888 resultados para Edge detection method


Relevância:

30.00% 30.00%

Publicador:

Resumo:

A solution of (18)F was standardised with a 4pibeta-4pigamma coincidence counting system in which the beta detector is a one-inch diameter cylindrical UPS89 plastic scintillator, positioned at the bottom of a well-type 5''x5'' NaI(Tl) gamma-ray detector. Almost full detection efficiency-which was varied downwards electronically-was achieved in the beta-channel. Aliquots of this (18)F solution were also measured using 4pigamma NaI(Tl) integral counting and Monte Carlo calculated efficiencies as well as the CIEMAT-NIST method. Secondary measurements of the same solution were also performed with an IG11 ionisation chamber whose equivalent activity is traceable to the Système International de Référence through the contribution IRA-METAS made to it in 2001; IRA's degree of equivalence was found to be close to the key comparison reference value (KCRV). The (18)F activity predicted by this coincidence system agrees closely with the ionisation chamber measurement and is compatible within one standard deviation of the other primary measurements. This work demonstrates that our new coincidence system can standardise short-lived radionuclides used in nuclear medicine.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The objective of this study was to evaluate the prevalence and dissemination of human astroviruses (HAstV) in the environment by analyzing urban sewage samples from a wastewater treatment plant in the city of Rio de Janeiro, Brazil. A one-year study was performed with a total of 48 raw and treated sewage composite samples, which were collected biweekly from an activated sludge plant. Virus particles were concentrated by the adsorption-elution method using negatively charged membranes associated to a Centriprep Concentrator® 50 (Nihon Millipore). HAstV were detected in 16.7% of the samples in raw and treated sewage by using both qualitative and quantitative reverse transcriptase-polymerase chain reactions (RT-PCR and qPCR, respectively). Positive untreated sewage sample exhibited mean values of 1.1 x 10(4) gEq/mL. The qPCR sensitivity was 18 gEq/reaction. Through utilization of qPCR, a HAstV recovery efficiency of 4.2% and 4.3% was demonstrated for raw and treated sewage samples, respectively. The presence of HAstV in both the raw and treated sewage samples demonstrated the dissemination of these viruses in the environment as well as viral permanence after sewage treatment. There was a reduction in the total and faecal coliform levels, indicating efficiency of the wastewater treatment plant.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Water is a vehicle for disseminating human and veterinary toxoplasmosis due to oocyst contamination. Several outbreaks of toxoplasmosis throughout the world have been related to contaminated drinking water. We have developed a method for the detection of Toxoplasma gondii oocysts in water and we propose a strategy for the detection of multiple waterborne parasites, including Cryptosporidium spp. and Giardia. Water samples were filtered to recover Toxoplasma oocysts and, after the detection of Cryptosporidium oocysts and Giardia cysts by immunofluorescence, as recommended by French norm procedure NF T 90-455, the samples were purified on a sucrose density gradient. Detection of Toxoplasma was based on PCR amplification and mouse inoculation to determine the presence and infectivity of recovered oocysts. After experimental seeding assays, we determined that the PCR assay was more sensitive than the bioassay. This strategy was then applied to 482 environmental water samples collected since 2001. We detected Toxoplasma DNA in 37 environmental samples (7.7%), including public drinking water; however, none of them were positive by bioassay. This strategy efficiently detects Toxoplasma oocysts in water and may be suitable as a public health sentinel method. Alternative methods can be used in conjunction with this one to determine the infectivity of parasites that were detected by molecular methods.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Significant advances were made in the diagnosis of filariasis in the 1990s with the emergence of three new alternative tools: ultrasound and tests to detect circulating antigen using two monoclonal antibodies, Og4C3 and AD12-ICT-card. This study aimed to identify which of these methods is the most sensitive for diagnosis of infection. A total of 256 individuals, all male and carrying microfilariae (1-15,679 MF/mL), diagnosed by nocturnal venous blood samples, were tested by all three techniques. The tests for circulating filarial antigen concurred 100% and correctly identified 246/256 (96.69%) of the positive individuals, while ultrasound detected only 186/256 (73.44%). Of the circulating antigen tests, ICT-card was the most convenient method for identification of Wuchereria bancrofti carriers. It was easy to perform, practical and quick.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A new oligochromatographic assay, Speed-Oligo Novel Influenza A H1N1, was designed and optimized for the specific detection of the 2009 influenza A H1N1 virus. The assay is based on a PCR method coupled to detection of PCR products by means of a dipstick device. The target sequence is a 103-bp fragment within the hemagglutinin gene. The analytical sensitivity of the new assay was measured with serial dilutions of a plasmid that contained the target sequence, and we determined that down to one copy per reaction of the plasmid was reliably detected. Diagnostic performance was assessed with 103 RNAs from suspected cases (40 positive and 63 negative results) previously analyzed with a reference real-time PCR technique. All positive cases were confirmed, and no false-positive results were detected with the new assay. No cross-reactions were observed when other viral strains or clinical samples with other respiratory viruses were tested. According to these results, this new assay has 100% sensitivity and specificity. The turnaround time for the whole procedure was 140 min. The assay may be especially useful for the specific detection of 2009 H1N1 virus in laboratories not equipped with real-time PCR instruments

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A previously reported sensitive PCR assay for the detection of Schistosoma mansoni DNA was updated and evaluated. Changes in the DNA extraction method, including the use of a worldwide available commercial kit and the inclusion of additional quality control measures, increased the robustness of the test, as confirmed by the analysis of 67 faecal samples from an endemic area in Brazil. The PCR assay is at hand as a proven, reliable diagnostic test for the control of schistosomiasis in specific settings.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The aim of our study was to provide an innovative headspace-gas chromatography-mass spectrometry (HS-GC-MS) method applicable for the routine determination of blood CO concentration in forensic toxicology laboratories. The main drawback of the GC/MS methods discussed in literature for CO measurement is the absence of a specific CO internal standard necessary for performing quantification. Even if stable isotope of CO is commercially available in the gaseous state, it is essential to develop a safer method to limit the manipulation of gaseous CO and to precisely control the injected amount of CO for spiking and calibration. To avoid the manipulation of a stable isotope-labeled gas, we have chosen to generate in a vial in situ, an internal labeled standard gas ((13)CO) formed by the reaction of labeled formic acid formic acid (H(13)COOH) with sulfuric acid. As sulfuric acid can also be employed to liberate the CO reagent from whole blood, the procedure allows for the liberation of CO simultaneously with the generation of (13)CO. This method allows for precise measurement of blood CO concentrations from a small amount of blood (10 μL). Finally, this method was applied to measure the CO concentration of intoxicated human blood samples from autopsies.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

TCP flows from applications such as the web or ftp are well supported by a Guaranteed Minimum Throughput Service (GMTS), which provides a minimum network throughput to the flow and, if possible, an extra throughput. We propose a scheme for a GMTS using Admission Control (AC) that is able to provide different minimum throughput to different users and that is suitable for "standard" TCP flows. Moreover, we consider a multidomain scenario where the scheme is used in one of the domains, and we propose some mechanisms for the interconnection with neighbor domains. The whole scheme uses a small set of packet classes in a core-stateless network where each class has a different discarding priority in queues assigned to it. The AC method involves only edge nodes and uses a special probing packet flow (marked as the highest discarding priority class) that is sent continuously from ingress to egress through a path. The available throughput in the path is obtained at the egress using measurements of flow aggregates, and then it is sent back to the ingress. At the ingress each flow is detected using an implicit way and then it is admission controlled. If it is accepted, it receives the GMTS and its packets are marked as the lowest discarding priority classes; otherwise, it receives a best-effort service. The scheme is evaluated through simulation in a simple "bottleneck" topology using different traffic loads consisting of "standard" TCP flows that carry files of varying sizes

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The aim of this study was to apply a molecular protocol to detect leptospiral DNA in environmental water samples. The study was carried out in a peri-urban settlement in Petrópolis, state of Rio de Janeiro. A multiplex PCR method employing the primers LipL32 and 16SrRNA was used. Three out of 100 analysed samples were positive in the multiplex PCR, two were considered to have saprophytic leptospires and one had pathogenic leptospires. The results obtained supported the idea that multiplex PCR can be used to detect Leptospira spp in water samples. This method was also able to differentiate between saprophytic and pathogenic leptospires and was able to do so much more easily than conventional methodologies.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The introduction of newer molecular methods has led to the discovery of new respiratory viruses, such as human metapneumovirus (hMPV) and human bocavirus (hBoV), in respiratory tract specimens. We have studied the occurrence of hMPV and hBoV in the Porto Alegre (PA) metropolitan area, one of the southernmost cities of Brazil, evaluating children with suspected lower respiratory tract infection from May 2007-June 2008. A real-time polymerase chain reaction method was used for amplification and detection of hMPV and hBoV and to evaluate coinfections with respiratory syncytial virus (RSV), influenza A and B, parainfluenza 1, 2 and 3, human rhinovirus and human adenovirus. Of the 455 nasopharyngeal aspirates tested, hMPV was detected in 14.5% of samples and hBoV in 13.2%. A unique causative viral agent was identified in 46.2% samples and the coinfection rate was 43.7%. For hBoV, 98.3% of all positive samples were from patients with mixed infections. Similarly, 84.8% of all hMPV-positive results were also observed in mixed infections. Both hBoV and hMPV usually appeared with RSV. In summary, this is the first confirmation that hMPV and hBoV circulate in PA; this provides evidence of frequent involvement of both viruses in children with clinical signs of acute viral respiratory tract infection, although they mainly appeared as coinfection agents.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Direct smear examination using Ziehl-Neelsen staining for pulmonary tuberculosis (PTB) diagnosis is inexpensive and easy to use, but has the major limitation of low sensitivity. Rapid molecular methods are becoming more widely available in centralized laboratories, but they depend on timely reporting of results and strict quality assurance obtainable only from costly commercial kits available in high burden nations. This study describes a pre-commercial colorimetric method, Detect-TB, for detecting Mycobacterium tuberculosis DNA in which an oligonucleotide probe is fixed onto wells of microwell plates and hybridized with biotinylated polymerase chain reaction amplification products derived from clinical samples. The probe is capable of hybridising with the IS6110 insertion element and was used to specifically recognise the M. tuberculosis complex. When combined with an improved silica-based DNA extraction method, the sensitivity of the test was 50 colony-forming units of the M. tuberculosis reference strain H37Rv. The results that were in agreement with reference detection methods were observed in 95.2% (453/476) of samples included in the analysis. Sensitivity and specificity for 301 induced sputum samples and 175 spontaneous sputum samples were 85% and 98%, and 94% and 100%, respectively. This colorimetric method showed similar specificity to that described for commercially available kits and may provide an important contribution for PTB diagnosis.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Advances in clinical virology for detecting respiratory viruses have been focused on nucleic acids amplification techniques, which have converted in the reference method for the diagnosis of acute respiratory infections of viral aetiology. Improvements of current commercial molecular assays to reduce hands-on-time rely on two strategies, a stepwise automation (semi-automation) and the complete automation of the whole procedure. Contributions to the former strategy have been the use of automated nucleic acids extractors, multiplex PCR, real-time PCR and/or DNA arrays for detection of amplicons. Commercial fully-automated molecular systems are now available for the detection of respiratory viruses. Some of them could convert in point-of-care methods substituting antigen tests for detection of respiratory syncytial virus and influenza A and B viruses. This article describes laboratory methods for detection of respiratory viruses. A cost-effective and rational diagnostic algorithm is proposed, considering technical aspects of the available assays, infrastructure possibilities of each laboratory and clinic-epidemiologic factors of the infection.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This study compares the diagnostic accuracy of the TF-Test® (TFT) for human parasitosis with results obtained using the traditional Kato-Katz (KK), Hoffman-Pons-Janer (HPJ), Willis and Baermann-Moraes (BM) techniques. Overall, four stool samples were taken from each individual; three alternate-day TFT stool samples and another sample that was collected in a universal container. Stool samples were taken from 331 inhabitants of the community of Quilombola Santa Cruz. The gold standard (GS) for protozoa detection was defined as the combined results for TFT, HPJ and Willis coproscopic techniques; for helminth detection, GS was defined as the combined results for all five coproscopic techniques (TFT, KK, HPJ, Willis and BM). The positivity rate of each method was compared using the McNemar test. While the TFT exhibited similar positivity rates to the GS for Entamoeba histolytica/dispar (82.4%) and Giardia duodenalis (90%), HPJ and Willis techniques exhibited significantly lower positivity rates for these protozoa. All tests exhibited significantly lower positivity rates compared with GS for the diagnosis of helminths. The KK technique had the highest positivity rate for diagnosing Schistosoma mansoni (74.6%), while the TFT had the highest positivity rates for Ascaris lumbricoides (58.1%) and hookworm (75%); HPJ technique had the highest positivity rate for Strongyloides stercoralis (50%). Although a combination of tests is the most accurate method for the diagnosis of enteral parasites, the TFT reliably estimates the prevalence of protozoa and selected helminths, such as A. lumbricoides and hookworm. Further studies are needed to evaluate the detection accuracy of the TFT in samples with varying numbers of parasites.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In this study we compared two polymerase chain reaction (PCR) methods using either 16S ribosomal RNA (rRNA) or 23S rRNA gene primers for the detection of different Leptospira interrogans serovars. The performance of these two methods was assessed using DNA extracted from bovine tissues previously inoculated with several bacterial suspensions. PCR was performed on the same tissues before and after the formalin-fixed, paraffin-embedding procedure (FFPE tissues). The 23S rDNA PCR detected all fresh and FFPE positive tissues while the 16S rDNA-based protocol detected primarily the positive fresh tissues. Both methods are specific for pathogenic L. interrogans. The 23S-based PCR method successfully detected Leptospira in four dubious cases of human leptospirosis from archival tissue specimens and one leptospirosis-positive canine specimen. A sensitive method for leptospirosis identification in FFPE tissues would be a useful tool to screen histological specimen archives and gain a better assessment of human leptospirosis prevalence, especially in tropical countries, where large outbreaks can occur following the rainy season.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The aim of this study was to determine the occurrences of the group A rotavirus (RVA), norovirus (NoV) and human adenovirus (HAdV) in the surface waters of an urban lagoon (Rodrigo de Freitas Lagoon) in the city of Rio de Janeiro, Brazil. During one year of surveillance, water samples were obtained from the lagoon and other interconnected ecosystems (river and beach). The samples were concentrated using an adsorption-elution method with a negatively charged membrane and tested by qualitative and quantitative polymerase chain reaction assays. RVA was the most prevalent virus detected (24.3%) with a viral load ranging from 3.0 x 10¹-5.6 x 10(4) genome copies/L, followed by NoV (18.8%) and HAdV (16.7%). Considering water samples suitable for bathing, according to Escherichia coli criterion (< 2,000 most probable number/100 mL), viruses were detected in 50% (57/114) of them. Physicochemical parameters were also measured and showed possible correlations between turbidity and RVA presence and between pH and NoV presence. These data demonstrate the importance of considering viral parameters to ensure water quality and the utilisation of these parameters as additional tools for the characterisation of environmental contamination.