964 resultados para OC
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Thermal spray WC-based coatings are widely used in the aircraft industry mainly for their resistance to wear, reworking and rebuilding operations and repair of worn components on landing gear, hydraulic cylinders, actuators, propeller hub assemblies, gas turbine engines, and so on. The aircraft industry is also trying to use thermal spray technology to replace electroplating coatings such as hard chromium. In the present work, WC-Co coatings were built up on an AA 7050 aluminum alloy using high velocity oxygen fuel (HVOF) technology and a liquid nitrogen cooling prototype system. The influence of the spray parameters (standard conditions, W19S, increasing the oxygen flux, W19H, and also increasing the carrier gas flux, W19F) on corrosion, friction, and abrasive wear resistance were also studied. The coatings were characterized using optical (OM) and scanning electron (SEM) microscopy, and X-ray diffraction (XRD). The friction and abrasive wear resistance of the coatings were studied using Rubber Wheel and Ball on Disk tests. The electrochemical studies were conducted using open-circuit potential (E(oc)) measurements and electrochemical impedance spectroscopy (EIS). Differences among coated samples were mainly related to the variation of the thermal spray parameters used during the spray process. No significant differences were observed in the wear resistance for the coatings studied, and all of them showed a wear rate around 10 times lower than that of the aluminum alloy. The results of mass loss and wear rate were interpreted considering different mechanisms. Comparing the different spray parameters, the oxygen flux (higher flame temperature) produced the sample which showed the highest corrosion resistance in aerated and unstirred 3.5% NaCl solution. Aluminum ions were detected on the surface almost immediately after the immersion of samples W19S and W19F in chloride solution, showing that the electrolyte reached the substrate and galvanic corrosion probably occurred. For sample W19H, aluminum ions were not detected even after 120 min of immersion in NaCl solution. (C) 2008 Elsevier B.V. All rights reserved.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
A produção de peixes em tanques-rede no Brasil tem aumentado nas últimas décadas. O baixo investimento inicial e o potencial hídrico representado pela enorme quantidade de água represada em nosso País têm atraído o interesse de empresários para essa atividade. O objetivo desse trabalho foi gerar informações sobre o efeito da densidade de estocagem no crescimento e produtividade da tilápia vermelha da Flórida criadas em tanques-rede. Foram instalados doze tanques-rede de 5 m3, numa represa de 1 ha, e estocados com 25, 50, 75 e 100 tilápias vermelhas da Flórida revertidas por m3. Os peixes foram alimentados com rações extrusadas comerciais contendo 32 e 28% PB por 253 dias. As temperaturas máxima, mínima e média da água foram 32,2, 16,0 e 23,9 C, respectivamente. Também foram monitorados a condutividade (58 mS/cm2), alcalinidade total (28 mg/L), amônia não ionizada (0,26 mg/L), nitrito (0,02 mg/L), oxigênio dissolvido (4,1 mg/L) e transparência da água (37 cm). Foram determinados o peso médio final (279,54g), comprimento padrão médio final (18,72cm), fator de condição (4,12), conversão alimentar aparente (3,15), taxa de sobrevivência (96,9%), ganho de peso diário (0,92g), taxa de crescimento específico (0,70%) e coeficientes de variação do peso (0,357%), do comprimento padrão (0,136%) e do fator de condição (0,136%). Não foram observadas diferenças significativas (P>0,05) entre as densidades de estocagem testadas nesses parâmetros. A densidade de estocagem de 100 peixes/m3 proporcionou a maior biomassa por m3 (P<0,001).
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Well-fitted dentures prevent hyperplasic lesions, provide chewing efficiency and promote patient's comfort. Several factors may affect final adaptation of dentures, as the type of the acrylic resin, the flask cooling procedure and the water uptake. This investigation evaluated the effect of water storage and two different cooling procedures [bench cooling (BC) for 2 h; running water (RW) at 20 degreesC for 45 min] on the final adaptation of denture bases. A heat-cured acrylic resin (CL, Classico, Classico Artigos Odontologicos) and two microwave-cured acrylic resins [Acron MC, (AC) GC Dent. Ind. Corp.; Onda Cryl (OC), Classico Artigos Odontologicos] were used to make the bases. Adaptation was assessed by measuring the weight of an intervening layer of silicone impression material between the base and the master die. Data was submitted to ANOVA and Tukey's test (0.05). The following means were found: (BC) CL=0.72 +/- 0.03 a; AC=0.70 +/- 0.03 b; OC=0.76 +/- 0.04 c//(RW) CL= 1.00 +/- 0.11 a; AC=1.00 +/- 0.12 a; OC=0.95 +/- 0.10 a. Different labels join groups that are not statistically different (P > 0.05). Comparisons are made among groups submitted to the same cooling procedure (BC or RW). The conclusions are: interaction of type of material and cooling procedure had a statistically significant effect on the final adaptation of the denture bases (P < 0.05); water storage was not detected as a source of variance (P > 0.05) on the final adaptation.
Resumo:
The goal of this work was to establish comparisons among environmental degradation in different areas from Southern Spain (Gulf of Cadiz) and Brazil (Santos and Sao Vicente estuary), by using principal component analyses (PCA) to integrate sediment toxicity (amphipods mortality) and chemical-physical data (Zn, Cd, Pb; Cu, Ni, Co, V, PCBs, PAHs concentrations, OC and fines contents). The results of PCA extraction of Spanish data showed that Bay of Cadiz, CA-1 did not present contamination or degradation; CA-2 exhibited contamination by PCBs, however it was not related to the amphipods mortality. Ria of Huelva was the most impacted site, showing contamination caused principally by hydrocarbons, in HV-1 and HV-2, but heavy metals were also important contaminants at HV-1, HV-2 and HV-3. Algeciras Bay was considered as not degraded in GR-3 and -4, but in GR-3' high contamination by PAHs was found. In the Brazilian area, the most degraded sediments were found in the stations situated at the inner parts of the estuary (SSV-2, SSV-3, and SSV-4), followed by SSV-6, which is close to the Submarine Sewage Outfall of Santos - SSOS. Sediments from SSV-1 and SSV-5 did not present chemical contamination, organic contamination or significant amphipod mortality. The results, of this investigation showed that both countries present environmental degradation related to PAHs: in Spain, at Ria of Huelva and Gudarranque river's estuary areas; and in Brasil, in the internal portion of the Santos and Sao Vicente estuary. The same situation is found for heavy metals, since all of the identified metals are related to toxicity in the studied areas, with few exceptions (V for both Brazil and Spain, and Cd and Co for Brazilian areas). The contamination by PCBs is more serious for Santos and Sao Vicente estuary than for the investigated areas in Gulf of Cadiz, where such compound did not relate to the toxicity. (c) 2006 Elsevier Ltd. All rights reserved.
Environmental Behaviour of Metolachlor and Diuron in a Tropical Soil in the Central Region of Brazil
Resumo:
The environmental behaviour of metolachlor and diuron was studied in the Central-western region of Brazil, by means of a field study where six experimental plots were installed. The soil was classified as a Latosol, and the soil horizons were characterized. Sorption of metolachlor and diuron was evaluated in laboratory batch experiments. Metolachlor and diuron were applied to the experimental plots on uncultivated soil in October 2003. From this date to March 2004, the following processes were studied: leaching, runoff and dissipation in top soil. K (oc) of metolachlor varied from 179 to 264 mL g(-1) in the soil horizons. K (oc) of diuron in the Ap horizon was 917 mL g(-1), decreasing significantly in the deeper horizons. Field dissipation half-lives of metolachlor and diuron were 18 and 15 days, respectively. In percolated water, metolachlor was detected in concentrations ranging from 0.02 to 2.84 mu g L-1. In runoff water and sediment, metolachlor was detected in decreasing concentrations throughout the period of study. Losses of 0.02% and 0.54% of the applied amount by leaching and runoff, respectively, were observed confirming the high mobility of this herbicide in the environment. In percolated water, diuron was detected with low frequency but in relatively high concentrations (up to 6.29 mu g L-1). In runoff water and soil, diuron was detected in decreasing concentrations until 70 days after application, totalizing 13.9% during the whole sampling period. These results show the importance of practices to reduce runoff avoiding surface water contamination by these pesticides, particularly diuron.
Resumo:
Hydrogen interaction with oxide films grown on iron electrodes at open circuit potential (E-oc) and in the passive region (+0.30 V-ECS) was studied by chronopotentiometry, chronoamperometry and electrochemical impedance spectroscopy techniques. The results were obtained in deaerated 0.3 mol L-1 H3BO3 + 0.075 mol L-1 Na2B4O7 (BB, pH 8.4) solution before, during and after hydrogen permeation. The iron oxide film modification was also investigated by means of in situ X-ray absorption near-edge spectroscopy (XANES) and scanning electrochemical microscopy (SECM) before and during hydrogen permeation. The main conclusion was that the passive film is reduced during the hydrogen diffusion. The hydrogen permeation stabilizes the iron surface at a potential close to the thermodynamic water stability line where hydrogen evolution can occur. The stationary condition required for the determination of the permeation parameters cannot be easily attained on iron surface during hydrogen permeation. Moreover, additional attention must be paid when obtaining the transport parameters using the classical permeation cell. (c) 2007 Elsevier Ltd. All rights reserved.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Thermal spray coatings as Cr3C2-NiCr obtained by high velocity oxy-fuel spraying (HVOF) are mainly applied due to their behaviour against aggressive erosive-abrasive and corrosive atmospheres and their thermal stability at high temperatures [1]. In order to increase the corrosion protection that it offers to the substrate trying to close the interconnected pores, it is possible to apply a thermal treatment with the gun during the spraying of the coating. This treatment could be applied in different ways. One of these ways consists of spraying only a few layers of coating followed by thermal treatment and finally the spray of the rest of layers. This thermal treatment on spraying is studied related to the corrosion properties of the system. The study comprises the electrochemical characterisation of the system by open circuit potential (OC), polarisation resistance (Rp), cyclic voltammetry (CV) and impedance spectroscopy measurements (EIS). Optical and scanning electron microscopy characterisation (OM and SEM) of the top and cross-section of the system has been used in order to justify the electrochemical results.
Resumo:
Sparfloxacin, a third-generation fluoroquinolone, is a potent antibacterial agent against a wide range of Gram-positive and Gram-negative organisms, for example Streptococcus pneumonias, Staphylococcus aureus (including methicillin-resistant strains), Legionella spp., Mycoplasma spp., Chlamydia spp. and Mycobacterium spp. This compound has been submitted to thermal analysis and the results are presented here. The DSC curve of sparfloxacin has an endothermic peak that indicates a melting point at 276.5 °C. The DTA curve of the sample in synthetic air shows two exothermic peaks, at 341.6 and 579.2 °C, attributed to compound decomposition. In the TG curve, the loss of mass can be seen to occur in two steps between 285.5 and 645.3 °C. The DTA curve obtained in a nitrogen atmosphere shows an exothermic peak, with decomposition of sparfloxacin at 340.0 °C; from the corresponding TG plot, the loss of mass starts at 254.4 °C.