946 resultados para Non invasive methods
Resumo:
OBJECTIVES To establish an effective alfaxalone concentration to be used for bath immersion of fire-bellied toads (Bombina orientalis) and to describe its effects. STUDY DESIGN Prospective experimental study. ANIMALS Thirteen oriental fire-bellied toads. METHODS The study was carried out in two phases. The pilot phase involved five animals and aimed to identify an alfaxalone concentration capable of producing induction of anesthesia, defined as immobility with a head down position and loss of responsiveness to stimulation with a stick. The following trial in an additional eight toads used the effective alfaxalone concentration established during the pilot phase. Data from 11 animals (three toads in the pilot study and the eight additional toads) were analyzed. Twenty minutes after immersion in the anesthetic solution, the toads were removed from the bath, and heart rate, respiratory rate, the righting, myotactic and the nociceptive withdrawal reflexes were evaluated every 5 minutes. The loss of both righting and nociceptive withdrawal reflexes was considered indicative of a surgical depth of anesthesia. The time elapsed from anesthetic induction to return of righting reflex, the quality of recovery and the occurrence of undesired effects were observed and recorded. RESULTS Immersion was found to be a suitable anesthetic technique for oriental fire-bellied toads and 200 mg L(-1) alfaxalone concentration produced anesthetic induction in 10 out of 11 toads. Side effects, such as skin irritation, erythema and changes in cutaneous pigmentation, were not observed in any animal. The duration of anesthesia ranged from 10 to 30 minutes after removal of the toads from the alfaxalone bath, and surgical depth of anesthesia was never achieved. CONCLUSIONS AND CLINICAL RELEVANCE It was concluded that alfaxalone anesthesia induced by immersion in a concentration of 200 mg L(-1) is only suitable for toads undergoing non-invasive short procedures.
Resumo:
OBJECTIVES Evaluation of computed tomography (CT) and magnetic resonance imaging (MRI) for differentiation of pancreatic intraductal papillary mucinous neoplasm (IPMN) subtypes based on objective imaging criteria. METHODS Fifty-eight patients with 60 histologically confirmed IPMNs were included in this retrospective study. Eighty-three imaging studies (CT,n = 42; MRI,n = 41) were analysed by three independent blinded observers (O1-O3), using established imaging criteria to assess likelihood of malignancy (-5, very likely benign; 5, very likely malignant) and histological subtype (i.e., low-grade (LGD), moderate-grade (MGD), high-grade dysplasia (HGD), early invasive carcinoma (IPMC), solid carcinoma (CA) arising from IPMN). RESULTS Forty-one benign (LGD IPMN,n = 20; MGD IPMN,n = 21) and 19 malignant (HGD IPMN,n = 3; IPMC,n = 6; solid CA,n = 10) IPMNs located in the main duct (n = 6), branch duct (n = 37), or both (n = 17) were evaluated. Overall accuracy of differentiation between benign and malignant IPMNs was 86/92 % (CT/MRI). Exclusion of overtly malignant cases (solid CA) resulted in overall accuracy of 83/90 % (CT/MRI). The presence of mural nodules and ductal lesion size ≥30 mm were significant indicators of malignancy (p = 0.02 and p < 0.001, respectively). CONCLUSIONS Invasive IPMN can be identified with high confidence and sensitivity using CT and MRI. The diagnostic problem that remains is the accurate radiological differentiation of premalignant and non-invasive subtypes. KEY POINTS • CT and MRI can differentiate benign from malignant forms of IPMN. • Identifying (pre)malignant histological IPMN subtypes by CT and MRI is difficult. • Overall, diagnostic performance with MRI was slightly (not significantly) superior to CT.
Resumo:
BACKGROUND To investigate anterior scleral thickness in a cohort of healthy subjects using enhanced depth imaging anterior segment optical coherence tomography. METHODS Observational case series. The mean scleral thickness in the inferonasal, inferotemporal, superotemporal, and superonasal quadrant was measured 2 mm from the scleral spur on optical coherence tomography in healthy volunteers. RESULTS Fifty-three eyes of 53 Caucasian patients (25 male and 28 female) with an average age of 48.6 years (range: 18 to 92 years) were analysed. The mean scleral thickness was 571 μm (SD 84 μm) in the inferonasal quadrant, 511 μm (SD 80 μm) in the inferotemporal quadrant, 475 (SD 81 μm) in the superotemporal, and 463 (SD 64 μm) in the superonasal quadrant. The mean scleral thickness was significantly different between quadrants (p < 0.0001, repeated measures one-way ANOVA). The association between average scleral thickness and age was statistically significant (p < 0.0001, Pearson r = 0.704). CONCLUSIONS Enhanced depth imaging optical coherence tomography revealed the detailed anatomy of the anterior sclera and enabled non-invasive measurements of scleral thickness in a non-contact approach. The anterior scleral thickness varies significantly between quadrants, resembling the spiral of Tillaux. An association of increasing scleral thickness with age was found.
Resumo:
BACKGROUND The frequent expression of neurotensin receptors (NT-R) in primaries of pancreatic ductal carcinomas has triggered the development of radioactive neurotensin analogs for possible in vivo targeting of these tumors. However, the complete lack of information regarding NT-R in liver metastases of pancreatic cancer and pancreatic intraepithelial neoplasia (PanIN) makes an in vitro study of NT-R in these tissues indispensable. METHODS Using in vitro receptor autoradiography with (125)I-[Tyr(3)]-neurotensin, NT-R were investigated in 18 primaries and 23 liver metastases of pancreatic ductal carcinomas as well as in 19 PanIN lesions. RESULTS We report here that 13 of 18 ductal carcinoma primaries and 14 of 23 liver metastases expressed NT-R. Moreover, none of the six PanIN 1B cases expressed NT-R, while two of six PanIN 2 and five of seven PanIN 3 expressed NT-R. Binding was fully displaced by the type 1 NT-R-selective antagonist SR48692, indicating that the NT-R in the tumors are of the type 1 NT-R subtype. CONCLUSIONS These in vitro data extend the currently available information on NT-R in invasive and non-invasive pancreatic ductal tumors. They suggest that type 1 NT-R may be a novel, specific marker of PanIN of higher degree. The high expression of NT-R in primaries and metastases of invasive cancer strongly support the need to develop radioactive neurotensin analogs for the diagnosis and therapy of this tumor type.
Resumo:
OBJECTIVE Spontaneous intracranial hypotension (SIH) is most commonly caused by cerebrospinal fluid (CSF) leakage. Therefore, we hypothesised that patients with orthostatic headache (OH) would show decreased optic nerve sheath diameter (ONSD) during changes from supine to upright position. METHODS Transorbital B-mode ultrasound was performed employing a high-frequency transducer for ONSD measurements in the supine and upright positions. Absolute values and changes of ONSD from supine to upright were assessed. Ultrasound was performed in 39 SIH patients, 18 with OH and 21 without OH, and in 39 age-matched control subjects. The control group comprised 20 patients admitted for back surgery without headache or any orthostatic symptoms, and 19 healthy controls. RESULTS In supine position, mean ONSD (±SD) was similar in patients with (5.38±0.91 mm) or without OH (5.48±0.89 mm; p=0.921). However, in upright position, mean ONSD was different between patients with (4.84±0.99 mm) and without OH (5.53±0.99 mm; p=0.044). Furthermore, the change in ONSD from supine to upright position was significantly greater in SIH patients with OH (-0.53±0.34 mm) than in SIH patients without OH (0.05±0.41 mm; p≤0.001) or in control subjects (0.01±0.38 mm; p≤0.001; area under the curve: 0.874 in receiver operating characteristics analysis). CONCLUSIONS Symptomatic patients with SIH showed a significant decrease of ONSD, as assessed by ultrasound, when changing from the supine to the upright position. Ultrasound assessment of the ONSD in two positions may be a novel, non-invasive tool for the diagnosis and follow-up of SIH and for elucidating the pathophysiology of SIH.
Resumo:
Until today, most of the documentation of forensic relevant medical findings is limited to traditional 2D photography, 2D conventional radiographs, sketches and verbal description. There are still some limitations of the classic documentation in forensic science especially if a 3D documentation is necessary. The goal of this paper is to demonstrate new 3D real data based geo-metric technology approaches. This paper present approaches to a 3D geo-metric documentation of injuries on the body surface and internal injuries in the living and deceased cases. Using modern imaging methods such as photogrammetry, optical surface and radiological CT/MRI scanning in combination it could be demonstrated that a real, full 3D data based individual documentation of the body surface and internal structures is possible in a non-invasive and non-destructive manner. Using the data merging/fusing and animation possibilities, it is possible to answer reconstructive questions of the dynamic development of patterned injuries (morphologic imprints) and to evaluate the possibility, that they are matchable or linkable to suspected injury-causing instruments. For the first time, to our knowledge, the method of optical and radiological 3D scanning was used to document the forensic relevant injuries of human body in combination with vehicle damages. By this complementary documentation approach, individual forensic real data based analysis and animation were possible linking body injuries to vehicle deformations or damages. These data allow conclusions to be drawn for automobile accident research, optimization of vehicle safety (pedestrian and passenger) and for further development of crash dummies. Real 3D data based documentation opens a new horizon for scientific reconstruction and animation by bringing added value and a real quality improvement in forensic science.
Resumo:
Abstract: Near-infrared spectroscopy (NIRS) enables the non-invasive measurement of changes in hemodynamics and oxygenation in tissue. Changes in light-coupling due to movement of the subject can cause movement artifacts (MAs) in the recorded signals. Several methods have been developed so far that facilitate the detection and reduction of MAs in the data. However, due to fixed parameter values (e.g., global threshold) none of these methods are perfectly suitable for long-term (i.e., hours) recordings or were not time-effective when applied to large datasets. We aimed to overcome these limitations by automation, i.e., data adaptive thresholding specifically designed for long-term measurements, and by introducing a stable long-term signal reconstruction. Our new technique (“acceleration-based movement artifact reduction algorithm”, AMARA) is based on combining two methods: the “movement artifact reduction algorithm” (MARA, Scholkmann et al. Phys. Meas. 2010, 31, 649–662), and the “accelerometer-based motion artifact removal” (ABAMAR, Virtanen et al. J. Biomed. Opt. 2011, 16, 087005). We describe AMARA in detail and report about successful validation of the algorithm using empirical NIRS data, measured over the prefrontal cortex in adolescents during sleep. In addition, we compared the performance of AMARA to that of MARA and ABAMAR based on validation data.
Resumo:
INTRODUCTION Dexmedetomidine was shown in two European randomized double-blind double-dummy trials (PRODEX and MIDEX) to be non-inferior to propofol and midazolam in maintaining target sedation levels in mechanically ventilated intensive care unit (ICU) patients. Additionally, dexmedetomidine shortened the time to extubation versus both standard sedatives, suggesting that it may reduce ICU resource needs and thus lower ICU costs. Considering resource utilization data from these two trials, we performed a secondary, cost-minimization analysis assessing the economics of dexmedetomidine versus standard care sedation. METHODS The total ICU costs associated with each study sedative were calculated on the basis of total study sedative consumption and the number of days patients remained intubated, required non-invasive ventilation, or required ICU care without mechanical ventilation. The daily unit costs for these three consecutive ICU periods were set to decline toward discharge, reflecting the observed reduction in mean daily Therapeutic Intervention Scoring System (TISS) points between the periods. A number of additional sensitivity analyses were performed, including one in which the total ICU costs were based on the cumulative sum of daily TISS points over the ICU period, and two further scenarios, with declining direct variable daily costs only. RESULTS Based on pooled data from both trials, sedation with dexmedetomidine resulted in lower total ICU costs than using the standard sedatives, with a difference of €2,656 in the median (interquartile range) total ICU costs-€11,864 (€7,070 to €23,457) versus €14,520 (€7,871 to €26,254)-and €1,649 in the mean total ICU costs. The median (mean) total ICU costs with dexmedetomidine compared with those of propofol or midazolam were €1,292 (€747) and €3,573 (€2,536) lower, respectively. The result was robust, indicating lower costs with dexmedetomidine in all sensitivity analyses, including those in which only direct variable ICU costs were considered. The likelihood of dexmedetomidine resulting in lower total ICU costs compared with pooled standard care was 91.0% (72.4% versus propofol and 98.0% versus midazolam). CONCLUSIONS From an economic point of view, dexmedetomidine appears to be a preferable option compared with standard sedatives for providing light to moderate ICU sedation exceeding 24 hours. The savings potential results primarily from shorter time to extubation. TRIAL REGISTRATION ClinicalTrials.gov NCT00479661 (PRODEX), NCT00481312 (MIDEX).
Resumo:
BACKGROUND Patients with downbeat nystagmus syndrome suffer from oscillopsia, which leads to an unstable visual perception and therefore impaired visual acuity. The aim of this study was to use real-time computer-based visual feedback to compensate for the destabilizing slow phase eye movements. METHODS The patients were sitting in front of a computer screen with the head fixed on a chin rest. The eye movements were recorded by an eye tracking system (EyeSeeCam®). We tested the visual acuity with a fixed Landolt C (static) and during real-time feedback driven condition (dynamic) in gaze straight ahead and (20°) sideward gaze. In the dynamic condition, the Landolt C moved according to the slow phase eye velocity of the downbeat nystagmus. The Shapiro-Wilk test was used to test for normal distribution and one-way ANOVA for comparison. RESULTS Ten patients with downbeat nystagmus were included in the study. Median age was 76 years and the median duration of symptoms was 6.3 years (SD +/- 3.1y). The mean slow phase velocity was moderate during gaze straight ahead (1.44°/s, SD +/- 1.18°/s) and increased significantly in sideward gaze (mean left 3.36°/s; right 3.58°/s). In gaze straight ahead, we found no difference between the static and feedback driven condition. In sideward gaze, visual acuity improved in five out of ten subjects during the feedback-driven condition (p = 0.043). CONCLUSIONS This study provides proof of concept that non-invasive real-time computer-based visual feedback compensates for the SPV in DBN. Therefore, real-time visual feedback may be a promising aid for patients suffering from oscillopsia and impaired text reading on screen. Recent technological advances in the area of virtual reality displays might soon render this approach feasible in fully mobile settings.
Resumo:
Stable coronary artery disease is the most common clinical manifestation of ischaemic heart disease and a leading cause of mortality worldwide. Myocardial revascularisation is a mainstay in the treatment of symptomatic patients or those with ischaemia-producing coronary lesions, and reduces ischaemia to a greater extent than medical treatment. Documentation of ischaemia and plaque burden is fundamental in the risk stratification of patients with stable coronary artery disease, and several invasive and non-invasive techniques are available (eg, fractional flow reserve or intravascular ultrasound) or being validated (eg, instantaneous wave-free ratio and optical coherence tomography). The use of new-generation drug-eluting stents and arterial conduits greatly improve clinical outcome in patients undergoing percutaneous coronary intervention (PCI) or coronary artery bypass grafting (CABG). PCI is feasible, safe, and effective in many patients with stable coronary artery disease who remain symptomatic despite medical treatment. In patients with multivessel and left main coronary artery disease, the decision between PCI or CABG is guided by the local Heart Team (team of different cardiovascular specialists, including non-invasive and invasive cardiologists, and cardiac surgeons), who carefully judge the possible benefits and risks inherent to PCI and CABG. In specific subsets, such as patients with diabetes and advanced, multivessel coronary artery disease, CABG remains the standard of care in view of improved protection against recurrent ischaemic adverse events.
Resumo:
BACKGROUND A single non-invasive gene expression profiling (GEP) test (AlloMap®) is often used to discriminate if a heart transplant recipient is at a low risk of acute cellular rejection at time of testing. In a randomized trial, use of the test (a GEP score from 0-40) has been shown to be non-inferior to a routine endomyocardial biopsy for surveillance after heart transplantation in selected low-risk patients with respect to clinical outcomes. Recently, it was suggested that the within-patient variability of consecutive GEP scores may be used to independently predict future clinical events; however, future studies were recommended. Here we performed an analysis of an independent patient population to determine the prognostic utility of within-patient variability of GEP scores in predicting future clinical events. METHODS We defined the GEP score variability as the standard deviation of four GEP scores collected ≥315 days post-transplantation. Of the 737 patients from the Cardiac Allograft Rejection Gene Expression Observational (CARGO) II trial, 36 were assigned to the composite event group (death, re-transplantation or graft failure ≥315 days post-transplantation and within 3 years of the final GEP test) and 55 were assigned to the control group (non-event patients). In this case-controlled study, the performance of GEP score variability to predict future events was evaluated by the area under the receiver operator characteristics curve (AUC ROC). The negative predictive values (NPV) and positive predictive values (PPV) including 95 % confidence intervals (CI) of GEP score variability were calculated. RESULTS The estimated prevalence of events was 17 %. Events occurred at a median of 391 (inter-quartile range 376) days after the final GEP test. The GEP variability AUC ROC for the prediction of a composite event was 0.72 (95 % CI 0.6-0.8). The NPV for GEP score variability of 0.6 was 97 % (95 % CI 91.4-100.0); the PPV for GEP score variability of 1.5 was 35.4 % (95 % CI 13.5-75.8). CONCLUSION In heart transplant recipients, a GEP score variability may be used to predict the probability that a composite event will occur within 3 years after the last GEP score. TRIAL REGISTRATION Clinicaltrials.gov identifier NCT00761787.
Resumo:
AIMS A non-invasive gene-expression profiling (GEP) test for rejection surveillance of heart transplant recipients originated in the USA. A European-based study, Cardiac Allograft Rejection Gene Expression Observational II Study (CARGO II), was conducted to further clinically validate the GEP test performance. METHODS AND RESULTS Blood samples for GEP testing (AlloMap(®), CareDx, Brisbane, CA, USA) were collected during post-transplant surveillance. The reference standard for rejection status was based on histopathology grading of tissue from endomyocardial biopsy. The area under the receiver operating characteristic curve (AUC-ROC), negative (NPVs), and positive predictive values (PPVs) for the GEP scores (range 0-39) were computed. Considering the GEP score of 34 as a cut-off (>6 months post-transplantation), 95.5% (381/399) of GEP tests were true negatives, 4.5% (18/399) were false negatives, 10.2% (6/59) were true positives, and 89.8% (53/59) were false positives. Based on 938 paired biopsies, the GEP test score AUC-ROC for distinguishing ≥3A rejection was 0.70 and 0.69 for ≥2-6 and >6 months post-transplantation, respectively. Depending on the chosen threshold score, the NPV and PPV range from 98.1 to 100% and 2.0 to 4.7%, respectively. CONCLUSION For ≥2-6 and >6 months post-transplantation, CARGO II GEP score performance (AUC-ROC = 0.70 and 0.69) is similar to the CARGO study results (AUC-ROC = 0.71 and 0.67). The low prevalence of ACR contributes to the high NPV and limited PPV of GEP testing. The choice of threshold score for practical use of GEP testing should consider overall clinical assessment of the patient's baseline risk for rejection.
Resumo:
BACKGROUND The diagnostic performance of biochemical scores and artificial neural network models for portal hypertension and cirrhosis is not well established. AIMS To assess diagnostic accuracy of six serum scores, artificial neural networks and liver stiffness measured by transient elastography, for diagnosing cirrhosis, clinically significant portal hypertension and oesophageal varices. METHODS 202 consecutive compensated patients requiring liver biopsy and hepatic venous pressure gradient measurement were included. Several serum tests (alone and combined into scores) and liver stiffness were measured. Artificial neural networks containing or not liver stiffness as input variable were also created. RESULTS The best non-invasive method for diagnosing cirrhosis, portal hypertension and oesophageal varices was liver stiffness (C-statistics=0.93, 0.94, and 0.90, respectively). Among serum tests/scores the best for diagnosing cirrhosis and portal hypertension and oesophageal varices were, respectively, Fibrosis-4, and Lok score. Artificial neural networks including liver stiffness had high diagnostic performance for cirrhosis, portal hypertension and oesophageal varices (accuracy>80%), but were not statistically superior to liver stiffness alone. CONCLUSIONS Liver stiffness was the best non-invasive method to assess the presence of cirrhosis, portal hypertension and oesophageal varices. The use of artificial neural networks integrating different non-invasive tests did not increase the diagnostic accuracy of liver stiffness alone.
Resumo:
OBJECTIVE There is controversy regarding the significance of radiological consolidation in the context of COPD exacerbation (eCOPD). While some studies into eCOPD exclude these cases, consolidation is a common feature of eCOPD admissions in real practice. This study aims to address the question of whether consolidation in eCOPD is a distinct clinical phenotype with implications for management decisions and outcomes. PATIENTS AND METHODS The European COPD Audit was carried out in 384 hospitals from 13 European countries between 2010 and 2011 to analyze guideline adherence in eCOPD. In this analysis, admissions were split according to the presence or not of consolidation on the admission chest radiograph. Groups were compared in terms of clinical and epidemiological features, existing treatment, clinical care utilized and mortality. RESULTS 14,111 cases were included comprising 2,714 (19.2%) with consolidation and 11,397 (80.8%) without. The risk of radiographic consolidation increased with age, female gender, cardiovascular diseases, having had two or more admissions in the previous year, and sputum color change. Previous treatment with inhaled steroids was not associated. Patients with radiographic consolidation were significantly more likely to receive antibiotics, oxygen and non-invasive ventilation during the admission and had a lower survival from admission to 90-day follow-up. CONCLUSIONS Patients admitted for COPD exacerbation who have radiological consolidation have a more severe illness course, are treated more intensively by clinicians and have a poorer prognosis. We recommend that these patients be considered a distinct subset in COPD exacerbation.
Resumo:
UNLABELLED Evidence for target values of arterial oxygen saturation (SaO2), CO2, and pH has changed substantially over the last 20 years. A representative survey concerning treatment strategies in extremely low-birth-weight infants (ELBW) was sent to all German neonatal intensive care units (NICUs) treating ELBW infants in 1997. A follow-up survey was conducted in 2011 and sent to all NICUs in Germany, Austria, and Switzerland. During the observation period, NICUs targeting SaO2 of 80, 85, and 90 % have increased, while units aiming for 94 and 96 % decreased (all p < 0.001). Similarly, NICUs aiming for pH 7.25 or lower increased, while 7.35 or higher decreased (both p < 0.001). Furthermore, more units targeted a CO2 of 50 mmHg (7.3 kPa) or higher (p < 0.001), while fewer targeted 40 or 35 mmHg (p < 0.001). Non-invasive ventilation (NIV) was used in 80.2 % of NICUs in 2011. The most frequently used ventilation modes were synchronized intermittent mandatory ventilation (SIMV) (67.5 %) and intermittent positive pressure ventilation (IPPV) (59.7 %) in 1997 and SIMV (77.2 %) and synchronized intermittent positive pressure ventilation (SIPPV) (26.8 %) in 2011. NICUs reporting frequent or always use of IPPV decreased to 11.0 % (p < 0.001). SIMV (77.2 %) and SIPPV (26.8 %) did not change from 1997 to 2011, while high-frequency oscillation (HFO) increased from 9.1 to 19.7 % (p = 0.018). Differences between countries, level of care, and size of the NICU were minimal. CONCLUSIONS Target values for SaO2 decreased, while CO2 and pH increased significantly during the observation period. Current values largely reflect available evidence at time of the surveys. WHAT IS KNOWN • Evidence concerning target values of oxygen saturation, CO 2 , and pH in extremely low-birth-weight infants has grown substantially. • It is not known to which extent this knowledge is transferred into clinical practice and if treatment strategies have changed. WHAT IS NEW • Target values for oxygen saturation in ELBW infants decreased between 1997 and 2011 while target values for CO 2 and pH increased. • Similar treatment strategies existed in different countries, hospitals of different size, or university versus nonuniversity hospitals in 2011.