956 resultados para Operative procedures


Relevância:

20.00% 20.00%

Publicador:

Resumo:

INTRODUCTION: Preoperative scores are widely used predictors of complications after major surgery. These scores, however, are not widely used in transurethral procedures. The aim of this study was to assess the value of the Charlson Comorbidity Index (CCI), the age-adjusted CCI, the American Society of Anesthesiologist score (ASA) and the Nutritional Risk Score (NRS) in predicting early morbidity after transurethral urological procedures. METHODS: Consecutive patients undergoing transurethral resection of the bladder or the prostate were prospectively enrolled. The scores were calculated preoperatively; 30-day complications were prospectively recorded according to the Dindo-Clavien classification. Univariate logistic regression was performed to investigate the value of each score and of other factors (i.e., age, sex, body mass index, anemia, smoking habit, type of operation and anaesthesia) as predictors of complications. A multivariate model was then calculated using these predictors. RESULTS: Overall, 197 patients were included. The mean age was 72 (standard deviation ± 10). In total, 26.9% patients had at least 1 complication. Using univariate analysis, we found that each score significantly predicted complications. In multivariate analysis, only the ASA (odds ration [OR] 2.11; 95% confidence interval [CI] 1.01-4.43) and the NRS (OR 2.42; 95% CI 1.56-3.74) remained independent predictors. The best model incorporated ASA, NRS and gender, and predicted morbidity with an area under the curve of 76%. Our study's main limitations are population heterogeneity and limited sample size. CONCLUSION: The ASA and the NRS are important and independent determinants of early morbidity after transurethral procedures. The use of these indices may assist clinicians in the decision-making process to balance the possible benefits of transurethral procedures with the potential risks.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Työn tavoitteena oli selventää tietopääomaresurssien merkitys liiketoiminnassa riskien hallinnan kohteina. Tarkoitus oli määrittää eri tietopääomaresurssit ja niihin liittyviä riskejä. Tutkimus on kirjallisuustutkimus. Tutkimuksen tuloksena oli, että tietopääomaresursseihin kohdistuu erilaisia riskejä ja, että liiketoiminnalle tärkeät ja kriittiset tietopääomaresurssit ovat riskienhallinnan kohteita. Tutkimuksessa syntyi tietopääomaresurssien hallintamalli,jossa 1) toimintatapa yhdistää 2) osaamisen, 3) tiedot ja tietovarannot sekä 4) aineettomat oikeudet yhteneväiseksi kokonaisuudeksi. Tutkimuksessa kuvattiin kuhunkin resurssiin mahdollisesti liittyviä riskejä. Tutkimus osoitti, että liiketoiminnan tietopääomaresurssit voidaan tunnistaa ja niiden liiketoiminnallinen merkitys ja suojaustarve arvioida. Tietopääomaresurssien suojauskeinoja ovat yhteistyösopimukset, toimintatavat ja ohjeet sekä tietotekniset ja fyysiset suojausratkaisut.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This research has been focused at the development of a tuned systematic design methodology, which gives the best performance in a computer aided environment and utilises a cross-technological approach, specially tested with and for laser processed microwave mechanics. A tuned design process scheme is also presented. Because of the currently large production volumes of microwave and radio frequency mechanics even slight improvements of design methodologies or manufacturing technologies would give reasonable possibilities for cost reduction. The typical number of required iteration cycles could be reduced to one fifth of normal. The research area dealing with the methodologies is divided firstly into a function-oriented, a performance-oriented or a manufacturability-oriented product design. Alternatively various approaches can be developed for a customer-oriented, a quality-oriented, a cost-oriented or an organisation-oriented design. However, the real need for improvements is between these two extremes. This means that the effective methodology for the designers should not be too limited (like in the performance-oriented design) or too general (like in the organisation-oriented design), but it should, include the context of the design environment. This is the area where the current research is focused. To test the developed tuned design methodology for laser processing (TDMLP) and the tuned optimising algorithm for laser processing (TOLP), seven different industrial product applications for microwave mechanics have been designed, CAD-modelled and manufactured by using laser in small production series. To verify that the performance of these products meets the required level and to ensure the objectiveness ofthe results extensive laboratory tests were used for all designed prototypes. As an example a Ku-band horn antenna can be laser processed from steel in 2 minutes at the same time obtaining a comparable electrical performance of classical aluminium units or the residual resistance of a laser joint in steel could be limited to 72 milliohmia.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Meticulous steps and procedures are proposed in planning guidelines for the development of comprehensive multiyear plans for national immunization programmes. However, we know very little about whether the real-life experience of those who adopt these guidelines involves following these procedures as expected. Are these steps and procedures followed in practice? We examined the adoption and usage of the guidelines in planning national immunization programmes and assessed whether the recommendations in these guidelines are applied as consistently as intended. METHODS: We gathered information from the national comprehensive multiyear plans developed by 77 low-income countries. For each of the 11 components, we examined how each country applied the four recommended steps of situation analysis, problem prioritization, selection of interventions, and selection of indicators. We then conducted an analysis to determine the patterns of alignment of the comprehensive multiyear plans with those four recommended planning steps. RESULTS: Within the first 3 years following publication of the guidelines, 66 (86%) countries used the tool to develop their comprehensive multiyear plans. The funding conditions attached to the use of these guidelines appeared to influence their rapid adoption and usage. Overall, only 33 (43%) countries fully applied all four recommended planning steps of the guidelines. CONCLUSIONS: Adoption and usage of the guidelines for the development of comprehensive multiyear plans for national immunization programmes were rapid. However, our findings show substantial variation between the proposed planning ideals set out in the guidelines and actual use in practice. A better understanding of factors that influence how recommendations in public health guidelines are applied in practice could contribute to improvements in guidelines design. It could also help adjust strategies used to introduce them into public health programmes, with the ultimate goal of a greater health impact.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Enhanced Recovery After Surgery (ERAS) is a multimodal, standardized and evidence-based perioperative care pathway. With ERAS, postoperative complications are significantly lowered, and, as a secondary effect, length of hospital stay and health cost are reduced. The patient recovers better and faster allowing to reduce in addition the workload of healthcare providers. Despite the hospital discharge occurs sooner, there is no increased charge of the outpatient care. ERAS can be safely applied to any patient by a tailored approach. The general practitioner plays an essential role in ERAS by assuring the continuity of the information and the follow-up of the patient.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Since January 2008-de facto 2012-medical physics experts (MPEs) are, by law, to be involved in the optimisation process of radiological diagnostic procedures in Switzerland. Computed tomography, fluoroscopy and nuclear medicine imaging units have been assessed for patient exposure and image quality. Large spreads in clinical practice have been observed. For example, the number of scans per abdominal CT examination went from 1 to 9. Fluoroscopy units showed, for the same device settings, dose rate variations up to a factor of 3 to 7. Quantitative image quality for positron emission tomography (PET)/CT examinations varied significantly depending on the local image reconstruction algorithms. Future work will be focused on promoting team cooperation between MPEs, radiologists and radiographers and on implementing task-oriented objective image quality indicators.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVES: This is the first meta-analysis on the efficacy of composite resin restorations in anterior teeth. The objective of the present meta-analysis was to verify whether specific material classes, tooth conditioning methods and operational procedures influence the result for Class III and Class IV restorations. MATERIAL AND METHODS: The database SCOPUS and PubMed were searched for clinical trials on anterior resin composites without restricting the search to the year of publication. The inclusion criteria were: (1) prospective clinical trial with at least 2 years of observation; (2) minimal number of restorations at last recall=20; (3) report on drop-out rate; (4) report of operative technique and materials used in the trial, and (5) utilization of Ryge or modified Ryge evaluation criteria. For the statistical analysis, a linear mixed model was used with random effects to account for the heterogeneity between the studies. p-Values smaller than 0.05 were considered to be significant. RESULTS: Of the 84 clinical trials, 21 studies met the inclusion criteria, 14 of them for Class III restorations, 6 for Class IV restorations and 1 for closure of diastemata; the latter was included in the Class IV group. Twelve of the 21 studies started before 1991 and 18 before 2001. The estimated median overall success rate (without replacement) after 10 years for Class III composite resin restorations was 95% and for Class IV restorations 90%. The main reason for the replacement of Class IV restorations was bulk fractures, which occurred significantly more frequently with microfilled composites than with hybrid and macrofilled composites. Caries adjacent to restorations was infrequent in most studies and accounted only for about 2.5% of all replaced restorations after 10 years irrespective of the cavity class. Class III restorations with glass ionomer derivates suffered significantly more loss of anatomical form than did fillings with other types of material. When the enamel was acid-etched and no bonding agent was applied, significantly more restorations showed marginal staining and detectable margins compared to enamel etching with enamel bonding or the total etch technique; fillings with self-etching systems were in between of these two outcome variables. Bevelling of the enamel was associated with a significantly reduced deterioration of the anatomical form compared to no bevelling but not with less marginal staining or less detectable margins. The type of isolation (absolute/relative) had a statistically significant influence on marginal caries which, however, might be a random finding.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

La stimulation cérébrale profonde (SCP) nécessite l'implantation chirurgicale d'un système comprenant électrodes cérébrales et boîtier(s) de stimulation. Les noyaux cérébraux visés par la méthodologie stéréotaxique d'implantation doivent être visualisés au mieux par une imagerie à haute résolution. La procédure chirurgicale d'implantation des électrodes se fait si possible en anesthésie locale pour faire des mesures électro-physiologiques et tester en peropératoire l'effet de la stimulation, afin d'optimiser la position de l'électrode définitive. Dans un deuxième temps, le ou les générateur(s) d'impulsions sont implantés en anesthésie générale. La SCP pour les mouvements anormaux a une très bonne efficacité et un risque de complications graves faible quoique non nul. Les complications liées au matériel sont les plus fréquentes. Deep brain stimulation (DBS) requires the surgical implantation of a system including brain electrodes and impulsion generator(s). The nuclei targeted by the stereotaxic implantation methodology have to be visualized at best by high resolution imaging. The surgical procedure for implanting the electrodes is performed if possible under local anaesthesia to make electro-physiological measurements and to test intra-operatively the effect of the stimulation, in order to optimize the position of the definitive electrode. In a second step, the impulsion generator(s) are implanted under general anaesthesia. DBS for movement disorders has a very good efficacy and a low albeit non-zero risk of serious complications. Complications related to the material are the most common.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Tämän tutkintotyön tavoitteena on selvittää operatiivista ostotoimintaa, joka sisältää oikea-aikaisen tilausrytmin ja tasapainoisen tilausmäärän määrityksen sekä saapuvan tavaravirran mukauttamisen myyntiin tai kulutukseen kokonaisuutena. Tässä tutkimuksessa tarkastellaan myös varastojen merkitystä ja ostotoiminnan kannalta keskeisimpiä tehokkaaseen varastonohjaukseen liittyviä tunnuslukuja. Tutkimus sisältää lääkkeiden toimitusketjun kuvauksen, koska se poikkeaa merkittävästi muista toimialoista. Tämä tutkintotyö on syntetisoiva kirjallisuustutkimus. Tutkintotyön empiirisessä osassa analysoidaan aluksi case-yrityksen vaihto-omaisuusvaraston ohjausta ostotoiminnan näkökulmasta ABC analyysiin pohjautuen. Tämän jälkeen ostotoimintaa analysoidaan tarkemmin tiettyjen toimittajien osalta. Lopuksi laaditaan optimaalinen tilausrytmi ja tilausmäärät sekä ostobudjetti yhden toimittajan tuotteille. ABC analyysia voidaan hyödyntää työkaluna määriteltäessä miten erilaisten tuotteiden materiaalivirtoja tulisi ostotoiminnan kannalta ohjata. Analyysi perustuu resurssien keskittämiseen sinne missä tuotto on suurin.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Radial maze tasks have been used to assess optimal foraging and spatial abilities in rodents. The spatial performance was based on a capacity to rely on a configuration of local and distant cues. We adapted maze procedures assessing the relative weight of local cues and distant landmarks for arm choice in humans. NEW METHOD: The procedure allowed testing memory of places in four experimental setups: a fingertip texture-groove maze, a tactile screen maze, a virtual radial maze and a walking size maze. During training, the four reinforced positions remained fixed relative to local and distal cues. During subsequent conflict trials, these frameworks were made conflictive in the prediction of reward locations. RESULTS: Three experiments showed that the relative weight of local and distal relational cues is affected by different factors such as cues' nature, visual access to the environment, real vs. virtual environment, and gender. A fourth experiment illustrated how a walking maze can be used with people suffering intellectual disability. COMPARISON WITH EXISTING METHODS: In our procedure, long-term (reference) and short-term (working) memory can be assessed. It is the first radial task adapted to human that enables dissociating local and distal cues, to provides an indication as to their relative salience. Our mazes are moveable and easily used in limited spaces. Tasks are performed with realistic and spontaneous though controlled exploratory movements. CONCLUSION: Our tasks enabled highlighting the use of different strategies. In a clinical perspective, considering the use of compensatory strategies should orient towards adapted behavioural rehabilitation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVES: Transapical transcatheter valve procedures are performed through a left minithoracotomy and require apical sutures to seal the apical access site. The use of large-calibre devices compromises any attempt to fully perform the procedure with a thoracoscopic approach or percutaneously. We report our preliminary experience in animals with a new sutureless self-expandable apical occluder, engineered to perform transapical access site closure in a minimally invasive setting with large-size introducer sheaths. METHODS: The apical occluder with extendable waist was implanted in six young pigs during an acute animal study. Under general anaesthesia, animals (mean weight: 62 ± 8 kg) received full heparinization (heparin: 100 UI/kg; activated clotting time above 250 s). Through a median sternotomy, a 21-Fr Certitude? introducer sheath (outer diameter: 25 Fr) was placed over the wire into the cardiac apex. The delivery catheter carrying the constrained apical plug was inserted into the sheath and deployed under fluoroscopic control, whereas the Certitude? was retrieved. After protamine infusion, we observed and recorded the 1-h bleeding with standard haemodynamic parameters. Animals were sacrificed, and hearts analysed. RESULTS: Six apical closure devices were successfully introduced and deployed in six pig hearts through large-size apical sheaths at first attempt. In all animals, the plugs guaranteed immediate apical sealing and traces of blood were collected in the pericardium during the 1-h observational period (mean of 16 ± 3.4 ml of blood loss per animal). Haemodynamic parameters remained stable during the entire study period and no plug dislodgement was detected with normal systemic blood pressure (mean arterial mean blood pressure: 65 ± 7 mmHg). Post-mortem analysis confirmed the full deployment and good fixation of all plugs, without macroscopic damages to the surrounding myocardium. CONCLUSIONS: This sutureless self-expandable apical occluder is a simple device capable of sealing large-size apical access sites (20-35 Fr) in an acute animal study. This approach is a step further towards less invasive transapical valve procedures in the clinical setting, and further animal tests will be performed to confirm the long-term efficacy and safety of this device.