991 resultados para ELECTRIC-ARC TECHNIQUE
Resumo:
Geobiota are defined by taxic assemblages (i.e., biota) and their defining abiotic breaks, which are mapped in cross-section to reveal past and future biotic boundaries. We term this conceptual approach Temporal Geobiotic Mapping (TGM) and offer it as a conceptual approach for biogeography. TGM is based on geological cross-sectioning, which creates maps based on the distribution of biota and known abiotic factors that drive their distribution, such as climate, topography, soil chemistry and underlying geology. However, the availability of abiotic data is limited for many areas. Unlike other approaches, TGM can be used when there is minimal data available. In order to demonstrate TGM, we use the well-known area in the Blue Mountains, New South Wales (NSW), south-eastern Australia and show how surface processes such as weathering and erosion affect the future distribution of a Moist Basalt Forest taxic assemblage. Biotic areas are best represented visually as maps, which can show transgressions and regressions of biota and abiota over time. Using such maps, a biogeographer can directly compare animal and plant distributions with features in the abiotic environment and may identify significant geographical barriers or pathways that explain biotic distributions.
Resumo:
Totally extraperitoneal laparoscopic hernia repair is an efficient but technically demanding procedure. As mechanisms of hernia recurrence may be related to these technical difficulties, we have modified a previously described double-mesh technique in an effort to simplify the procedure. Extraperitoneal laparoscopic hernia repairs were performed in 82 male and 17 female patients having inguinal, femoral, and recurrent bilateral hernias. A standard propylene mesh measuring 15 x 15 cm was cut into two pieces of 4 x 15 cm and 11 x 15 cm. The smaller mesh was placed over both inguinal rings without splitting. The larger mesh was then inserted over the first mesh and stapled to low-risk zones, reinforcing the large-vessel area and the nerve transition zone. The mean procedure duration was 60 minutes for unilateral and 100 minutes for bilateral hernia repair. Patients were discharged from the hospital within 48 hours. The mean postoperative follow-up was 22 months, with no recurrences, neuralgia, or bleeding complications. Over a 2-year period, this technique was found to be satisfactory without recurrences or significant complications. In our hands, this technique was easier to perform: it allows for a less than perfect positioning of the meshes and avoids most of the stapling to crucial zones.
Resumo:
Toxorhynchites mosquitoes play important ecological roles in aquatic microenvironments, and are frequently investigated as potential biological control agents of mosquito disease vectors. Establishment of Toxorhynchites laboratory colonies can be challenging because for some species, mating and insemination either do not occur or require a prohibitive amount of laboratory space for success. Consequently, artificial insemination techniques have been developed to assist with mass rearing of these species. Herein we describe an adapted protocol for colony establishment of T. theobaldi, a species with broad distribution in the Neotropics. The success of the technique and its implications are discussed.
Resumo:
Collection : Bibliothèque du XVe siècle ; 37
Resumo:
O Lean não é apenas uma prática. É uma revolução nas Tecnologias de Informação (TI) proporcionando uma maior e melhor utilização dos recursos e procurando alcançar custos mais baixos dos que existem atualmente. É muito mais do que uma lista de ferramentas e metodologias e para que seja estabelecido é necessário mudar comportamentos culturais e incentivar todas as organizações a pensarem de forma diferente sobre o poder da informação versus o valor do negócio. Normalmente associa-se o Lean à criação de valor para a organização. Mas o valor é significativo quando é trazido com eficiência e resultando na eliminação de processos que consomem tempo, recursos e espaço desnecessário. Os princípios Lean podem ajudar as organizações na melhoria da qualidade, redução de custos e no alcance da eficiência através de uma melhor produtividade. Existem vários conceitos Lean que podem ser associados a diferentes objetivos de resolução de problemas. Em particular, este trabalho é uma dissertação programada para analisar um novo paradigma sobre o Lean que surgiu recentemente - Lean para Tecnologias de Informação (Lean IT). Esta dissertação apresenta uma abordagem para o Lean IT (enquadramento, objetivos e metodologia) para realizar o trabalho e utiliza um único estudo de caso, com abordagem à técnica 5S/6S (até o terceiro nível de avaliação), numa Pequena, Média Empresa (PME), de forma a demonstrar a agregação de valor e as vantagens na eliminação de resíduos/desperdícios nos seus processos. A técnica também mostra a evolução da avaliação antes e depois da sua aplicação. Este estudo de caso individual avalia um Departamento de TI (com uma equipe de cinco colaboradores e um chefe de Departamento) através da observação direta, documentação e arquivos de registos e os equipamentos analisados são computadores, postos de trabalho e projetos (código desenvolvido, portais e outros serviços de TI). x Como guia, a metodologia inclui a preparação da avaliação em conjunto com o responsável/chefe do Departamento de TI, o desenrolar das operações, a identificação do fluxo de valor para cada atividade, o desenvolvimento de um plano de comunicação e a análise de cada passo da avaliação do fluxo de processamento. Os principais resultados estão refletidos nas novas ferramentas de trabalho (Microsoft SharePoint e Microsoft Project em detrimento do Microsoft Excel) que fornecem comunicação remota e controlo de projetos para todos os stakeholders, tais como, a gestão de topo, parceiros e clientes (algumas organizações incluem o Outsourcing no desenvolvimento de funcionalidades específicas). Os resultados também refletem-se na qualidade do trabalho, no cumprimento de prazos, na segurança física e lógica, na motivação dos colaboradores e na satisfação dos clientes. A técnica 5S/6S ajuda a esclarecer os conceitos e princípios Lean, exequibilidade e aumenta a curiosidade sobre a implementação da técnica noutros departamentos tais como o Financeiro e ou o de Recursos Humanos. Como forma de consolidação do trabalho tornou-se possível organizar a avaliação para que a organização possa candidatar-se a uma certificação na norma ISO/IEC 25010:2011, no modelo de qualidade de software (software é o core business desta PME). Mas tal só será possível se toda a organização atingir a padronização dos seus processos. Este estudo de caso mostra que os conceitos Lean e a aplicação de uma ou mais das suas técnicas (neste caso particular a técnica 5S/6S) ajuda a obter melhores resultados através da gestão e melhoria dos seus principais serviços.
Resumo:
Electrotransfer and iontophoresis are being developed as innovative non-viral gene delivery systems for the treatment of eye diseases. These two techniques rely on the use of electric current to allow for higher transfection yield of various ocular cell types in vivo. Short pulses of relatively high-intensity electric fields are used for electrotransfer delivery, whereas the iontophoresis technique is based on the application of low voltage electric current. The basic principles of these techniques and their potential therapeutic application for diseases of the anterior and posterior segments of the eye are reviewed. Iontophoresis has been found most efficient for the delivery of small nucleic acid fragments such as antisense oligonucleotides, siRNA, or ribozymes. Electrotransfer, on the other hand, is being developed for the delivery of oligonucleotides or custom designed plasmids. The wide range of strategies already validated and the potential for targeting specific types of cells confirm the promising early observations made using electrotransfer and iontophoresis. These two nonviral delivery systems are safe and can be used efficiently for targeted gene delivery to ocular tissues in vivo. At the present, their application for the treatment of ocular human diseases is nearing its final stages of adaptation and practical implementation at the bedside.
Resumo:
Background: EEG is the cornerstone of epilepsy diagnostics and mandatory to determine the underlying epilepsy syndrome (e.g. focal vs idiopathic generalized). However, its potential as imaging tool is still underrecognized. In the present study, we aim to determine the prerequisites of maximal benefit of electric source imaging (ESI) to localize the irritative zone in patients with focal epilepsy. Methods: 150 patients suffering from focal epilepsy and with minimum 1 year post-operative follow-up were studied prospectively by reviewers blinded to the underlying diagnosis and outcome. We evaluated the influence of two important factors on sensitivity and specificity of ESI: the number of electrodes (low resolution, LR-ESI: \30 vs. high resolution, HR-ESI: 128-256 electrodes), and the use of individual MRI (i-MRI) vs. template MRI (t-MRI) as head model.Results: ESI had a sensitivity of 85% and a specificity of 87% when HR-ESI with i-MRI was used. Using LR-ESI, sensitivity decreased to 68%, or even 57% when only t-MRI was available. The sensitivity of HR-ESI/i-MRI compared favorably with those of MRI (76%), PET (69%) and ictal/interictal SPECT (64%).Interpretation: This study on a large patient group shows excellent sensitivity and specificity of ESI if 128 EEG channels or more are used for ESI and if the results are co-registered to the patient's individual MRI. Localization precision is as high as or even higher than established brain imaging techniques, providing excellent costeffectiveness in epilepsy evaluation. HR-ESI appears to be a valuable additional imaging tool, given that larger electrode arrays are easily and rapidly applied with modern EEG equipment and that structural MRI is nearly always available for these patients.
Resumo:
Abbaye de Saint-Victor de Paris
Resumo:
The eastern part of the Cordillera Occidental of Ecuador comprises thick buoyant oceanic plateaus associated with island-arc tholeiites and subduction-related calc-alkaline series, accreted to the Ecuadorian Continental Margin from Late Cretaceous to Eocene times. One of these plateau sequences, the Guaranda Oceanic Plateau is considered as remnant of the Caribbean-Colombian Oceanic Province (CCOP) accreted to the Ecuadorian Margin in the Maastrichtien. Samples studied in this paper were taken from four cross-sections through two arc-sequences in the northern part of the Cordillera Occidental of Ecuador, dated as (Rio Cala) or ascribed to (Macuchi) the Late Cretaceous and one arc-like sequence in the Chogon-Colonche Cordillera (Las Orquideas). These three island-arcs can clearly be identified and rest conformably on the CCOP. In all four localities, basalts with abundant large clinopyroxene phenocrysts can be found, mimicking a picritic or ankaramitic facies. This mineralogical particularity, although not uncommon in island arc lavas, hints at a contribution of the CCOP in the genesis of these island arc rocks. The complete petrological and geochemical study of these rocks reveals that some have a primitive island-arc nature (MgO values range from 6 to 11 wt.%). Studied samples display marked Nb, Ta and Ti negative anomalies relative to the adjacent elements in the spidergrams characteristic of subductionrelated magmatism. These rocks are LREE-enriched and their clinopyroxenes show a tholeiitic affinity (FeO(1)-TiO(2) enrichment and CaO depletion from core to rim within a single crystal). The four sampled cross-sections through the island-arc sequences display homogeneous initial Nd, and Pb isotope ratios that suggest a unique mantellic source for these rocks resulting from the mixing of three components: an East-Pacific MORB end-member, an enriched pelagic sediment component, and a HIMU component carried by the CCOP. Indeed, the ankaramite and Mg-basalt sequences that form part of the Caribbean-Colombian Oceanic Plateau are radiogenically enriched in (206)Pb/(204)Pb and (207)Pb/(204)Pb and contain a HIMU component similar to that observed in the Gorgona basalts and Galapagos lavas. The subduction zone that generated the Late Cretaceous arcs occurred far from the continental margin, in an oceanic environment. This implies that no terrigenous detrital sediments interacted with the source at this period. Thus, the enriched component can only result from the melting of subducted pelagic sediments. We have thus defined the East-Pacific MORB, enriched (cherts, pelagic sediments) and HIMU components in an attempt to constrain and model the genesis of the studied island-arc magmatism, using a compilation of carefully selected isotopic data from literature according to rock age and paleogeographic location at the time of arc edification. Tripolar mixing models reveal that proportions of 12-15 wt.% of the HIMU component, 7-15 wt.% of the pelagic sediment end-member and 70-75 wt.% of an East-pacific MORB end-member are needed to explain the measured isotope ratios. These surprisingly high proportions of the HIMU/CCOP component could be explained by the young age of the oceanic plateau (5-15 Ma) during the Late Cretaceous arc emplacement. The CCOP, basement of these arc sequences, was probably still hot and easily assimilated at the island-arc lava source. (C) 2008 Elsevier Ltd. All rights reserved,
Resumo:
La tècnica de l’electroencefalograma (EEG) és una de les tècniques més utilitzades per estudiar el cervell. En aquesta tècnica s’enregistren els senyals elèctrics que es produeixen en el còrtex humà a través d’elèctrodes col•locats al cap. Aquesta tècnica, però, presenta algunes limitacions a l’hora de realitzar els enregistraments, la principal limitació es coneix com a artefactes, que són senyals indesitjats que es mesclen amb els senyals EEG. L’objectiu d’aquest treball de final de màster és presentar tres nous mètodes de neteja d’artefactes que poden ser aplicats en EEG. Aquests estan basats en l’aplicació de la Multivariate Empirical Mode Decomposition, que és una nova tècnica utilitzada per al processament de senyal. Els mètodes de neteja proposats s’apliquen a dades EEG simulades que contenen artefactes (pestanyeigs), i un cop s’han aplicat els procediments de neteja es comparen amb dades EEG que no tenen pestanyeigs, per comprovar quina millora presenten. Posteriorment, dos dels tres mètodes de neteja proposats s’apliquen sobre dades EEG reals. Les conclusions que s’han extret del treball són que dos dels nous procediments de neteja proposats es poden utilitzar per realitzar el preprocessament de dades reals per eliminar pestanyeigs.
Resumo:
PURPOSE: To investigate the ability of inversion recovery ON-resonant water suppression (IRON) in conjunction with P904 (superparamagnetic nanoparticles which consisting of a maghemite core coated with a low-molecular-weight amino-alcohol derivative of glucose) to perform steady-state equilibrium phase MR angiography (MRA) over a wide dose range. MATERIALS AND METHODS: Experiments were approved by the institutional animal care committee. Rabbits (n = 12) were imaged at baseline and serially after the administration of 10 incremental dosages of 0.57-5.7 mgFe/Kg P904. Conventional T1-weighted and IRON MRA were obtained on a clinical 1.5 Tesla (T) scanner to image the thoracic and abdominal aorta, and peripheral vessels. Contrast-to-noise ratios (CNR) and vessel sharpness were quantified. RESULTS: Using IRON MRA, CNR and vessel sharpness progressively increased with incremental dosages of the contrast agent P904, exhibiting constantly higher contrast values than T1 -weighted MRA over a very wide range of contrast agent doses (CNR of 18.8 ± 5.6 for IRON versus 11.1 ± 2.8 for T1 -weighted MRA at 1.71 mgFe/kg, P = 0.02 and 19.8 ± 5.9 for IRON versus -0.8 ± 1.4 for T1-weighted MRA at 3.99 mgFe/kg, P = 0.0002). Similar results were obtained for vessel sharpness in peripheral vessels, (Vessel sharpness of 46.76 ± 6.48% for IRON versus 33.20 ± 3.53% for T1-weighted MRA at 1.71 mgFe/Kg, P = 0.002, and of 48.66 ± 5.50% for IRON versus 19.00 ± 7.41% for T1-weighted MRA at 3.99 mgFe/Kg, P = 0.003). CONCLUSION: Our study suggests that quantitative CNR and vessel sharpness after the injection of P904 are consistently higher for IRON MRA when compared with conventional T1-weighted MRA. These findings apply for a wide range of contrast agent dosages.