932 resultados para Modified Delphi method
Resumo:
Amperometry at a carbon fiber microelectrode modified with a composite of ruthenium oxide and cyanoruthenate was used to monitor chemical secretions of single pancreatic beta cells from rats and humans. When the insulin secretagogues glucose, tolbutamide, and K+ were applied to the cell, a series of randomly occurring current spikes was observed. The current spikes were shown to be due to the detection of chemical substances secreted from the cell. Chromatography showed that the primary secreted substance detected by the electrode was insulin. The current spikes were strongly dependent on external Ca2+, had an average area that was independent of the stimulation method, and had an area distribution which corresponded to the distribution of vesicle sizes in beta cells. It was concluded that the spikes were due to the detection of concentration pulses of insulin secreted by exocytosis.
Resumo:
We have examined whether the secretion of erythropoietin (Epo) from genetically modified cells could represent an alternative to repeated injections of the recombinant hormone for treating chronic anemias responsive to Epo. Primary mouse skin fibroblasts were transduced with a retroviral vector in which the murine Epo cDNA is expressed under the control of the murine phosphoglycerate kinase promoter. "Neo-organs" containing the genetically modified fibroblasts embedded into collagen lattices were implanted into the peritoneal cavity of mice. Increased hematocrit (> 80%) and elevated serum Epo concentration (ranging from 60 to 408 milliunits/ml) were observed in recipient animals over a 10-month observation period. Hematocrit values measured in recipient mice varied according to the number of implanted Epo-secreting fibroblasts (ranging from 2.5 to 20 x 10(6)). The implantation of neo-organs containing Epo-secreting fibroblasts appeared, therefore, as a convenient method to achieve permanent in vivo delivery of the hormone. We estimated that the biological efficacy of the approach may be relevant for the treatment of human hemoglobinopathies.
Resumo:
Array measurements have become a valuable tool for site response characterization in a non-invasive way. The array design, i.e. size, geometry and number of stations, has a great influence in the quality of the obtained results. From the previous parameters, the number of available stations uses to be the main limitation for the field experiments, because of the economical and logistical constraints that it involves. Sometimes, from the initially planned array layout, carefully designed before the fieldwork campaign, one or more stations do not work properly, modifying the prearranged geometry. Whereas other times, there is not possible to set up the desired array layout, because of the lack of stations. Therefore, for a planned array layout, the number of operative stations and their arrangement in the array become a crucial point in the acquisition stage and subsequently in the dispersion curve estimation. In this paper we carry out an experimental work to analyze which is the minimum number of stations that would provide reliable dispersion curves for three prearranged array configurations (triangular, circular with central station and polygonal geometries). For the optimization study, we analyze together the theoretical array responses and the experimental dispersion curves obtained through the f-k method. In the case of the f-k method, we compare the dispersion curves obtained for the original or prearranged arrays with the ones obtained for the modified arrays, i.e. the dispersion curves obtained when a certain number of stations n is removed, each time, from the original layout of X geophones. The comparison is evaluated by means of a misfit function, which helps us to determine how constrained are the studied geometries by stations removing and which station or combination of stations affect more to the array capability when they are not available. All this information might be crucial to improve future array designs, determining when it is possible to optimize the number of arranged stations without losing the reliability of the obtained results.
Resumo:
In this work, a modified version of the elastic bunch graph matching (EBGM) algorithm for face recognition is introduced. First, faces are detected by using a fuzzy skin detector based on the RGB color space. Then, the fiducial points for the facial graph are extracted automatically by adjusting a grid of points to the result of an edge detector. After that, the position of the nodes, their relation with their neighbors and their Gabor jets are calculated in order to obtain the feature vector defining each face. A self-organizing map (SOM) framework is shown afterwards. Thus, the calculation of the winning neuron and the recognition process are performed by using a similarity function that takes into account both the geometric and texture information of the facial graph. The set of experiments carried out for our SOM-EBGM method shows the accuracy of our proposal when compared with other state-of the-art methods.
Resumo:
The Gini index is the most common method for estimating the level of income inequality in countries. In this paper we suggest a simple modification that takes into account the moderating effect of in-kind government benefits. Unlike other studies that use micro level data that is rarely available for many countries or over a period of time, the proposed modified Gini index could be calculated using just the regularly available data for each country. Such data includes the original Gini coefficient, government consumption expenditures, GDP and total tax revenue as a percentage of GDP. This modified version of the Gini index allows us to calculate the level of inequality more precisely, and make better comparisons between countries and over time.
Resumo:
Thesis (Master's)--University of Washington, 2016-06
Resumo:
In this article we study the effects of adsorbed phase compression, lattice structure, and pore size distribution on the analysis of adsorption in microporous activated carbon. The lattice gas approach of Ono-Kondo is modified to account for the above effects. Data of nitrogen adsorption at 77 K onto a number of activated carbon samples are analyzed to investigate the pore filling pressure versus pore width, the packing effect, and the compression of the adsorbed phase. It is found that the PSDs obtained from this analysis are comparable to those obtained by the DFT method. The discrete nature of the PSDs derived from the modified lattice gas theory is due to the inherent assumption of discrete layers of molecules. Nevertheless, it does provide interesting information on the evolution of micropores during the activation process.
Resumo:
In the English literature, facial approximation methods have been commonly classified into three types: Russian, American, or Combination. These categorizations are based on the protocols used, for example, whether methods use average soft-tissue depths (American methods) or require face muscle construction (Russian methods). However, literature searches outside the usual realm of English publications reveal key papers that demonstrate that the Russian category above has been founded on distorted views. In reality, Russian methods are based on limited face muscle construction, with heavy reliance on modified average soft-tissue depths. A closer inspection of the American method also reveals inconsistencies with the recognized classification scheme. This investigation thus demonstrates that all major methods of facial approximation depend on both face anatomy and average soft-tissue depths, rendering common method classification schemes redundant. The best way forward appears to be for practitioners to describe the methods they use (including the weight each one gives to average soft-tissue depths and deep face tissue construction) without placing them in any categorical classificatory group or giving them an ambiguous name. The state of this situation may need to be reviewed in the future in light of new research results and paradigms.
Resumo:
Most magnetic resonance imaging (MRI) spatial encoding techniques employ low-frequency pulsed magnetic field gradients that undesirably induce multiexponentially decaying eddy currents in nearby conducting structures of the MRI system. The eddy currents degrade the switching performance of the gradient system, distort the MRI image, and introduce thermal loads in the cryostat vessel and superconducting MRI components. Heating of superconducting magnets due to induced eddy currents is particularly problematic as it offsets the superconducting operating point, which can cause a system quench. A numerical characterization of transient eddy current effects is vital for their compensation/control and further advancement of the MRI technology as a whole. However, transient eddy current calculations are particularly computationally intensive. In large-scale problems, such as gradient switching in MRI, conventional finite-element method (FEM)-based routines impose very large computational loads during generation/solving of the system equations. Therefore, other computational alternatives need to be explored. This paper outlines a three-dimensional finite-difference time-domain (FDTD) method in cylindrical coordinates for the modeling of low-frequency transient eddy currents in MRI, as an extension to the recently proposed time-harmonic scheme. The weakly coupled Maxwell's equations are adapted to the low-frequency regime by downscaling the speed of light constant, which permits the use of larger FDTD time steps while maintaining the validity of the Courant-Friedrich-Levy stability condition. The principal hypothesis of this work is that the modified FDTD routine can be employed to analyze pulsed-gradient-induced, transient eddy currents in superconducting MRI system models. The hypothesis is supported through a verification of the numerical scheme on a canonical problem and by analyzing undesired temporal eddy current effects such as the B-0-shift caused by actively shielded symmetric/asymmetric transverse x-gradient head and unshielded z-gradient whole-body coils operating in proximity to a superconducting MRI magnet.
Resumo:
A modified UNIQUAC model has been extended to describe and predict the equilibrium relative humidity and moisture content for wood. The method is validated over a range of moisture content from oven-dried state to fiber saturation point, and over a temperature range of 20-70 degrees C. Adjustable parameters and binary interaction parameters of the UNIQUAC model were estimated from experimental data for Caribbean pine and Hoop pine as well as data available in the literature. The two group-interaction parameters for the wood-moisture system were consistent with using function group contributions for H2O, -OH and -CHO. The result reconfirms that the main contributors to water adsorption in cell walls are the hydroxyl groups of the carbohydrates in cellulose and hemicelluloses. This provides some physical insight into the intermolecular force and energy between bound water and the wood material. (c) 2006 Elsevier Ltd. All rights reserved.
Resumo:
This paper presents the implementation of a modified particle filter for vision-based simultaneous localization and mapping of an autonomous robot in a structured indoor environment. Through this method, artificial landmarks such as multi-coloured cylinders can be tracked with a camera mounted on the robot, and the position of the robot can be estimated at the same time. Experimental results in simulation and in real environments show that this approach has advantages over the extended Kalman filter with ambiguous data association and various levels of odometric noise.
Resumo:
AIMS To demonstrate the potential use of in vitro poly(lactic-co-glycolic acid) (PLGA) microparticles in comparison with triamcinolone suspension to aid visualisation of vitreous during anterior and posterior vitrectomy. METHODS PLGA microparticles (diameter 10-60 microm) were fabricated using single and/or double emulsion technique(s) and used untreated or following the surface adsorption of a protein (transglutaminase). Particle size, shape, morphology and surface topography were assessed using scanning electron microscopy (SEM) and compared with a standard triamcinolone suspension. The efficacy of these microparticles to enhance visualisation of vitreous against the triamcinolone suspension was assessed using an in vitro set-up exploiting porcine vitreous. RESULTS Unmodified PLGA microparticles failed to adequately adhere to porcine vitreous and were readily washed out by irrigation. In contrast, modified transglutaminase-coated PLGA microparticles demonstrated a significant improvement in adhesiveness and were comparable to a triamcinolone suspension in their ability to enhance the visualisation of vitreous. This adhesive behaviour also demonstrated selectivity by not binding to the corneal endothelium. CONCLUSION The use of transglutaminase-modified biodegradable PLGA microparticles represents a novel method of visualising vitreous and aiding vitrectomy. This method may provide a distinct alternative for the visualisation of vitreous whilst eliminating the pharmacological effects of triamcinolone acetonide suspension.
Resumo:
Having a fixed differential-group delay (DGD) term b′ in the coarse-step method results in a repetitive pattern in the autocorrelation function (ACF). We solve this problem by inserting a varying DGD term at each integration step. Furthermore we compute the range of values needed for b′ and simulate the phenomenon of polarisation mode dispersion for different statistical distributions of b′. We examine systematically the modified coarse-step method compared to the analytical model, through our simulation results. © 2006 Elsevier B.V. All rights reserved.
Resumo:
Objectives To identify criteria by which patients can assess the communication skills of pharmacy students. Method Potential assessment criteria were generated from 2 main sources: a literature review and a focus group discussion. A modified two-round Delphi survey was subsequently conducted with 35 professionals who were actively involved in teaching and assessing communication skills of pharmacy students to determine the importance and reliability of each criterion. Results Consensus ratings identified 7 criteria that were important measures of pharmacy students' communication skills and could be reliably assessed by patients. Conclusions A modified two-round Delphi consultation survey successfully identified criteria that can be used by patients to assess the communication skills of pharmacy undergraduates. Future work will examine the feasibility of using patients as assessors of communication skills of pharmacy students, preregistration pharmacists, and qualified pharmacists.
Resumo:
Numerical techniques have been finding increasing use in all aspects of fracture mechanics, and often provide the only means for analyzing fracture problems. The work presented here, is concerned with the application of the finite element method to cracked structures. The present work was directed towards the establishment of a comprehensive two-dimensional finite element, linear elastic, fracture analysis package. Significant progress has been made to this end, and features which can now be studied include multi-crack tip mixed-mode problems, involving partial crack closure. The crack tip core element was refined and special local crack tip elements were employed to reduce the element density in the neighbourhood of the core region. The work builds upon experience gained by previous research workers and, as part of the general development, the program was modified to incorporate the eight-node isoparametric quadrilateral element. Also. a more flexible solving routine was developed, and provided a very compact method of solving large sets of simultaneous equations, stored in a segmented form. To complement the finite element analysis programs, an automatic mesh generation program has been developed, which enables complex problems. involving fine element detail, to be investigated with a minimum of input data. The scheme has proven to be versati Ie and reasonably easy to implement. Numerous examples are given to demonstrate the accuracy and flexibility of the finite element technique.