Resumo:
No safe ultrasound (US) parameters have been established to differentiate the causes of graft dysfunction.To define US parameters and identify the predictors of normal graft evolution, delayed graft function (DGF), and rejection at the early period after kidney transplantation.Between June 2012 and August 2013, 79 renal transplant recipients underwent US examination 1-3 days posttransplantation. Resistive index (RI), power Doppler (PD), and RI + PD (quantified PD) were assessed. Patients were allocated into three groups: normal graft evolution, DGF, and rejection.Resistive index of upper and middle segments and PD were higher in the DGF group than in the normal group. ROC curve analysis revealed that RI + PD was the index that best correlated with DGF (cutoff = 0.84). In the high RI + PD group, time to renal function recovery (6.33 +/- A 6.5 days) and number of dialysis sessions (2.81 +/- A 2.8) were greater than in the low RI + PD group (2.11 +/- A 5.3 days and 0.69 +/- A 1.5 sessions, respectively), p = 0.0001. Multivariate analysis showed that high donor final creatinine with a relative risk (RR) of 19.7 (2.01-184.7, p = 0.009) and older donor age (RR = 1.17 (1.04-1.32), p = 0.007) correlated with risk DGF.Quantified PD (RI + PD) was the best DGF predictor. PD quantification has not been previously reported .
Resumo:
Background: The main manifestation of hyperglycaemia during pregnancy is gestational diabetes mellitus. It can herald diabetes mellitus type 2 and its deleterious long-term effects, such as hypertension and cardiovascular disease. The aim of this study was to assess diastolic function in women with gestational diabetes mellitus, one of the first signs of future cardiovascular disease.Methods: A total of 21 women with gestational diabetes mellitus and 23 healthy pregnant women (control group) between 34 and 37weeks of gestation underwent echocardiographic assessment. The diagnosis of gestational diabetes mellitus was made in agreement with the American Diabetes Association criteria. Echocardiographic images obtained were analysed according to the criteria of the American Society of Echocardiography. Data were analysed using Pearson correlation coefficient, analysis of variance and Student's t-test.Results: Women with gestational diabetes mellitus had higher posterior wall and interventricular septum thickness, increased left ventricular mass and left ventricular mass index, lower early diastolic annular velocity and early diastolic annular velocity/late diastolic annular velocity ratio. There was a positive correlation between left ventricular mass index and fasting glucose and pregnancy body mass index.Conclusion: Patients with gestational diabetes mellitus seem to have a different diastolic profile as well as a mildly dysfunctional pattern on echocardiogram, which may show a need for greater glycaemic control.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Obesity is a risk factor in the development of several respiratory diseases. Lung volumes tend to be decreased, especially expiratory reserve volume, increasing expiratory flow limitation during tidal breathing. Barometric whole-body plethysmography is a non-invasive pulmonary function test that allows a dynamic study of breathing patterns. The objective of this study was to compare pulmonary function variables between obese and non-obese cats through the use of barometric whole-body plethysmography. Nine normal-weight and six obese cats were placed in the plethysmograph chamber, and different respiratory variables were measured. There was a significant decrease in tidal volume per kilogram (P=0.003), minute volume per kilogram (P=0.001) and peak inspiratory and expiratory flows per kilogram (P=0.001) in obese cats compared with non-obese cats. Obesity failed to demonstrate a significant increase in bronchoconstriction index variable enhanced pause (Penh), as previously reported in humans and dogs. The results show that feline obesity impairs pulmonary function in cats, although a significant increase in bronchoconstriction indexes was not observed. Non-invasive barometric whole-body plethysmography can help characterise mechanical dysfunction of the airways in obese cats.
Resumo:
This paper presents two diagnostic methods for the online detection of broken bars in induction motors with squirrel-cage type rotors. The wavelet representation of a function is a new technique. Wavelet transform of a function is the improved version of Fourier transform. Fourier transform is a powerful tool for analyzing the components of a stationary signal. But it is failed for analyzing the non-stationary signal whereas wavelet transform allows the components of a non-stationary signal to be analyzed. In this paper, our main goal is to find out the advantages of wavelet transform compared to Fourier transform in rotor failure diagnosis of induction motors.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
The aims of this study were to evaluate the isoflurane sparing and clinical effects of a constant rate infusion of morphine - lidocaine - ketamine (MLK) in healthy sheep undergoing experimental gastrointestinal surgery. Twelve adult female sheep (Texel breed) were used, weighing 36.5 +/- 8.1 kg. The sheep were anesthetized for the implantation of duodenal cannulas. The sheep were premedicated with 0.3 mg kg(-1) intramuscular (IM) morphine and 20 mu g kg(-1) intravenous (IV) detomidine. After premedication, anesthesia was induced using 5 mg kg(-1) ketamine and 0.5 mg kg(-1) diazepam IV and maintained using isoflurane in 100% oxygen. After the induction of anesthesia, the animals were allocated into two groups (each n=6); the GMLK (MLK group - 10 mg morphine, 150 mg lidocaine, 30 mg de ketamine were added in 500 mL saline) received a 10 mL kg(-1)h(-1) MLK infusion during the maintenance of anesthesia, and GCON (control group) received 10 mL kg(-1)h(-1) of 0.9% sodium chloride. The animals were mechanically ventilated. Cardiopulmonary variables and end-tidal isoflurane concentration (FE'Iso) were measured at baseline (immediately before the surgery) and 15, 30 and 45 minutes after initiation of surgery. In GMLK, there was a decrease in the FE 'Iso at 15, 30 and 45 minutes, a reduction of up to 75.6% during the surgery. The HR was lower in GMLK compared with GCON at 30 minutes, and the MAP was at during baseline in GCON compared with GMLK. The standing time was less in GMLK than in GCON. The use of intravenous MLK was demonstrated to offer great efficiency as part of a balanced anesthesia protocol in sheep, with a 75.6% reduction in the need for isoflurane, providing stability of the cardiovascular parameters and blood gases with a shortened recovery period.
Resumo:
A radial basis function network (RBFN) circuit for function approximation is presented. Simulation and experimental results show that the network has good approximation capabilities. The RBFN was a squared hyperbolic secant with three adjustable parameters amplitude, width and center. To test the network a sinusoidal and sine function,vas approximated.
Resumo:
The Bi-Sr-Ca-Cu-O system has been one of the most studied superconducting ceramic materials for industry applications. The most of the studies with this aim are on silver/ceramic composites, due to the benefits and great compatibility of this metal with the oxide. In this paper we describe a systematic and comparative study on Ag/BSCCO composite, made by the citrate route, in which the ceramic pellets are sintered in the presence of silver powder using several proportions and having several granulations. It was observed that the introduction of fine (0.5 and 2 μm) silver powder in the proportions of 5 wt. % always implies in a better critical current density compared to the no silver pellet. According to the results, the silver powder in excess of 5 wt.% may not promote best electrical properties, depending on the size of the silver particles.