913 resultados para Corneal biomechanics


Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND: Complex foot and ankle fractures, such as calcaneum fractures or Lisfranc dislocations, are often associated with a poor outcome, especially in terms of gait capacity. Indeed, degenerative changes often lead to chronic pain and chronic functional limitations. Prescription footwear represents an important therapeutic tool during the rehabilitation process. Local Dynamic Stability (LDS) is the ability of locomotor system to maintain continuous walking by accommodating small perturbations that occur naturally during walking. Because it reflects the degree of control over the gait, LDS has been advocated as a relevant indicator for evaluating different conditions and pathologies. The aim of this study was to analyze changes in LDS induced by orthopaedic shoes in patients with persistent foot and ankle injuries. We hypothesised that footwear adaptation might help patients to improve gait control, which could lead to higher LDS: METHODS: Twenty-five middle-aged inpatients (5 females, 20 males) participated in the study. They were treated for chronic post-traumatic disabilities following ankle and/or foot fractures in a Swiss rehabilitation clinic. During their stay, included inpatients received orthopaedic shoes with custom-made orthoses (insoles). They performed two 30s walking trials with standard shoes and two 30s trials with orthopaedic shoes. A triaxial motion sensor recorded 3D accelerations at the lower back level. LDS was assessed by computing divergence exponents in the acceleration signals (maximal Lyapunov exponents). Pain was evaluated with Visual Analogue Scale (VAS). LDS and pain differences between the trials with standard shoes and the trials with orthopaedic shoes were assessed. RESULTS: Orthopaedic shoes significantly improved LDS in the three axes (medio-lateral: 10% relative change, paired t-test p < 0.001; vertical: 9%, p = 0.03; antero-posterior: 7%, p = 0.04). A significant decrease in pain level (VAS score -29%) was observed. CONCLUSIONS: Footwear adaptation led to pain relief and to improved foot & ankle proprioception. It is likely that that enhancement allows patients to better control foot placement. As a result, higher dynamic stability has been observed. LDS seems therefore a valuable index that could be used in early evaluation of footwear outcome in clinical settings.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE: This study aimed to highlight structural corneal changes in a model of type 2 diabetes, using in vivo corneal confocal microscopy (CCM). The abnormalities were also characterized by transmission electron microscopy (TEM) and second harmonic generation (SHG) microscopy in rat and human corneas. METHODS: Goto-Kakizaki (GK) rats were observed at age 12 weeks (n = 3) and 1 year (n = 6), and compared to age-matched controls. After in vivo CCM examination, TEM and SHG microscopy were used to characterize the ultrastructure and the three-dimensional organization of the abnormalities. Human corneas from diabetic (n = 3) and nondiabetic (n = 3) patients were also included in the study. RESULTS: In the basal epithelium of GK rats, CCM revealed focal hyper-reflective areas, and histology showed proliferative cells with irregular basement membrane. In the anterior stroma, extracellular matrix modifications were detected by CCM and confirmed in histology. In the Descemet's membrane periphery of all the diabetic corneas, hyper-reflective deposits were highlighted using CCM and characterized as long-spacing collagen fibrils by TEM. SHG microscopy revealed these deposits with high contrast, allowing specific detection in diabetic human and rat corneas without preparation and characterization of their three-dimensional organization. CONCLUSION: Pathologic findings were observed early in the development of diabetes in GK rats. Similar abnormalities have been found in corneas from diabetic patients. TRANSLATIONAL RELEVANCE: This multidisciplinary study highlights diabetes-induced corneal abnormalities in an animal model, but also in diabetic donors. This could constitute a potential early marker for diagnosis of hyperglycemia-induced tissue changes.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

AbstractPurpose: to evaluate the tolerability, comfort and precision of the signal transmission of an ocular Sensor used for 24-hour intraocular pressure fluctuation monitoring in humans.Patients and methods: In this uncontrolled open trial involving 10 healthy volunteers an 8.7 mm radius prototype ocular telemetry Sensor (SENSIMED Triggerfish®, Lausanne, Switzerland) and an orbital bandage containing a loop antenna were applied and connected to a portable recorder after full eye examination. Best corrected visual acuity and position, surface wetting ability and mobility of the Sensor were assessed after 5 and 30 minutes, 4, 12 and 24 hours. Subjective wearing comfort was scored and activities documented in a logbook. After Sensor removal a full eye examination was repeated and the recorded signal analyzed.Results: The comfort score was high and did not fluctuate significantly over time. The mobility of the Sensor was limited across follow-up visits and its surface wetting ability remained good. Best corrected visual acuity was significantly reduced during Sensor wear and immediately after its removal (from 1.07 before, to 0.85 after, P-value 0.008). Three subjects developed a mild, transient corneal abrasion. In all but one participant we obtained usable data of a telemetric signal recording with sufficient sensitivity to depict ocular pulsation.Conclusions: This 24-hour- trial has encouraging results on the tolerability and functionality of the ocular telemetric Sensor for intraocular pressure fluctuation monitoring. Further studies with different Sensor radii conducted on a larger study population are needed to improve comfort, precision and interpretation of the telemetric signal.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The integrity of the cornea, the most anterior part of the eye, is indispensable for vision. Forty-five million individuals worldwide are bilaterally blind and another 135 million have severely impaired vision in both eyes because of loss of corneal transparency; treatments range from local medications to corneal transplants, and more recently to stem cell therapy. The corneal epithelium is a squamous epithelium that is constantly renewing, with a vertical turnover of 7 to 14 days in many mammals. Identification of slow cycling cells (label-retaining cells) in the limbus of the mouse has led to the notion that the limbus is the niche for the stem cells responsible for the long-term renewal of the cornea; hence, the corneal epithelium is supposedly renewed by cells generated at and migrating from the limbus, in marked opposition to other squamous epithelia in which each resident stem cell has in charge a limited area of epithelium. Here we show that the corneal epithelium of the mouse can be serially transplanted, is self-maintained and contains oligopotent stem cells with the capacity to generate goblet cells if provided with a conjunctival environment. Furthermore, the entire ocular surface of the pig, including the cornea, contains oligopotent stem cells (holoclones) with the capacity to generate individual colonies of corneal and conjunctival cells. Therefore, the limbus is not the only niche for corneal stem cells and corneal renewal is not different from other squamous epithelia. We propose a model that unifies our observations with the literature and explains why the limbal region is enriched in stem cells.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVES: In vitro mechanical injury of articular cartilage is useful to identify events associated with development of post-traumatic osteoarthritis (OA). To date, many in vitro injury models have used animal cartilage despite the greater clinical relevance of human cartilage. We aimed to characterize a new in vitro injury model using elderly human femoral head cartilage and compare its behavior to that of an existing model with adult bovine humeral head cartilage. DESIGN: Mechanical properties of human and bovine cartilage disks were characterized by elastic modulus and hydraulic permeability in radially confined axial compression, and by Young's modulus, Poisson's ratio, and direction-dependent radial strain in unconfined compression. Biochemical composition was assessed in terms of tissue water, solid, and glycosaminoglycan (GAG) contents. Responses to mechanical injury were assessed by observation of macroscopic superficial tissue cracks and histological measurements of cell viability following single injurious ramp loads at 7 or 70%/s strain rate to 3 or 14 MPa peak stress. RESULTS: Confined compression moduli and Young's moduli were greater in elderly human femoral cartilage vs adult bovine humeral cartilage whereas hydraulic permeability was less. Radial deformations of axially compressed explant disks were more anisotropic (direction-dependent) for the human cartilage. In both cartilage sources, tissue cracking and associated cell death during injurious loading was common for 14 MPa peak stress at both strain rates. CONCLUSION: Despite differences in mechanical properties, acute damage induced by injurious loading was similar in both elderly human femoral cartilage and adult bovine humeral cartilage, supporting the clinical relevance of animal-based cartilage injury models. However, inherent structural differences such as cell density may influence subsequent cell-mediated responses to injurious loading and affect the development of OA.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This study investigated fatigue-induced changes in spring-mass model characteristics during repeated running sprints. Sixteen active subjects performed 12 × 40 m sprints interspersed with 30 s of passive recovery. Vertical and anterior-posterior ground reaction forces were measured at 5-10 m and 30-35 m and used to determine spring-mass model characteristics. Contact (P &lt; 0.001), flight (P &lt; 0.05) and swing times (P &lt; 0.001) together with braking, push-off and total stride durations (P &lt; 0.001) lengthened across repetitions. Stride frequency (P &lt; 0.001) and push-off forces (P &lt; 0.05) decreased with fatigue, whereas stride length (P = 0.06), braking (P = 0.08) and peak vertical forces (P = 0.17) changes approached significance. Center of mass vertical displacement (P &lt; 0.001) but not leg compression (P &gt; 0.05) increased with time. As a result, vertical stiffness decreased (P &lt; 0.001) from the first to the last repetition, whereas leg stiffness changes across sprint trials were not significant (P &gt; 0.05). Changes in vertical stiffness were correlated (r &gt; 0.7; P &lt; 0.001) with changes in stride frequency. When compared to 5-10 m, most of ground reaction force-related parameters were higher (P &lt; 0.05) at 30-35 m, whereas contact time, stride frequency, vertical and leg stiffness were lower (P &lt; 0.05). Vertical stiffness deteriorates when 40 m run-based sprints are repeated, which alters impact parameters. Maintaining faster stride frequencies through retaining higher vertical stiffness is a prerequisite to improve performance during repeated sprinting.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

HYPOTHESIS: Supraspinatus deficiency associated with total shoulder arthroplasty (TSA) provokes eccentric loading and may induce loosening of the glenoid component. A downward inclination of the glenoid component has been proposed to balance supraspinatus deficiency. METHODS: This hypothesis was assessed by a numeric musculoskeletal model of the glenohumeral joint during active abduction. Three cases were compared: TSA with normal muscular function, TSA with supraspinatus deficiency, and TSA with supraspinatus deficiency and downward inclination of the glenoid. RESULTS: Supraspinatus deficiency increased humeral migration and eccentric loading. A downward inclination of the glenoid partly balanced the loss of stability, but this potential advantage was counterbalanced by an important stress increase within the glenoid cement. The additional subchondral bone reaming required to incline the glenoid component indeed reduced the bone support, increasing cement deformation and stress. CONCLUSION: Glenoid inclination should not be obtained at the expense of subchondral bone support.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE: The objective was to explore whether a satellite-based navigation system, global positioning system used in differential mode (DGPS), could accurately assess the speed of running in humans. METHODS: A subject was equipped with a portable GPS receptor coupled to a receiver for differential corrections, while running outdoors on a straight asphalt road at 27 different speeds. Actual speed (reference method) was assessed by chronometry. RESULTS: The accuracy of speed prediction had a standard deviation (SD) of 0.08 km x h(-1) for walking, 0.11 km x h(-1) for running, yielding a coefficient of variation (SD/mean) of 1.38% and 0.82%, respectively. There was a highly significant linear relationship between actual and DGPS speed assessment (r2 = 0.999) with little bias in the prediction equation, because the slope of the regression line was close to unity (0.997). CONCLUSION: the DGPS technique appears to be a valid and inconspicuous tool for "on line" monitoring of the speed of displacement of individuals located on any field on earth, for prolonged periods of time and unlimited distance, but only in specific environmental conditions ("open sky"). Furthermore, the accuracy of speed assessment using the differential GPS mode was improved by a factor of 10 as compared to non-differential GPS.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: Aqueous shunt implantation into the anterior chamber is associated with corneal decompensation in up to a third of eyes. Intracameral tube position may affect corneal endothelial cell loss. The authors set out to examine the efficacy and safety of Baerveldt shunt implantation into the ciliary sulcus combined with surgical peripheral iridectomy (SPI). Methods: One hundred eyes prospectively underwent Baerveldt shunt implantation into the cilliary sulcus combined with SPI, leaving a short intracameral tube length (1-2mm). Pre and post operative measures recorded included patient demographics, visual acuity, IOP, number of glaucoma medications (GMs) and all complications. Pre-existing corneal decompensation was recorded. Success was defined as IOP≤21mmHg and 20% reduction in IOP from baseline with or without GMs. Results: Mean age was 65.4 years (±20.4years). Mean follow-up was 10.8 months. Preoperatively IOP was 25.7mmHg (± 9.9mmHg), GMs were 2.9 (±1.2) and VA was 0.4 (±0.3). At one year postoperatively there was a significant drop in IOP (mean= 13.3mmHg (± 5.0mmHg); p<0.001) and number of GMs (mean= 1.3 (±1.4); p<0.001); and no significant change in VA (mean= 0.4 (±0.3); p=0.93). The success rate at one year was 83%. Complications were minor and non sight threatening (10%), there were no cases of postoperative corneal decompensation, tube blockage or iris/corneal-tube contact. Conclusions: The results demonstrate that placement of Baerveldt shunts into the ciliary sulcus with SPI is a safe and efficacious method of IOP reduction in comparison with standard shunt positioning in the anterior chamber. The intracameral tube position combined with SPI avoided tube-iris contact and corneal decompensation. Sulcus placement of aqueous shunts should be considered in pseudophakic eyes.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE: To describe the clinical, spectral-domain optical coherence tomography and electrophysiological features of C1QTNF5-associated late-onset retinal degeneration in a molecularly confirmed pedigree. METHODS: Five members of a family participated, and affected individuals (n = 4) underwent detailed ophthalmologic evaluation including fundus autofluorescence and spectral-domain optical coherence tomography imaging and electroretinography. Electrooculography was performed in three individuals. RESULTS: The visual acuity was initially normal and worsened with time. Anterior segment abnormalities included peripupillary iris atrophy and long anterior insertion of zonules. Peripapillary atrophy, drusenoid deposition, and scalloped sectorial chorioretinal atrophy were observed in all older individuals (n = 3). Fundus autofluorescence demonstrated hypofluorescent areas corresponding to regions of chorioretinal atrophy. The spectral-domain optical coherence tomography demonstrated multiple areas of retinal pigment epithelium-Bruch membrane separation with intervening homogeneous deposition that corresponded to the drusenoid lesions and areas of chorioretinal atrophy. Electrooculography was normal in one individual and showed abnormally low dark trough measures in older individuals (n = 2). Electroretinography was normal in early stages (n = 1), but showed marked abnormalities in the rod system (n = 3), which was predominantly inner retinal (n = 2) in late stages. CONCLUSION: Late-onset retinal degeneration is a progressive degeneration, and anterior segment abnormalities present early. The widespread sub-retinal pigment epithelium deposition seen on spectral-domain optical coherence tomography in older individuals appears to be a characteristic in late stages. Electrooculography demonstrates abnormalities only in late stages of the disease.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE: Despite ubiquitous expression of the keratoepithelin (KE) protein encoded by the transforming growth factor beta induced/beta induced gene human clone 3 (TGFBI/BIGH3) gene, corneal dystrophies are restricted to the cornea, and no other tissues are affected. We investigated the role of TGFBI/BIGH3 in Groenouw corneal dystrophies by generating transgenic mice overexpressing TGFBI/BIGH3 containing the R555W mutation. METHODS: Transgenic animals expressing the Groenouw mutation of human TGFBI/BIGH3 were generated using lentiviral vectors. The line expressed TGFBI/BIGH3 containing the R555W mutation under the control of the phosphoglycerate kinase (PGK) promoter. Expression of the transgene was monitored by Southern and western blotting and by RT-PCR. Electroretinogram analysis was performed and four mice were subjected to complete necroscopy. RESULTS: Transgene expression was observed in different organs although without specific expression in the cornea. The overall morphology of the transgenic animals was not severely affected by KE overexpression. However, we observed an age-dependent retinal degeneration both functionally and histologically. Female-specific follicular hyperplasia in the spleen and increased levels of lipofuscin in the adrenal gland were also seen in transgenic animals. CONCLUSIONS: Cellular degeneration in the retina of transgenic animals suggest that perturbation of the transforming growth factor beta (TGFbeta) family regulation may affect photoreceptor survival and may induce possible accelerated aging in several tissues. No corneal phenotype could be observed, probably due to the lack of transgene expression in this tissue.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This study aims to design a wearable system for kinetics measurement of multi-segment foot joints in long-distance walking and to investigate its suitability for clinical evaluations. The wearable system consisted of inertial sensors (3D gyroscopes and 3D accelerometers) on toes, forefoot, hindfoot, and shank, and a plantar pressure insole. After calibration in a laboratory, 10 healthy elderly subjects and 12 patients with ankle osteoarthritis walked 50m twice wearing this system. Using inverse dynamics, 3D forces, moments, and power were calculated in the joint sections among toes, forefoot, hindfoot, and shank. Compared to those we previously estimated for a one-segment foot model, the sagittal and transverse moments and power in the ankle joint, as measured via multi-segment foot model, showed a normalized RMS difference of less than 11%, 14%, and 13%, respectively, for healthy subjects, and 13%, 15%, and 14%, for patients. Similar to our previous study, the coronal moments were not analyzed. Maxima-minima values of anterior-posterior and vertical force, sagittal moment, and power in shank-hindfoot and hindfoot-forefoot joints were significantly different between patients and healthy subjects. Except for power, the inter-subject repeatability of these parameters was CMC>0.90 for healthy subjects and CMC>0.70 for patients. Repeatability of these parameters was lower for the forefoot-toes joint. The proposed measurement system estimated multi-segment foot joints kinetics with acceptable repeatability but showed difference, compared to those previously estimated for the one-segment foot model. These parameters also could distinguish patients from healthy subjects. Thus, this system is suggested for outcome evaluations of foot treatments.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Hallux valgus arises from static and dynamic unbalance of the forefoot. Possibilities of conservative treatment are limited. This paper recalls the essentials of physiopathology and exposes briefly to the non-operators the most current amongst 150 operative techniques described. While becoming more complex, the surgery of hallux valgus has proven to gain efficiency. Surgical indication, based on biomechanics, should be very careful, which gives a greater interest to this discipline.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: to describe a case in which the diagnosis of Morganian cataract required clinical and instrumental differentiation from iris pathologies, including iris melanoma. Methods: a 60-years-old Caucasian man referred to our institute for worsening of vision in last few months. Clinical evaluation consisted in complete ophthalmological assessment, ultrasound examination (biomicroscopy and 20MHz), and Magnetic Resonance Imaging (MRI) completed with Susceptibility Weighted Imaging (SWI). Results: traumatic corneal wound of the left eye (LE) had occurred 5 years before, and was treated with medical therapy alone. Best-corrected visual acuity (BCVA) was 3/10 in the right eye (RE) and finger count in the LE, with intraocular pressure at 13 and 20mmHg, respectively. Chronic central serous chorioretinopathy, accounted for the low visual acuity of the RE. Slit-lamp biomicroscopy of the LE was as in Figure 1; LE fundus was not clinically observable. Despite MRI was compatible with an iris solid formation, characterized by contrast enhancement and hyperintense signal in SWI, ultrasound indicated rather a mixed solid and liquid content (moderately echogenic external layer, hyporeflective internal content). Iris root and ciliary body were not significantly altered; the lens showed inhomogeneous content. We considered Morgagnian cataract the most probable diagnosis. Surgery confirmed the presence of a hypermature cataract with prior anterior capsule fissuring; the liquefied cortex infiltrated the iris without anterior chamber seeping. Post-operative BCVA was 3/10 and fundus examination disclosed an advanced macular chronic central serous chorioretinopathy. Conclusions: In the reported case a previous perforating trauma have probably damaged the lens capsule and started cataract progression. Curiously cataract developed percolating into the iris stroma, thus simulating an iris mass. At our knowledge, Morgagnian cataract has never been included in the differential diagnosis of iris mass.