983 resultados para Cone-bean computed tomography
Resumo:
The aim of this study was to evaluate and compare organ doses delivered to patients in wrist and petrous bone examinations using a multislice spiral computed tomography (CT) and a C-arm cone-beam CT equipped with a flat-panel detector (XperCT). For this purpose, doses to the target organ, i.e. wrist or petrous bone, together with those to the most radiosensitive nearby organs, i.e. thyroid and eye lens, were measured and compared. Furthermore, image quality was compared for both imaging systems and different acquisition modes using a Catphan phantom. Results show that both systems guarantee adequate accuracy for diagnostic purposes for wrist and petrous bone examinations. Compared with the CT scanner, the XperCT system slightly reduces the dose to target organs and shortens the overall duration of the wrist examination. In addition, using the XperCT enables a reduction of the dose to the eye lens during head scans (skull base and ear examinations).
Resumo:
Fractures or the medial wall of the orbit are uncommon and clinical signs are often discreet. This report was focused on isolated fractures of the medial wall of the orbit. Blow-out trauma is usually the cause. In these cases the clinical signs ranged from simple ecchymosis to blindness by haematoma of the orbital cone. Computed tomography is a major tool for diagnosis and making therapeutic indications for these fractures. Treatment depends on the oculomotor involvements as measured by forced duction tests.
Resumo:
OBJECTIVE: To systematically review and meta-analyze published data about the diagnostic performance of Fluorine-18-Fluorodeoxyglucose ((18)F-FDG) positron emission tomography (PET) and PET/computed tomography (PET/CT) in the assessment of pleural abnormalities in cancer patients. METHODS: A comprehensive literature search of studies published through June 2013 regarding the role of (18)F-FDG-PET and PET/CT in evaluating pleural abnormalities in cancer patients was performed. All retrieved studies were reviewed and qualitatively analyzed. Pooled sensitivity, specificity, positive and negative likelihood ratio (LR+ and LR-) and diagnostic odd ratio (DOR) of (18)F-FDG-PET or PET/CT on a per patient-based analysis were calculated. The area under the summary ROC curve (AUC) was calculated to measure the accuracy of these methods in the assessment of pleural abnormalities. Sub-analyses considering (18)F-FDG-PET/CT and patients with lung cancer only were carried out. RESULTS: Eight studies comprising 360 cancer patients (323 with lung cancer) were included. The meta-analysis of these selected studies provided the following results: sensitivity 86% [95% confidence interval (95%CI): 80-91%], specificity 80% [95%CI: 73-85%], LR+ 3.7 [95%CI: 2.8-4.9], LR- 0.18 [95%CI: 0.09-0.34], DOR 27 [95%CI: 13-56]. The AUC was 0.907. No significant improvement considering PET/CT studies only and patients with lung cancer was found. CONCLUSIONS: (18)F-FDG-PET and PET/CT demonstrated to be useful diagnostic imaging methods in the assessment of pleural abnormalities in cancer patients, nevertheless possible sources of false-negative and false-positive results should be kept in mind. The literature focusing on the use of (18)F-FDG-PET and PET/CT in this setting remains still limited and prospective studies are needed.
Resumo:
Preoperative imaging for resection of chest wall malignancies is generally performed by computed tomography (CT). We evaluated the role of (18)F-fluorodeoxyglucose (FDG) positron emission tomography (PET) in planning full-thickness chest wall resections for malignancies. We retrospectively included 18 consecutive patients operated from 2004 to 2006 at our institution. Tumor extent was measured by CT and PET, using the two largest perpendicular tumor extensions in the chest wall plane to compute the tumor surface assuming an elliptical shape. Imaging measurements were compared to histopathology assessment of tumor borders. CT assessment consistently overestimated the tumor size as compared to PET (+64% vs. +1%, P<0.001). Moreover, PET was significantly better than CT at defining the size of lesions >24 cm(2) corresponding to a mean diameter >5.5 cm or an ellipse of >4 cm x 7.6 cm (positive predictive value 80% vs. 44% and specificity 93% vs. 64%, respectively). Metabolic PET imaging was superior to CT for defining the extent of chest wall tumors, particularly for tumors with a diameter >5.5 cm. PET can complement CT in planning full-thickness chest wall resection for malignancies, but its true value remains to be determined in larger, prospective studies.
Resumo:
Positron emission computed tomography (PET) is a functional, noninvasive method for imaging regional metabolic processes that is nowadays most often combined to morphological imaging with computed tomography (CT). Its use is based on the well-founded assumption that metabolic changes occur earlier in tumors than morphologic changes, adding another dimension to imaging. This article will review the established and investigational indications and radiopharmaceuticals for PET/CT imaging for prostate cancer, bladder cancer and testicular cancer, before presenting upcoming applications in radiation therapy.
Resumo:
ABSTRACTObjective:the study has the intention of evaluate the accuracy of computed tomography for the diagnosis of cervical lesions on penetrating neck trauma and also identify the most frequent mechanisms of trauma. Most injured structures, determine the age range and the most prevalent sex.Methods: observational descriptive retrospective study executed by the systematic retrospective review of medical records of all patients victims of penetrating neck trauma that went through surgery and CT scans, admitted into Hospital do Trabalhador, between January 2009 and December 2013.Results:the final sample was of 30 patients, 96.7% of the male sex, the median age was of 28 years old. Most patients suffered injuries by gun (56.7%) and 33,3% suffered stab wounds. The most stricken area of the neck was Zone II (77.8%) and the left side (55.2%). Regarding the structures injured, the CT showed 6.7% lesions on airways but the surgery showed 40% of damaged, with a value of p=0.002. As to damages of the esophagus and pharynx the CT detected 10% of lesions, while surgery found 30% of lesions, therefore with a significant value of p=0.013. As for the analysis the CT showed reliable. As for the analysis of vascular damage, the CT showed to be, in most cases, reliable to the findings during the surgical act.Conclusion:besides the great use of CT for the diagnosis of penetrating neck injuries we can say that this is an exam with low accuracy for the diagnosis of lesions of aerodigestive tract, therefore it is important a clinical correlation for a good diagnosis.as for the vascular lesions and of other structures, the CT had high sensibility and specificity, thus a good exam to be used in overall.
Resumo:
Objective: to assess the prevalence of abnormalities found by computed tomography (CT) of the chest in patients with squamous cell carcinoma of the head and neck. Methods: we retrospectively analyzed chest CT exams of 209 patients with squamous cell carcinoma of the head and neck. The CT findings were stratified as inflammatory / infectious, parenchymal, nodular uncharacteristic and nodular metastatic / tumoral Results: alterations were diagnosed in 66.6% of patients. Of these, 25.3% represented emphysema; 18.8%, uncharacteristic micronodules; 12.9%, metastases; 11.9%, thoracic lymph node enlargements; and in 6.6% we detected active pulmonary tuberculosis or its sequelae, pneumonia or inflammatory / infectious signs and pleural thickening or effusion. Conclusion: the prevalence of exams with alterations and the considerable rate of detected metastases indicate that chest CT should be required for diagnostic and / or staging in cases of head and neck cancer.
Resumo:
Coronary artery disease is an atherosclerotic disease, which leads to narrowing of coronary arteries, deteriorated myocardial blood flow and myocardial ischaemia. In acute myocardial infarction, a prolonged period of myocardial ischaemia leads to myocardial necrosis. Necrotic myocardium is replaced with scar tissue. Myocardial infarction results in various changes in cardiac structure and function over time that results in “adverse remodelling”. This remodelling may result in a progressive worsening of cardiac function and development of chronic heart failure. In this thesis, we developed and validated three different large animal models of coronary artery disease, myocardial ischaemia and infarction for translational studies. In the first study the coronary artery disease model had both induced diabetes and hypercholesterolemia. In the second study myocardial ischaemia and infarction were caused by a surgical method and in the third study by catheterisation. For model characterisation, we used non-invasive positron emission tomography (PET) methods for measurement of myocardial perfusion, oxidative metabolism and glucose utilisation. Additionally, cardiac function was measured by echocardiography and computed tomography. To study the metabolic changes that occur during atherosclerosis, a hypercholesterolemic and diabetic model was used with [18F] fluorodeoxyglucose ([18F]FDG) PET-imaging technology. Coronary occlusion models were used to evaluate metabolic and structural changes in the heart and the cardioprotective effects of levosimendan during post-infarction cardiac remodelling. Large animal models were used in testing of novel radiopharmaceuticals for myocardial perfusion imaging. In the coronary artery disease model, we observed atherosclerotic lesions that were associated with focally increased [18F]FDG uptake. In heart failure models, chronic myocardial infarction led to the worsening of systolic function, cardiac remodelling and decreased efficiency of cardiac pumping function. Levosimendan therapy reduced post-infarction myocardial infarct size and improved cardiac function. The novel 68Ga-labeled radiopharmaceuticals tested in this study were not successful for the determination of myocardial blood flow. In conclusion, diabetes and hypercholesterolemia lead to the development of early phase atherosclerotic lesions. Coronary artery occlusion produced considerable myocardial ischaemia and later infarction following myocardial remodelling. The experimental models evaluated in these studies will enable further studies concerning disease mechanisms, new radiopharmaceuticals and interventions in coronary artery disease and heart failure.
Resumo:
X-ray computed log tomography has always been applied for qualitative reconstructions. In most cases, a series of consecutive slices of the timber are scanned to estimate the 3D image reconstruction of the entire log. However, the unexpected movement of the timber under study influences the quality of image reconstruction since the position and orientation of some scanned slices can be incorrectly estimated. In addition, the reconstruction time remains a significant challenge for practical applications. The present study investigates the possibility to employ modern physics engines for the problem of estimating the position of a moving rigid body and its scanned slices which are subject to X-ray computed tomography. The current work includes implementations of the extended Kalman filter and an algebraic reconstruction method for fan-bean computer tomography. In addition, modern techniques such as NVidia PhysX and CUDA are used in current study. As the result, it is numerically shown that it is possible to apply the extended Kalman filter together with a real-time physics engine, known as PhysX, in order to determine the position of a moving object. It is shown that the position of the rigid body can be determined based only on reconstructions of its slices. However, the simulation of the body movement sometimes is subject to an error during Kalman filter employment as PhysX is not always able to continue simulating the movement properly because of incorrect state estimation.
Resumo:
We examine the efficacy two volume spatial registration of pre and postoperative clinical computed tomography (CT) imaging to verify post-operative electrode array placement in cochlear implant (CI) patients. To measure the degree of accuracy with which the composite image predicts in-vivo placement of the array, we replicate the CI surgical process in cadaver heads. Pre-operative, post-operative, micro CT imaging and histology are utilized for verification.
Resumo:
Micro-computed tomography (μCT) has been successfully used to study the cardiovascular system of mouse embryos in situ. With the use of barium as a suitable contrast agent, blood vessels have been imaged and analysed quantitatively such as blood volume and vessel sizes on embryos of ages 14.5 to 16.5 days old. The advantage of using this imaging modality is that it has provided three dimensional information whilst leaving samples intact for further study.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
The mature dentinoenamel junction (DEJ) is viewed by some investigators and the current authors, not as a fossilized, sharp transition between enamel and dentin, but as a relatively broad structural transition zone including the mantle dentin and the inner aprismatic enamel. In this study, the DEJ structure in bovine incisors was studied with synchrotron microComputed Tomography (microCT) using small cubes cut parallel to the tooth surface. The reconstructions revealed a zone of highly variable punctate contrast between bulk dentin and enamel; the mean linear attenuation coefficients and their standard deviations demonstrated that this zone averaged less mineral than dentin or enamel but had more highly variable structure than either. The region with the punctuate contrast is, therefore, the mantle dentin. The thickness of the mantle dentin seen in a typical data set was about 30 mu m, and the mantle dentin-enamel interface deviated +/- 15 mu m from the average plane over a distance of 520 mu m. In the highest resolution data (similar to 1.5 mu m isotropic voxels, volume elements), tubules in the dentin could be discerned in the vicinity of the DEJ. Contrast sensitivity was high enough to detect differences in mineral content between near-surface and near-DEJ volumes of the enamel. Reconstructions before and after two cubes were compressed to failure revealed cracks formed only in the enamel and did not propagate across the mantle dentin, regardless of whether loading was parallel to or perpendicular to the DEJ. (C) 2007 Elsevier B.V. All rights reserved.
Resumo:
Objective: Since blood viscosity (BV) is one of the most important factors determining blood flow, this study aimed to investigate the possible correlation between increased blood viscosity and reduction of regional cerebral blood flow (rCBF) in healthy ageing.Methods: Male subjects were distributed in two groups: "young", aged 20-30 (27 volunteers), or "elderly", aged 60-70 (50 volunteers). Whole blood viscosity was obtained with a Wells-Brookfield Cone/Plate Viscometer. Cerebral blood flow was analysed by means of single photon emission computed tomography (SPECT).Results: The mean BV values were 3.28 +/- 0.43 mPa in the group of young volunteers and 4.33 +/- 0.73 mPa in the group of elderly volunteers (t = -6.9, p < 0.0001). The elderly had a lower blood flow than the young in the following regions: bilateral parietal; temporal-parietal and temporal of the left hemisphere. Pearson's correlation between BV and rCBF showed a good inverse correlation when the BV was above 3.95 +/- 0.83 mPa.Conclusions: Our results point to a close relationship between the two parameters analysed, BV and rCBF. The impairment in rCBF observed in the elderly volunteers might be due to an increase in BV, among other factors.Significance: These findings suggest interesting possibilities for the treatment/prevention of brain ageing. (C) 2011 International Federation of Clinical Neurophysiology. Published by Elsevier B.V. All rights reserved.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)