860 resultados para Leeds Phantom
Resumo:
In this report we will investigate the effect of negative energy density in a classic Friedmann cosmology. Although never measured and possibly unphysical, the evolution of a Universe containing a significant cosmological abundance of any of a number of hypothetical stable negative energy components is explored. These negative energy (Ω < 0) forms include negative phantom energy (w<-1), negative cosmological constant (w=-1), negative domain walls (w=-2/3), negative cosmic strings (w= -1/3), negative mass (w=0), negative radiation (w=1/3), and negative ultra-light (w > 1/3). Assuming that such universe components generate pressures as perfect fluids, the attractive or repulsive nature of each negative energy component is reviewed. The Friedmann equations can only be balanced when negative energies are coupled to a greater magnitude of positive energy or positive curvature, and minimal cases of both of these are reviewed. The future and fate of such universes in terms of curvature, temperature, acceleration, and energy density are reviewed including endings categorized as a Big Crunch, Big Void, or Big Rip and further qualified as "Warped", "Curved", or "Flat", "Hot" versus "Cold", "Accelerating" versus" Decelerating" versus "Coasting". A universe that ends by contracting to zero energy density is termed a Big Poof. Which contracting universes ``bounce" in expansion and which expanding universes ``turnover" into contraction are also reviewed. The name by which the ending of the Universe is mentioned is our own nomenclature.
Resumo:
OBJECTIVE: Measures to reduce radiation exposure and injected iodine mass are becoming more important with the widespread and often repetitive use of pulmonary CT angiography (CTA) in patients with suspected pulmonary embolism. In this retrospective study, we analyzed the capability of 2 low-kilovoltage CTA-protocols to achieve these goals. MATERIALS AND METHODS: Ninety patients weighing less than 100 kg were examined by a pulmonary CTA protocol using either 100 kVp (group A) or 80 kVp (group B). Volume and flow rate of contrast medium were reduced in group B (75 mL at 3 mL/s) compared with group A (100 mL at 4 mL/s). Attenuation was measured in the central and peripheral pulmonary arteries, and the contrast-to-noise ratios (CNR) were calculated. Entrance skin dose was estimated by measuring the surface dose in an ovoid-cylindrical polymethyl methacrylate chest phantom with 2 various dimensions corresponding to the range of chest diameters in our patients. Quantitative image parameters, estimated effective dose, and skin dose in both groups were compared by the t test. Arterial enhancement, noise, and overall quality were independently assessed by 3 radiologists, and results were compared between the groups using nonparametric tests. RESULTS: Mean attenuation in the pulmonary arteries in group B (427.6 +/- 116 HU) was significantly higher than in group A (342.1 +/- 87.7 HU; P < 0.001), whereas CNR showed no difference (group A, 20.6 +/- 7.3 and group B, 22.2 +/- 7.1; P = 0.302). Effective dose was lower by more than 40% with 80 kVp (1.68 +/- 0.23 mSv) compared with 100 kVp (2.87 +/- 0.88 mSv) (P < 0.001). Surface dose was significantly lower at 80 kVp compared with 100 kVp at both phantom dimensions (2.75 vs. 3.22 mGy; P = 0.027 and 2.22 vs. 2.73 mGy; P = 0.005, respectively). Image quality did not differ significantly between the groups (P = 0.151). CONCLUSIONS: Using 80 kVp in pulmonary CTA permits reduced patient exposure by 40% and CM volume by 25% compared with 100 kVp without deterioration of image quality in patients weighing less than 100 kg.
Resumo:
Rapid diagnostic tests (RDT) are sometimes recommended to improve the home-based management of malaria. The accuracy of an RDT for the detection of clinical malaria and the presence of malarial parasites has recently been evaluated in a high-transmission area of southern Mali. During the same study, the cost-effectiveness of a 'test-and-treat' strategy for the home-based management of malaria (based on an artemisinin-combination therapy) was compared with that of a 'treat-all' strategy. Overall, 301 patients, of all ages, each of whom had been considered a presumptive case of uncomplicated malaria by a village healthworker, were checked with a commercial RDT (Paracheck-Pf). The sensitivity, specificity, and positive and negative predictive values of this test, compared with the results of microscopy and two different definitions of clinical malaria, were then determined. The RDT was found to be 82.9% sensitive (with a 95% confidence interval of 78.0%-87.1%) and 78.9% (63.9%-89.7%) specific compared with the detection of parasites by microscopy. In the detection of clinical malaria, it was 95.2% (91.3%-97.6%) sensitive and 57.4% (48.2%-66.2%) specific compared with a general practitioner's diagnosis of the disease, and 100.0% (94.5%-100.0%) sensitive but only 30.2% (24.8%-36.2%) specific when compared against the fulfillment of the World Health Organization's (2003) research criteria for uncomplicated malaria. Among children aged 0-5 years, the cost of the 'test-and-treat' strategy, per episode, was about twice that of the 'treat-all' (U.S.$1.0. v. U.S.$0.5). In older subjects, however, the two strategies were equally costly (approximately U.S.$2/episode). In conclusion, for children aged 0-5 years in a high-transmission area of sub-Saharan Africa, use of the RDT was not cost-effective compared with the presumptive treatment of malaria with an ACT. In older patients, use of the RDT did not reduce costs. The question remains whether either of the strategies investigated can be made affordable for the affected population.
Resumo:
The double-echo-steady-state (DESS) sequence generates two signal echoes that are characterized by a different contrast behavior. Based on these two contrasts, the underlying T2 can be calculated. For a flip-angle of 90 degrees , the calculated T2 becomes independent of T1, but with very low signal-to-noise ratio. In the present study, the estimation of cartilage T2, based on DESS with a reduced flip-angle, was investigated, with the goal of optimizing SNR, and simultaneously minimizing the error in T2. This approach was validated in phantoms and on volunteers. T2 estimations based on DESS at different flip-angles were compared with standard multiecho, spin-echo T2. Furthermore, DESS-T2 estimations were used in a volunteer and in an initial study on patients after cartilage repair of the knee. A flip-angle of 33 degrees was the best compromise for the combination of DESS-T2 mapping and morphological imaging. For this flip angle, the Pearson correlation was 0.993 in the phantom study (approximately 20% relative difference between SE-T2 and DESS-T2); and varied between 0.429 and 0.514 in the volunteer study. Measurements in patients showed comparable results for both techniques with regard to zonal assessment. This DESS-T2 approach represents an opportunity to combine morphological and quantitative cartilage MRI in a rapid one-step examination.
Resumo:
OBJECTIVE: The standard technique of two-dimensional intra-arterial digital subtraction angiography (2D-DSA) for the imaging of experimental rabbit aneurysms is invasive and has considerable surgical risks. Therefore, minimally invasive techniques ideally providing three-dimensional imaging for intervention planning and follow-up are needed. This study evaluates the feasibility and quality of three-dimensional 3-T magnetic resonance angiography (3D-3T-MRA) and compares 3D-3T-MRA with 2D-DSA in experimental aneurysms in the rabbit. METHOD: Three microsurgically created aneurysms in three rabbits were evaluated using 2D-DSA and 3D-3T-MRA. Imaging of the aneurysms was performed 2 weeks after creation using 2D-DSA and contrast-enhanced (CE) MRA. Measurements included aneurysm dome (length and width) and aneurysm neck. Aneurysm volumes were determined using CE-MRA. RESULTS: The measurements of the aneurysms' dimensions and the evaluation of vicinity vessels with both techniques showed a good correlation. The mean aneurysm length, aneurysm width and neck width measured with DSA (6.9, 4.1 and 2.8 mm, respectively) correlated with the measurements performed in 3D-3T-MRA (6.9, 4 and 2.5 mm, respectively). The mean aneurysm volumes measured with CE-MRA was 46.7 mm(3). CONCLUSION: 3D-3T CE-MRA is feasible and less invasive and is a safer imaging alternative to DSA for experimental aneurysm. Additionally, aneurysm technique this precise offers the possibility of repetitive 3D aneurysm volumetry for long-term follow-up studies after endovascular aneurysm occlusion.
Resumo:
BACKGROUND AND PURPOSE: It is unclear whether very old patients benefit from organized inpatient (stroke unit) care. The aim of this work was to compare the clinical outcome of patients with first-ever ischemic stroke aged either >or=80 or <80 years who were treated conservatively (without cerebral revascularization) in a university-based stroke unit. PATIENTS AND METHODS: We included 147 (11%) patients >or=80 years and 1241 (89%) patients, <80 years. All patients underwent clinical examination, blood tests, electrocardiography (ECG), brain imaging and cerebrovascular ultrasound. Additional investigations were done at the discretion of the treating physician. The modified Rankin scale (mRS) score was used to assess the 3-month outcome (favorable: mRS, 0-1; poor: mRS, 2-6; death of any cause). RESULTS: Stroke severity did not differ between both groups [median National Institutes of Health Stroke Scale (NIHSS) score, 4]. Younger patients underwent magnetic resonance (MR) imaging of the brain, MR and catheter angiography and echocardiography (p<0.001) more frequently, whereas older patients underwent computed tomography of the brain and 24-hour ECG (p<0.001) more frequently. Stroke prevention included clopidogrel (p<0.001) and heparin (p=0.047) more often in older patients and aspirin (p=0.016) in younger patients. Recurrent ischemic events were similarly frequent in old (7%) and young (5%) patients. Favorable outcome was equally prevalent in old (71%) and young (76%) patients, whereas mortality was higher in older patients (7 and 3%, p=0.007). Admission NIHSS score >or=12 was the only independent predictor of unfavorable outcome (odds ratio, 19.6; 95% confidence interval, 9.7-39.6; p<0.001). CONCLUSION: Our work provides further evidence that also the oldest patients may benefit from conservative stroke unit care.
Resumo:
The aim of this study was to determine the influence of individual factors on differences in bone mineral density (BMD) using dual X-ray absorptiometry pencil beam (PB) and fan beam (FB) modes in vivo and in vitro. PB.BMD and FB.BMD of 63 normal Caucasian females ages 21-80 yr were measured at the lumbar spine and hip. Residuals of the FB/PB regression were used to assess the impact of height, weight, adiposity index (AI) (= weight/height(3/2)), back tissue thickness, and PB.BMD, respectively, on FB/PB difference. The Hologic Anthropomorphic Spine Phantom (ASP) was measured using the PB and FB modes at two different levels to assess the impact of scanning mode and focus distance. The European Spine Phantom (ESP) prototype, a geometrically well-defined phantom with known vertebral densities, was measured using PB and FB modes and analyzed manually to determine the impact of bone density on FB/PB difference and automatically to determine the impact of edge detection on FB/PB difference. Population BMD results were perfectly correlated, but significantly overestimated by 1.5% at the lumbar spine and underestimated by 0.7% at the neck, 1.8% at the trochanter, and 2.0% at the total hip, respectively, when using the FB compared with PB mode. At the lumbar spine, the FB/PB residual correlated negatively with height (r = 0.34, p < 0.01) and PB.BMD (r = 0.48, p <: 0. 0001) and positively with AI (r = 0.26, p < 0.05). At the hip, residual of trochanter correlated positively with weight (r = 0.36, p < 0.01) and AI (r = 0.36, p < 0.01). The FB mode significantly increased ASP BMD by 0.7% compared with PB. Using the FB mode, increasing focus distance significantly (p < 0.001) decreased area and bone mineral content, but not BMD. By contrast, increasing focus distance significantly decreased PB.BMD by 0.7%. With the ESP, the PB mode supplied accurate projected are of the bone (AREA) results but significant underestimation of specified BMD in the manual analysis. The FB mode significantly underestimated PB. AREA by 2.9% but fitted specified BMD quite well. FB/PB overestimation was larger for the low-density (+8.7%) than for the high-density vertebra (+4. 9%). The automated analysis resulted in more than 14% underestimation of PB. AREA (low-density vertebra) and an almost 13% overestimation of PB.BMD (high-density vertebra) using FB. In conclusion, FB and PB measurements are highly correlated at the lumbar spine and hip with small but significant BMD differences related to height, adiposity, and BMD. In clinical practice, it can be erroneous to switch from one method to another, especially in women with low bone density.
Resumo:
OBJECTIVES This study examined the near visual acuity of dentists in relation to age and magnification under simulated clinical conditions. MATERIALS AND METHODS Miniaturized visual tests were performed in posterior teeth of a dental phantom head in a simulated clinical setting (dental chair, operating lamp, dental mirror). The visual acuity of 40 dentists was measured under the following conditions: (1) natural visual acuity, distance of 300 mm; (2) natural visual acuity, free choice of distance; (3) Galilean loupes, magnification of ×2.5; (4) Keplerian loupes, ×4.3; (5) operating microscope, ×4, integrated light; (6) operating microscope, ×6.4, integrated light. RESULTS The visual acuity varied widely between individuals and was significantly lower in the group ≥40 years of age (p < 0.001). Significant differences were found between all tested conditions (p < 0.01). Furthermore, a correlation between visual acuity and age was found for all conditions. The performance with the microscope was better than with loupes even with comparable magnification factors. Some dentists had a better visual acuity without optical aids than others with Galilean loupes. CONCLUSIONS Near visual acuity under simulated clinical conditions varies widely between individuals and decreases throughout life. Visual deficiencies can be compensated for with optical aids. CLINICAL RELEVANCE Newly developed miniaturized vision tests have allowed, in a clinically relevant way, to evaluate the influence of magnification and age on the near visual acuity of dentists.
Resumo:
BACKGROUND In Chopart-level amputations the heel often deviates into equinus and varus when, due to the lack of healthy anterior soft tissue, rebalancing tendon transfers to the talar head are not possible. Consequently, anterior and lateral wound dehiscence and ulceration may occur requiring higher-level amputation to achieve wound closure, with considerable loss of function for the patients. METHODS Twenty-four consecutive patients (15 diabetes, 6 trauma, and 3 tumor) had Chopart's amputation and simultaneous or delayed additional ankle dorsiflexion arthrodesis to allow for tension-free wound closure or soft tissue reconstruction, or to treat secondary recurrent ulcerations. Percutaneous Achilles tendon lengthening and subtalar arthrodesis were added as needed. Wound healing problems, time to fusion and full weight-bearing in the prosthesis, complications in the prosthesis, and the ambulatory status were assessed. Satisfaction and function were evaluated by the AmpuPro score and the validated Prosthesis Evaluation Questionnaire scale. RESULTS Five patients had successful soft tissue healing and fusions but died of their underlying disease 2 to 46 months after the operation. Two diabetic patients required a transtibial amputation. The other 17 patients were followed for 27 months (range, 13-63). The average age of the 4 women and 13 men was 53.9 years (range, 16-87). Postoperative complications included minor wound healing problems in 8 patients, wound breakdown requiring revision in 4, phantom pain in 3, residual equinus in 1, and adjacent scar carcinoma in 1 patient. The time to full weight-bearing in the prosthesis ranged from 6 to 24 weeks (mean 10). The mean AmpuPro score was 107 points (of 120), and the mean Prosthesis Evaluation Questionnaire scale was 147 points (of 200). No complications occurred with the prosthesis. Twelve patients lost 1 to 2 mobility classes (mean 0.9). The arthrodeses all healed within 2.5 months (range, 1.5 to 5 months). CONCLUSION Adding an ankle arthrodesis to a Chopart's amputation either immediately or in a delayed fashion to treat anterior soft tissue complications was a successful salvage in most patients at this amputation level. It enabled the patients to preserve the advantages of a full-length limb with terminal weight-bearing. LEVEL OF EVIDENCE Level IV, retrospective case series.
Resumo:
The acquisition of conventional X-ray radiographs remains the standard imaging procedure for the diagnosis of hip-related problems. However, recent studies demonstrated the benefit of using three-dimensional (3D) surface models in the clinical routine. 3D surface models of the hip joint are useful for assessing the dynamic range of motion in order to identify possible pathologies such as femoroacetabular impingement. In this paper, we present an integrated system which consists of X-ray radiograph calibration and subsequent 2D/3D hip joint reconstruction for diagnosis and planning of hip-related problems. A mobile phantom with two different sizes of fiducials was developed for X-ray radiograph calibration, which can be robustly detected within the images. On the basis of the calibrated X-ray images, a 3D reconstruction method of the acetabulum was developed and applied together with existing techniques to reconstruct a 3D surface model of the hip joint. X-ray radiographs of dry cadaveric hip bones and one cadaveric specimen with soft tissue were used to prove the robustness of the developed fiducial detection algorithm. Computed tomography scans of the cadaveric bones were used to validate the accuracy of the integrated system. The fiducial detection sensitivity was in the same range for both sizes of fiducials. While the detection sensitivity was 97.96% for the large fiducials, it was 97.62% for the small fiducials. The acetabulum and the proximal femur were reconstructed with a mean surface distance error of 1.06 and 1.01 mm, respectively. The results for fiducial detection sensitivity and 3D surface reconstruction demonstrated the capability of the integrated system for 3D hip joint reconstruction from 2D calibrated X-ray radiographs.
Resumo:
Purpose: The aim of this work is to evaluate the geometric accuracy of a prerelease version of a new six degrees of freedom (6DoF) couch. Additionally, a quality assurance method for 6DoF couches is proposed. Methods: The main principle of the performance tests was to request a known shift for the 6DoF couch and to compare this requested shift with the actually applied shift by independently measuring the applied shift using different methods (graph paper, laser, inclinometer, and imaging system). The performance of each of the six axes was tested separately as well as in combination with the other axes. Functional cases as well as realistic clinical cases were analyzed. The tests were performed without a couch load and with a couch load of up to 200 kg and shifts in the range between −4 and +4 cm for the translational axes and between −3° and +3° for the rotational axes were applied. The quality assurance method of the new 6DoF couch was performed using a simple cube phantom and the imaging system. Results: The deviations (mean ± one standard deviation) accumulated over all performance tests between the requested shifts and the measurements of the applied shifts were −0.01 ± 0.02, 0.01 ± 0.02, and 0.01 ± 0.02 cm for the longitudinal, lateral, and vertical axes, respectively. The corresponding values for the three rotational axes couch rotation, pitch, and roll were 0.03° ± 0.06°, −0.04° ± 0.12°, and −0.01° ± 0.08°, respectively. There was no difference found between the tests with and without a couch load of up to 200 kg. Conclusions: The new 6DoF couch is able to apply requested shifts with high accuracy. It has the potential to be used for treatment techniques with the highest demands in patient setup accuracy such as those needed in stereotactic treatments. Shifts can be applied efficiently and automatically. Daily quality assurance of the 6DoF couch can be performed in an easy and efficient way. Long-term stability has to be evaluated in further tests.