979 resultados para MICRO-COMPUTED TOMOGRAPHY


Relevância:

80.00% 80.00%

Publicador:

Resumo:

INTRODUCTION: The Shwachman-Kulczycki score was the first scoring system used in cystic fibrosis to assess disease severity. Despite its subjectivity, it is still widely used. OBJECTIVE: To study correlations among forced expiratory volume in one second (FEV1), chest radiography, chest computed tomography, 6-minute walk test, and Shwachman-Kulczycki score in patients with cystic fibrosis and to test whether the Shwachman-Kulczycki score is still useful in monitoring the severity of the disease. METHODS: A cross-sectional prospective study was performed to analyze the correlations (Spearman). Patients with clinically stable cystic fibrosis, aged 3-21 years, were included. RESULTS: 43 patients, 19F/24M, mean age 10.5 + 4.7 years, with a median Shwachman-Kulczycki score of 70 were studied. The median Brasfield and Bhalla scores were 17 and 10, respectively. The mean Z score for the 6-minute walk test was -1.1 + 1.106 and the mean FEV1 was 59 + 26 (as percentage of predicted values). The following significant correlations versus the Shwachman-Kulczycki score were found: FEV1 (r = 0.76), 6-minute walk test (r = 0.71), chest radiography (r = 0.71) and chest computed tomography (r = -0.78). When patients were divided according to FEV1, a statistically significantly correlation with the Shwachman-Kulczycki score was found only in patients with FEV1 <70% (r = 0.67). CONCLUSIONS: The Shwachman-Kulczycki score remains an useful tool for monitoring the severity of cystic fibrosis, adequately reflecting the functional impairment and chest radiography and tomography changes, especially in patients with greater impairment of lung function. When assessing patients with mild lung disease its limitations should be considered and its usefulness in such patients should be evaluated in larger populations.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

FUNDAMENTO: Apesar de algumas evidências sugerirem associação entre a exposição de uma tecnologia na literatura científica e sua difusão na prática clínica, poucos estudos avaliaram essa associação. OBJETIVO: O objetivo deste estudo é analisar se o padrão de publicação científica sobre duas tecnologias competitivas utilizadas na avaliação da doença arterial coronária (DAC) reflete o que ocorre na prática clínica. MÉTODOS: Avaliou-se o número de artigos científicos publicados anualmente na literatura médica (interesse científico global na tecnologia) sobre duas tecnologias utilizadas na avaliação da doença arterial coronária: tomografia computadorizada por feixe de elétrons e tomografia computadorizada com múltiplos detectores. Foi também analisado o número de países que publicam anualmente artigos científicos sobre essas tecnologias (interesse geográfico na tecnologia). RESULTADOS: A tomografia computadorizada por feixe de elétrons (electron beam computed tomography - EBCT) apresentou ápice de "interesse científico global" em 2001, com 127 artigos publicados. Após esse ápice, o "interesse científico global" diminuiu cerca de 50% em 2008. Em oposição, o "interesse científico global" pela tomografia computadorizada com múltiplos detectores (multidetector computed tomography - MDCT) aumentou progressivamente até 2007, com 454 artigos publicados nesse ano. O "interesse científico geográfico" pela EBCT teve ápice em 2002, com 14 países publicando sobre essa tecnologia. Após esse ápice, "o interesse científico geográfico" declinou em quase 25% até 2008, com 11 países publicando artigos sobre essa tecnologia. Em oposição, o "interesse científico geográfico" pela MDCT aumentou progressivamente até 2008, com 37 países publicando artigos sobre ela. CONCLUSÃO: A literatura científica médica é compatível com a substituição da EBCT pela MDCT na avaliação da DAC.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Background: Treatment of multinodular goiters (MNGs) is highly controversial. Radioiodine (RAI) therapy is a nonsurgical alternative for the elderly who decline surgery. Recently, recombinant human thyrotropin (rhTSH) has been used to augment RAI uptake and distribution. In this study, we determined the outcome of 30 mCi RAI preceded by rhTSH (0.1 mg) in euthyroid (EU) and hyperthyroid (subclinical/clinical) patients with large MNGs. Methods: This was a prospective cohort study. Forty-two patients (age, 43-80 years) with MNGs were treated with 30 mCi RAI after stimulation with 0.1 mg of rhTSH. Patients were divided into three groups, according to thyroid function: EU (n = 18), subclinically hyperthyroid (SC-H, n = 18), and clinically hyperthyroid (C-H, n = 6). All patients underwent a 90-day low-iodine diet before treatment, and those with clinical hyperthyroidism received methimazole 10 mg daily for 30 days. Serum TSH, free thyroxine (FT4), total triiodothyronine (TT3), and thyroglobulin were measured at baseline and at 24, 48, 72, 168 hours, and 1, 3, 6, 9, 12, 18, 24, and 36 months after therapy. Thyroid volume was assessed by computed tomography at baseline and every 6 months. Results: Patients had high iodine urinary excretion (308 +/- 108 mu g I/L) at baseline. TSH levels at baseline were within the normal range (1.5 +/- 0.7 mu U/mL) in the EU group and suppressed (< 0.3 mu U/mL) in the SC-H and C-H groups. After rhTSH, serum TSH peaked at 24 hours reaching 12.4 +/- 5.85 mu U/mL. After RAI administration, patients in both hyperthyroid groups had a higher increase in FT4 and TT3 compared with those in the EU group (p < 0.001). Thyroglobulin levels increased equally in all three groups until day 7. Thyroid volume decreased significantly in all patients. Side effects were more common in the SC-H and C-H groups (31.4% and 60.4%, respectively) compared with EU patients (17.8%). Permanent hypothyroidism was more prevalent in the EU group (50%) compared with the SC-H (11%) and C-H (16.6%) groups. Conclusions: Patients with MNG may have subclinical and clinical nonautoimmune iodine-induced hyperthyroidism. Despite a low-iodine diet and therapy with methimazole, hyperthyroid patients have a significantly higher increase in FT4 and TT3 levels after RAI ablation. This can lead to important side effects related mostly to the cardiac system. We strongly advise that patients with SC-H and C-H be adequately treated with methimazole and low-iodine diet aiming to normalize their hyperthyroid condition before rhTSH-stimulated treatment with RAI.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Objective: To assess the frequency of the genetic markers HLA-DRB1 and DQB1 in patients with Graves' orbitopathy ( GO) with and without extraocular muscle involvement. Design: The frequencies of class II HLA-DRB1 and DQB1 allele groups were determined for 81 Brazilian patients with GO and 161 normal subjects. The patients were divided into myogenic and nonmyogenic groups based on the clinical characteristics of the orbitopathy and quantitative computed tomography analysis of the extraocular muscle ( EOM) dimensions. Main outcome: Compared to the frequency obtained for samples of normal subjects of the Brazilian population, HLA-DRB1*16 (p(c)= 0.008) was overrepresented in myogenic and HLA-DRB1*03 (p(c)= 0.02) in nonmyogenic patients. Conclusions: The association between the HLA-DRB1* 16 and the myogenic subtype of GO suggests that EOM involvement in GO may be genetically predisposed.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Evidence demonstrates that sympathetic nervous system (SNS) activation causes osteopenia via beta(2)-adrenoceptor (beta(2)-AR) signaling. Here we show that female mice with chronic sympathetic hyperactivity owing to double knockout of adrenoceptors that negatively regulate norepinephrine release, alpha(2A)-AR and alpha(2C)-AR(alpha(2A)/alpha(2C)-ARKO), present an unexpected and generalized phenotype of high bone mass with decreased bone resorption and increased formation. In alpha(2A)/alpha(2C)-ARKO versus wild-type (WT) mice, micro-computed tomographic (mu CT) analysis showed increased, better connected, and more plate-shaped trabeculae in the femur and vertebra and increased cortical thickness in the vertebra, whereas biomechanical analysis showed increased tibial and femoral strength. Tibial mRNA expression of tartrate-resistant acid phosphatase (TRACP) and receptor activator of NF-kappa B (RANK), which are osteoclast-related factors, was lower in knockout (KO) mice. Plasma leptin and brain mRNA levels of cocaine amphetamine-regulated transcript (CART), which are factors that centrally affect bone turnover, and serum levels of estradiol were similar between mice strains. Tibial beta(2)-AR mRNA expression also was similar in KO and WT littermates, whereas alpha(2A)-, alpha(2B)- and alpha(2C)-AR mRNAs were detected in the tibia of WT mice and in osteoblast-like MC3T3-E1 cells. By immunohistochemistry, we detected alpha(2A)-, alpha(2B)-, alpha(2C)- and beta(2)-ARs in osteoblasts, osteoclasts, and chondrocytes of 18.5-day-old mouse fetuses and 35-day-old mice. Finally, we showed that isolated osteoclasts in culture are responsive to the selective alpha(2)-AR agonist clonidine and to the nonspecific alpha-AR antagonist phentolamine. These findings suggest that beta(2)-AR is not the single adrenoceptor involved in bone turnover regulation and show that alpha(2)-AR signaling also may mediate the SNS actions in the skeleton. (c) 2011 American Society for Bone and Mineral Research.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

This work discusses the determination of the breathing patterns in time sequence of images obtained from magnetic resonance (MR) and their use in the temporal registration of coronal and sagittal images. The registration is made without the use of any triggering information and any special gas to enhance the contrast. The temporal sequences of images are acquired in free breathing. The real movement of the lung has never been seen directly, as it is totally dependent on its surrounding muscles and collapses without them. The visualization of the lung in motion is an actual topic of research in medicine. The lung movement is not periodic and it is susceptible to variations in the degree of respiration. Compared to computerized tomography (CT), MR imaging involves longer acquisition times and it is preferable because it does not involve radiation. As coronal and sagittal sequences of images are orthogonal to each other, their intersection corresponds to a segment in the three-dimensional space. The registration is based on the analysis of this intersection segment. A time sequence of this intersection segment can be stacked, defining a two-dimension spatio-temporal (2DST) image. The algorithm proposed in this work can detect asynchronous movements of the internal lung structures and lung surrounding organs. It is assumed that the diaphragmatic movement is the principal movement and all the lung structures move almost synchronously. The synchronization is performed through a pattern named respiratory function. This pattern is obtained by processing a 2DST image. An interval Hough transform algorithm searches for synchronized movements with the respiratory function. A greedy active contour algorithm adjusts small discrepancies originated by asynchronous movements in the respiratory patterns. The output is a set of respiratory patterns. Finally, the composition of coronal and sagittal image pairs that are in the same breathing phase is realized by comparing of respiratory patterns originated from diaphragmatic and upper boundary surfaces. When available, the respiratory patterns associated to lung internal structures are also used. The results of the proposed method are compared with the pixel-by-pixel comparison method. The proposed method increases the number of registered pairs representing composed images and allows an easy check of the breathing phase. (C) 2010 Elsevier Ltd. All rights reserved.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Background: The presence of the periodontal ligament (PDL) makes it possible to absorb and distribute loads produced during masticatory function and other tooth contacts into the alveolar process via the alveolar bone proper. However, several factors affect the integrity of periodontal structures causing the destruction of the connective matrix and cells, the loss of fibrous attachment, and the resorption of alveolar bone. Methods: The purpose of this study was to evaluate the stress distribution by finite element analysis in a PDL in three-dimensional models of the upper central incisor under three different load conditions: 100 N occlusal loading at 45 degrees (model 1: masticatory load); 500 N at the incisal edge at 45 degrees (model 2: parafunctional habit); and 800 N at the buccal surface at 90 degrees (model 3: trauma case). The models were built from computed tomography scans. Results: The stress distribution was quite different among the models. The most significant values (harmful) of tensile and compressive stresses were observed in models 2 and 3, with similarly distinct patterns of stress distributions along the PDL. Tensile stresses were observed along the internal and external aspects of the PDL, mostly at the cervical and middle thirds. Conclusions: The stress generation in these models may affect the integrity of periodontal structures. A better understanding of the biomechanical behavior of the PDL under physiologic and traumatic loading conditions might enhance the understanding of the biologic reaction of the PDL in health and disease. J Periodontol 2009;80:1859-1867.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Bulk density of undisturbed soil samples can be measured using computed tomography (CT) techniques with a spatial resolution of about 1 mm. However, this technique may not be readily accessible. On the other hand, x-ray radiographs have only been considered as qualitative images to describe morphological features. A calibration procedure was set up to generate two-dimensional, high-resolution bulk density images from x-ray radiographs made with a conventional x-ray diffraction apparatus. Test bricks were made to assess the accuracy of the method. Slices of impregnated soil samples were made using hardsetting seedbeds that had been gamma scanned at 5-mm depth increments in a previous study. The calibration procedure involved three stages: (i) calibration of the image grey levels in terms of glass thickness using a staircase made from glass cover slips, (ii) measurement of ratio between the soil and resin mass attenuation coefficients and the glass mass attenuation coefficient, using compacted bricks of known thickness and bulk density, and (iii) image correction accounting for the heterogeneity of the irradiation field. The procedure was simple, rapid, and the equipment was easily accessible. The accuracy of the bulk density determination was good (mean relative error 0.015), The bulk density images showed a good spatial resolution, so that many structural details could be observed. The depth functions were consistent with both the global shrinkage and the gamma probe data previously obtained. The suggested method would be easily applied to the new fuzzy set approach of soil structure, which requires generation of bulk density images. Also, it would be an invaluable tool for studies requiring high-resolution bulk density measurement, such as studies on soil surface crusts.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

OBJECTIVES: To simplify the practice of stereotactic surgery by using an original method, apparatus, and solid anatomic replica for trajectory planning and to validate the method and apparatus in a laboratory and clinical trial. METHODS: The patient is marked with fiducials and scanned by using computed tomography or magnetic resonance imaging. The three-dimensional data are converted to a format acceptable to stereolithography. Stereolithography uses a laser to polymerize photosensitive resin into a solid plastic model (biomodel). Stereolithography can replicate brood vessels, soft tissue, tumor, and bone accurately (

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Magnetic resonance imaging (MRI) relies on the physical properties of unpaired protons in tissues to generate images. Unpaired protons behave like tiny bar magnets and will align themselves in a magnetic field. Radiofrequency pulses will excite these aligned protons to higher energy states. As they return to their original state, they will release this energy as radio waves. The frequency of the radio waves depends on the local magnetic field and by varying this over a subject, it is possible to build the images we are familiar with. In general, MRI has not been sufficiently sensitive or specific in the assessment of diffuse liver disease for clinical use. However, because of the specific characteristics of fat and iron, it may be useful in the assessment of hepatic steatosis and iron overload. Magnetic resonance imaging is useful in the assessment of focal liver disease, particularly in conjunction with contrast agents. Haemangiomas have a characteristic bright appearance on T-2 weighted images because of the slow flowing blood in dilated sinusoids. Focal nodular hyperplasia (FNH) has a homogenous appearance, and enhances early in the arterial phase after gadolinium injection, while the central scar typically enhances late. Hepatic adenomas have a more heterogenous appearance and also enhance in the arterial phase, but less briskly than FNH. Hepatocellular carcinoma is similar to an adenoma, but typically occurs in a cirrhotic liver and has earlier washout of contrast. The appearance of metastases depends on the underlying primary malignancy. Overall, MRI appears more sensitive and specific than computed tomography with contrast for the detection and evaluation of malignant lesions. (C) 2000 Blackwell Science Asia Pty Ltd.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Background. A decline in muscle mass and muscle strength characterizes normal aging. As clinical and animal studies show it relationship between higher cytokine levels and low muscle mass, the aim of this study was to investigate whether markers, of inflammation are associated with muscle mass and strength in well-functioning elderly persons. Methods. We Used baseline data (1997-1998) of the Health, Aging, and Body Composition (Health ABC) Study on 3075 black and white men and women aged 70-79 years. Midthigh muscle cross-sectional area (computed tomography), appendicular muscle mass (dual-energy x-ray ab absorptiometry). isokinetic knee extensor strength (KinCom). and isometric inip strength were measured. plasma levels of interleukin-6 (IL-6) and tumor necrosis factor-alpha (TNF-alpha) were assessed by enzyme-linked immunosorbent assay (ELISA). Results. Higher cytokine levels were generally associated with lower muscle mass and lower muscle strength. The most consistent relationship across the gender and race groups was observed for IL-6 and grip strength: per SD increase in IL-6, grip strength was 1.1 to 2.4 kg lower (p < .05) after adjustment for age, clinic Site. health status, medications, physical activity. smoking. height. and body fat. Ail overall measure of elevated cytokine level was created by combining the levels of IL-6 and TNF-alpha. With the exception of white men, elderly persons having high levels of IL-6 (> 1.80 pg/ml) as well as high levels of TNF-alpha (> 3.20 pg/ml) had a smaller muscle area, less appendicular mass. a lower knee extensor strength. and a lower grip strength compared to those with low levels of both cytokines. Conclusions. Higher plasma concentrations of IL-6 and TNF-alpha are associated with lower muscle mass and lower muscle strength in well-functioning older men and women. Higher cytokine levels. as often observed in healthy older persons. may contribute to the loss Of muscle mass and strength that accompanies aging.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

A new method for the evaluation of radiotherapy 3D polymer gel dosimeters has been developed using ultrasound to assess the significant structural changes that occur following irradiation of the dosimeters. The ultrasonic parameters of acoustic speed of propagation, attenuation and transmitted signal intensity were measured as a function of absorbed radiation dose. The dose sensitivities for each parameter were determined as 1.8 x 10(-4) s m(-1) Gy(-1), 3.9 dB m(-1) Gy(-1) and 3.2 V-1 Gy(-1) respectively. All parameters displayed a strong variation with absorbed dose that continued beyond absorbed doses of 15 Gy. The ultrasonic measurements demonstrated a significantly larger dynamic range in dose response curves than that achieved with previously published magnetic resonance imaging (MRI) dose response data. It is concluded that ultrasound shows great potential as a technique for the evaluation of polymer gel dosimeters.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Off-resonance RF pre-saturation was used to obtain contrast in MRI images of polymer gel dosimeters irradiated to doses up to 50 Gy. Two different polymer gel dosimeters composed of 2-hydroxyethyl-acryl ate or methacrylic acid monomers mixed with N, N'-methylene-bisacrylamide (BIS), dispersed in an aqueous gelatin matrix were evaluated. Radiation-induced polymerization of the co-monomers generates a fast-relaxing insoluble polymer. Saturation of the polymer using off-resonance Gaussian RF pulses prior to a spin-echo read-out with a short echo time leads to contrast that is dependent on the absorbed dose. This contrast is attributed to magnetization transfer (MT) between free water and the polymer, and direct saturation of water was found to be negligible under the prevailing experimental conditions. The usefulness of MT imaging was assessed by computing the dose resolution obtained with this technique. We found a low value of dose resolution over a wide range of doses could be obtained with a single experiment. This is an advantage over multiple spin echo (MSE) experiments using a single echo spacing where an optimal dose resolution is achieved over only very limited ranges of doses. The results suggest MT imaging protocols may be developed into a useful tool for polymer gel dosimetry.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Background: Concerns exist regarding the effect of radiation dose from paediatric pelvic CT scans and the potential later risk of radiation-induced neoplasm and teratogenic outcomes in these patients. Objective: To assess the diagnostic quality of CT images of the paediatric pelvis using either reduced mAs or increased pitch compared with standard settings. Materials and methods: A prospective study of pelvic CT scans of 105 paediatric patients was performed using one of three protocols: (1) 31 at a standard protocol of 200 mA with rotation time of 0.75 s at 120 kVp and a pitch factor approximating 1.4; (2) 31 at increased pitch factor approaching 2 and 200 mA; and (3) 43 at a reduced setting of 100 mA and a pitch factor of 1.4. All other settings remained the same in all three groups. Image quality was assessed by radiologists blinded to the protocol used in each scan. Results: No significant difference was found between the quality of images acquired at standard settings and those acquired at half the standard mAs. The use of increased pitch factor resulted in a higher proportion of poor images. Conclusions: Images acquired at 120 kVp using 75 mAs are equivalent in diagnostic quality to those acquired at 150 mAs. Reduced settings can provide useful imaging of the paediatric pelvis and should be considered as a standard protocol in these situations.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Direct and simultaneous observation of root growth and plant water uptake is difficult because soils are opaque. X-ray imaging techniques such as projection radiography or Computer Tomography (CT) offer a partial alternative to such limitations. Nevertheless, there is a trade-off between resolution, large field-of-view and 3-dimensionality: With the current state of the technology, it is possible to have any two. In this study, we used X-ray transmission through thin-slab systems to monitor transient saturation fields that develop around roots as plants grow. Although restricted to 2-dimensions, this approach offers a large field-of-view together with high spatial and dynamic resolutions. To illustrate the potential of this technology, we grew peas in 1 cm thick containers filled with soil and imaged them at regular intervals. The dynamics of both the root growth and the water content field that developed around the roots could be conveniently monitored. Compared to other techniques such as X-ray CT, our system is relatively inexpensive and easy to implement. It can potentially be applied to study many agronomic problems, such as issues related to the impact of soil constraints (physical, chemical or biological) on root development.