929 resultados para Median Voter Hypothesis
Resumo:
BACKGROUND: Can the application of local anesthetics (Neural Therapy, NT) alone durably improve pain symptoms in referred patients with chronic and refractory pain? If the application of local anesthetics does lead to an improvement that far exceeds the duration of action of local anesthetics, we will postulate that a vicious circle of pain in the reflex arcs has been disrupted (hypothesis). METHODS: Case series design. We exclusively used procaine or lidocaine. The inclusion criteria were severe pain and chronic duration of more than three months, pain unresponsive to conventional medical measures, written referral from physicians or doctors of chiropractic explicitly to NT. Patients with improvement of pain who started on additional therapy during the study period for a reason other than pain were excluded in order to avoid a potential bias. Treatment success was measured after one year follow-up using the outcome measures of pain and analgesics intake. RESULTS: 280 chronic pain patients were included; the most common reason for referral was back pain. The average number of consultations per patient was 9.2 in the first year (median 8.0). After one year, in 60 patients pain was unchanged, 52 patients reported a slight improvement, 126 were considerably better, and 41 pain-free. At the same time, 74.1 % of the patients who took analgesics before starting NT needed less or no more analgesics at all. No adverse effects or complications were observed. CONCLUSIONS: The good long-term results of the targeted therapeutic local anesthesia (NT) in the most problematic group of chronic pain patients (unresponsive to all evidence based conventional treatment options) indicate that a vicious circle has been broken. The specific contribution of the intervention to these results cannot be determined. The low costs of local anesthetics, the small number of consultations needed, the reduced intake of analgesics, and the lack of adverse effects also suggest the practicality and cost-effectiveness of this kind of treatment. Controlled trials to evaluate the true effect of NT are needed.
Resumo:
Suppose that one observes independent random variables (X1, Y1), (X2, Y2), …, (Xn, Yn) in R2 with unknown distributions, except that Median(Yi | Xi = M(x) for some unknown isotonic function M. We describe an explicit algorithm for the computation of confidence bands for the median function M whose running time is of order O(n2). The bands rely on multiscale sign tests and are shown to have desirable asymptotic properties.
Resumo:
OBJECTIVE The purpose of this study was to examine the recurrence rate of wound rupture in primary pilonidal sinus disease (PSD) after median closure. SUBJECTS AND METHODS A total of 583 patients from the German military cohort were interviewed. We compared the choice of surgical therapy, wound dehiscence (if present) and long-term recurrence-free survival for patients with primary open treatment, marsupialization and primary median treatment (closed vs. secondary open, respectively). Actuarial recurrence rate was determined using the Kaplan-Meier calculation with a follow-up of up to 20 years after primary PSD surgery. RESULTS Patients with excision followed by primary open wound treatment showed a significantly lower 5- than 10-year recurrence rate (8.3 vs. 11.2%) compared to the patients with primary midline closure (17.4 vs. 20.5%, p = 0.03). The 20-year recurrence rate was 28% in primary open wound treatment versus 44% in primary midline closure without wound rupture. In contrast to these findings, long-term recurrence rates following secondary open wound treatment (12.2% at 5 years vs. 17.1% at 10 years) tended to be higher (although not significantly, p = 0.57) compared to primary open treatment (8.3% at 5 years vs. 11.2% at 10 years). There was no statistical difference in long-term recurrence rates between secondary open and primary midline closure (p = 0.7). Hence, despite only a short wound closure time experienced before wound rupture, the patient does not fully benefit from an open wound treatment in terms of recurrence rate. CONCLUSION The postoperative pilonidal sinus wound rupture of primary midline closures did not significantly increase the 5- and 10-year long-term recurrence rates compared to uneventfully healing primary midline closures.
Resumo:
PURPOSE To investigate the feasibility of MR diffusion tensor imaging (DTI) of the median nerve using simultaneous multi-slice echo planar imaging (EPI) with blipped CAIPIRINHA. MATERIALS AND METHODS After federal ethics board approval, MR imaging of the median nerves of eight healthy volunteers (mean age, 29.4 years; range, 25-32) was performed at 3 T using a 16-channel hand/wrist coil. An EPI sequence (b-value, 1,000 s/mm(2); 20 gradient directions) was acquired without acceleration as well as with twofold and threefold slice acceleration. Fractional anisotropy (FA), mean diffusivity (MD) and quality of nerve tractography (number of tracks, average track length, track homogeneity, anatomical accuracy) were compared between the acquisitions using multivariate ANOVA and the Kruskal-Wallis test. RESULTS Acquisition time was 6:08 min for standard DTI, 3:38 min for twofold and 2:31 min for threefold acceleration. No differences were found regarding FA (standard DTI: 0.620 ± 0.058; twofold acceleration: 0.642 ± 0.058; threefold acceleration: 0.644 ± 0.061; p ≥ 0.217) and MD (standard DTI: 1.076 ± 0.080 mm(2)/s; twofold acceleration: 1.016 ± 0.123 mm(2)/s; threefold acceleration: 0.979 ± 0.153 mm(2)/s; p ≥ 0.074). Twofold acceleration yielded similar tractography quality compared to standard DTI (p > 0.05). With threefold acceleration, however, average track length and track homogeneity decreased (p = 0.004-0.021). CONCLUSION Accelerated DTI of the median nerve is feasible. Twofold acceleration yields similar results to standard DTI. KEY POINTS • Standard DTI of the median nerve is limited by its long acquisition time. • Simultaneous multi-slice acquisition is a new technique for accelerated DTI. • Accelerated DTI of the median nerve yields similar results to standard DTI.
Resumo:
PURPOSE Replacement of the torn anterior cruciate ligament (ACL) with a transplant is today`s gold standard. A new technique for preserving and healing the torn ACL is presented. HYPOTHESIS a dynamic intraligamentary stabilization (DIS) that provides continuous postinjury stability of the knee and ACL in combination with biological improvement of the healing environment [leucocyte- and platelet-rich fibrin (L-PRF) and microfracturing] should enable biomechanically stable ACL self-healing. METHODS Ten sportive patients were treated by DIS employing an internal stabilizer to keep the unstable knee in a posterior translation, combined with microfracturing and platelet-rich fibrin induction at the rupture site to promote self-healing. Postoperative clinical [Tegner, Lysholm, International Knee Documentation Committee (IKDC), visual analogue scale patient satisfaction score] and radiological evaluation, as well as assessment of knee laxity was performed at 6 weeks, 3, 6, 12, and 24 months. RESULTS One patient had a re-rupture 5 months postoperative and was hence excluded from further follow-ups. The other nine patients presented the following outcomes at 24 months: median Lysholm score of 100; IKDC score of 98 (97-100); median Tegner score of 6 (range 9-5); anterior translation difference of 1.4 mm (-1 to 3 mm); median satisfaction score of 9.8 (9-10). MRI showed scarring and continuity of the ligament in all patients. CONCLUSIONS DIS combined with microfracturing and L-PRF resulted in stable clinical and radiological healing of the torn ACL in all but one patient of this first series. They attained normal knee scores, reported excellent satisfaction and could return to their previous levels of sporting activity. LEVEL OF EVIDENCE Case series with no comparison group, Level IV.
Resumo:
OBJECTIVE The aim of this study was first to assess whether first-trimester serum concentrations of placental growth factor (PlGF) differ between patients with and without gestational diabetes (GDM) and second to test whether there is a correlation between glycosylated hemoglobin (HbA1c), a factor recently shown to be useful in predicting GDM, and PlGF. METHODS PlGF was measured at 8-14 weeks with the Kryptor Immunoassay Analyzer (Brahms, Berlin, Germany). Absolute values were converted to multiples of the median using the software provided by the Fetal Medicine Foundation London. GDM was diagnosed using internationally accepted criteria. HbA1c levels were quantified using the TOSOH G7 automated hemoglobin analyzer. RESULTS From January to December 2014, 328 women were included in the study, 51 (15.5%) of whom developed GDM. First-trimester PlGF quantification does not discriminate between women at risk to develop GDM and controls, while HbA1c is able to do so. No correlation was found between PlGF and HbA1c. CONCLUSION Our findings do not lend support to the hypothesis that early PlGF values are different in women who later develop GDM.
Resumo:
OBJECTIVE To compare the precision of fit of long-span vs. short-span implant-supported screw-retained fixed dental prostheses (FDPs) made from computer-aided-design/computer-aided-manufactured (CAD/CAM) titanium and veneered with ceramic. The null hypothesis was that there is no difference in the vertical microgap between long-span and short-span FDPs. MATERIALS AND METHODS CAD/CAM titanium frameworks for an implant-supported maxillary FDP on implants with a flat platform were fabricated on one single master cast. Group A consisted of six 10-unit FDPs connected to six implants (FDI positions 15, 13, 11, 21, 23, 25) and group B of six 5-unit FDPs (three implants, FDI positions 21, 23, 25). The CAD/CAM system from Biodenta Swiss AG (Berneck, Switzerland) was used for digitizing (laser scanner) the master cast and anatomical CAD of each framework separately. The frameworks were milled (CAM) from a titanium grade V monobloc and veneered with porcelain. Median vertical distance between implant and FDP platforms from the non-tightened implants (one-screw test on implant 25) was calculated from mesial, buccal, and distal scanning electron microscope measurements. RESULTS All measurements showed values <40 μm. Total median vertical microgaps were 23 μm (range 2-38 μm) for group A and 7 μm (4-24 μm) for group B. The difference between the groups was statistically significant at implant 21 (P = 0.002; 97.5% CI -27.3 to -4.9) and insignificant at implant 23 (P = 0.093; -3.9 to 1.0). CONCLUSIONS CAD/CAM fabrication including laboratory scanning and porcelain firing was highly precise and reproducible for all long- and short-span FDPs. While all FDPs showed clinically acceptable values, the short-span FDPs were statistically more precise at the 5-unit span distance.
Resumo:
BACKGROUND Continuous venovenous hemodialysis (CVVHD) may generate microemboli that cross the pulmonary circulation and reach the brain. The aim of the present study was to quantify (load per time interval) and qualify (gaseous vs. solid) cerebral microemboli (CME), detected as high-intensity transient signals, using transcranial Doppler ultrasound. MATERIALS AND METHODS Twenty intensive care unit (ICU group) patients requiring CVVHD were examined. CME were recorded in both middle cerebral arteries for 30 minutes during CVVHD and a CVVHD-free interval. Twenty additional patients, hospitalized for orthopedic surgery, served as a non-ICU control group. Statistical analyses were performed using the Mann-Whitney U test or the Wilcoxon matched-pairs signed-rank test, followed by Bonferroni corrections for multiple comparisons. RESULTS In the non-ICU group, 48 (14.5-169.5) (median [range]) gaseous CME were detected. In the ICU group, the 67.5 (14.5-588.5) gaseous CME detected during the CVVHD-free interval increased 5-fold to 344.5 (59-1019) during CVVHD (P<0.001). The number of solid CME was low in all groups (non-ICU group: 2 [0-5.5]; ICU group CVVHD-free interval: 1.5 [0-14.25]; ICU group during CVVHD: 7 [3-27.75]). CONCLUSIONS This observational pilot study shows that CVVHD was associated with a higher gaseous but not solid CME burden in critically ill patients. Although the differentiation between gaseous and solid CME remains challenging, our finding may support the hypothesis of microbubble generation in the CVVHD circuit and its transpulmonary translocation toward the intracranial circulation. Importantly, the impact of gaseous and solid CME generated during CVVHD on brain integrity of critically ill patients currently remains unknown and is highly debated.
Resumo:
Surveys on voting behavior typically overestimate turnout rates substantially. To disentangle different sources of bias - coverage error, nonresponse bias, and overreporting - we conducted a validation study in which respondents' self-reported voting behavior was compared to administrative voting records (N = 2000). Our results show that all three sources of error inflate the survey estimate of the turnout rate and also bias estimates from political participation models, although coverage error is only moderate compared to the more pronounced biases due to nonresponse and overreporting. Furthermore, results from a wording experiment do not provide evidence that revised wording reduces measurement bias.
Resumo:
The goal of this study was to test the hypothesis that the aggregated state of natural marine particles constrains the sensitivity of optical beam attenuation to particle size. An instrumented bottom tripod was deployed at the 12-m node of the Martha's Vineyard Coastal Observatory to monitor particle size distributions, particle size-versus-settling-velocity relationships, and the beam attenuation coefficient (c(p)) in the bottom boundary layer in September 2007. An automated in situ filtration system on the tripod collected 24 direct estimates of suspended particulate mass (SPM) during each of five deployments. On a sampling interval of 5 min, data from a Sequoia Scientific LISST 100x Type B were merged with data from a digital floc camera to generate suspended particle volume size distributions spanning diameters from approximately 2 mu m to 4 cm. Diameter-dependent densities were calculated from size-versus-settling-velocity data, allowing conversion of the volume size distributions to mass distributions, which were used to estimate SPM every 5 min. Estimated SPM and measured c(p) from the LISST 100x were linearly correlated throughout the experiment, despite wide variations in particle size. The slope of the line, which is the ratio of c(p) to SPM, was 0.22 g m(-2). Individual estimates of c(p):SPM were between 0.2 and 0.4 g m(-2) for volumetric median particle diameters ranging from 10 to 150 mu m. The wide range of values in c(p):SPM in the literature likely results from three factors capable of producing factor-of-two variability in the ratio: particle size, particle composition, and the finite acceptance angle of commercial beam-transmissometers.
Did Impending War in Europe Help Destroy the Gold Bloc in 1936? An Internal Inconsistency Hypothesis
Resumo:
This paper investigates the gold bloc operated between France, the Netherlands, Switzerland and Belgium, especially over the period after the USA left the gold standard in March 1933 to its end in September 1936. It enquires into the effect of military-political developments in Germany and Italy on the sustainability of the gold bloc between its members. Juxtaposed is the view of leading political scientists, such as Henry Kissinger, who see impending war in Europe as deeply and adversely affecting psychology in Europe, and what may be called the standard "economists' view" that sees the demise of the gold bloc as being caused almost exclusively by economic factors. Developing concepts of external and internal inconsistency of the gold bloc, this investigation concludes that both economic and military-political developments played important roles in destroying the last vestiges of the gold standard.