939 resultados para Helix-loop-helix
Resumo:
Four new Cu(II)-azido complexes of formula [CuL(N-3)] (1), [CuL(N-3)](2) (2), [Cu7L2(N-3)(12)](n) (3), and [Cu2L(dmen)-(N-3)(3)](n) (4) (dmen = N,N-dimethylethylenediamine) have been synthesized using the same tridentate Schiff base ligand HL (2-[1-(2-dimethylaminoethylimino)ethyl]phenol, the condensation product of dmen and 2-hydroxyacetophenone). The four compounds have been characterized by X-ray structural analyses and variable-temperature magnetic susceptibility measurements. Complex 1 is mononuclear, whereas 2 is a single mu-1,1 azido-bridged dinuclear compound. The polymeric compound 3 possesses a 2D structure in which the Cu(II) ions are linked by phenoxo oxygen atoms and two different azide bridges (mu-1,1 and mu-1,1,3). The structure of complex 4 is a double helix in which two mu-1,3-azido-bridged alternating one-dimensional helical chains of CuL(N-3) and Cu(dmen)(N-3)(2) are joined together by weak mu-1,1 azido bridges and H-bonds. The complexes interconvert in solution and can be obtained in pure form by carefully controlling the conditions. The magnetic properties of compounds 1 and 2 show the presence of very weak antiferromagnetic exchange interactions mediated by a ligand pi overlap (J = -1.77) and by an asymmetric 1,1-N-3 bridge (J = -1.97 cm(-1)), respectively. Compound 3 presents, from the magnetic point of view, a decorated chain structure with both ferro- and antiferromagnetic interactions. Compound 4 is an alternating helicoidal chain with two weak antiferromagnetic exchange interactions (J -1.35 and -2.64 cm(-1)).
Resumo:
This paper discusses a new method of impedance control that has been successfully implemented on the master robot of a teleoperation system. The method involves calibrating the robot to quantify the effect of adjustable controller parameters on the impedances along its different axes. The empirical equations relating end-effector impedance to the controller's feedback gains are obtained by performing system identification tests along individual axes of the robot. With these equations, online control of end-effector stiffness and damping is possible without having to monitor joint torques or solving complex algorithms. Hard contact conditions and compliant interfaces have been effectively demonstrated on a telemanipulation test-bed using appropriate combinations of stiffness and damping settings obtained by this method.
Resumo:
This paper considers the relationship between value management and facilities management. The findings are particularly relevant to large client organisations which procure new buildings on a regular basis. It is argued that the maximum effectiveness of value management can only be achieved if it is used in conjunction with an ongoing commitment to post-occupancy evaluation. SMART value management is seen to provide the means of ensuring that an individual building design is in alignment with the client’s strategic property needs. However, it is also necessary to recognise that an organisation’s strategic property needs will continually be in a state of change. Consequentially, economic and functional under-performance can only be avoided by a regular performance audit of existing property stock in accordance with changing requirements. Such a policy will ensure ongoing competitiveness through organisational learning. While post-occupancy evaluation represents an obvious additional service to be provided by value management consultants, it is vital that the necessary additional skills are acquired. Process management skills and social science research techniques are clearly important. However, there is also a need to improve mechanisms for data manipulation. Success can only be achieved if equal attention is given to issues of process, structure and content.
Resumo:
We describe a crystal structure, at atomic resolution (1.1 Å, 100 K), of a ruthenium polypyridyl complex bound to duplex DNA, in which one ligand acts as a wedge in the minor groove, resulting in the 51° kinking of the double helix. The complex cation Λ-[Ru(1,4,5,8-tetraazaphenanthrene)2(dipyridophenazine)]2+ crystallizes in a 1∶1 ratio with the oligonucleotide d(TCGGCGCCGA) in the presence of barium ions. Each complex binds to one duplex by intercalation of the dipyridophenazine ligand and also by semiintercalation of one of the orthogonal tetraazaphenanthrene ligands into a second symmetrically equivalent duplex. The result is noncovalent cross-linking and marked kinking of DNA.
Resumo:
A four-wavelength MAD experiment on a new brominated octanucleotide is reported here. d[ACGTACG(5-BrU)], C77H81BrN30O32P7, (DNA) = 2235, tetragonal, P43212 (No. 96), a = 43.597, c = 26.268 Å, V = 49927.5 Å3, Z = 8, T = 100 K, R = 10.91% for 4312 reflections between 15.0 and 1.46 Å resolution. The self-complementary brominated octanucleotide d[ACGTACG(5-BrU)]2 has been crystallized and data measured to 1.45 Å at both 293 K and a second crystal flash frozen at 100 K. The latter data collection was carried out to the same resolution at the four wavelengths 0.9344, 0.9216, 0.9208 and 0.9003 Å, around the Br K edge at 0.92 Å and the structure determined from a map derived from a MAD data analysis using pseudo-MIR methodology, as implemented in the program MLPHARE. This is one of the first successful MAD phasing experiments carried out at Sincrotrone Elettra in Trieste, Italy. The structure was refined using the data measured at 0.9003 Å, anisotropic temperature factors and the restrained least-squares refinement implemented in the program SHELX96, and the helical parameters are compared with those previously determined for the isomorphous d(ACGTACGT)2 analogue. The asymmetric unit consists of a single strand of octamer with 96 water molecules. No countercations were located. The A-DNA helix geometry obtained has been analysed using the CURVES program.
Resumo:
d(ACGTACGT), C78H84N30O32P7.20H2O, Mr (DNA) = 2170, tetragonal, P43212 (No 96), a = 42.845 (1), b = 42.845(1), c = 24.804 (1) Å, V = 45532.5 (2) Å3, z = 8,(MoK) = 0.71069 Å,µ(MoK) = 0.10 mm-1, T = 295 K, R = 0.18 for 1994 unique reflections between 5.0 and 1.9 Å resolution. The self-complementary octanucleotide d(ACGTACGT)2 has been crystallized and its structure determined to a resolution of 1.9 Å. The asymmetric unit consists of a single strand of octamer with 20 water molecules. It is only the second example of an octanucleotide having terminal A·T base pairs whose structure has been determined by X-ray crystallography. The sequence adopts the modified A-type conformation found for all octanucleotide duplexes studied to date with the helix bent by approximately 15° and an average tilt angle of 0°. Unusually the data collection was carried out using a 3 kW molybdenum sealed-tube source. The conformational details are discussed in comparison with other closely related sequences.
Resumo:
Land snail middens occur widely throughout the circum-Mediterranean, particularly in the Maghreb and Libya, but are relatively understudied when compared with the better known coastal marine middens. The site of Taforalt (Grotte des Pigeons) in north east Morocco contains thick ashy deposits with considerable numbers of land snails, dating between 13,000 and 11,000 BP. The site has been excavated periodically since its discovery in 1908, but little attention has been paid to the land snail component. Recent excavations at the site as part of the Cemeteries and Sedentism Project has facilitated reinvestigation of the Iberomaurusian layers, including the upper ashy midden unit. This investigation addresses questions surrounding chronological variation in the lithic assemblage, subsistence strategies, population health and mortuary practices. Preliminary work on the land snails has identified a low species diversity in the grey series midden layers, characterised by the large edible species Alabastrina alabastrites, Helix cf aspersa, Dupotetia dupotetiana, Otala punctata and Cernuella sp, which appear to represent an abrupt intensification in the use of land snails as a food source. Significant quantities of associated plant material and animal bone suggest that land snails are part of a broader based diet which is adopted from around 13,000 BP.
Resumo:
If secondary structure predictions are to be incorporated into fold recognition methods, an assessment of the effect of specific types of errors in predicted secondary structures on the sensitivity of fold recognition should be carried out. Here, we present a systematic comparison of different secondary structure prediction methods by measuring frequencies of specific types of error. We carry out an evaluation of the effect of specific types of error on secondary structure element alignment (SSEA), a baseline fold recognition method. The results of this evaluation indicate that missing out whole helix or strand elements, or predicting the wrong type of element, is more detrimental than predicting the wrong lengths of elements or overpredicting helix or strand. We also suggest that SSEA scoring is an effective method for assessing accuracy of secondary structure prediction and perhaps may also provide a more appropriate assessment of the “usefulness” and quality of predicted secondary structure, if secondary structure alignments are to be used in fold recognition.
Resumo:
The disruption of the human immunolobulin E–high affinity receptor I (IgE–FcεRI) protein–protein interaction (PPI) is a validated strategy for the development of anti asthma therapeutics. Here, we describe the synthesis of an array of conformationally constrained cyclic peptides based on an epitope of the A–B loop within the Cε3 domain of IgE. The peptides contain various tolan (i.e., 1,2-biarylethyne) amino acids and their fully and partially hydrogenated congeners as conformational constraints. Modest antagonist activity (IC50 660 μM) is displayed by the peptide containing a 2,2′-tolan, which is the one predicted by molecular modeling to best mimic the conformation of the native A–B loop epitope in IgE.
Resumo:
Aircraft systems are highly nonlinear and time varying. High-performance aircraft at high angles of incidence experience undesired coupling of the lateral and longitudinal variables, resulting in departure from normal controlled flight. The aim of this work is to construct a robust closed-loop control that optimally extends the stable and decoupled flight envelope. For the study of these systems nonlinear analysis methods are needed. Previously, bifurcation techniques have been used mainly to analyze open-loop nonlinear aircraft models and investigate control effects on dynamic behavior. In this work linear feedback control designs calculated by eigenstructure assignment methods are investigated for a simple aircraft model at a fixed flight condition. Bifurcation analysis in conjunction with linear control design methods is shown to aid control law design for the nonlinear system.
Resumo:
Aims: Quinolone antibiotics are the agents of choice for treating systemic Salmonella infections. Resistance to quinolones is usually mediated by mutations in the DNA gyrase gene gyrA. Here we report the evaluation of standard HPLC equipment for the detection of mutations (single nucleotide polymorphisms; SNPs) in gyrA, gyrB, parC and parE by denaturing high performance liquid chromatography (DHPLC). Methods: A panel of Salmonella strains was assembled which comprised those with known different mutations in gyrA (n = 8) and fluoroquinolone-susceptible and -resistant strains (n = 50) that had not been tested for mutations in gyrA. Additionally, antibiotic-susceptible strains of serotypes other than Salmonella enterica serovar Typhimurium strains were examined for serotype-specific mutations in gyrB (n = 4), parC (n = 6) and parE (n = 1). Wild-type (WT) control DNA was prepared from Salmonella Typhimurium NCTC 74. The DNA of respective strains was amplified by PCR using Optimase (R) proofreading DNA polymerase. Duplex DNA samples were analysed using an Agilent A1100 HPLC system with a Varian Helix (TM) DNA column. Sequencing was used to validate mutations detected by DHPLC in the strains with unknown mutations. Results: Using this HPLC system, mutations in gyrA, gyrB, parC and parE were readily detected by comparison with control chromatograms. Sequencing confirmed the gyrA predicted mutations as detected by DHPLC in the unknown strains and also confirmed serotype-associated sequence changes in non-Typhimurium serotypes. Conclusions: The results demonstrated that a non-specialist standard HPLC machine fitted with a generally available column can be used to detect SNPs in gyrA, gyrB, parC and parE genes by DHPLC. Wider applications should be possible.
Comparing the thermal performance of horizontal slinky-loop and vertical slinky-loop heat exchangers
Resumo:
The heat pump market in the UK has grown rapidly over the last few years. Performance analyses of vertical ground-loop heat exchanger configurations have been widely carried out using both numerical modelling and experiments. However, research findings and design recommendations on horizontal slinky-loop and vertical slinky-loop heat exchangers are far fewer compared with those for vertical ground-loop heat exchanger configurations, especially where the long-term operation of the systems is concerned. The paper presents the results obtained from a numerical simulation for the horizontal slinky-loop and vertical slinky-loop heat exchangers of a ground-source heat pump system. A three-dimensional numerical heat transfer model was developed to study the thermal performance of various heat exchanger configurations. The influence of the loop pitch (loop spacing) and the depth of a vertical slinky-loop installation were investigated and the thermal performance and excavation work required for the horizontal and vertical slinky-loop heat exchangers were compared. The influence of the installation depth for vertical slinky-loop configurations was also investigated. The results of this study show that the influence of the installation depth of the vertical slinky-loop heat exchanger on the thermal performance of the system is small. The maximum difference in the thermal performance between the vertical and horizontal slinky-loop heat exchangers with the same loop diameter and loop pitch is less than 5%.
Resumo:
This paper presents results obtained from a numerical simulation for the horizontal slinky-loop heat exchanger of a ground-source heat pump system. A three-dimensional numerical model was developed and the results of the thermal performance of various heat exchanger configurations are presented. The investigation was carried out on five types of loop pitch (loop spacing), three types of loop diameter, three values of soil thermal properties, and allowing continuous and intermittent operation. Comparison was made for the heat transfer rate, the amount of pipe material needed, as well as excavation work required for the horizontal slinky-loop heat exchanger. The results indicate that system parameters have a significant effect on the thermal performance of the system