868 resultados para High intensity exercise


Relevância:

80.00% 80.00%

Publicador:

Resumo:

Some vols. have also a distinctive title.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The effects of attention to a lead stimulus and of its sensory properties on modulation of the acoustic blink reflex were investigated. Participants performed a reaction time task cued by an acoustic or a visual lead stimulus. In Experiment 1, half the participants were presented with sustained lead stimuli. For the remainder, the lead stimulus was discrete and consisted of two brief presentations that marked the onset and offset of a stimulus-free interval. In Experiment 2, sustained lead stimuli were presented at a low or high intensity. The attentional demands of the task enhanced blink latency and magnitude modulation during acoustic and visual lead stimuli, with blink modulation being largest at a late point during the lead stimulus. Independent of the attentional effects, blink latency and magnitude modulation were larger during sustained than during discrete acoustic lead stimuli, whereas there was no difference for visual lead stimuli. Increases in the intensity of the lead stimulus enhanced blink modulation regardless of lead stimulus modality. Attention to a lead stimulus and the properties of the lead stimulus appear to have independent effects on blink reflex modulation.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Objectives. This study examined the depth of cure and surface microhardness of Filtek Z250 composite resin (3M-Espe) (shades B1, A3, and C4) when cured with three commercially available tight emitting diode (LED) curing lights [E-light (GC), Elipar Freelight (3M-ESPE), 475H (RF Lab Systems)], compared with a high intensity quartz tungsten halogen (HQTH) light (Kerr Demetron Optilux 501) and a conventional quartz tungsten halogen (QTH) lamp (Sirona S1 dental unit). Methods. The effects of light source and resin shade were evaluated as independent variables. Depth of cure after 40 s of exposure was determined using the ISO 4049:2000 method, and Vickers hardness determined at 1.0 mm intervals. Results. HQTH and QTH lamps gave the greatest depth of cure. The three LED lights showed similar performances across all parameters, and each unit exceeded the ISO standard for depth of cure except GC ELight for shade B1. In terms of shade, LED lights gave greater curing depths with A3 shade, while QTH and HQTH tights gave greater curing depths with C4 shade. Hardness at the resin surface was not significantly different between LED and conventional curing lights, however, below the surface, hardness reduced more rapidly for the LED lights, especially at depths beyond 3 mm. Significance. Since the performance of the three LED lights meets the ISO standard for depth of cure, these systems appear suitable for routine clinical application for resin curing. (C) 2003 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Comparative studies of autonomic and somatic reflexes, such as cardiac defense and motor startle, are rare. However, examination of the pattern of covariation, independence, or interference among physiological reflexes may help to clarify their functional significance and elucidate their complex modulation by psychological factors. Here we report the results of a study that examined the pattern of interference of eye-blink startle on subsequent cardiac defense. Participants were 63 students (31 women) distributed into three groups according to the sensory modality of the eliciting stimulus during the startle trials: acoustic high intensity (105 dB), acoustic low intensity (65 dB), and visual modality. Startle trials consisted of 12 presentations of the eliciting stimulus with a duration of 50 ms, instantaneous risetime, and a variable inter-stimulus interval of 16 – 20 s.Defense trials began 20 s after the last startle trial and consisted, for all groups, of 3 presentations of the high intensity acoustic stimulus with a duration of 500 ms and an inter-stimulus interval of 215 s. Results showed a clear interference of the startle trials on the subsequent defense trials when both types of trials shared identical sensory modality (acoustic) independently of intensity: the expected pattern of cardiac defense in the first trial only appeared in the visual modality. Similar interference effects were observed in the skin conductance response. Subjective reactivity to the defense stimulus did not detect differences between conditions.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The Jameson Cell is a high intensity flotation device, which utilises induced air from the atmosphere. It was developed jointly by Mount Isa Mines and Professor Graeme Jameson of the University of Newcastle in the 1980s. It is proven to generate fine bubbles, in the order of 300 to 500 µm, in a high intensity, high shear and compact zone contained in the downcomer. This aerated mixture exits the downcomer into the pulp zone, which is the quiescent mineral and gangue separation zone. A number of Australian base metal flotation circuits feature a reverse flotation stage at the head of the circuit. Testwork and plant operating data has shown that the use of a Jameson Cell in the prefloat cleaner application has further improved prefloat gangue recovery and selectivity. Operation of a Jameson Cell in a carbonaceous/pyrite prefloat cleaner duty at the Mt Isa copper concentrator increased copper recovery and reduced pyrite in the copper concentrate. Testwork at Zinifex Century Zinc Mine showed a decrease in zinc losses by the utilisation of Jameson Cell prefloat cleaner. Appraisal of a Jameson Cell in a scalping role within the Mt Isa Copper Concentrator indicated significant benefits could be achieved.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Esta pesquisa investiga a influência de intervenções lúdicas na diminuição da ansiedade materna com mães de recém-nascidos pré-termo hospitalizados, em um hospital universitário da Grande São Paulo. São estudadas 30 mães que tiveram parto prematuro, com faixa etária entre 16 e 40 anos e escolaridade até 2º grau, por meio de estudo avaliativo-interventivo-evolutivo. Inicia-se por uma entrevista psicológica semidirigida, com o objetivo de traçar o histórico gestacional, seguida de aplicação da Escala de Ansiedade, Depressão e Irritabilidade IDA, visando identificar o nível de ansiedade materna e do Inventário de Percepção Neonatal IPN-I para verificar a expectativa das mães em relação ao comportamento de choro, alimento e vômito de seus bebês pré-termo. A seguir são efetuadas intervenções grupais lúdicas em 16 encontros, um a cada semana, de 60 minutos, segundo modelo piagetiano, que estimula processos afetivosemocionais e cognitivos. Os dados relativos ao histórico gestacional revelam que 75% das mães encontram-se na segunda gestação e já sofreram aborto ou óbito fetal; têm ida de gestacional média de 31 semanas; peso médio do bebê ao nascer de 1.640g. e tempo de internação médio de 39,93 dias. Na análise do IDA em relação à ansiedade, 75% delas apresentam escore de alta intensidade (11,25), também alto quanto à depressão (10); o escore médio (3,73) da irritabilidade exteriorizada acompanha o da irritabilidade interiorizada (3,23). A correlação entre depressão e ansiedade indica que uma reação emocional segue a outra, não havendo diferença significativa importante entre ambas (p=0,306). O IPN-I comprova que as 30 mães têm expectativas em relação ao próprio filho similares aos bebês em geral, mostrando escores médios de 8,63 e 9,20, respectivamente, confirmados pelo escore 10,0 apontado em 75% da amostra, o que configura uma alta expectativa quanto aos aspectos de sono, alimentação e vômito dos bebês. A análise qualitativa revela que a criação de grupos lúdicos mostra-se favorável, com alta adesão e motivação das mães, favorecendo a diminuição da ansiedade, a adaptação à realidade vivida e a interação mãe-bebê de forma saudável durante a internação. O estudo apresenta a trajetória interventiva de três casos emblemáticos de diferentes níveis de ansiedade, ilustrando esta evolução. Estes dados sugerem que esta modalidade de intervenção caracterize-se como uma medida de prevenção, promoção e preservação da saúde física e psíquica da mãe e do recémnascido prematuro, com repercussões na família e na sociedade.(AU)

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The performances of five different ESI sources coupled to a polystyrene-divinylbenzene monolithic column were compared in a series of LC-ESI-MS/MS analyses of Escherichia coli outer membrane proteins. The sources selected for comparison included two different modifications of the standard electrospray source, a commercial low-flow sprayer, a stainless steel nanospray needle and a coated glass Picotip. Respective performances were judged on sensitivity and the number and reproducibility of significant protein identifications obtained through the analysis of multiple identical samples. Data quality varied between that of a ground silica capillary, with 160 total protein identifications, the lowest number of high quality peptide hits obtained (3012), and generally peaks of lower intensity; and a stainless steel nanospray needle, which resulted in increased precursor ion abundance, the highest-quality peptide fragmentation spectra (5414) and greatest number of total protein identifications (259) exhibiting the highest MASCOT scores (average increase in score of 27.5% per identified protein). The data presented show that, despite increased variability in comparative ion intensity, the stainless steel nanospray needle provides the highest overall sensitivity. However, the resulting data were less reproducible in terms of proteins identified in complex mixtures -- arguably due to an increased number of high intensity precursor ion candidates.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

This paper describes physics of nonlinear ultra-short laser pulse propagation affected by plasma created by the pulse itself. Major applications are also discussed. Nonlinear propagation of the femtosecond laser pulses in gaseous and solid transparent dielectric media is a fundamental physical phenomenon in a wide range of important applications such as laser lidars, laser micro-machining (ablation) and microfabrication etc. These applications require very high intensity of the laser field, typically 1013–1015 TW/cm2. Such high intensity leads to significant ionisation and creation of electron-ion or electron-hole plasma. The presence of plasma results into significant multiphoton and plasma absorption and plasma defocusing. Consequently, the propagation effects appear extremely complex and result from competitive counteraction of the above listed effects and Kerr effect, diffraction and dispersion. The theoretical models used for consistent description of laser-plasma interaction during femtosecond laser pulse propagation are derived and discussed. It turns out that the strongly nonlinear effects such self-focusing followed by the pulse splitting are essential. These phenomena feature extremely complex dynamics of both the electromagnetic field and plasma density with different spatio-temporal structures evolving at the same time. Some numerical approaches capable to handle all these complications are also discussed. ©2006 American Institute of Physics

Relevância:

80.00% 80.00%

Publicador:

Resumo:

We describe long-period grating inscription in hydrogenated telecom fibers by use of high-intensity femto-second 352 nm laser pulses. We show that this technique allows us to fabricate high-quality 30 dB gratings of 300 μm period and 2 cm length by use of a three-photon absorption mechanism. © 2005 Optical Society of America.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

We have observed a positive change or refractive index and formation of waveguides in YAG:Cr4+ crystals, exposed to a high-intensity femtosecond laser beam. The technique is potentially suitable for fabrication of waveguide lasers in crystal materials.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Material processing using high-intensity femtosecond (fs) laser pulses is a fast developing technology holding potential for direct writing of multi-dimensional optical structures in transparent media. In this work we re-examine nonlinear diffraction theory in context of fs laser processing of silica in sub-critical (input power less than the critical power of self-focusing) regime. We have applied well known theory, developed by Vlasov, Petrishev and Talanov, that gives analytical description of the evolution of a root-mean-square beam (not necessarily Gaussian) width RRMS(z) in medium with the Kerr nonlinearity.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

We demonstrate that ultralong Raman lasers can be used to generate a transmission medium with simultaneous transparency over the spatial and the spectral domains. Numerical calculations show this cross-domain transparency to be preserved when the medium is used for transmitting high-intensity signals, which makes ultralong lasers an ideal experimental test bed for the study of multifrequency nonlinear interactions in optical fiber waveguides. Full spatiospectral transparency is experimentally obtained over a 20 nm x 20 km window.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Rotating fluidised Beds offer the potential for high intensity combustion, large turndown and extended range of fluidising velocity due to the imposition of an artificial gravitational field. Low thermal capacity should also allow rapid response to load changes. This thesis describes investigations of the validity of these potential virtues. Experiments, at atmospheric pressure, were conducted in flow visualisation rigs and a combustor designed to accommodate a distributor 200mm diameter and 80mm axial length. Ancillary experiments were conducted in a 6" diameter conventional fluidised bed. The investigations encompassed assessment of; fluidisation and elutriation, coal feed requirements, start-up and steady-state combustion using premixed propane and air, transition from propane to coal combustion and mechanical design. Assessments were made of an elutriation model and some effects of particle size on the combustion of premixed fuel gas and air. The findings were: a) more reliable start-up and control methods must be developed. Combustion of premixed propane and air led to severe mechanical and operating problems. Manual control of coal combustion was inadequate. b) Design criteria must encompass pressure loss, mechanical strength and high temperature resistance. The flow characteristics of ancillaries and the distributor must be matcheo. c) Fluidisation of a range of particle sizes was investigated. New correlations for minimum fluidisation and fully supported velocities are proposed. Some effects on elutriation of particle size and the distance between the bed surface and exhaust port have been identified. A conic distributor did not aid initial bed distribution. Furthermore, airflow instability was encountered with this distributor shape. Future use of conic distributors is not recommended. Axial solids mixing was found to be poor. A coal feeder was developed which produced uniform fuel distribution throughout the bed. The report concludes that small scale inhibits development of mechanical design and exploration of performance. future research requires larger combustors and automatic control.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Soil erosion is one of the most pressing issues facing developing countries. The need for soil erosion assessment is paramount as a successful and productive agricultural base is necessary for economic growth and stability. In Ghana, a country with an expanding population and high potential for economic growth, agriculture is an important resource; however, most of the crop production is restricted to low technology shifting cultivation agriculture. The high intensity seasonal rainfall coincides with the early growing period of many of the crops meaning that plots are very susceptible to erosion, especially on steep sided valleys in the region south of Lake Volta. This research investigated the processes of soil erosion by rainfall with the aim of producing a sediment yield model for a small semi-agricultural catchment in rural Ghana. Various types of modelling techniques were considered to discover those most applicable to the sub-tropical environment of Southern Ghana. Once an appropriate model had been developed and calibrated, the aim was to look at how to enable the scaling up of the model using sub-catchments to calculate sedimentation rates of Lake Volta. An experimental catchment was located in Ghana, south west of Lake Volta, where data on rainstorms and the associated streamflow, sediment loads and soil data (moisture content, classification and particle size distribution) was collected to calibrate the model. Additional data was obtained from the Soil Research Institute in Ghana to explore calibration of the Universal Soil Loss Equation (USLE, Wischmeier and Smith, 1978) for Ghanaian soils and environment. It was shown that the USLE could be successfully converted to provide meaningful soil loss estimates in the Ghanaian environment. However, due to experimental difficulties, the proposed theory and methodology of the sediment yield model could only be tested in principle. Future work may include validation of the model and subsequent scaling up to estimate sedimentation rates in Lake Volta.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

We report observations of the diffraction pattern resulting when a nematic liquid crystal is illuminated with two equal power, high intensity beams of light from an Ar+ laser. The time evolution of the pattern is followed from the initial production of higher diffraction orders to a final striking display arising as a result of the self-diffraction of the two incident beams. The experimental results are described with good approximation by a model assuming a phase distribution at the output plane of the liquid crystal in the form of the sum of a gaussian and a sinusoid.