747 resultados para Fiber optic sensor


Relevância:

30.00% 30.00%

Publicador:

Resumo:

In this study, the implementation of an optical accelerometer unit based on fiber Bragg gratings, suitable to monitor structures with frequencies up to 45 Hz, is reported. The developed optical system was used to estimate the structure eigenfrequencies of a steel footbridge, with a total length of 300 m, over the Sao Pedro Creek, located at University of Aveiro Campus, in Portugal. The acceleration records measured with this solution are compared with those obtained by traditional commercial electronic devices, revealing a root-mean-square error of 2.53 x 10(-5) G.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In this work physical and behavioral models for a bulk Reflective Semiconductor Optical Amplifier (RSOA) modulator in Radio over Fiber (RoF) links are proposed. The transmission performance of the RSOA modulator is predicted under broadband signal drive. At first, the simplified physical model for the RSOA modulator in RoF links is proposed, which is based on the rate equation and traveling-wave equations with several assumptions. The model is implemented with the Symbolically Defined Devices (SDD) in Advanced Design System (ADS) and validated with experimental results. Detailed analysis regarding optical gain, harmonic and intermodulation distortions, and transmission performance is performed. The distribution of the carrier and Amplified Spontaneous Emission (ASE) is also demonstrated. Behavioral modeling of the RSOA modulator is to enable us to investigate the nonlinear distortion of the RSOA modulator from another perspective in system level. The Amplitude-to-Amplitude Conversion (AM-AM) and Amplitude-to-Phase Conversion (AM-PM) distortions of the RSOA modulator are demonstrated based on an Artificial Neural Network (ANN) and a generalized polynomial model. Another behavioral model based on Xparameters was obtained from the physical model. Compensation of the nonlinearity of the RSOA modulator is carried out based on a memory polynomial model. The nonlinear distortion of the RSOA modulator is reduced successfully. The improvement of the 3rd order intermodulation distortion is up to 17 dB. The Error Vector Magnitude (EVM) is improved from 6.1% to 2.0%. In the last part of this work, the performance of Fibre Optic Networks for Distributed and Extendible Heterogeneous Radio Architectures and Service Provisioning (FUTON) systems, which is the four-channel virtual Multiple Input Multiple Output (MIMO), is predicted by using the developed physical model. Based on Subcarrier Multiplexing (SCM) techniques, four-channel signals with 100 MHz bandwidth per channel are generated and used to drive the RSOA modulator. The transmission performance of the RSOA modulator under the broadband multi channels is depicted with the figure of merit, EVM under di erent adrature Amplitude Modulation (QAM) level of 64 and 254 for various number of Orthogonal Frequency Division Multiplexing (OFDM) subcarriers of 64, 512, 1024 and 2048.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The concept that optic nerve fiber loss might be reduced by neuroprotection arose in the mid 1990s. The subsequent research effort, focused mainly on rodent models, has not yet transformed into a successful clinical trial, but provides mechanistic understanding of retinal ganglion cell death and points to potential therapeutic strategies. This review highlights advances made over the last year. In excitotoxicity and axotomy models retinal ganglion cell death has been shown to result from a complex interaction between retinal neurons and Müller glia, which release toxic molecules including tumor necrosis factor alpha. This counteracts neuroprotection by neurotrophins such as nerve growth factor, which bind to p75NTR receptors on Müller glia stimulating the toxic release. Another negative effect against neurotrophin-mediated protection involves the action of LINGO-1 at trkB brain-derived neurotrophic factor (BDNF) receptors, and BDNF neuroprotection is enhanced by an antagonist to LINGO-1. As an alternative to pharmacotherapy, retinal defences can be stimulated by exposure to infrared radiation. The mechanisms involved in glaucoma and other optic nerve disorders are being clarified in rodent models, focusing on retrograde degeneration following axonal damage, excitotoxicity and inflammatory/autoimmune mechanisms. Neuroprotective strategies are being refined in the light of the mechanistic understanding.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Thèse numérisée par la Division de la gestion de documents et des archives de l'Université de Montréal.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Optical fiber based laser induced fluorescence (LIF) measurements were carried out using Rhodamine B to analyze two different species of bacteria , a Gram-positive bacteria namely Bacillus smithii , and fibrin alginolvticus, a Gram- negative bacteria . The fiber sensor was clearly able to distinguish between the two species of bacteria . Quenching effect of the dye Rhodamine B by Bacillus smithii was observed . The effect of dye on the samples was also studied in detail.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Optical fiber based laser induced fluorescence (LIF) measurements were carried out using Rhodamine B to analyze two different species of bacteria , a Gram-positive bacteria namely Bacillus .cmithii , and fibrin alginolvticus, a Gram-' negative bacteria . The fiber sensor was clearly able to distinguish between the two species of bacteria . Quenching effect of the dye Rhodamine B by Bacillus smitltii was observed . The effect of dye on the samples was also studied in detail.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

At present, a fraction of 0.1 - 0.2% of the patients undergoing surgery become aware during the process. The situation is referred to as anesthesia awareness and is obviously very traumatic for the person experiencing it. The reason for its occurrence is mostly an insufficient dosage of the narcotic Propofol combined with the incapability of the technology monitoring the depth of the patient’s anesthetic state to notice the patient becoming aware. A solution can be a highly sensitive and selective real time monitoring device for Propofol based on optical absorption spectroscopy. Its working principle has been postulated by Prof. Dr. habil. H. Hillmer and formulated in DE10 2004 037 519 B4, filed on Aug 30th, 2004. It consists of the exploitation of Intra Cavity Absorption effects in a two mode laser system. In this Dissertation, a two mode external cavity semiconductor laser, which has been developed previously to this work is enhanced and optimized to a functional sensor. Enhancements include the implementation of variable couplers into the system and the implementation of a collimator arrangement into which samples can be introduced. A sample holder and cells are developed and characterized with a focus on compatibility with the measurement approach. Further optimization concerns the overall performance of the system: scattering sources are reduced by re-splicing all fiber-to-fiber connections, parasitic cavities are eliminated by suppressing the Fresnel reflexes of all one fiber ends by means of optical isolators and wavelength stability of the system is improved by the implementation of thermal insulation to the Fiber Bragg Gratings (FBG). The final laser sensor is characterized in detail thermally and optically. Two separate modes are obtained at 1542.0 and 1542.5 nm, tunable in a range of 1nm each. Mode Full Width at Half Maximum (FWHM) is 0.06nm and Signal to Noise Ratio (SNR) is as high as 55 dB. Independent of tuning the two modes of the system can always be equalized in intensity, which is important as the delicacy of the intensity equilibrium is one of the main sensitivity enhancing effects formulated in DE10 2004 037 519 B4. For the proof of concept (POC) measurements the target substance Propofol is diluted in the solvents Acetone and DiChloroMethane (DCM), which have been investigated for compatibility with Propofol beforehand. Eight measurement series (two solvents, two cell lengths and two different mode spacings) are taken, which draw a uniform picture: mode intensity ratio responds linearly to an increase of Propofol in all cases. The slope of the linear response indicates the sensitivity of the system. The eight series are split up into two groups: measurements taken in long cells and measurements taken in short cells.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective: The objective of this study is to conduct a description of the features of optic neuropathy associated with Human Immunodeficiency Virus in relation to their possible incidence within our population, regarding that there is no data in our population in terms of frequency of this pathology (1,2). Methodology: Descriptive cross-sectional study of a clinical series of patients infected with human immunodeficiency virus, but AIDS, and the thickness of optic nerve´s layer of fibers studied with OCT technology (optical coherence tomography), patients were cited once captured. OCT was performed by the same observer, by taking 3 shots and picking the one with better reliability. Patients were given personally to the Ophthalmologic Foundation of Santander to conduct the review called OCT (optical coherence tomography). Results: In terms of viral load variable, we found a clear correlation in which validates the hypothesis that lower viral load means a thicker layer of fibers finding statistically significant differences for the 6 hours in right eye and 12 and 6 hours in left eye. Comparison between the known nomogram of fiber layer thickness for the population of Bucaramanga, Santander and thickness found in our sample, we note a clear decrease in the upper and lower quadrants, specifically in 7 hours and 11 hours, being more important in 7 hours, showing statistically significant differences. Conclusions: The pattern  of thinning of the nerve fiber layer in HIV positive patients without AIDS, and antiretroviral treatment type HAART, showed a statistically significant thinning targeted at 7 hours and 11 hours, being higher in first. Viral load figures have a direct relation with loss fiber layer, showing a statistically significant difference for the 6 and 12 hours.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A radiometric analysis of the light coupled by optical fiber amplitude modulating extrinsic-type reflectance displacement sensors is presented. Uncut fiber sensors show the largest range but a smaller responsivity. Single cut fiber sensors exhibit an improvement in responsivity at the expense of range. A further increase in responsivity as well as a reduction in the operational range is obtained when the double cut sensor configuration is implemented. The double cut configuration is particularly suitable in applications where feedback action is applied to the moving reflector surface. © 2000 American Institute of Physics.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper describes an automated trimming system of large glass fiber reinforced plastic (GFRP) using an omni-directional wheeled mobile robot (WMR) and its path control method. In trimming GFRP parts, much glass fiber and plastic powder dust occur and it becomes bad visible in environment. It is necessary to correct dead-reckoning errors of the WMR in order to control its moving path. We have discussed an external correction method of the dead-reckoning errors for the WMR using ultrasonic sensor.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose. The authors compared the visual gaze behaviors of glaucoma subspecialists with those of ophthalmology trainees during optic disc and retinal nerve fiber layer (RNFL) examination.

Methods. Seven glaucoma subspecialists and 23 ophthalmology trainees participated in the project. Participants were shown eight glaucomatous optic disc images with varied morphology. Eye movements during examination of the optic disc photographs were tracked. For each disc image, graders were asked to assign a presumptive diagnosis for probability of glaucoma. There was no time restriction.

Results. Overall, trainees spent more time looking at disc images than glaucoma subspecialists (21.3 [13.9–37.7] vs. 16.6 [12.7–19.7]) seconds; median [interquartile range (IQR)], respectively; P < 0.01) and had no systematic patterns of gaze behavior, and gaze behavior was unaltered by disc morphology or topographic cues of pathology. Experienced viewers demonstrated more systematic and ordered gaze behavior patterns and spent longer times observing areas with the greatest likelihood of pathology (superior and inferior poles of the optic nerve head and adjacent RNFL) compared with the trainees. For discs with focal pathology, the proportion of total time spent examining definite areas of pathology was 28.9% (22.4%–33.6%) for glaucoma subspecialists and 13.5% (12.2%–19.2%) for trainees (median [IQR]; P < 0.05). Furthermore, experts adapted their viewing habits according to disc morphology.

Conclusions. Glaucoma subspecialists adopt systematic gaze behavior when examining the optic nerve and RNFL, whereas trainees do not. It remains to be elucidated whether incorporating systematic viewing behavior of the optic disc and RNFL into teaching programs for trainees may expedite their acquisition of accurate and efficient glaucoma diagnosis skills.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In this work, optical sensing performance of tapered multimode fiber tip coated with graphene oxide (GO) nanostructured thin film towards aqueous ethanol with different concentrations is investigated. The tapering process of the optical fiber is done by a glass processing machine. The multimode optical fiber tip is dip-coated with GO and annealed at 70 °C to enhance the binding of the nanomaterials to the silica fiber. FESEM, Raman microscopy and XRD analyses are performed to micro-characterize the GO thin films. The morphology of the GO is observed to be in sheets forms. The reflectance response of the GO coated fiber tip is compared with the uncoated tip. The measurements are taken using a spectrophotometer in the optical wavelength range of 550-720 nm. The reflectance response of the GO coated fiber tip reduced proportionally, upon exposure to ethanol with concentration range of 5-80%. The dynamic response of the developed sensor showed strong reversibility and repeatability when it is exposed to ethanol with concentrations of 5%, 20% and 40% in distilled water. At room temperature, the sensor shows fast response and recovery as low as 19 and 25 s, respectively. © 2014 Elsevier B.V.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A scaled-up fiber wet-spinning production of electrically conductive and highly stretchable PU/PEDOT:PSS fibers is demonstrated for the first time. The PU/PEDOT:PSS fibers possess the mechanical properties appropriate for knitting various textile structures. The knitted textiles exhibit strain sensing properties that were dependent upon the number of PU/PEDOT:PSS fibers used in knitting. The knitted textiles show sensitivity (as measured by the gauge factor) that increases with the number of PU/PEDOT:PSS fibers deployed. A highly stable sensor response was observed when four PU/PEDOT:PSS fibers were co-knitted with a commercial Spandex yarn. The knitted textile sensor can distinguish different magnitudes of applied strain with cyclically repeatable sensor responses at applied strains of up to 160%. When used in conjunction with a commercial wireless transmitter, the knitted textile responded well to the magnitude of bending deformations, demonstrating potential for remote strain sensing applications. The feasibility of an all-polymeric knitted textile wearable strain sensor was demonstrated in a knee sleeve prototype with application in personal training and rehabilitation following injury.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Security of Wireless Sensor Network (WSN) is a key issue in information security. Most existing security protocols exploit various Mathematical tools to strengthen their security. Some protocols use the details of the geographical location of the nodes. However, to the best authors’ knowledge, none of the existing works exploit the constraints faced by the adversary, specifically, tracing a particular frequency from a large range of unknown frequency channels. The current work uses positional details of the individual nodes. Then the aim is to exploit this weakness of tracing frequencies by assigning a wide range of frequency channels to each node. Experiments using Magneto Optic Sensors reveal that any change of the parametric Faraday’s rotational angle affects the frequency of the Optical waves. This idea can perhaps be generalized for practically deployable sensors (having respective parameters) along with a suitable key management scheme.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

To describe retinal nerve fiber layer changes in late-stage diffuse unilateral subacute neuroretinitis eyes and compare these results with healthy eyes observed through nerve fiber analyzer (GDx®). Methods: This is a retrospective case-control study in which 49 eyes in late-stage diffuse unilateral subacute neuroretinitis were examined from May/97 to December/ 01. First, eyes with diffuse unilateral subacute neuroretinitis and healthy contralateral eyes (Control Group I) were statistically matched. Subsequently, eyes with diffuse unilateral subacute neuroretinitis were compared with eyes of healthy patients (Control Group II). Results: Eyes from Control Groups I and II had higher relative frequency of “within normal limits” status. Eyes from the diffuse unilateral subacute neuroretinitis (DUSN) Group had higher frequency of “outside normal limits” and “borderline” status. Control Groups I and II had absolute values different from the DUSN Group regarding all parameters (p<0.05), except for Symmetry in Control Groups I and II, Average thickness and Superior Integral in control group II. Conclusion: Patients with late-stage diffuse unilateral subacute neuroretinitis presented presumed decrease in nerve fiber layer thickness shown by GDx®. Retinal zones with larger vascular support and larger amount of nerve fibers presented higher decrease in the delay of the reflected light measured by the nerve fiber analyzer