996 resultados para Endodontics - Instrumentation
Resumo:
Due to the importance and wide applications of the DNA analysis, there is a need to make genetic analysis more available and more affordable. As such, the aim of this PhD thesis is to optimize a colorimetric DNA biosensor based on gold nanoprobes developed in CEMOP by reducing its price and the needed volume of solution without compromising the device sensitivity and reliability, towards the point of care use. Firstly, the price of the biosensor was decreased by replacing the silicon photodetector by a low cost, solution processed TiO2 photodetector. To further reduce the photodetector price, a novel fabrication method was developed: a cost-effective inkjet printing technology that enabled to increase TiO2 surface area. Secondly, the DNA biosensor was optimized by means of microfluidics that offer advantages of miniaturization, much lower sample/reagents consumption, enhanced system performance and functionality by integrating different components. In the developed microfluidic platform, the optical path length was extended by detecting along the channel and the light was transmitted by optical fibres enabling to guide the light very close to the analysed solution. Microfluidic chip of high aspect ratio (~13), smooth and nearly vertical sidewalls was fabricated in PDMS using a SU-8 mould for patterning. The platform coupled to the gold nanoprobe assay enabled detection of Mycobacterium tuberculosis using 3 8l on DNA solution, i.e. 20 times less than in the previous state-of-the-art. Subsequently, the bio-microfluidic platform was optimized in terms of cost, electrical signal processing and sensitivity to colour variation, yielding 160% improvement of colorimetric AuNPs analysis. Planar microlenses were incorporated to converge light into the sample and then to the output fibre core increasing 6 times the signal-to-losses ratio. The optimized platform enabled detection of single nucleotide polymorphism related with obesity risk (FTO) using target DNA concentration below the limit of detection of the conventionally used microplate reader (i.e. 15 ng/μl) with 10 times lower solution volume (3 μl). The combination of the unique optical properties of gold nanoprobes with microfluidic platform resulted in sensitive and accurate sensor for single nucleotide polymorphism detection operating using small volumes of solutions and without the need for substrate functionalization or sophisticated instrumentation. Simultaneously, to enable on chip reagents mixing, a PDMS micromixer was developed and optimized for the highest efficiency, low pressure drop and short mixing length. The optimized device shows 80% of mixing efficiency at Re = 0.1 in 2.5 mm long mixer with the pressure drop of 6 Pa, satisfying requirements for the application in the microfluidic platform for DNA analysis.
Resumo:
This paper presents the findings of an experimental campaign that was conducted to investigate the seismic behaviour of log houses. A two-storey log house designed by the Portuguese company Rusticasa® was subjected to a series of shaking table tests at LNEC, Lisbon, Portugal. The paper contains the description of the geometry and construction of the house and all the aspects related to the testing procedure, namely the pre-design, the setup, instrumentation and the testing process itself. The shaking table tests were carried out with a scaled spectrum of the Montenegro (1979) earthquake, at increasing levels of PGA, starting from 0.07g, moving on to 0.28g and finally 0.5g. The log house did not suffer any major damage and remained in working condition throughout the entire process. The preliminary analysis of the overall behaviour of the log house is also discussed.
Resumo:
Our objective was to validate a new device dedicated to measure the light disturbances surrounding bright sources of light under different sources of potential variability. Twenty subjects were involved in the study. Light distortion was measured using an experimental prototype (light distortion analyzer, CEORLab, University of Minho, Portugal) comprising twenty-four LED arrays panel at 2 m. Sources of variability included: intrasession and intersession repeated measures, pupil size (3 versus 6 mm), defocus (þ0.50) correction for the working distance, angular resolution (15 deg versus 30 deg), temporal stimuli presentation, and pupil size. Size, shape, location, and irregularity parameters have been obtained. At a low speed of presentation of the stimuli, changes in angular resolution did not have an effect on the results of the parameters measured. Results did not change with pupil size. Intensity of the central glare source significantly influenced the outcomes. Examination time was reduced by 30% when a 30 deg angular resolution was explored instead of 15 deg. Measurements were fast and repeatable under the same experimental conditions. Size and shape parameters showed the highest consistency, whereas location and irregularity parameters showed lower consistency. The system was sensitive to changes in the intensity of the central glare source but not to pupil changes in this sample of healthy subjects.
Resumo:
The research of stereotactic apparatus to guide surgical devices began in 1908, yet a major part of today's stereotactic neurosurgeries still rely on stereotactic frames developed almost half a century ago. Robots excel at handling spatial information, and are, thus, obvious candidates in the guidance of instrumentation along precisely planned trajectories. In this review, we introduce the concept of stereotaxy and describe a standard stereotactic neurosurgery. Neurosurgeons' expectations and demands regarding the role of robots as assistive tools are also addressed. We list the most successful robotic systems developed specifically for or capable of executing stereotactic neurosurgery. A critical review is presented for each robotic system, emphasizing the differences between them and detailing positive features and drawbacks. An analysis of the listed robotic system features is also undertaken, in the context of robotic application in stereotactic neurosurgery. Finally, we discuss the current perspective, and future directions of a robotic technology in this field. All robotic systems follow a very similar and structured workflow despite the technical differences that set them apart. No system unequivocally stands out as an absolute best. The trend of technological progress is pointing toward the development of miniaturized cost-effective solutions with more intuitive interfaces.
Resumo:
Dissertação de mestrado integrado em Engenharia Biomédica (área de especialização em Eletrónica Médica)
Resumo:
Dissertação de mestrado integrado em Engenharia Eletrónica Industrial e Computadores
Resumo:
Dissertação de mestrado integrado em Engenharia Eletrónica Industrial e Computadores
Resumo:
This paper describes the concept, technical realisation and validation of a largely data-driven method to model events with Z→ττ decays. In Z→μμ events selected from proton-proton collision data recorded at s√=8 TeV with the ATLAS experiment at the LHC in 2012, the Z decay muons are replaced by τ leptons from simulated Z→ττ decays at the level of reconstructed tracks and calorimeter cells. The τ lepton kinematics are derived from the kinematics of the original muons. Thus, only the well-understood decays of the Z boson and τ leptons as well as the detector response to the τ decay products are obtained from simulation. All other aspects of the event, such as the Z boson and jet kinematics as well as effects from multiple interactions, are given by the actual data. This so-called τ-embedding method is particularly relevant for Higgs boson searches and analyses in ττ final states, where Z→ττ decays constitute a large irreducible background that cannot be obtained directly from data control samples.
Resumo:
CRSLS MIS Case Reports from SLS.org.
Resumo:
OBJETIVO: Avaliar o monitor OMRON 705-CP de medida de pressão arterial em adolescentes e adultos jovens. MÉTODOS: De acordo com o protocolo da British Hypertension Society e da Association for the Advancement of Medical Instrumentation, realizamos a validação do aparelho em 60 adolescentes. O monitor foi conectado em Y com a coluna de mercúrio e foram realizadas 4 medidas consecutivas e simultâneas, analisadas as independentes e calculadas as diferenças médias entre as pressões e o desvio padrão dessas diferenças. Os resultados foram analisados de acordo com o sistema de grau do protocolo utilizado. RESULTADOS: Foram avaliadas 240 medidas. A idade média dos pacientes foi 16,3 anos. Quando comparada a medida realizada pela coluna de mercúrio com o aparelho houve uma diferença < 15 mmHg em 97,9% das medidas sistólicas e 98,8% das diastólicas; uma diferença < 10 mmHg em 86,3% das medidas sistólicas e 90,4% das diastólicas, classificada como grau A; uma diferença < 5 mmHg em 59,1% das medidas sistólicas e 67% das medidas diastólicas, considerada pela classificação entre A/B. A diferença média e o desvio padrão dessa diferença na pressão sistólica foi de 2,91±6,42 mmHg e para a diastólica de 1,16±5,79 mmHg. CONCLUSÃO: O monitor OMRON 705-CP mostrou-se válido para medidas de pressão arterial de adolescentes segundo o protocolo empregado.
Resumo:
This is a study of a state of the art implementation of a new computer integrated testing (CIT) facility within a company that designs and manufactures transport refrigeration systems. The aim was to use state of the art hardware, software and planning procedures in the design and implementation of three CIT systems. Typical CIT system components include data acquisition (DAQ) equipment, application and analysis software, communication devices, computer-based instrumentation and computer technology. It is shown that the introduction of computer technology into the area of testing can have a major effect on such issues as efficiency, flexibility, data accuracy, test quality, data integrity and much more. Findings reaffirm how the overall area of computer integration continues to benefit any organisation, but with more recent advances in computer technology, communication methods and software capabilities, less expensive more sophisticated test solutions are now possible. This allows more organisations to benefit from the many advantages associated with CIT. Examples of computer integration test set-ups and the benefits associated with computer integration have been discussed.
Resumo:
FUNDAMENTO: O hipotireoidismo manifesto está associado com elevação da pressão arterial diastólica; entretanto, a associação entre o hipotireoidismo subclínico (HS) e alteração da pressão arterial (PA) é desconhecida. OBJETIVO: O objetivo do presente estudo foi avaliar a monitorização ambulatorial da pressão arterial (MAPA) por 24 horas em pacientes normotensos com HS em comparação a indivíduos normotensos eutireóideos (EU). MÉTODOS: Foi realizado um estudo transversal com 50 participantes (HS = 30 e EU = 20) que não apresentavam diferenças em relação a fatores de risco para hipertensão. A monitorização ambulatorial de pressão arterial foi realizada com um monitor Dynamapa®, utilizando-se um método oscilométrico validado pela AAMI (Association for the Advancement of Medical Instrumentation) e pela BHS (British Hypertension Society). RESULTADOS: Os níveis séricos médios de TSH e T4 livre foram respectivamente 6,9 ± 2,2 µUI/ml e 1,1 ± 0,2 ng/dl em pacientes com HS. Apesar de não haver diferença em relação à média da pressão arterial sistólica e diastólica entre os dois grupos, houve uma correlação positiva entre os níveis de pressão arterial diastólica média (PADM) e os valores séricos de TSH em pacientes com HS (r:0,477; p = 0,004). Essa correlação foi detectada por medidas diurnas (r:0,498; p = 0,002) e noturnas (r:0,322; p = 0,032). CONCLUSÃO: A pressão arterial não diferiu entre pacientes com ou sem HS; contudo, os resultados sugerem que a progressão de hipotireoidismo subclínico para níveis mais elevados de TSH pode aumentar o risco cardiovascular através do aumento da pressão arterial diastólica.
Resumo:
The purpose of this paper is twofold. First, we construct a DSGE model which spells out explicitly the instrumentation of monetary policy. The interest rate is determined every period depending on the supply and demand for reserves which in turn are affected by fundamental shocks: unforeseeable changes in cash withdrawal, autonomous factors, technology and government spending. Unexpected changes in the monetary conditions of the economy are interpreted as monetary shocks. We show that these monetary shocks have the usual effects on economic activity without the need of imposing additional frictions as limited participation in asset markets or sticky prices. Second, we show that this view of monetary policy may have important consequences for empirical research. In the model, the contemporaneous correlations between interest rates, prices and output are due to the simultaneous effect of all fundamental shocks. We provide an example where these contemporaneous correlations may be misinterpreted as a Taylor rule. In addition, we use the sign of the impact responses of all shocks on output, prices and interest rates derived from the model to identify the sources of shocks in the data.
Resumo:
The PulseCath iVAC 3L? left ventricular assist device is an option to treat transitory left heart failure or dysfunction post-cardiac surgery. Assisted blood flow should reach up to 3 l/min. In the present in vitro model exact pump flow, depending on various frequencies and afterload was examined. Optimal flow was achieved with inflation/deflation frequencies of about 70-80/min. The maximal flow rate was achieved at about 2.5 l/min with a minimal afterload of 22 mmHg. Handling of the device was easy due to the connection to a standard intra-aortic balloon pump console. With increasing afterload (up to a simulated mean systemic pressure of 66 mmHg) flow rate and cardiac support are in some extent limited.