907 resultados para Gait speed
Resumo:
Objective: This study aimed to analyze and compare the role of a water-based exercise program versus a combination of water and callisthenic exercises on postural control, functional independence, and freezing of gait (FOG) in patients with mild to moderate Parkinson disease.Methods: Twenty-five community-dwelling participants with idiopathic Parkinson disease were recruited. Of these, 9 participants took part in a water-based program of physical exercises and the other 16 participants took part in a combined program that consisted of callisthenic exercises plus an aquatic exercise session. Both programs were 16 weeks in duration. The clinical evaluation assessed the festination by means of the FOG score test; postural control was verified by means of the balance test of the short physical performance battery, and the Spanish validated version of the Unified Parkinson's Disease Rating Scale part 2 was used to assess functional independence. Participants were evaluated before and after 16 weeks of both proposed programs.Results: The results showed improvement in FOG for both groups, although a significant main effect was observed only in the patients who performed the callisthenic exercise plus an aquatic exercise program. Postural control did not show significant improvements after both proposed physical exercise programs as soon as functional autonomy. Our preliminary results suggest that training sessions with the combination of water plus callisthenic exercises may be a useful physical rehabilitation strategy for individuals with mild to moderate Parkinson disease who have FOG.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
This pilot study aimed to identify the effects of a 6-month, multimodal exercise program on clinical and gait parameters in patients with Parkinson's disease. Two groups of participants were enrolled in the study: Trained Group (TG) and Control Group (CG). Individuals in the TG exercised three times a week for 24 weeks (in a multimodal exercise program), while the CG participants maintained their regular activity level. Participants in both the TG and the CG were assessed at pre- and posttest by clinical rates and the spatiotemporal parameters of self-paced walking. The two groups were not significantly different in demographic, clinical, and gait data at baseline. There were no significant differences between groups for clinical data at posttest. The purposed multimodal exercise program has found improvement in some kinematic gait parameters for the TG. Further study in the form of randomized controlled trial would be required to establish effectiveness of the intervention.
Resumo:
This report describes the use of a pressure-sensitive walkway to evaluate an uncommon case of a cat with dorsal luxation of the left scapula and an amputated right forelimb. The findings suggest that limb amputation induced load redistribution mostly to the contralateral forelimb despite the scapular luxation.
Resumo:
To assess whether serum vitamin D concentration is associated with gait status and mortality among patients with fractures of the proximal femur, six months after suffering the fracture. Consecutive patients aged ≥65 years with fractures of the proximal femur, who were admitted to the orthopedics and traumatology ward of our service between January and December 2011, were prospectively evaluated. Clinical, radiological, epidemiological and laboratory analyses were performed, including vitamin D. The patients underwent surgery and were followed up as outpatients, with return visits 15, 30, 60 and 180 days after discharge, at which the outcomes of gait and mortality were evaluated. Eighty-eight patients were evaluated. Two of them were excluded because they presented oncological fractures. Thus, 86 patients of mean age 80.2 ± 7.3 years were studied. In relation to serum vitamin D, the mean was 27.8 ± 14.5 ng/mL, and 33.7% of the patients presented deficiency of this vitamin. In relation to gait, univariate and multivariate logistic regression showed that vitamin D deficiency was not associated with gait recovery, even after adjustment for gender, age and type of fracture (OR: 1.463; 95% CI: 0.524-4.088; p = 0.469). Regarding mortality, Cox regression analysis showed that vitamin D deficiency was not related to its occurrence within six months, even in multivariate analysis (HR: 0.627; 95% CI: 0.180-2.191; p = 0.465). Serum vitamin D concentration was not related to gait status and/or mortality among patients with fractures of the proximal femur, six months after suffering the fracture.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
The aim of this study was to investigate the effect of recovery time after quadriceps muscle fatigue on gait in young adults. Forty young adults (20-40 years old) performed three 8-m gait trials at preferred velocity before and after muscle fatigue, and after 5, 10 and 20min of passive rest. In addition, at each time point, two maximal isometric voluntary contractions were preformed. Muscle fatigue was induced by repeated sit-to-stand transfers until task failure. Spatio-temporal, kinetic and muscle activity parameters, measured in the central stride of each trial, were analyzed. Data were compared between before and after the muscle fatigue protocol and after the recovery periods by one-way repeated measures ANOVA. The voluntary force was decreased after the fatigue protocol (p<0.001) and after 5, 10 and 20min of recovery compared to before the fatigue protocol. Step width (p<0.001) and RMS of biceps femoris (p<0.05) were increased immediately after the fatigue protocol and remained increased after the recovery periods. In addition, stride duration was decreased immediately after the fatigue protocol compared to before and to after 10 and 20min of rest (p<0.001). The anterior-posterior propulsive impulse was also decreased after the fatigue protocol (p<0.001) and remained low after 5, 10 and 20min of rest. We conclude that 20min is not enough to see full recovery of gait after exhaustive quadriceps muscle fatigue.
Resumo:
O desempenho de tratores agrícolas em condições de campo resulta da interação entre pneu e rodado, influenciado pela velocidade de deslocamento. O objetivo deste trabalho foi avaliar o desempenho de um trator agrícola sob diferentes pressões de inflação dos pneus da semeadora (518, 483, and 414kPa) e em duas marchas que proporcionaram velocidades de 3,0 e 6,0km h-1. O experimento foi realizado no campus de Jaboticabal da Universidade Estadual Paulista (UNESP). O delineamento experimental utilizado foi fatorial inteiramente casualizado (3x2), com quatro repetições. A força de tração foi influenciada pela marcha e pela potência exigida; no entanto, a pressão de inflação do pneu da semeadora não alterou esses parâmetros. Além disso, o consumo de combustível foi influenciado apenas pela marcha do trator. O consumo de energia foi maior com o aumento da velocidade, ocasionada pela mudança de marcha. A velocidade de deslocamento foi maior para a pressão de 518kPa, em razão da menor patinagem da semeadora promovida por essa pressão. A patinagem do trator não foi alterada pelos fatores testados.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
This study examined the influence of different speed increments during treadmill exercise tests on peak treadmill speed (Vpeak) and its relationship with a 1-h treadmill running performance. 18 male recreational and amateur runners (10-km running pace: 10–15 km·h−1) performed, in an alternate order, 3 continuous incremental exercise tests with different speed increments (0.5, 1.0 and 2.0 km·h−1) on a motorized treadmill to determine Vpeak. Thereafter they undertook a 1-h time trial on a treadmill. Vpeak was determined as either (a) the highest speed that could be maintained for a complete minute (Vpeak-60 s), (b) the speed of the last complete stage (Vpeak-C), or (c) the speed of the last complete stage added to the product of the speed increment and the completed fraction of the incomplete stage (Vpeak-P). The Vpeak values were highly influenced by the different speed-incremented rates and the Vpeak-P determined during the protocol comprising speed increments of 1 km·h−1 presented the highest correlation with 1-h time trial performance (r=0.89). The results suggest that a protocol with speed increments comprising 1 km·h−1 and with a 3-min stage duration should be used as standard for the determination of Vpeak to assess aerobic fitness and predict endurance performance in recreational runners. Furthermore, the Vpeak-P should be used for the determination of Vpeak.
Resumo:
The adaptation of a commercially available ice machine for autonomous photovoltaic operation without batteries is presented. In this adaptation a 1040 W(p) photovoltaic array directly feeds a variable-speed drive and a 24 V(dc) source. The drive runs an induction motor coupled by belt-and-pulley to an open reciprocating compressor, while the dc source supplies a solenoid valve and the control electronics. Motor speed and refrigerant evaporation pressure are set aiming at continuously matching system power demand to photovoltaic power availability. The resulting system is a simple integration of robust, standard, readily available parts. It produces 27 kg of ice in a clear-sky day and has ice production costs around US$0.30/kg. Although a few machine features might be specific to Brazil, its technical and economical guidelines are applicable elsewhere. Copyright (C); 2010 John Wiley & Sons, Ltd.