983 resultados para Catheter ablation
Recoleta uterina como estratégia para aumentar a taxa de embriões em fêmeas bovinas de corte e leite
Resumo:
Embryo recovery rate in superovulated cows after uterine flushing is lower than the ovulation rate, which contributes to the relative inefficiency of the conventional cervical recovery procedure. A simple and easy alternative to improve embryo recovery rate is the uterine re-flushing procedure. To evaluate the effect of re-flushing and the influence of breed and operator on bovine embryo recovery rate, 38 Nelore and 19 Jersey females were stimulated using FSH, with embryos being collected by one of two trained operators. At the end of flushing, the catheter was sealed and maintained into the uterine body, filled with flushing medium, while females were released to a paddock for 30 to 50 min, to be submitted to the re-flushing procedure by the same operator. A total of 599 structures were recovered out of 57 procedures, from which 423 (70.6%) were obtained in the first flushing and 176 (29.4%) after re-flushing. Mean recovery rates of 7.4 and 3.1 structures were obtained after the first and second flushing, respectively, for a total of 10.5 structures per cow. Structures were obtained in 73.6% ( 42 out of 57) of the re-flushing procedures. No breed effect was observed on total ova or embryo recovery, with 10.9 total ova collected from Jersey and 10.3 from Nelore females. Likewise, the embryo recovery rate obtained following uterine flushing or re-flushing did not differ either between Jersey (8.1 and 2.7) and Nelore (7.0 and 3.2) animals, or between operators A (7.5 and 3.3) and B (7.3 and 2.9), respectively. In conclusion, the uterine re-flushing procedure significantly increased the rate of embryo recovery in Jersey and Nelore females, with no operator influence being observed.
Resumo:
Objective: The objective of this study was to evaluate the influence of different Er:YAG laser (lambda = 2.94 mu m) energy parameters on the microtensile bond strength (mu TBS) and superficial morphology of bovine enamel bleached with 16% carbamide peroxide. Background: Laser irradiation could improve adhesion to bleached enamel surfaces. Methods: Sixty bovine enamel blocks (7x3x3 mm(3)) were randomly assigned to six groups according to enamel preparation procedures (n = 10): G1-bleaching and Er:YAG laser irradiation with 25.52 J/cm(2) (laser A, LA); G2-bleaching and Er:YAG laser irradiation with 4.42J/cm(2) (laser B, LB); G3-bleaching; G4-Er:YAG laser irradiation with 25.52 J/cm(2); G5-Er:YAG laser irradiation with 4.42J/cm(2); G6-control, no treatment. G1 to G3 were bleached for 6 h during 21 days. Afterwards, enamel surfaces in all groups were slightly abraded with 600-grit SiC papers and G1, G2, G4 and G5 were irradiated according to each protocol. Enamel blocks were then restored with an etch-and-rinse adhesive system and a 4-mm thick composite buildup was made in two increments (n = 9). After 24 h, restored blocks were serially sectioned with a cross-section area of similar to 1 mm(2) at the bonded interface and tested in tension in a universal testing machine (1 mm/min). Failure mode was determined at a magnification of x100 using a stereomicroscope. One treated block of each group was selected for scanning electron microscopy (SEM) analysis. mu TBS data were analyzed by two-way ANOVA and no statistical differences were observed among groups. Results: Mean bond strengths (SD) in MPa were: G1-30.4(6.2); G2-27.9(8.5); G3-32.3(3.9); G4-23.7(5.8); G5-29.3(6.0); G6-29.1(6.1). A large number of adhesive failures was recorded for bleached and irradiated enamel surfaces. Conclusions: Bleached enamel surfaces mu TBS values were not significantly different from those of unbleached enamel. Even though Er:YAG laser irradiation with both parameters had no influence on mu TBS for bleached and unbleached enamel, SEM analysis revealed that Er:YAG laser irradiation with 25.52J/cm(2) should not be recommended, as enamel ablation was observed, whereas irradiation with 4.42J/cm(2) did not promote any remarkable changes on enamel surface.
Resumo:
Objective: The aim of the present study was to compare the in vitro effects of the Er:YAG laser, an ultrasonic system, and manual curette on dentine root surface by roughness and micro-morphological analysis. Materials and Methods: Thirty-six flattened bovine roots were randomly assigned to one of the following groups: group 1 (n = 12): Er: YAG laser ( 2940 nm), 120 mJ/pulse, 10 Hz, 8.4 J/cm(2); group 2 ( n = 12): ultrasonic system; and group 3 ( n = 12): manual curette. The mean surface roughness (Ra) of each sample was measured using a profilometer before and after the treatments. The micro-morphology of the treated and untreated ( control) root surfaces was evaluated with scanning electron microscopy (SEM) at 50 x and 1000 x magnification. Results: Analysis with the profilometer showed that for equal times of instrumentation, the smoothest surfaces were produced by the Er: YAG laser and the ultrasonic system, followed by the curette ( p < 0.05). Morphological analyses demonstrated that treatment with the Er: YAG laser produced some areas with an irregular surface, craters, and ablation of the intertubular dentin. The smear layer was removed and dentine tubules were opened by both curettes and the ultrasonic system. The micro-morphology of the dentine root surface after ultrasonic treatment, however, demonstrated randomly distributed areas cratering. Conclusion: All instruments increased the roughness of the dentine root surface after treatment; however, the curette produced rougher surfaces than the other devices. SEM analysis revealed distinct root surface profiles produced by the three devices.
Resumo:
Herpes simplex virus (HSV) is one of the most common viral infections of the human being. Although most of the seropositive persons do not manifest symptoms, infected individuals may present recurrent infections, characterized by cold sores. HSV-1 infection can result in potentially harmful complications in some patients, especially in those with compromised immunity. We report a clinical case of a patient with severe oral HSV-1 infection in the lower lip. The treatment of the lesions with the association of high-intensity (erbium-doped yttrium aluminum garnet, 2.94 mu m, 80 mJ/pulse, 2-4 Hz) and low-intensity (indium gallium aluminum phosphide, 660 nm, 3.8 J/cm(2), 10mW) lasers has not been reported in the literature. During treatment, no systemic or topical medication was used. Pain sensitivity was completely gone after the first irradiation with the low-intensity laser. During the healing process, lesions were traumatized twice, on the days 4 and 7. Even though the lesions were completely healed within 10 days.
Resumo:
Objective: The purpose of this study was to assess the efficacy of Er:YAG laser energy for composite resin removal and the influence of pulse repetition rate on the thermal alterations occurring during laser ablation. Materials and Methods: Composite resin filling was placed in cavities (1.0 mm deep) prepared in bovine teeth and the specimens were randomly assigned to five groups according to the technique used for composite filling removal. In group I (controls), the restorations were removed using a high-speed diamond bur. In the other groups, the composite fillings were removed using an Er: YAG laser with different pulse repetition rates: group 2-2 Hz; group 3-4 Hz; group 4-6 Hz; and group 5-10 Hz. The time required for complete removal of the restorative material and the temperature changes were recorded. Results: Temperature rise during composite resin removal with the Er: YAG laser occurred in the substrate underneath the restoration and was directly proportional to the increase in pulse repetition rate. None of the groups had a temperature increase during composite filling removal of more than 5.6 degrees C, which is considered the critical point above which irreversible thermal damage to the pulp may result. Regarding the time for composite filling removal, all the laser-ablated groups (except for group 5 [10 Hz]) required more time than the control group for complete elimination of the material from the cavity walls. Conclusion: Under the tested conditions, Er: YAG laser irradiation was efficient for composite resin ablation and did not cause a temperature increase above the limit considered safe for the pulp. Among the tested pulse repetition rates, 6 Hz produced minimal temperature change compared to the control group (high-speed bur), and allowed composite filling removal within a time period that is acceptable for clinical conditions.
Resumo:
Introduction: The occurrence of urolithiasis in pregnancy represents a challenge in both diagnosis and treatment of this condition, because it presents risks not only to the mother but also to the fetus. Surgical treatment may be indicated for patients with infection, persistent pain, and obstruction of a solitary kidney. We present our experience on the management of pregnant patients with ureteral calculi and a review of the literature. Materials and Methods: The charts of 19 pregnant patients with obstructive ureteral calculi were retrospectively reviewed. Gestational age ranged from 13 to 33 weeks. In all patients, ureteral stone was diagnosed on abdominal ultrasound. In regard to localization, 15 calculi were in the distal ureter, 3 in the proximal ureter, and 1 in the interior of an ureterocele. Calculi size ranged from 6 to 10 mm (mean, 8 mm). The following criteria were used to indicate ureteroscopy: persistent pain with no improvement after clinical treatment, increase in renal dilation, or presence of uterine contractions. Nine patients (47.3%) were submitted to ureteroscopy. All calculi (100%) were removed with a stone basket extractor under continuous endoscopic vision. None of the calculi demanded the use of a lithotriptor. Results: Nine patients (47.3%) treated with clinical measurements presented no obstetric complications and spontaneous elimination of the calculi. Nine patients (47.3%) submitted to ureteroscopy had no surgical complications. There was remission of pain in all cases after ureteroscopy and ureteral catheter placement. Conclusion: The diagnosis and treatment of ureteral lithiasis in pregnant women present potential risks for the fetus and the mother. Conservative management is the first option, but ureteroscopy may be performed with safety and high success rates.
Resumo:
Objective: The aim of this study was to assess by atomic force microscopy (AFM) the effect of Er,Cr:YSGG laser application on the surface microtopography of radicular dentin. Background: Lasers have been used for various purposes in dentistry, where they are clinically effective when used in an appropriate manner. The Er, Cr: YSGG laser can be used for caries prevention when settings are below the ablation threshold. Materials and Methods: Four specimens of bovine dentin were irradiated using an Er, Cr:YSGG laser (lambda = 2.78 mu m), at a repetition rate of 20 Hz, with a 750-mu m-diameter sapphire tip and energy density of 2.8 J/cm(2) (12.5 mJ/pulse). After irradiation, surface topography was analyzed by AFM using a Si probe in tapping mode. Quantitative and qualitative information concerning the arithmetic average roughness (Ra) and power spectral density analyses were obtained from central, intermediate, and peripheral areas of laser pulses and compared with data from nonirradiated samples. Results: Dentin Ra for different areas were as follows: central, 261.26 (+/- 21.65) nm; intermediate, 83.48 (+/- 6.34) nm; peripheral, 45.8 (+/- 13.47) nm; and nonirradiated, 35.18 (+/- 2.9) nm. The central region of laser pulses presented higher ablation of intertubular dentin, with about 340-760 nm height, while intermediate, peripheral, and nonirradiated regions presented no difference in height of peritubular and interperitubular dentin. Conclusion: According to these results, we can assume that even when used at a low-energy density parameter, Er, Cr: YSGG laser can significantly alter the microtopography of radicular dentin, which is an important characteristic to be considered when laser is used for clinical applications.
Resumo:
It has been demonstrated that laser induced breakdown spectrometry (LIBS) can be used as an alternative method for the determination of macro (P, K. Ca, Mg) and micronutrients (B, Fe, Cu, Mn, Zn) in pellets of plant materials. However, information is required regarding the sample preparation for plant analysis by LIBS. In this work, methods involving cryogenic grinding and planetary ball milling were evaluated for leaves comminution before pellets preparation. The particle sizes were associated to chemical sample properties such as fiber and cellulose contents, as well as to pellets porosity and density. The pellets were ablated at 30 different sites by applying 25 laser pulses per site (Nd:YAG@1064 nm, 5 ns, 10 Hz, 25J cm(-2)). The plasma emission collected by lenses was directed through an optical fiber towards a high resolution echelle spectrometer equipped with an ICCD. Delay time and integration time gate were fixed at 2.0 and 4.5 mu s, respectively. Experiments carried out with pellets of sugarcane, orange tree and soy leaves showed a significant effect of the plant species for choosing the most appropriate grinding conditions. By using ball milling with agate materials, 20 min grinding for orange tree and soy, and 60 min for sugarcane leaves led to particle size distributions generally lower than 75 mu m. Cryogenic grinding yielded similar particle size distributions after 10 min for orange tree, 20 min for soy and 30 min for sugarcane leaves. There was up to 50% emission signal enhancement on LIBS measurements for most elements by improving particle size distribution and consequently the pellet porosity. (C) 2011 Elsevier B.V. All rights reserved.
Resumo:
Laser induced breakdown spectroscopy (LIBS) has been evaluated for the determination of micronutrients (B, Cu, Fe, Mn and Zn) in pellets of plant materials, using NIST, BCR and GBW biological certified reference materials for analytical calibration. Pellets of approximately 2 mm thick and 15 mm diameter were prepared by transferring 0.5 g of powdered material to a 15 mm die set and applying 8.0 tons cm(-2). An experimental setup was designed by using a Nd:YAG laser operating at 1064 nm (200 mJ per pulse, 10 Hz) and an Echelle spectrometer with ICCD detector. Repeatability precision varied from 4 to 30% from measurements obtained in 10 different positions (8 laser shots per test portion) in the same sample pellet. Limits of detection were appropriate for routine analysis of plant materials and were 2.2 mg kg(-1) B, 3.0 mg kg(-1) Cu, 3.6 mg kg(-1) Fe, 1.8 mg kg(-1) Mn and 1.2 mg kg(-1) Zn. Analysis of different plant samples were carried out by LIBS and results were compared with those obtained by ICP OES after wet acid decomposition. (C) 2009 Elsevier B.V. All rights reserved.
Resumo:
There are controversies about the use of local anesthetics during balloon compression for trigeminal neuralgia (TN) as a protective factor for cardiovascular events. The objective of this study was to investigate cardiovascular parameters (blood pressure and heart rate [HR]) of patients that underwent trigeminal balloon compression with local anesthetics compared to a control group (placebo). This is a randomized controlled study; 55 patients were randomized into two groups: study (deep sedation and trigeminal block with 0.8-mL lidocaine 2%) and control group (deep sedation and trigeminal injection of 0.8-mL saline). Blood pressure and HR were measured in five distinct moments: preoperative, during puncture for local anesthesia/placebo, during puncture with the catheter, during balloon compression, and final evaluation. Statistical analysis was performed with Pearson`s chi (2) and McNemar tests and the analysis of variance for repetitive measures. The means of systolic and diastolic blood pressures (SBP and DBP, respectively) were higher in the control group when compared to the study group at the evaluation during puncture with the catheter (p < 0.001) and balloon compression (p < 0.001 and p = 0.018 for DBP and SBP, respectively). There was an increase in the HR in the control group during the procedure (p = 0.017). The use of local anesthetics during the trigeminal balloon compression for TN can have a preventive role for the risk of cardiovascular events.
Resumo:
Governmental programmes should be developed to collect and analyse data on healthcare associated infections (HAIs). This study describes the healthcare setting and both the implementation and preliminary results of the Programme for Surveillance of Healthcare Associated Infections in the State of Sao Paulo (PSHAISP), Brazil, from 2004 to 2006. Characterisation of the healthcare settings was carried out using a national database. The PSHAISP was implemented using components for acute care hospitals (ACH) or long term care facilities (LTCF). The components for surveillance in ACHs were surgical unit, intensive care unit and high risk nursery. The infections included in the surveillance were surgical site infection in clean surgery, pneumonia, urinary tract infection and device-associated bloodstream infections. Regarding the LTCF component, pneumonia, scabies and gastroenteritis in all inpatients were reported. In the first year of the programme there were 457 participating healthcare settings, representing 51.1% of the hospitals registered in the national database. Data obtained in this study are the initial results and have already been used for education in both surveillance and the prevention of HAI. The results of the PSHAISP show that it is feasible to collect data from a large number of hospitals. This will assist the State of Sao Paulo in assessing the impact of interventions and in resource allocation. (C) 2010 The Hospital Infection Society. Published by Elsevier Ltd. All rights reserved.
Resumo:
Surface heat treatment in glasses and ceramics, using CO(2) lasers, has attracted the attention of several researchers around the world due to its impact in technological applications, such as lab-on-a-chip devices, diffraction gratings and microlenses. Microlens fabrication on a glass surface has been studied mainly due to its importance in optical devices (fiber coupling, CCD signal enhancement, etc). The goal of this work is to present a systematic study of the conditions for microlens fabrications, along with the viability of using microlens arrays, recorded on the glass surface, as bidimensional codes for product identification. This would allow the production of codes without any residues (like the fine powder generated by laser ablation) and resistance to an aggressive environment, such as sterilization processes. The microlens arrays were fabricated using a continuous wave CO(2) laser, focused on the surface of flat commercial soda-lime silicate glass substrates. The fabrication conditions were studied based on laser power, heating time and microlens profiles. A He-Ne laser was used as a light source in a qualitative experiment to test the viability of using the microlenses as bidimensional codes.
Resumo:
BACKGROUND: Guidelines for red blood cell (RBC) transfusions exist; however, transfusion practices vary among centers. This study aimed to analyze transfusion practices and the impact of patients and institutional characteristics on the indications of RBC transfusions in preterm infants. STUDY DESIGN AND METHODS: RBC transfusion practices were investigated in a multicenter prospective cohort of preterm infants with a birth weight of less than 1500 g born at eight public university neonatal intensive care units of the Brazilian Network on Neonatal Research. Variables associated with any RBC transfusions were analyzed by logistic regression analysis. RESULTS: Of 952 very-low-birth-weight infants, 532 (55.9%) received at least one RBC transfusion. The percentages of transfused neonates were 48.9, 54.5, 56.0, 61.2, 56.3, 47.8, 75.4, and 44.7%, respectively, for Centers 1 through 8. The number of transfusions during the first 28 days of life was higher in Center 4 and 7 than in other centers. After 28 days, the number of transfusions decreased, except for Center 7. Multivariate logistic regression analysis showed higher likelihood of transfusion in infants with late onset sepsis (odds ratio [OR], 2.8; 95% confidence interval [CI], 1.8-4.4), intraventricular hemorrhage (OR, 9.4; 95% CI, 3.3-26.8), intubation at birth (OR, 1.7; 95% CI, 1.0-2.8), need for umbilical catheter (OR, 2.4; 95% CI, 1.3-4.4), days on mechanical ventilation (OR, 1.1; 95% CI, 1.0-1.2), oxygen therapy (OR, 1.1; 95% CI, 1.0-1.1), parenteral nutrition (OR, 1.1; 95% CI, 1.0-1.1), and birth center (p < 0.001). CONCLUSIONS: The need of RBC transfusions in very-low-birth-weight preterm infants was associated with clinical conditions and birth center. The distribution of the number of transfusions during hospital stay may be used as a measure of neonatal care quality.
Resumo:
Balloon catheter injury results in hyper-reactivity to phenylephrine in contralateral carotids. Decreased nitric oxide (NO) modulation and/or increased intracellular calcium concentration triggers vascular smooth muscle contraction. Therefore, this study explores the participation of NO signaling pathway and calcium mobilization on hyper-reactivity to phenylephrine in contralateral carotids. Concentration-response curves for calcium (CaCl(2)) and phenylephrine were obtained in control and contralateral carotids four days after balloon injury, in the presence and absence of the inhibitors (L-NAME, L-NNA, 1400W, 7-NI, Oxyhemoglobin, ODQ or Tiron). Confocal microscopy using Fluo-3AM or DHE was performed to detect the intracellular levels of calcium and reactive oxygen species, respectively. The modulation of NO on phenylephrine-induced contraction was absent in the contralateral carotid. Phenylephrine-induced intracellular calcium mobilization was not altered in contralateral carotids. However, extracellular calcium mobilization by phenylephrine was reduced in the contralateral carotid compared to control arteries, and this result was confirmed by confocal microscopy. L-NAME increased phenylephrine-induced extracellular calcium mobilization in the contralateral carotid to the control levels. Results obtained with L-NNA, 1400W, 7-NI, OxyHb, ODQ or Tiron showed that this response was mediated by products from endothelial NOS (eNOS) different from NO and without soluble guanylate cyclase activation, but it involved superoxide anions. Furthermore. Tiron or L-NNA reduced the levels of reactive oxygen species in contralateral carotids. Data suggest that balloon catheter injury promoted eNOS uncoupling in contralateral carotids, which generates superoxide rather than NO, and reduces phenylephrine-induced extracellular calcium mobilization, despite the hyper-reactivity to phenylephrine in contralateral carotids. (C) 2010 Elsevier B.V. All rights reserved.
Resumo:
Balloon catheter injury promotes hyperreactivity to phenylephrine (Phe) in the contralateral carotid. Phe-induced contraction involves calcium mobilization, a process that may be sensitive to reactive oxygen species. In this study, we investigated whether increased reactivity to Phe in the contralateral carotid is due to alterations in calcium mobilization by Phe and reactive oxygen species signaling. Concentration-response curves to Phe were obtained in control and contralateral arteries 4 days after balloon injury. Tiron did not modify E(max) to Phe in control arteries but reduced this parameter in the contralateral carotid to control levels. Moreover, immunofluorescence to dihydroethydine showed increased basal oxidative stress in the contralateral artery compared with control artery. Intracellular calcium mobilization by Phe in the contralateral artery was not different from control, but Phe-induced extracellular calcium mobilization was reduced in the contralateral artery compared with that in the control. These data were confirmed by confocal microscopy using Fluo 3-AM. Tiron and SC-236 increased Phe-induced calcium influx in the contralateral artery, which was similar to controls in the same conditions. However, catalase did not modify this response. Taken together, our results suggest that superoxide anions and prostanoids from cyclooxygenase-2 alter pathways downstream of alpha(1)-adrenoceptor activation in the contralateral carotid in response to injury. This results in reduced Phe-induced calcium influx, despite hyperreactivity to Phe.