997 resultados para LP simples
Resumo:
Mémoire numérisé par la Direction des bibliothèques de l'Université de Montréal.
Resumo:
Mémoire numérisé par la Direction des bibliothèques de l'Université de Montréal.
Resumo:
Mémoire numérisé par la Direction des bibliothèques de l'Université de Montréal.
Resumo:
Mémoire numérisé par la Direction des bibliothèques de l'Université de Montréal.
Resumo:
Lipoprotein-associated phospholipase A2 (Lp-PLA2) hydrolyses oxidized low-density lipoproteins into proinflammatory products, which can have detrimental effects on vascular function. As a specific inhibitor of Lp-PLA2, darapladib has been shown to be protective against atherogenesis and vascular leakage in diabetic and hypercholesterolemic animal models. This study has investigated whether Lp-PLA2 and its major enzymatic product, lysophosphatidylcholine (LPC), are involved in blood-retinal barrier (BRB) damage during diabetic retinopathy. We assessed BRB protection in diabetic rats through use of species-specific analogs of darapladib. Systemic Lp-PLA2 inhibition using SB-435495 at 10 mg/kg (i.p.) effectively suppressed BRB breakdown in streptozotocin-diabetic Brown Norway rats. This inhibitory effect was comparable to intravitreal VEGF neutralization, and the protection against BRB dysfunction was additive when both targets were inhibited simultaneously. Mechanistic studies in primary brain and retinal microvascular endothelial cells, as well as occluded rat pial microvessels, showed that luminal but not abluminal LPC potently induced permeability, and that this required signaling by the VEGF receptor 2 (VEGFR2). Taken together, this study demonstrates that Lp-PLA2 inhibition can effectively prevent diabetes-mediated BRB dysfunction and that LPC impacts on the retinal vascular endothelium to induce vasopermeability via VEGFR2. Thus, Lp-PLA2 may be a useful therapeutic target for patients with diabetic macular edema (DME), perhaps in combination with currently administered anti-VEGF agents.
Resumo:
La conception de la structure d’une chaussée dépend en grande partie des caractéristiques du sol qui constituera l’infrastructure, telles que ses propriétés mécaniques réversibles et sa sensibilité à l’eau et au gel. Ces paramètres peuvent être mesurés en laboratoire grâce à l’exécution d’essais très fiables, mais laborieux et dispendieux comme par exemple les essais en cellule triaxiale et celui du potentiel de ségrégation en cellule de gel. L’utilisation des équipements portatifs, comme le déflectomètre LWD et le Percomètre®, permet d’effectuer une évaluation des propriétés du sol. Dix types de sols d’infrastructure ont été testés en laboratoire; les résultats ont été validés avec des essais in situ et corrélés avec les modules réversibles et les potentiels de ségrégation obtenus en laboratoire. Des modèles mathématiques ont été développés permettant une quantification adéquate du module réversible et du potentiel de ségrégation en fonction des propriétés géotechniques du sol.
Resumo:
Therapeutic plasmapheresis allows the extracorporeal removal of plasmatic lipoproteins (Lipid-apheresis) (LA). It can be non selective (non specific), semi - selective or selective low density lipoprotein-lipoprotein(a) (specific [LDL- Lp(a)] apheresis) (Lipoprotein apheresis, LDLa). The LDL removal rate is a perfect parameter to assess the system efficiency. Plasma-Exchange (PEX) cannot be considered either specific nor, selective. In PEX the whole blood is separated into plasma and its corpuscular components usually through centrifugation or rather filtration. The corpuscular components mixed with albumin solution plus saline (NaCl 0.9%) solution at 20%-25%, are then reinfused to the patient, to substitute the plasma formerly removed. PEX eliminates atherogenic lipoproteins, but also other essential plasma proteins, such as albumin, immunoglobulins, and hemocoagulatory mediators. Cascade filtration (CF) is a method based on plasma separation and removal of plasma proteins through double filtration. During the CF two hollow–fiber filters with pores of different diameter are used to eliminate the plasma components of different weight and molecular diameter. A CF system uses a first polypropylene filter with 0.55 µm diameter pores and a second one of diacetate of cellulose with 0.02 µm pores. The first filter separates the whole blood, and the plasma is then perfused through a second filter which allows the recovery of molecules with a diameter lower than 0.02 µm, and the removal of molecules larger in diameter as apoB100–containing lipoproteins. Since both albumin and immunoglobulins are not removed, or to a negligible extent, plasma-expanders, substitution fluids, and in particular albumin, as occurs in PEX are not needed. CF however, is characterized by lower selectivity since removes also high density lipoprotein (HDL) particles which have an antiatherogenic activity. In the 80’s, a variation of Lipid-apheresis has been developed which allows the LDL-cholesterol (LDLC) (-61%) and Lp(a) (-60%) removal from plasma through processing 3 liters of filtered plasma by means of lipid-specific thermofiltration, LDL immunoadsorption, heparin-induced LDL precipitation, LDL adsorption through dextran sulphate. More recently (90’s) the DALI®, and the Liposorber D® hemoperfusion systems, effective for apoB100- containing lipoproteins removal have been developed. All the above mentioned systems are established LDL-apheresis techniques referable to the generic definition of LDLa. However, this last definition cannot describe in an appropriate manner the removal of another highly atherogenic lipoprotein particle: the Lp(a). Thus it would be better to refer the above mentioned techniques to the wider scientific and technical concept of lipoprotein apheresis. Lipid apheresis - Lipoprotein apheresis - LDL-apheresis - Severe Dyslipidemia.
Resumo:
Os nanomateriais apresentam uma escala na qual ao menos uma das dimensões varia entre 1 e 100 nm e possuem propriedades químicas, físicas ou biológicas dependentes da nanoestrutura e que lhes confere características funcionais de interesse para fins comerciais ou aplicações na área médica. Dentre os nanomateriais mais estudados e utilizados, destacam-se os de carbono, que incluem os fulerenos e os nanotubos de carbono (NT). Uma potencial utilização dos nanomateriais de carbono é na área biomédica, já que estes podem interagir com os sistemas biológicos em nível molecular e supramolecular com alto grau de especificidade. Em contrapartida, é importante considerar que os nanotubos de carbono podem exercer efeitos tóxicos, tendo como possível mecanismo o estresse oxidativo. Sendo assim, o objetivo desse trabalho foi investigar a ação dos nanotubos de carbono de parede única funcionalizados com polietilenoglicol (SWNT-PEG) em Danio rerio “zebrafish” (Teleostei, Cyprinidae). Avaliaram-se parâmetros bioquímicos, histológicos, comportamentais e de biodistribuição para entender como esse material se comporta in vitro e in vivo. Foi observado que o tipo de funcionalização é determinante para a ação desse material em meio biológico. No experimento in vitro o SWNT-PEG não mostrou efeito pró-oxidante nas avaliações de peroxidação lipídica, capacidade antioxidante total, conteúdo de GSH e atividade de GCL. Na exposição intraperitoneal em zebrafish constatou-se a agregação e geração de processo inflamatório, o que sugere que a cadeia de PEG utilizada para a funcionalização dos NT possui um tamanho inadequado e/ou uma funcionalização ineficiente para manter a estabilidade do material em meio biológico e evitar uma resposta inflamatória por parte do organismo exposto. Possivelmente devido a esta característica do nanomaterial, nas análises de biodistribuição, através de espectroscopia Raman, não se observou distribuição de SWNT-PEG no sistema nervoso central de zebrafish. No entanto, através da análise histológica foi observado processo inflamatório no tecido nervoso central, bem como alterações comportamentais avaliadas na tarefa de campo aberto.
Resumo:
Tissue engineering is a real challenge for the treatment of cartilage pathologies. In this field, biomimetic hydrogels based on natural polymers are among the most commonly used matrices. A hydrogel made of silanized hydroxypropylmethylcellulose (HPMC-Si) is especially promising because it can be injected in cartilaginous lesions by minimally invasive surgery. However, the current synthesis of HPMC-Si is limited by the insolubility of hydroxypropylmethylcellulose (HPMC). This thesis work was focused on finding new synthesis conditions for the design of HPMC-Si hydrogel. In order to obtain a complete solubilization of HPMC and to improve its functionalization by the (3-glycidyloxypropyl) trimethoxysilane (GPTMS), the use of ionic liquids (IL), which are excellent solvents for polysaccharides, was undertaken. The beginning of this study was first devoted to the selection of an IL and then to the development of new reaction conditions. With these new conditions, higher silicon rates were obtained for HPMC modified in ionic liquid medium, however no hydrogel could be formed. The second part was therefore devoted to the synthesis of GPTMS 13C. Indeed, thanks to this radiolabeling, a structural characterization by 13C NMR of the HPMC-Si could be achieved. Finally, the reactivity in organic solvents of three organosilanes, including the GPTMS, was investigated toward nucleophiles representing the common functions found in natural polymers (e.g. -NH2, -OH, -SH). The results of this thesis have provided insights into the GPTMS reactivity in organic medium and thus paves the way to new conditions for the silanization of polysaccharides.
Resumo:
É cada vez mais frequente o diagnóstico de quisto do ovário pelo uso crescente de exames radiológicos. É essencial a distinção entre quisto simples e quisto complexo, pois a sua abordagem é diferente, sendo o algoritmo de abordagem adaptado à mulher pré- ou pós-menopáusica [1]. A recomendação inicial a seguir varia em função do tamanho da lesão e do valor do CA 125.
Resumo:
O rendimento operacional em campo estima o total de area nao trabalhada em virtude do tempo consumido com o preparo da maquina, com as idas e vindas do galpao ao campo, como nao-aproveitamento integral das dimensoes dos orgaos ativos, com o tempo gasto nos retornos nas extremidades, e com as interrupcoes do trabalho. Este trabalho testa o modelo simples com variacao de diferentes variaveis independentes, com base nas informacoes existentes na literatura, e os valores encontrados nas experimentacoes realizadas para avaliar os efeitos de comprimento da parcela, numero de implementos usados, tipo de chassi porta-implementos, que podem efetuar os valores de V, T e Eft.
Análisis de las políticas públicas de regulación de precios en los fertilizantes simples en Colombia
Resumo:
Bogotá (Colombia): Universidad de La Salle. Facultad de Ciencias Agropecuarias. Maestría en Agronegocios
Resumo:
257 p.