883 resultados para Cooperatives of recyclable material pickers


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The spectral efficiency achievable with joint processing of pilot and data symbol observations is compared with that achievable through the conventional (separate) approach of first estimating the channel on the basis of the pilot symbols alone, and subsequently detecting the datasymbols. Studied on the basis of a mutual information lower bound, joint processing is found to provide a non-negligible advantage relative to separate processing, particularly for fast fading. It is shown that, regardless of the fading rate, only a very small number of pilot symbols (at most one per transmit antenna and per channel coherence interval) shouldbe transmitted if joint processing is allowed.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper derives approximations allowing the estimation of outage probability for standard irregular LDPC codes and full-diversity Root-LDPC codes used over nonergodic block-fading channels. Two separate approaches are discussed: a numerical approximation, obtained by curve fitting, for both code ensembles, and an analytical approximation for Root-LDPC codes, obtained under the assumption that the slope of the iterative threshold curve of a given code ensemble matches the slope of the outage capacity curve in the high-SNR regime.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The optimization of the pilot overhead in wireless fading channels is investigated, and the dependence of this overhead on various system parameters of interest (e.g., fading rate, signal-to-noise ratio) is quantified. The achievable pilot-based spectral efficiency is expanded with respect to the fading rate about the no-fading point, which leads to an accurate order expansion for the pilot overhead. This expansion identifies that the pilot overhead, as well as the spectral efficiency penalty with respect to a reference system with genie-aided CSI (channel state information) at the receiver, depend on the square root of the normalized Doppler frequency. It is also shown that the widely-usedblock fading model is a special case of more accurate continuous fading models in terms of the achievable pilot-based spectral efficiency. Furthermore, it is established that the overhead optimization for multiantenna systems is effectively the same as for single-antenna systems with thenormalized Doppler frequency multiplied by the number of transmit antennas.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Malignant melanoma, the deadliest form of skin cancer, is characterized by a predominant mutation in the BRAF gene. Drugs that target tumours carrying this mutation have recently entered the clinic. Accordingly, patients are routinely screened for mutations in this gene to determine whether they can benefit from this type of treatment. The current gold standard for mutation screening uses real-time polymerase chain reaction and sequencing methods. Here we show that an assay based on microcantilever arrays can detect the mutation nanomechanically without amplification in total RNA samples isolated from melanoma cells. The assay is based on a BRAF-specific oligonucleotide probe. We detected mutant BRAF at a concentration of 500 pM in a 50-fold excess of the wild-type sequence. The method was able to distinguish melanoma cells carrying the mutation from wild-type cells using as little as 20 ng µl(-1) of RNA material, without prior PCR amplification and use of labels.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The purpose of this study was to design microspheres combining sustained delivery and enhanced intracellular penetration for ocular administration of antisense oligonucleotides. Nanosized complexes of antisense TGF-beta2 phosphorothioate oligonucleotides (PS-ODN) with polyethylenimine (PEI), and naked PS-ODN were encapsulated into poly(lactide-co-glycolide) microspheres prepared by the double-emulsion solvent evaporation method. The PS-ODN was introduced either naked or complexed in the inner aqueous phase of the first emulsion. We observed a marked influence of microsphere composition on porosity, size distribution and PS-ODN encapsulation efficiency. Mainly, the presence of PEI induced the formation of large pores observed onto microsphere surface. Introduction of NaCl in the outer aqueous phase increased the encapsulation efficiency and reduced microsphere porosity. In vitro release kinetic of PS-ODN was also investigated. Clearly, the higher the porosity, the faster was the release and the higher was the burst effect. Using an analytical solution of Fick's second law of diffusion, it was shown that the early phase of PS-ODN and PS-ODN-PEI complex release was primarily controlled by pure diffusion, irrespectively of the type of microsphere. Finally, microspheres containing antisense TGF-beta2 nanosized complexes were shown, after subconjunctival administration to rabbit, to significantly increase intracellular penetration of ODN in conjunctival cells and subsequently to improve bleb survival in a rabbit experimental model of filtering surgery. These results open up interesting prospective for the local controlled delivery of genetic material into the eye.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper presents our investigation on iterativedecoding performances of some sparse-graph codes on block-fading Rayleigh channels. The considered code ensembles are standard LDPC codes and Root-LDPC codes, first proposed in and shown to be able to attain the full transmission diversity. We study the iterative threshold performance of those codes as a function of fading gains of the transmission channel and propose a numerical approximation of the iterative threshold versus fading gains, both both LDPC and Root-LDPC codes.Also, we show analytically that, in the case of 2 fading blocks,the iterative threshold root of Root-LDPC codes is proportional to (α1 α2)1, where α1 and α2 are corresponding fading gains.From this result, the full diversity property of Root-LDPC codes immediately follows.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Recommendations and laws do not always contain specific and clear provisions on the use of cadaveric material in research, and even more rarely do they address explicitly the ethical issues related to research on material obtained during forensic autopsy. In this article we analyse existing legal frameworks in Europe by comparing the legal provisions in 2 European Countries which are member states of the Council of Europe, the UK and Switzerland. They were chosen because they have distinct legal frameworks that make comparisons interesting. In addition, the detailed laws of the UK and a specific law project and national ethical recommendations in Switzerland permit us to define more clearly the legal range of options for researchers using cadaveric material obtained during forensic investigations. The Human Tissue Act 2004 in England, Wales and Northern Ireland, its Scottish equivalent with the same title (2006) and the national ethical guidelines in Switzerland all require consent from the deceased person, an appropriate relative or a person with power of attorney for healthcare decisions before cadaveric biological material can be obtained and used for research. However, if the purpose of the autopsy is purely forensic, no such authorization will be sought to carry out the autopsy and related analyses, which might include genetic testing. In order to be allowed to carry out future research projects, families need to be approached for informed consent, unless the deceased person had left written directives including permission to use his or her tissues for research.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

PURPOSE: To compare examination time with radiologist time and to measure radiation dose of computed tomographic (CT) fluoroscopy, conventional CT, and conventional fluoroscopy as guiding modalities for shoulder CT arthrography. MATERIALS AND METHODS: Glenohumeral injection of contrast material for CT arthrography was performed in 64 consecutive patients (mean age, 32 years; age range, 16-74 years) and was guided with CT fluoroscopy (n = 28), conventional CT (n = 14), or conventional fluoroscopy (n = 22). Room times (arthrography, room change, CT, and total examination times) and radiologist times (time the radiologist spent in the fluoroscopy or CT room) were measured. One-way analysis of variance and Bonferroni-Dunn posthoc tests were performed for comparison of mean times. Mean effective radiation dose was calculated for each method with examination data, phantom measurements, and standard software. RESULTS: Mean total examination time was 28.0 minutes for CT fluoroscopy, 28.6 minutes for conventional CT, and 29.4 minutes for conventional fluoroscopy; mean radiologist time was 9.9 minutes, 10.5 minutes, and 9.0 minutes, respectively. These differences were not statistically significant. Mean effective radiation dose was 0.0015 mSv for conventional fluoroscopy (mean, nine sections), 0.22 mSv for CT fluoroscopy (120 kV; 50 mA; mean, 15 sections), and 0.96 mSv for conventional CT (140 kV; 240 mA; mean, six sections). Effective radiation dose can be reduced to 0.18 mSv for conventional CT by changing imaging parameters to 120 kV and 100 mA. Mean effective radiation dose of the diagnostic CT arthrographic examination (140 kV; 240 mA; mean, 25 sections) was 2.4 mSv. CONCLUSION: CT fluoroscopy and conventional CT are valuable alternative modalities for glenohumeral CT arthrography, as examination and radiologist times are not significantly different. CT guidance requires a greater radiation dose than does conventional fluoroscopy, but with adequate parameters CT guidance constitutes approximately 8% of the radiation dose.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

ABSTRACT: In sexual assault cases, autosomal DNA analysis of gynecological swabs is a challenge, as the presence of a large quantity of female material may prevent the detection of the male DNA. A solution to this problem is differential DNA extraction, but as there are different protocols, it was decided to test their efficiency on simulated casework samples. Four difficult samples were sent to the nine Swiss laboratories active in the forensic genetics. They used their routine protocols to separate the epithelial cell fraction, enriched with the non-sperm DNA, from the sperm fraction. DNA extracts were then sent to the organizing laboratory for analysis. Estimates of male to female DNA ratio without differential DNA extraction ranged from 1:38 to 1:339, depending on the semen used to prepare the samples. After differential DNA extraction, most of the ratios ranged from 1:12 to 9:1, allowing the detection of the male DNA. Compared to direct DNA extraction, cell separation resulted in losses of 94-98% of the male DNA. As expected, more male DNA was generally present in the sperm than in the epithelial cell fraction. However, for about 30% of the samples, the reverse trend was observed. The recovery of male and female DNA was highly variable depending on the laboratories. Experimental design similar to the one used in this study may help for local protocol testing and improvement.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVEAnalysing the concepts of Continuous Health Education - CHE (EPS - in Portuguese), operated by municipal managers and translated into official documents.METHODQualitative research with the use of official documents and semi-structured interviews with the Municipal Health Secretaries or Coordinators of Primary Health Care in the Northeast Region of São Paulo State, and thematic analysis of empirical material.RESULTSResults indicate difficulties in the municipalities problematizing their management practices, services and health care; EPS tools presented are insufficient and unsatisfactory for amending the array of problems raised and are still far from the routine of Primary Care services.CONCLUSIONDespite efforts to implement EPS actions for the strengthening of primary care, the process appears to be incipient.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Differences in physico-chemical characteristics of bone grafts to fill bone defects have been demonstrated to influence in vitro bacterial biofilm formation. Aim of the study was to investigate in vivo staphylococcal biofilm formation on different calcium phosphate bone substitutes. A foreign-body guinea-pig infection model was used. Teflon cages prefilled with β-tricalcium phosphate, calcium-deficient hydroxyapatite, or dicalcium phosphate (DCP) scaffold were implanted subcutaneously. Scaffolds were infected with 2 × 10(3) colony-forming unit of Staphylococcus aureus (two strains) or S. epidermidis and explanted after 3, 24 or 72 h of biofilm formation. Quantitative and qualitative biofilm analysis was performed by sonication followed by viable counts, and microcalorimetry, respectively. Independently of the material, S. aureus formed increasing amounts of biofilm on the surface of all scaffolds over time as determined by both methods. For S. epidermidis, the biofilm amount decreased over time, and no biofilm was detected by microcalorimetry on the DCP scaffolds after 72 h of infection. However, when using a higher S. epidermidis inoculum, increasing amounts of biofilm were formed on all scaffolds as determined by microcalorimetry. No significant variation in staphylococcal in vivo biofilm formation was observed between the different materials tested. This study highlights the importance of in vivo studies, in addition to in vitro studies, when investigating biofilm formation of bone grafts.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The use of cages of different material and shapes for cervical discectomy with fusion (ACDF) has increased during the last few years. The use of additional osteogenic material is controversial. We prospectively evaluated an empty, Plasmapore-covered titanium cage (PCTC) in 45 patients undergoing 58 ACDFs. Patients were evaluated using standard clinical and radiological criteria. Good to excellent outcome was achieved in 93%, 78% and 75% after 3, 12 and 48 months, respectively. Sixty-five percent of patients could resume their prior work after 48 months. Disc space height and lordosis could be preserved in all cases. Two percent of the treated levels showed subsidence and 2% increased segmental motion. There were no procedure-related complications. Implantation of an empty PCTC after microsurgical anterior cervical discectomy is a safe procedure with good results and low incidence of complications. Disc height and lordosis can be preserved with low incidence of subsidence and good fusion rates.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A catalogue of the family Nycteribiidae (Diptera, Hippoboscoidea) of the New World is presented. Two genera and 52 species are listed in alphabetical order. Each genus account lists synonymies and type species, and each species account lists type locality and host, disposition of type material, geographic and host distribution, and a detailed bibliography.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

PURPOSE: To assess the value of adding axial traction to direct MR arthrography of the shoulder, in terms of subacromial and glenohumeral joint space widths, and coverage of the superior labrum-biceps tendon complex and articular cartilage by contrast material. MATERIALS AND METHODS: Twenty-one patients investigated by direct MR arthrography of the shoulder were prospectively included. Studies were performed with a 3 Tesla (T) unit and included a three-dimensional isotropic fat-suppressed T1-weighted gradient-recalled echo sequence, without and with axial traction (4 kg). Two radiologists independently measured the width of the subacromial, superior, and inferior glenohumeral joint spaces. They subsequently rated the amount of contrast material around the superior labrum-biceps tendon complex and between glenohumeral cartilage surfaces, using a three-point scale: 0 = no, 1 = partial, 2 = full. RESULTS: Under traction, the subacromial (Δ = 2.0 mm, P = 0.0003), superior (Δ = 0.7 mm, P = 0.0001) and inferior (Δ = 1.4 mm, P = 0.0006) glenohumeral joint space widths were all significantly increased, and both readers noted significantly more contrast material around the superior labrum-biceps tendon complex (P = 0.014), and between the superior (P = 0.001) and inferior (P = 0.025) glenohumeral cartilage surfaces. CONCLUSION: Direct MR arthrography of the shoulder under axial traction increases subacromial and glenohumeral joint space widths, and prompts better coverage of the superior labrum-biceps tendon complex and articular cartilage by contrast material. J. Magn. Reson. Imaging 2013;37:1228-1233. © 2012 Wiley Periodicals, Inc.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The genus Stylogaster Macquart (Diptera, Conopidae) is represented by 14 species in the Afrotropical region, five of them endemic to Madagascar and two recorded from South Africa, one of them endemic. Fifteen specimens of Muscidae, 14 from Madagascar and one from South Africa, belonging to 10 species, impaled with Stylogaster eggs were examined. Among them, three new muscid host species were found. The dissected eggs were all similar, suggesting the presence of the same species in both localities, what is not recorded until now. The available data on the dipteran Stylogaster eggs hosts in Africa is summarized. Color photos of the material examined are presented.