907 resultados para INTERNATIONAL DIAGNOSTIC INTERVIEW
Resumo:
Objective: The objective of the study is to investigate the results of the newborn hearing screening program carried out in a Public Hospital in Brazil, in the first 3 years regarding: (1) the prevalence of hearing impairment; (2) the influence of the universal hearing screening program on the age at which the diagnosis of hearing loss is defined; (3) the cost effectiveness of the program; (4) the outcomes, in terms of the age in which the hearing rehabilitation started. Methods: A descriptive study of the first 3 years after starting the universal newborn hearing screening in a Public Hospital of Bauru, Sao Paulo state, Brazil. The screening method consists of a two-stage screening approach with transient otoacoustic emissions (TOAE), conducted by an audiologist. If the outcome in the second-stage screening is REFER, the infant is submitted to diagnostic follow-up testing and intervention at the Audiology and Speech Pathology Clinic at the University of Sao Paulo, campus of Bauru. The evaluation of the costs of the universal newborn hearing screening program per each screened newborn (around 4000/year) was done based on a proposal by the National Center for Hearing Assessment and Management, of the Utah State University, United States of America. Results: 11,466 newborns were submitted to hearing screening, corresponding to 90.52% of the living newborns. The prevalence of sensorineural hearing loss was 0.96:1000. Of the 11 children with sensorineural hearing loss, eight children received hearing aids and five started the therapeutic process before the age of 1. Currently, four children between the ages of 11 months and 2 years old were submitted to cochlear implant surgery. The cost of hearing screening was US$7.00 and the annual cost of the universal newborn hearing screening program was US$26,940.47. Conclusion: The hospital-based universal newborn hearing screening carried out through the Brazilian National Health System is viable, with promising results. However, in a country such as Brazil, which presents large socio-economic differences, the same type of analyses should be performed in several regions, so as to take into account specific aspects, to implement the newborn hearing screening along with the Public System. (C) 2010 Elsevier Ireland Ltd. All rights reserved.
Resumo:
To evaluate the effect of oral rehabilitation with immediately loaded fixed implant-supported mandibular prostheses on chewing and swallowing in elderly individuals. Materials and Methods: Fifteen completely edentulous patients aged more than 60 years (10 women and five men), wearing removable dentures in both arches, had a mandibular denture replaced by an implant-supported prosthesis. All individuals were evaluated before surgery and again 3, 6, and 18 months later with regard to mastication and swallowing conditions. Examinations entailed an interview, evaluation of tactile sensitivity of the face, and observation of food intake, masticatory type, formations of bolus, and pain during mastication. The swallowing evaluation comprised observation of clinical signs related to the oral and pharyngeal stages of swallowing, as well as the presence of oral residue. The findings of different evaluations before and 3, 6, and 18 months after the surgical-prosthetic procedure were statistically compared by analysis of variance for repeated measurements at a significance level of 5%. Results: The questionnaire revealed a reduction in complaints of masticatory and swallowing disturbances, a decreased need for liquid ingestion, and reduced choking and coughing. Clinical evaluations showed improved oral function and bolus propulsion for both solid and paste-consistency foods; pain during mastication was also resolved. Conclusion: Treatment with mandibular implant-supported dentures had positive effects on the clinical aspects of mastication and swallowing in elderly individuals. INT J ORAL MAXILLOFAC IMPLANTS 2009; 24:110-117
Resumo:
Introduction: Recently developed portable dental X-ray units increase the mobility of the forensic odontologists and allow more efficient X-ray work in a disaster field, especially when used in combination with digital sensors. This type of machines might also have potential for application in remote areas, military and humanitarian missions, dental care of patients with mobility limitation, as well as imaging in operating rooms. Objective: To evaluate radiographic image quality acquired by three portable X-ray devices in combination with four image receptors and to evaluate their medical physics parameters. Materials and methods: Images of five samples consisting of four teeth and one formalin-fixed mandible were acquired by one conventional wall-mounted X-ray unit, MinRay (R) 60/70 kVp, used as a clinical standard, and three portable dental X-ray devices: AnyRay (R) 60 kVp, Nomad (R) 60 kVp and Rextar (R) 70 kVp, in combination with a phosphor image plate (PSP), a CCD, or a CMOS sensor. Three observers evaluated images for standard image quality besides forensic diagnostic quality on a 4-point rating scale. Furthermore, all machines underwent tests for occupational as well as patient dosimetry. Results: Statistical analysis showed good quality imaging for all system, with the combination of Nomad (R) and PSP yielding the best score. A significant difference in image quality between the combination of the four X-ray devices and four sensors was established (p < 0.05). For patient safety, the exposure rate was determined and exit dose rates for MinRay (R) at 60 kVp, MinRay (R) at 70 kVp, AnyRay (R), Nomad (R) and Rextar (R) were 3.4 mGy/s, 4.5 mGy/s, 13.5 mGy/s, 3.8 mGy/s and 2.6 mGy/s respectively. The kVp of the AnyRay (R) system was the most stable, with a ripple of 3.7%. Short-term variations in the tube output of all the devices were less than 10%. AnyRay (R) presented higher estimated effective dose than other machines. Occupational dosimetry showed doses at the operator`s hand being lowest with protective shielding (Nomad (R): 0.1 mu Gy). It was also low while using remote control (distance > 1 m: Rextar (R) < 0.2 mu Gy, MinRay (R) < 0.1 mu Gy). Conclusions: The present study demonstrated the feasibility of three portable X-ray systems to be used for specific indications, based on acceptable image quality and sufficient accuracy of the machines and following the standard guidelines for radiation hygiene. (C) 2010 Elsevier Ireland Ltd. All rights reserved.
Resumo:
The aim of this study was to analyze if the presence of impacted third molars, and their positions in the mandibular angle, can change the bone quality in this area, considering the measure of the cortical thickness in this region as representative or not for mandible fracture risk. Software was used to analyze 50 digital images from panoramic radiographs of patients who had one or two impacted third molars in the mandible, and 30 digital images of patients with agenesis of the mandibular third molar. The thickness of the cortical region of the mandible was measured; it was possible to draw a parallel line to the posterior portion of the mandible and a parallel line to the body of this bone on each side of the image. At the intersection of these lines near the distal portion of the second molar, another line was set up to serve as reference in the cortical thickness measurement. It could be concluded that the cortical thickness of the mandibular angle in male patients without impacted third molars was greater than the thickness in patients with these teeth, and no difference in thickness was found for the female group.
Resumo:
The research diagnostic criteria for temporomandibular disorders (RDC/TMD) are used for the classification of patients with temporomandibular disorders (TMD). Surface electromyography of the right and left masseter and temporalis muscles was performed during Maximum teeth clenching in 103 TMD patients subdivided according to the RDC/TMD into 3 non-overlapping groups: (a) 25 myogenous; (b) 61 arthrogenous; and (c) 17 psycogenous patients. Thirty-two control subjects matched for sex and age were also measured. During clenching, standardized total muscle activities (electromyographic potentials over time) significantly differed: 131.7 mu V/mu V s % in the normal subjects, 117.6 mu V/mu V s % in the myogenous patients, 105.3 mu V/mu V s % in the arthrogenous patients, 88.7 mu V/mu V s % in the psycogenous patients (p < 0.001, analysis of covariance). Symmetry in the temporalis muscles was larger in normal subjects (86.3%) and in myogenous patients (84.9%) than in arthrogenous (82.7%), and psycogenous patients (80.5%) (p=0.041). No differences were found for masseter muscle symmetry and torque coefficient (p>0.05). Surface electromyography of the masticatory muscles allowed an objective discrimination among different RDC/TMD subgroups. This evaluation could assist conventional clinical assessments. (C) 2007 Elsevier Ltd. All rights reserved.
Resumo:
This paper develops a theory that firms seek out new country markets on the basis of expected commercial returns. These expectations depend on judgements about the attractiveness of the market and the firm's competitive position in it, which in turn are influenced by informants. It is the number and strengths of these informants that will underlie the probability of a country being identified and assessed as a new market by any firm.
Resumo:
No Abstract
Resumo:
Objective. The diagnostic value of tests for antimyeloperoxidase antibodies (anti-MPO) for systemic vasculitis is less established than that for cytoplasmic antineutrophil cytoplasmic antibody (cANCA)/antiproteinase 3 antibodies (anti-PR3). Controversy exists regarding the optimal utilization of indirect immunofluorescence (IIF) ANCA testing versus antigen-specific ANCA testing. To summarize the pertinent data, we conducted a metaanalysis examining the diagnostic value of ANCA testing systems that include assays for anti-MPO. Methods. We performed a structured Medline search and reference list review. Target articles in the search strategy were those reporting the diagnostic value of immunoassays for anti-MPO for the spectrum of systemic necrotizing vasculitides that includes Wegener's granulomatosis, microscopic polyangiitis, the Churg-Strauss syndrome, and isolated pauci-immune necrotizing or crescentic glomerulonephritis, regardless of other types of ANCA tests. Inclusion criteria required specification of a consecutive or random patient selection method and the use of acceptable criteria for the diagnosis of vasculitis exclusive of ANCA test results. Weighted pooled summary estimates of sensitivity and specificity were calculated for anti-MPO alone, anti-MPO + perinuclear ANCA (pANCA), and anti-MPO/pANCA + anti-PR3/cANCA. Results. Of 457 articles reviewed, only 7 met the selection criteria. Summary estimates of sensitivity and specificity (against disease controls only) of assays for anti-MPO for the diagnosis of systemic necrotizing vasculitides were 37.1% (confidence interval 26.6% to 47.6%) and 96.3% (CI 94.1% to 98.5%), respectively. When the pANCA pattern by IIF was combined with anti-MPO testing, the specificity improved to 99.4%, with a lower sensitivity, 31.5%. The combined ANCA testing system (anti-PR3/cANCA + anti-MPO/pANCA) increased the sensitivity to 85.5% with a specificity of 98.6%. Conclusion. These results suggest that while anti-MPO is relatively specific for the diagnosis of systemic vasculitis, the combination system of immunoassays for anti-MPO and IIF for pANCA is highly specific and both tests should be used together given the high diagnostic precision required for these conditions. Because patients with ANCA associated vasculitis have either anti-MPO with pANCA or anti-PR3 with cANCA, and rarely both, a combined ANCA testing system including anti-PR3/cANCA and anti-MPO/pANCA is recommended to optimize the diagnostic performance of ANCA testing. (J Rheumatol 2001;28:1584-90)
Resumo:
The 18th international papillomavirus conference took place in Barcelona, Spain in July 2000. The HPV clinical workshop was jointly organised with the annual meeting of the Spanish Association of Cervical Pathology and Colposcopy. The conference included 615 abstracts describing ongoing research in epidemiology, diagnosis/screening, treatment/prognosis, immunology/human immunodeficiency virus, vaccine development/trials, transformation/progression, replication, transcription/translation, viral protein functions, and viral and host interactions. This leader summarises the highlights presented at the conference (the full text of the abstracts and lectures can be found at www.hpv2000.com). Relevant material in Spanish can be found at www.aepcc. org.
Resumo:
Multiple frequency bioelectrical impedance analysis (MFBIA) has previously been shown to provide accurate relative measures of lymphedema in the upper limb of patients (1). This paper reports the results of a three year prospective study to evaluate the efficacy of MFBIA to predict the early onset of lymphedema in patients following treatment for breast cancer. Bioelectrical impedance measurements and circumferential measurements of each upper limb were recorded in healthy control subjects (n=60) to determine the normal range of the ratio (dominant/non-dominant) of extracellular and total limb volumes respectively. Patients undergoing surgery for the treatment of breast cancer were recruited as the study group; MFBIA and circumferential measurements were recorded pre-surgery, one month post-surgery and then at two month intervals for 24 months. One hundred and two patients were recruited into the study. Twenty patients developed lymphedema in the 24 months follow up period of this study. In each of these 20 cases MFBIA predicted the onset of the condition up to 10 months before the condition could be clinically diagnosed. Estimates of the sensitivity and specificity were both approximately 100%. At the time of detection by MFBIA, only one of the patients returned a positive test result from the total limb volumes determined from the circumferential measures. These results confirmed the suitability of the MFBIA technique as a reliable diagnostic procedure for the early detection of lymphedema.
Resumo:
Hereditary nonpolyposis colorectal cancer syndrome (HNPCC) is an autosomal dominant condition accounting for 2–5% of all colorectal carcinomas as well as a small subset of endometrial, upper urinary tract and other gastrointestinal cancers. An assay to detect the underlying defect in HNPCC, inactivation of a DNA mismatch repair enzyme, would be useful in identifying HNPCC probands. Monoclonal antibodies against hMLH1 and hMSH2, two DNA mismatch repair proteins which account for most HNPCC cancers, are commercially available. This study sought to investigate the potential utility of these antibodies in determining the expression status of these proteins in paraffin-embedded formalin-fixed tissue and to identify key technical protocol components associated with successful staining. A set of 20 colorectal carcinoma cases of known hMLH1 and hMSH2 mutation and expression status underwent immunoperoxidase staining at multiple institutions, each of which used their own technical protocol. Staining for hMSH2 was successful in most laboratories while staining for hMLH1 proved problematic in multiple labs. However, a significant minority of laboratories demonstrated excellent results including high discriminatory power with both monoclonal antibodies. These laboratories appropriately identified hMLH1 or hMSH2 inactivation with high sensitivity and specificity. The key protocol point associated with successful staining was an antigen retrieval step involving heat treatment and either EDTA or citrate buffer. This study demonstrates the potential utility of immunohistochemistry in detecting HNPCC probands and identifies key technical components for successful staining.