980 resultados para DOSE RADIOIODINE THERAPY


Relevância:

30.00% 30.00%

Publicador:

Resumo:

A tenet of modern radiotherapy (RT) is to identify the treatment target accurately, following which the high-dose treatment volume may be expanded into the surrounding tissues in order to create the clinical and planning target volumes. Respiratory motion can induce errors in target volume delineation and dose delivery in radiation therapy for thoracic and abdominal cancers. Historically, radiotherapy treatment planning in the thoracic and abdominal regions has used 2D or 3D images acquired under uncoached free-breathing conditions, irrespective of whether the target tumor is moving or not. Once the gross target volume has been delineated, standard margins are commonly added in order to account for motion. However, the generic margins do not usually take the target motion trajectory into consideration. That may lead to under- or over-estimate motion with subsequent risk of missing the target during treatment or irradiating excessive normal tissue. That introduces systematic errors into treatment planning and delivery. In clinical practice, four-dimensional (4D) imaging has been popular in For RT motion management. It provides temporal information about tumor and organ at risk motion, and it permits patient-specific treatment planning. The most common contemporary imaging technique for identifying tumor motion is 4D computed tomography (4D-CT). However, CT has poor soft tissue contrast and it induce ionizing radiation hazard. In the last decade, 4D magnetic resonance imaging (4D-MRI) has become an emerging tool to image respiratory motion, especially in the abdomen, because of the superior soft-tissue contrast. Recently, several 4D-MRI techniques have been proposed, including prospective and retrospective approaches. Nevertheless, 4D-MRI techniques are faced with several challenges: 1) suboptimal and inconsistent tumor contrast with large inter-patient variation; 2) relatively low temporal-spatial resolution; 3) it lacks a reliable respiratory surrogate. In this research work, novel 4D-MRI techniques applying MRI weightings that was not used in existing 4D-MRI techniques, including T2/T1-weighted, T2-weighted and Diffusion-weighted MRI were investigated. A result-driven phase retrospective sorting method was proposed, and it was applied to image space as well as k-space of MR imaging. Novel image-based respiratory surrogates were developed, improved and evaluated.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

As complex radiotherapy techniques become more readily-practiced, comprehensive 3D dosimetry is a growing necessity for advanced quality assurance. However, clinical implementation has been impeded by a wide variety of factors, including the expense of dedicated optical dosimeter readout tools, high operational costs, and the overall difficulty of use. To address these issues, a novel dry-tank optical CT scanner was designed for PRESAGE 3D dosimeter readout, relying on 3D printed components and omitting costly parts from preceding optical scanners. This work details the design, prototyping, and basic commissioning of the Duke Integrated-lens Optical Scanner (DIOS).

The convex scanning geometry was designed in ScanSim, an in-house Monte Carlo optical ray-tracing simulation. ScanSim parameters were used to build a 3D rendering of a convex ‘solid tank’ for optical-CT, which is capable of collimating a point light source into telecentric geometry without significant quantities of refractive-index matched fluid. The model was 3D printed, processed, and converted into a negative mold via rubber casting to produce a transparent polyurethane scanning tank. The DIOS was assembled with the solid tank, a 3W red LED light source, a computer-controlled rotation stage, and a 12-bit CCD camera. Initial optical phantom studies show negligible spatial inaccuracies in 2D projection images and 3D tomographic reconstructions. A PRESAGE 3D dose measurement for a 4-field box treatment plan from Eclipse shows 95% of voxels passing gamma analysis at 3%/3mm criteria. Gamma analysis between tomographic images of the same dosimeter in the DIOS and DLOS systems show 93.1% agreement at 5%/1mm criteria. From this initial study, the DIOS has demonstrated promise as an economically-viable optical-CT scanner. However, further improvements will be necessary to fully develop this system into an accurate and reliable tool for advanced QA.

Pre-clinical animal studies are used as a conventional means of translational research, as a midpoint between in-vitro cell studies and clinical implementation. However, modern small animal radiotherapy platforms are primitive in comparison with conventional linear accelerators. This work also investigates a series of 3D printed tools to expand the treatment capabilities of the X-RAD 225Cx orthovoltage irradiator, and applies them to a feasibility study of hippocampal avoidance in rodent whole-brain radiotherapy.

As an alternative material to lead, a novel 3D-printable tungsten-composite ABS plastic, GMASS, was tested to create precisely-shaped blocks. Film studies show virtually all primary radiation at 225 kVp can be attenuated by GMASS blocks of 0.5cm thickness. A state-of-the-art software, BlockGen, was used to create custom hippocampus-shaped blocks from medical image data, for any possible axial treatment field arrangement. A custom 3D printed bite block was developed to immobilize and position a supine rat for optimal hippocampal conformity. An immobilized rat CT with digitally-inserted blocks was imported into the SmART-Plan Monte-Carlo simulation software to determine the optimal beam arrangement. Protocols with 4 and 7 equally-spaced fields were considered as viable treatment options, featuring improved hippocampal conformity and whole-brain coverage when compared to prior lateral-opposed protocols. Custom rodent-morphic PRESAGE dosimeters were developed to accurately reflect these treatment scenarios, and a 3D dosimetry study was performed to confirm the SmART-Plan simulations. Measured doses indicate significant hippocampal sparing and moderate whole-brain coverage.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Radiotherapy is commonly used to treat lung cancer. However, radiation induced damage to lung tissue is a major limiting factor to its use. To minimize normal tissue lung toxicity from conformal radiotherapy treatment planning, we investigated the use of Perfluoropropane(PFP)-enhanced MR imaging to assess and guide the sparing of functioning lung. Fluorine Enhanced MRI using Perfluoropropane(PFP) is a dynamic multi-breath steady state technique enabling quantitative and qualitative assessments of lung function(1).

Imaging data was obtained from studies previously acquired in the Duke Image Analysis Laboratory. All studies were approved by the Duke IRB. The data was de-identified for this project, which was also approved by the Duke IRB. Subjects performed several breath-holds at total lung capacity(TLC) interspersed with multiple tidal breaths(TB) of Perfluoropropane(PFP)/oxygen mixture. Additive wash-in intensity images were created through the summation of the wash-in phase breath-holds. Additionally, model based fitting was utilized to create parametric images of lung function(1).

Varian Eclipse treatment planning software was used for putative treatment planning. For each subject two plans were made, a standard plan, with no regional functional lung information considered other than current standard models. Another was created using functional information to spare functional lung while maintaining dose to the target lesion. Plans were optimized to a prescription dose of 60 Gy to the target over the course of 30 fractions.

A decrease in dose to functioning lung was observed when utilizing this functional information compared to the standard plan for all five subjects. PFP-enhanced MR imaging is a feasible method to assess ventilatory lung function and we have shown how this can be incorporated into treatment planning to potentially decrease the dose to normal tissue.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

GM2 gangliosidoses is a family of severe, neurodegenerative disorders resulting from a deficiency in the β-hexosaminidase A (Hex A) enzyme. This disorder is typically caused by a mutation to either the HEXA gene, causing Tay Sachs disease, or a mutation to the HEXB gene, causing Sandhoff disease. The HEXA and HEXB genes are required to produce the α and β subunits of the Hex A enzyme respectively. Using a Sandhoff disease (SD) mouse model (Hexb-/-) we tested the potential of a low dose of systemically delivered single stranded adeno-associated virus 9 (ssAAV9) expressing human HEXB and human HEXA cDNA under the control of a single promoter through the use of a bicistronic vector design with a P2A linker to correct the neurological phenotype. Neonatal mice were injected with either this ssAAV9-HexB-P2A-HexA vector (HexB-HexA) or a vehicle solution via the superficial temporal vein. HexB-HexA treatment alone conferred an increase in survival of 56% compared to vehicle-injected controls and biochemical analysis of the brain tissue and serum revealed an increase in HexA activity and a decrease in brain GM2 ganglioside buildup. Additionally, treatments with the non-steroidal anti-inflammatory drug indomethacin (Indo), the histone deactylase inhibitor ITF2357 (ITF) and the pharmacological chaperone pyrimethamine (Pyr) were tested. The anti-inflammatory treatments of Indo and ITF conferred an increase in survival of 12% and 8% respectively while causing no alteration in the HexA activity or GM2 ganglioside buildup. Pyr had no observable effect on disease progression. Lastly HexB-HexA treatment was tested in conjunction with Indo, ITF and Pyr individually. Additive increases in survival and behavioural testing results were observed with Indo and ITF treatments while no additional benefit to HexA activity or GM2 ganglioside levels in the brain tissue was observed. This indicates the two treatments slowed the progression of the disease through a different mechanism than the reduction of the GM2 ganglioside substrate. Pyr treatment was shown to have no effect when combined with HexB-HexA treatment. This study demonstrates the potential amelioration of SD with a novel AAV9 gene therapy approach as well as helped to identify the additive potential of anti-inflammatory treatments in gene therapy of GM2 gangliosidoses.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background Lumacaftor/ivacaftor combination therapy demonstrated clinical benefits inpatients with cystic fibrosis homozygous for the Phe508del CFTR mutation.Pretreatment lung function is a confounding factor that potentially impacts the efficacyand safety of lumacaftor/ivacaftor therapy. Methods Two multinational, randomised, double-blind, placebo-controlled, parallelgroupPhase 3 studies randomised patients to receive placebo or lumacaftor (600 mgonce daily [qd] or 400 mg every 12 hours [q12h]) in combination with ivacaftor (250 mgq12h) for 24 weeks. Prespecified analyses of pooled efficacy and safety data by lungfunction, as measured by percent predicted forced expiratory volume in 1 second(ppFEV1), were performed for patients with baseline ppFEV1 <40 (n=81) and ≥40(n=1016) and screening ppFEV1 <70 (n=730) and ≥70 (n=342). These studies wereregistered with ClinicalTrials.gov (NCT01807923 and NCT01807949). Findings The studies were conducted from April 2013 through April 2014.Improvements in the primary endpoint, absolute change from baseline at week 24 inppFEV1, were observed with both lumacaftor/ivacaftor doses in the subgroup withbaseline ppFEV1 <40 (least-squares mean difference versus placebo was 3∙7 and 3.3percentage points for lumacaftor 600 mg qd/ivacaftor 250 mg q12h and lumacaftor 400mg q12h/ivacaftor 250 mg q12h, respectively [p<0∙05] and in the subgroup with baselineppFEV1 ≥40 (3∙3 and 2∙8 percentage points, respectively [p<0∙001]). Similar absoluteimprovements versus placebo in ppFEV1 were observed in subgroups with screening 4ppFEV1 <70 (3∙3 and 3∙3 percentage points for lumacaftor 600 mg qd/ivacaftor 250 mgq12h and lumacaftor 400 mg q12h/ivacaftor 250 mg q12h, respectively [p<0∙001]) and≥70 (3∙3 and 1∙9 percentage points, respectively [p=0.002] and [p=0∙079]). Increases inBMI and reduction in number of pulmonary exacerbation events were observed in bothLUM/IVA dose groups vs placebo across all lung function subgroups. Treatment wasgenerally well tolerated, although the incidence of some respiratory adverse events washigher with active treatment than with placebo. Interpretation Lumacaftor/ivacaftor combination therapy benefits patients homozygousfor Phe508del CFTR who have varying degrees of lung function impairment. Funding Vertex Pharmaceuticals Incorporated.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The role of antiplatelet therapy as primary prophylaxis of thrombosis in low-risk essential thrombocythemia has not been studied in randomized clinical trials. We assessed the benefit/risk of low-dose aspirin in 433 low-risk essential thrombocythemia patients (CALR-mutated n=271, JAK2V617F-mutated n=162) who were on antiplatelet therapy or observation only. After a 2215 person-years follow-up free from cytoreduction, 25 thrombotic and 17 bleeding episodes were recorded. In CALR-mutated patients, antiplatelet therapy did not affect the risk of thrombosis but was associated with a higher incidence of bleeding (12.9 vs. 1.8 x1000 patient-years, p=0.03). In JAK2V617F-mutated patients, low-dose aspirin was associated with a reduced incidence of venous thrombosis with no effect on the risk of bleeding. Coexistence of JAK2V617F-mutation and cardiovascular risk factors increased the risk of thrombosis, even after adjusting for treatment with low-dose aspirin (incidence rate ratio: 9.8; 95% confidence interval: 2.3-42.3; p=0.02). Time free from cytoreduction was significantly shorter in CALR-mutated than in JAK2V617F-mutated essential thrombocythemia (median time 5 years and 9.8 years, respectively; p=0.0002) usually to control extreme thrombocytosis. In conclusion, in patients with low-risk, CALR-mutated essential thrombocythemia, low-dose aspirin does not reduce the risk of thrombosis and may increase the risk of bleeding.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: Prostate cancer might have high radiation-fraction sensitivity that would give a therapeutic advantage to hypofractionated treatment. We present a pre-planned analysis of the efficacy and side-effects of a randomised trial comparing conventional and hypofractionated radiotherapy after 5 years follow-up.

METHODS: CHHiP is a randomised, phase 3, non-inferiority trial that recruited men with localised prostate cancer (pT1b-T3aN0M0). Patients were randomly assigned (1:1:1) to conventional (74 Gy delivered in 37 fractions over 7·4 weeks) or one of two hypofractionated schedules (60 Gy in 20 fractions over 4 weeks or 57 Gy in 19 fractions over 3·8 weeks) all delivered with intensity-modulated techniques. Most patients were given radiotherapy with 3-6 months of neoadjuvant and concurrent androgen suppression. Randomisation was by computer-generated random permuted blocks, stratified by National Comprehensive Cancer Network (NCCN) risk group and radiotherapy treatment centre, and treatment allocation was not masked. The primary endpoint was time to biochemical or clinical failure; the critical hazard ratio (HR) for non-inferiority was 1·208. Analysis was by intention to treat. Long-term follow-up continues. The CHHiP trial is registered as an International Standard Randomised Controlled Trial, number ISRCTN97182923.

FINDINGS: Between Oct 18, 2002, and June 17, 2011, 3216 men were enrolled from 71 centres and randomly assigned (74 Gy group, 1065 patients; 60 Gy group, 1074 patients; 57 Gy group, 1077 patients). Median follow-up was 62·4 months (IQR 53·9-77·0). The proportion of patients who were biochemical or clinical failure free at 5 years was 88·3% (95% CI 86·0-90·2) in the 74 Gy group, 90·6% (88·5-92·3) in the 60 Gy group, and 85·9% (83·4-88·0) in the 57 Gy group. 60 Gy was non-inferior to 74 Gy (HR 0·84 [90% CI 0·68-1·03], pNI=0·0018) but non-inferiority could not be claimed for 57 Gy compared with 74 Gy (HR 1·20 [0·99-1·46], pNI=0·48). Long-term side-effects were similar in the hypofractionated groups compared with the conventional group. There were no significant differences in either the proportion or cumulative incidence of side-effects 5 years after treatment using three clinician-reported as well as patient-reported outcome measures. The estimated cumulative 5 year incidence of Radiation Therapy Oncology Group (RTOG) grade 2 or worse bowel and bladder adverse events was 13·7% (111 events) and 9·1% (66 events) in the 74 Gy group, 11·9% (105 events) and 11·7% (88 events) in the 60 Gy group, 11·3% (95 events) and 6·6% (57 events) in the 57 Gy group, respectively. No treatment-related deaths were reported.

INTERPRETATION: Hypofractionated radiotherapy using 60 Gy in 20 fractions is non-inferior to conventional fractionation using 74 Gy in 37 fractions and is recommended as a new standard of care for external-beam radiotherapy of localised prostate cancer.

FUNDING: Cancer Research UK, Department of Health, and the National Institute for Health Research Cancer Research Network.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

AZEVEDO, George Dantas de et al. Raloxifene therapy does not affect uterine blood flow in postmenopausal women: a transvaginal Doppler study. Maturitas, Amsterdam, v.47, n.3, p.195-200, 2004

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In Nuclear Medicine, radioiodine, in various chemical forms, is a key tracer used in diagnostic practices and/or therapy. Due to its high volatility, medical professionals may incorporate radioactive iodine during the preparation of the dose to be administered to the patient. In radioactive iodine therapy doses ranging from 3.7 to 7.4GBq per patient are employed. Thus, aiming at reducing the risk of occupational contamination, we developed a low cost filter to be installed at the exit of the exhaust system where doses of radioactive iodine are fractionated, using domestic technology. The effectiveness of radioactive iodine retention by silver impregnated silica [10%] crystals and natural activated carbon was verified using radiotracer techniques. The results showed that natural activated carbon is effective for I2 capture for a large or small amount of substrate but its use is restricted due to its low flash point (150º C). Besides, when poisoned by organic solvents, this flash point may become lower, causing explosions if absorbing large amounts of nitrates. To hold the CH3I gas, it was necessary to increase the volume of natural activated carbon since it was not absorbed by SiO2 + Ag crystals. We concluded that, for an exhaust flow range of (306 4) m3/h, a double stage filter using SiO2 + Ag in the first stage and natural activated carbon in the second is sufficient to meet radiological safety requirements.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

AZEVEDO, George Dantas de et al. Raloxifene therapy does not affect uterine blood flow in postmenopausal women: a transvaginal Doppler study. Maturitas, Amsterdam, v.47, n.3, p.195-200, 2004

Relevância:

30.00% 30.00%

Publicador:

Resumo:

International audience