leaking on intracardiac echocardiographic analysis. All animals had a competent tricuspid valve and no signs of right ventricular dysfunction. The planimetric valve orifice was 2.85 +/- 0.32 cm(2). No damage to the pulmonary artery or structural defect of the valved stents was found at necropsy. CONCLUSIONS: This study confirms the feasibility of direct access valve replacement through the transapical procedure for replacement of the pulmonary valve, as well as validity of the new valved stent design concept. The transapical procedure is targeting a broader patient pool, including the very young and the adult patient. The device design might not be restricted to failing conduits only and could allow for implantation in a larger patient population, including those with native right ventricular outflow tract configurations.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Many routes have been described for percutaneous adrenal gland biopsy. They require either a complex non-axial path or a long hydrodissection or even pass through an organ thereby increasing complications. We describe here an approach using an artificially-induced carbon dioxide (CO2) pneumothorax, performed as an outpatient procedure in a 57-year-old woman. Under local anaesthesia, 200 ml of CO2 was injected in the pleural space through a Veress needle under computed tomography fluoroscopy, to clear the lung parenchyma from the biopsy route. Using this technique, transthoracic adrenal biopsy can be performed under simple local anaesthesia as an safely outpatient procedure.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Two common herbicides; isoproturon and bentazon, are strong skin irritants and cross the skin barrier easily. Assessment of percutaneous absorption of these substances is a very important step in the evaluation of any dermal or transdermal dose, especially among agricultural workers who frequently have dermal exposures during crop treatment. The aims of the study were to determine the permeation rate of human skin for both herbicides in vitro, and histologically evaluate skin damage due to irritation at different concentrations. Skin penetration was assessed using a dynamic flow-through in vitro penetration system and analysis were performed with ion trap LC-MS (acidified water: acetronitile, C18 column). Two concentrations of bentazon (75 and 150 μg/mL) and isoproturon (125 and 250 μg/mL) in saline solution were applied on excised human skin from several donors. Saline water was used as receptor fluid. Collection times were: 4, 8, and 24 hours. After the experiments, the skin was removed and examined by histopathology for apoptosis, acanthosis, acantholysis and epidermolysis. The skin permeation rate, J, was calculated from the slope of the cumulative amount permeated as a function of time. The lag time, tL, was assigned from the time-axis intercept of the extrapolation of this linearity. Our results showed that tL for bentazon and isoproturon for both concentrations tested were similar; 2, 1.5 hours, respectively. Bentazon had a lowerer J compared to isoproturon; 350, 600 ng/cm2/h, respectively. Some acanthosis was observed after 8 hours of exposure to either of the two substances. In conclusion, our in vitro experiments demonstrate that bentazon and isoproturon cross the skin barrier within 2 hours even at very low concentrations, and showed some signs of skin damage. Future tests involve concentrations found in commercial products.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Therapeutic strategies for essential tremor (ET) and Parkinson's disease (PD) can be divided into two successive steps, one based on oral medications and the other, more invasive, using pumps or functional neurosurgery. When ET becomes refractory to propranolol, primidone and other, second-choice compounds, deep brain stimulation of the VIM nucleus of the thalamus can be considered. When PD becomes resistant to dopamine replacement therapy using various combinations of dopaminergic agents, then three options can be discussed: first, a subcutaneous apomorphine mini-pump, second, a jejunal levodopa-delivery system by means of percutaneous gastrostomy, and third, bilateral deep brain stimulation of the subthalamic nucleus. The above interventions are successful in about 80% of cases.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND: Totally implanted vascular access devices are frequently used in children for repeated blood samples or intravenous treatments. This prospective study aims at identifying the risk factors associated with infections, obstructions and surgical complications of these devices in pediatric patients. METHODS: From January 2006 to January 2008, all children older than one year of age with a diagnosis of solid or blood cell malignancy were included in the study. Insertion was performed by the surgeon according to a standardized protocol after landmark-guided puncture of the subclavian or internal jugular vein by a senior anesthesiologist. Dressing and post-operative care were standardized. Every manipulation was prospectively recorded by specialized dedicated nurses, and all patients were screened for complications one month post-surgery. RESULTS: 45 consecutive patients 1 to 16 years old were enrolled in the study. Mean age at the time of procedure was 8.5 years (range 1.3-15.6; SD +/- 4.88). There were 12 peroperative adverse events in 45 procedures (27%), detailed as follows: 3 pneumothoraces (7%), 3 hematomas (7%), 6 arterial punctures (13%). Among these events, intervention was necessary for two pneumothorax and one arterial puncture. There was no air embolism. At one month, we recorded 5 post-operative complications (11%): 2 thrombotic obstructions, one unsightly scar, and one scapular pain of unknown etiology. One patient needed repositioning of the catheter. There was no catheter-related infection. CONCLUSION: Prospective recording of TIVA insertion in children reveals a significant number of early incidents and complications, mainly associated with the percutaneous puncture technique. We found no infection in this series. Results of a longer follow-up in the same population are pending.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Cardiospheres (CSs) are self-assembling multicellular clusters from the cellular outgrowth from cardiac explants cultured in nonadhesive substrates. They contain a core of primitive, proliferating cells, and an outer layer of mesenchymal/stromal cells and differentiating cells that express cardiomyocyte proteins and connexin 43. Because CSs contain both primitive cells and committed progenitors for the three major cell types present in the heart, that is, cardiomyocytes, endothelial cells, and smooth muscle cells, and because they are derived from percutaneous endomyocardial biopsies, they represent an attractive cell source for cardiac regeneration. In preclinical studies, CS-derived cells (CDCs) delivered to infarcted hearts resulted in improved cardiac function. CDCs have been tested safely in an initial phase-1 clinical trial in patients after myocardial infarction. Whether or not CDCs are superior to purified populations, for example, c-kit(+) cardiac stem cells, or to gene therapy approaches for cardiac regeneration remains to be evaluated.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: Heterogeneous results of single studies with photodynamic diagnosis (PDD) in bladder cancer have been reported. A metaanalysis of prospective studies has now been performed. Material and Methods: The effect of PDD in addition to WLC on a) the diagnosis and b) the therapeutic outcome of primary or recurrent non-muscle invasive bladder cancer (NMIBC) investigated by cystoscopy or transurethral resection was analysed. An electronic database search was performed. Trials were included if they prospectively compared WLC with PDD in bladder cancer. Primary endpoints were additional detection rate, residual tumour at second resection and recurrence-free survival. Results: Significantly more tumour-positive patients were detected with PDD in all patients with non-muscle invasive tumours (= 20%) [95% confidence interval (CI): 8 to 35%] and in CIS patients (= 39%) (CI: 23 to 57%). Residual tumour was significantly less often found after PDD (odds ratio 0.28, CI: 0.15 to 0.52, p<0.0001). Recurrence-free survival was significantly higher at 12 and 24months in the PDD groups than in WLC only groups. Conclusions: More bladder tumour-positive patients are detected by PDD. Best results were found in CIS patients. Diagnosis with PDD results in a more complete resection and a longer recurrence-free survival.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVES: A new caval tree system was designed for realistic in vitro simulation. The objective of our study was to assess cannula performance for virtually wall-less versus standard percutaneous thin-walled venous cannulas in a setting of venous collapse in case of negative pressure. METHODS: For a collapsible caval model, a very flexible plastic material was selected, and a model with nine afferent veins was designed according to the anatomy of the vena cava. A flow bench was built including a lower reservoir holding the caval tree, built by taking into account the main afferent vessels and their flow provided by a reservoir 6 cm above. A cannula was inserted in this caval tree and connected to a centrifugal pump that, in turn, was connected to a reservoir positioned 83 cm above the second lower reservoir (after-load = 60 mmHg). Using the same pre-load, the simulated venous drainage for cardiopulmonary bypass was realized using a 24 F wall-less cannula (Smartcanula) and 25 F percutaneous cannula (Biomedicus), and stepwise increased augmentation (1500 RPM, 2000 and 2500 RPM) of venous drainage. RESULTS: For the thin wall and the wall-less cannulas, 36 pairs of flow and pressure measurements were realized for three different RPM values. The mean Q-values at 1500, 2000 and 2500 RPM were: 3.98 ± 0.01, 6.27 ± 0.02 and 9.81 ± 0.02 l/min for the wall-less cannula (P <0.0001), versus 2.74 ± 0.02, 3.06 ± 0.05, 6.78 ± 0.02 l/min for the thin-wall cannula (P <0.0001). The corresponding inlet pressure values were: -8.88 ± 0.01, -23.69 ± 0.81 and -70.22 ± 0.18 mmHg for the wall-less cannula (P <0.0001), versus -36.69 ± 1.88, -80.85 ± 1.71 and -101.83 ± 0.45 mmHg for the thin-wall cannula (P <0.0001). The thin-wall cannula showed mean Q-values 37% less and mean P values 26% more when compared with the wall-less cannula (P <0.0001). CONCLUSIONS: Our in vitro water test was able to mimic a negative pressure situation, where the wall-less cannula design performs better compared with the traditional thin-wall cannula.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim of this master's thesis was to assess the ten- year trends and regional differences in management and outcome of acute myocardial infarction (AMI) within Switzerland. The thesis is composed of two articles. First, in the article "Trends in hospital management of acute myocardial infarction in Switzerland, 1998 to 2008" over 102,700 cases of AMI with corresponding management and revascularization procedures were assessed. The results showed a considerable increase in the numbers of hospital discharges for AMI, namely due to the increase of between- hospital transfers. Rates of intensive care unit admissions remained stable. All types of revascularization procedures showed an increase. In particular, overall stenting rates increased with drug-eluting stents partly replacing bare stents. Second, in the article "The region makes the difference: disparities in management of acute myocardial infarction within Switzerland" around 25,600 cases of AMI with corresponding management were assessed for the period of 2007-2008 and according to seven Swiss regions. As reported by our results, considerable regional differences in AMI management were stated within Switzerland. Although each region showed different trends regarding revascularization interventions, Leman and Ticino contrast significantly by presenting the minimum and maximum rates in almost all assessed parameters. As a consequence these two regions differ the most from the Swiss average. The impact of the changes in trends and the regional differences in AMI management on Swiss patient's outcome and economics remains to be assessed. Purpose: To assess ten-year trends in management and outcome of acute myocardial infarction (AMI) in Switzerland. Methods: Swiss hospital discharge database for the 1998 to 2008 period. AMI was defined as a primary discharge diagnosis code I21 according to the CIM-10 classification of the World Health Organization. Management and revascularization procedures were assessed. Results: Overall, 102,729 hospital discharges with a diagnosis of AMI were analyzed. The number of hospital discharges increased almost three-fold from 5530 in 1998 to 13,834 in 2008, namely due to a considerable increase in between-hospital transfers (1352 in 1998, 6494 in 2008). Relative to all hospital discharges, Intensive Care Unit admission rate was 38.0% in 1998 and remained stable (36.2%) in 2008 (p for trend=0.25). Percutaneous revascularization rates increased from 6.0% to 39.9% (p for trend<0.001). Non-drug-eluting stent use increased from 1.3% to 16.6% (p for trend<0.05). Drug eluting stents appeared in 2004 and increased to 23.5% of hospital discharges in 2008 (p for trend=0.07). Coronary artery bypass graft increased from 1.0% to 3.0% (p for trend<0.001). Circulatory assistance increased from 0.2% to 1.7% (p for trend<0.001). Thrombolysis showed no significant changes, from 0.5% to 1.9% (p for trend=0.64). Most of these trends were confirmed after multivariate adjustment. Conclusion: Between 1998 and 2008 the number of hospital discharges for AMI increased considerably in Switzerland, namely due to between-hospital transfers. Overall stenting rates increased, drug-eluting stents partly replacing bare stents. The impact of these changes on outcome and economics remains to be assessed.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Lymphangioleiomyomatosis is a rare pulmonary disease encountered almost exclusively in women of reproductive age. Pulmonary involvement is characterized by multiple thin-walled cysts in the lungs, recurrent pneumothorax, obstructive lung disorders, and progression to chronic respiratory failure over a mean period of 10 years. Certainty of diagnosis requires a lung biopsy, but international criteria have been proposed for a diagnosis without such a biopsy. International recommendations were recently issued for the diagnosis and treatment of lymphangioleiomyomatosis. Treatment is principally symptomatic and relies on the management of bronchial obstruction by bronchodilators; of hypoxemia by oxygen therapy; of pleural complications by pleurodesis, most often surgical; and of renal angiomyolipomas by percutaneous embolization in cases of hemorrhagic risk. Hormone treatment is not recommended. Hopes are high for mTor inhibitors (sirolimus and everolimus) and treatment trials are currently underway. Lung transplantation must be considered when chronic respiratory failure occurs in patients younger than 60 years.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVES: This study was designed to compare the long-term clinical outcome of coronary artery bypass grafting (CABG) with intracoronary stenting of patients with isolated proximal left anterior descending coronary artery. BACKGROUND: Although numerous trials have compared coronary angioplasty with bypass surgery, none assessed the clinical evaluation in the long term. METHODS: We evaluated the 10-year clinical outcome in the SIMA (Stent versus Internal Mammary Artery grafting) trial. Patients were randomly assigned to stent implantation versus CABG. RESULTS: Of 123 randomized patients, 59 underwent CABG and 62 received a stent (2 patients were excluded). Follow-up after 10 years was obtained for 98% of the randomized patients. Twenty-six patients (42%) in the percutaneous coronary intervention group and 10 patients (17%) in the CABG group reached an end point (p < 0.001). This difference was due to a higher need for additional revascularization. The incidences of death and myocardial infarction were identical at 10%. Progression of the disease requiring additional revascularization was rare (5%) and was similar for the 2 groups. Stent thrombosis occurred in 2 patients (3%). Angina functional class showed no significant differences between the 2 groups. CONCLUSIONS: Both stent implantation and CABG are safe and highly effective in relieving symptoms in patients with isolated, proximal left anterior descending coronary artery stenosis. Stenting with bare-metal stents is associated with a higher need for repeat interventions. The long-term prognosis for these patients is excellent with either mode of revascularization.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVES: This study sought to investigate whether self-expanding stents are more effective than balloon-expandable stents for reducing stent malapposition at 3 days after implantation in patients with ST-segment elevation myocardial infarction undergoing primary percutaneous coronary intervention. BACKGROUND: Acute myocardial infarction is associated with vasoconstriction and large thrombus burden. Resolution of vasoconstriction and thrombus load during the first hours to days after primary percutaneous coronary intervention may lead to stent undersizing and malapposition, which may subsequently lead to stent thrombosis or restenosis. In addition, aggressive stent deployment may cause distal embolization. METHODS: Eighty patients with ST-segment elevation myocardial infarction undergoing primary percutaneous coronary intervention were randomized to receive a self-expanding stent (STENTYS, STENTYS SA, Paris, France) (n = 43) or a balloon-expandable stent (VISION, Abbott Vascular, Santa Clara, California; or Driver, Medtronic, Minneapolis, Minnesota) (n = 37) at 9 European centers. The primary endpoint was the proportion of stent strut malapposition at 3 days after implantation measured by optical coherence tomography. Secondary endpoints included major adverse cardiac events (cardiac death, recurrent myocardial infarction, emergent bypass surgery, or clinically driven target lesion revascularization). RESULTS: At 3 days after implantation, on a per-strut basis, a lower rate of malapposed stent struts was observed by optical coherence tomography in the self-expanding stent group than in the balloon-expandable group (0.58% vs. 5.46%, p < 0.001). On a per-patient basis, none of the patients in the self-expanding stent group versus 28% in the balloon-expandable group presented ≥5% malapposed struts (p < 0.001). At 6 months, major adverse cardiac events were 2.3% versus 0% in the self-expanding and balloon-expandable groups, respectively (p = NS). CONCLUSIONS: Strut malapposition at 3 days is significantly lower in ST-segment elevation myocardial infarction patients allocated to self-expanding stents when than in those allocated to balloon-expandable stents. The impact of this difference on clinical outcome and the risk of late stent thrombosis need to be evaluated further. (Randomized Comparison Between the STENTYS Self-expanding Coronary Stent and a Balloon-expandable Stent in Acute Myocardial Infarction [APPOSITION II]; NCT01008085).

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND: Patients who have acute coronary syndromes with or without ST-segment elevation have high rates of major vascular events. We evaluated the efficacy of early clopidogrel administration (300 mg) (<24 hours) when given with aspirin in such patients. METHODS: We included 30,243 patients who had an acute coronary syndrome with or without ST segment elevation. Data on early clopidogrel administration were available for 24,463 (81%). Some 15,525 (51%) of the total cohort were administrated clopidogrel within 24h of admission. RESULTS: In-hospital death occurred in 2.9% of the patients in the early clopidogrel group treated with primary PCI and in 11.4% of the patients in the other group without primary percutaneous coronary intervention (PCI) and no early clopidogrel. The unadjusted clopidogrel odds ratio (OR) for mortality was 0.31 (95% confidence interval 0.27-0.34; p <0.001). Incidence of major adverse cardiac death (MACE) was 4.1% in the early clopidogrel group treated with 1°PCI and 13.5% in the other group without primary PCI and no early clopidogrel (OR 0.35, confidence interval 0.32-0.39, p <0.001). Early clopidogrel administration and PCI were the only treatment lowering mortality as shown by mutlivariate analysis. CONCLUSIONS: The early administration of the anti-platelet agent clopidogrel in patients with acute coronary syndromes with or without ST-segment elevation has a beneficial effect on mortality and major adverse cardiac events. The lower mortality rate and incidence of MACE emerged with a combination of primary PCI and early clopidogrel administration.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The parasellar region is the location of a wide variety of inflammatory and benign or malignant lesions. A pathological diagnostic strategy may be difficult to establish relying solely on imaging data. Percutaneous biopsy through the foramen ovale using the Hartel technique has been developed for decision-making process. It is an accurate diagnostic tool allowing pathological diagnosis to determine the best treatment strategy. However, in some cases, this procedure may fail or may be inappropriate particularly for anterior parasellar lesions. Over these past decades, endoscopy has been widely developed and promoted in many indications. It represents an interesting alternative approach to parasellar lesions with low morbidity when compared to the classic microscopic sub-temporal extradural approach with or without orbito-zygomatic removal. In this chapter, we describe our experience with the endoscopic approach to parasellar lesions. We propose a complete overview of surgical anatomy and describe methods and results of the technique. We also suggest a model of a decision-making tree for the diagnosis and treatment of parasellar lesions.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Object Recent years have been marked by efforts to improve the quality and safety of pedicle screw placement in spinal instrumentation. The aim of the present study is to compare the accuracy of the SpineAssist robot system with conventional fluoroscopy-guided pedicle screw placement. Methods Ninety-five patients suffering from degenerative disease and requiring elective lumbar instrumentation were included in the study. The robot cohort (Group I; 55 patients, 244 screws) consisted of an initial open robot-assisted subgroup (Subgroup IA; 17 patients, 83 screws) and a percutaneous cohort (Subgroup IB, 38 patients, 161 screws). In these groups, pedicle screws were placed under robotic guidance and lateral fluoroscopic control. In the fluoroscopy-guided cohort (Group II; 40 patients, 163 screws) screws were inserted using anatomical landmarks and lateral fluoroscopic guidance. The primary outcome measure was accuracy of screw placement on the Gertzbein-Robbins scale (Grade A to E and R [revised]). Secondary parameters were duration of surgery, blood loss, cumulative morphine, and length of stay. Results In the robot group (Group I), a perfect trajectory (A) was observed in 204 screws (83.6%). The remaining screws were graded B (n = 19 [7.8%]), C (n = 9 [3.7%]), D (n = 4 [1.6%]), E (n = 2 [0.8%]), and R (n = 6 [2.5%]). In the fluoroscopy-guided group (Group II), a completely intrapedicular course graded A was found in 79.8% (n = 130). The remaining screws were graded B (n = 12 [7.4%]), C (n = 10 [6.1%]), D (n = 6 [3.7%]), and E (n = 5 [3.1%]). The comparison of "clinically acceptable" (that is, A and B screws) was neither different between groups (I vs II [p = 0.19]) nor subgroups (Subgroup IA vs IB [p = 0.81]; Subgroup IA vs Group II [p = 0.53]; Subgroup IB vs Group II [p = 0.20]). Blood loss was lower in the robot-assisted group than in the fluoroscopy-guided group, while duration of surgery, length of stay, and cumulative morphine dose were not statistically different. Conclusions Robot-guided pedicle screw placement is a safe and useful tool for assisting spine surgeons in degenerative spine cases. Nonetheless, technical difficulties remain and fluoroscopy backup is advocated.