984 resultados para Catalysis by modified pillared clays
Resumo:
Purpose Antigen-specific suppression of a previously primed immune response is a major challenge for immunotherapy of autoimmune disease. We have shown that NF-κB inactivation in dendritic cells (modified DC) converts them into cells that tolerize rather than immunize to specific antigen [1]. Antigen-exposed modified DC prevent priming of immunity, and they suppress previously primed immune responses. Regulatory CD4+ T cells, which can transfer antigen-specific tolerance in an IL-10-dependent fashion, mediate the tolerance. We hypothesized that modified DC exposed to arthritogenic antigen would suppress clinical arthritis after disease onset. Methods Antigen-induced arthritis was induced in C57/Bl6 mice by priming to methylated bovine serum albumin (mBSA) antigen followed by challenge injection of mBSA to one knee. Knee swelling was apparent within 2 days, with peak clinical signs apparent at 5 days. Mice were treated with antigen-exposed modified DC between 2 and 6 days after mBSA challenge to the knee joint. Results Clinical arthritis was suppressed in each group receiving mBSA-exposed modified DC within 4 days compared with mice that received either no DC or keyhole limpet hemocyanin-exposed modified DC. Clinical improvement was associated with mBSA-specific tolerance in mice receiving mBSA-exposed modified DC. Tolerance induction was not impaired by concomitant administration of anti-tumor necrosis factor alpha monoclonal antibody. Subsequent rechallenge with intra-articular IL-1 induced flare of arthritis in all groups, which could be effectively suppressed by a second administration of mBSA-exposed modified DC. Conclusions The data indicate that modified DC induce antigen-specific immune suppression in this model of inflammatory arthritis, even after full clinical expression of the disease. These observations have important implications for antigen-specific therapy of autoimmunity.
Resumo:
Primidone (PRM) oxidation by various oxidants such as iodosylbenzene (PhIO), tert-butyl hydroperoxide 70wt.% (t-BOOH), 3-chloroperoxybenzoic acid (m-CPBA) and hydrogen peroxide 30wt.%, mediated by either a salen complex or metalloporphyrins, was investigated. The catalytic systems led to phenylethyl-malondiamide (PEMA) and phenobarbital (FEND), the same metabolites obtained in vivo with P450 enzymes, although three other products were also detected. Product formation was highly dependent on the oxidant, co-catalyst (imidazole), pH and dioxygen. These biomimetic chemical models have potential application in the synthesis of drug metabolites. which should provide samples for pharmacological tests. They can also be employed in studies that pursue the elucidation of in vivo drug metabolism. (C) 2008 Elsevier B.V. All rights reserved.
Resumo:
Self-assembled films from SnO2 and polyallylamine (PAH) were deposited on gold via ionic attraction by the layer-by-layer(LbL) method. The modified electrodes were immersed into a H2PtCl6 solution, a current of 100 mu A was applied, and different electrodeposition times were used. The SnO2/PAH layers served as templates to yield metallic platinum with different particle sizes. The scanning tunnel microscopy images show that the particle size increases as a function of electrodeposition time. The potentiodynamic profile of the electrodes changes as a function of the electrodeposition time in 0.5 mol L-1 H2SO4, at a sweeping rate of 50mVs(-1). Oxygen-like species are formed at less positive potentials for the Pt-SnO2/PAH film in the case of the smallest platinum particles. Electrochemical impedance spectroscopy measurements in acid medium at 0.7 V show that the charge transfer resistance normalized by the exposed platinum area is 750 times greater for platinum electrode (300 k Omega cm(2)) compared with the Pt-SnO2/PAH film with 1 min of electrodeposition (0.4 k Omega cm(2)). According to the Langmuir-Hinshelwood bifunctional mechanism, the high degree of coverage with oxygen-like species on the platinum nanoparticles is responsible for the electrocatalytic activity of the Pt-SnO2/PAH concerning ethanol electrooxidation. With these features, this Pt-SnO2/PAH film may be grown on a proton exchange membrane (PEM) in direct ethanol fuel cells (DEFC). (c) 2008 Elsevier B.V. All rights reserved.
Resumo:
A highly efficient two-step method for the synthesis of pyranoquinoline derivatives from imino-Diels-Alder reactions between aldimines and 3,4-dihydro-2H-pyran using niobium(V) chloride as catalyst under mild conditions is described.
Resumo:
Alcohols and acids can be switched to produce ethers or esters by varying the alcohol to catalyst mol ratio, in a new etherification and esterification method using NbCl5/Al2O3 catalyst under ""solvent free"" conditions and promoted by MW (microwave) irradiation. A ""two sites"" mechanism for the reaction is proposed, in an attempt to clarify the tendency of the catalyst to be dependent on the alcohol alone during the esterification process. (c) 2008 Elsevier B.V. All rights reserved.
Resumo:
This work describes the catalytic activity of manganese and iron porphyrins, Mn and Fe(TFPP)Cl, covalently immobilized on the aminofunctionalized supports montmorillonite K-10 (MontX) and silica (SilX), where X= 1 or 2 represents the length of the organic chain (""arms"") binding the metalloporphyrin to the support. These systems were characterized by UV-vis and Electronic Paramagnetic Resonance (EPR), and they were used as catalysts in the oxidation of carbamazepine (CBZ) by the oxidants iodosylbenzene (PhIO) and hydrogen peroxide. The manganese porphyrin (MnP) catalysts proved to be efficient and selective for the epoxide, the main CBZ metabolite in natural systems. MnMont1 was an excellent catalyst when PhIO was used as oxidant, even better than the same MnP in homogeneous system. Supports bearing short ""arms"" led to the best yields. Although H2O2 is an environmentally friendly oxidant, low product yields were obtained when it was employed in CBZ oxidation. Fe(TFPP)CI immobilized on aminofunctionalized supports was not an efficient catalyst, probably due to the presence of Fe(H) species in the matrix, which led to the less reactive intermediate PFe(IV)(O). (c) 2007 Elsevier B.V. All rights reserved.
Resumo:
An Adobe (R) animation is presented for use in undergraduate Biochemistry courses, illustrating the mechanism of Na(+) and K(+) translocation coupled to ATP hydrolysis by the (Na, K)-ATPase, a P(2c)-type ATPase, or ATP-powered ion pump that actively translocates cations across plasma membranes. The enzyme is also known as an E(1)/E(2)-ATPase as it undergoes conformational changes between the E(1) and E(2) forms during the pumping cycle, altering the affinity and accessibility of the transmembrane ion-binding sites. The animation is based on Horisberger`s scheme that incorporates the most recent significant findings to have improved our understanding of the (Na, K)-ATPase structure function relationship. The movements of the various domains within the (Na, K)-ATPase alpha-subunit illustrate the conformational changes that occur during Na(+) and K(+) translocation across the membrane and emphasize involvement of the actuator, nucleotide, and phosphorylation domains, that is, the ""core engine"" of the pump, with respect to ATP binding, cation transport, and ADP and P(i) release.
Resumo:
In this work, a fast, non destructive voltammetric method for cocaine detection in acetonitrile medium using a platinum disk electrode chemically modified with cobalt-hexacyanoferrate (CoHCFe) film is described. The deposition of CoHCFe film at platinum disk (working electrode) was carried out in aqueous solution containing NaClO(4) at 0.1 mol L(-1) as supporting electrolite. Stability studies of the film and subsequent voltammetric analysis of cocaine were made in acetonitrile medium with NaClO4 at 0.1 mol L(-1) as supporting electrolite. A reversible interaction between cocaine and CoHCFe at the film produces a proportional decrease of original peak current, due to the formation of a complex between cocaine and cobalt ions, with subsequent partial passivation of the film surface, being the intensity of current decrease used as analytical signal for cocaine. A linear dependence of cocaine detection was carried out in the range from 2.4 x 10 x 4 to 1.5 x 10(-3) mol L(-1), with a linear correlation coefficient of 0.994 and a detection limit of 1.4 x 10 x 4 mol L(-1). The analysis of confiscated samples by the proposed method indicated cocaine levels from 37% to 95% (m/m) and these results were validated by comparison to HPLC technique, being obtained good correlation between both methods. (C) 2009 Elsevier Ireland Ltd. All rights reserved.
Resumo:
Pollution by polycyclic aromatic hydrocarbons(PAHs) is widespread due to unsuitable disposal of industrial waste. They are mostly defined as priority pollutants by environmental protection authorities worldwide. Phenanthrene, a typical PAH, was selected as the target in this paper. The PAH-degrading mixed culture, named ZM, was collected from a petroleum contaminated river bed. This culture was injected into phenanthrene solutions at different concentrations to quantify the biodegradation process. Results show near-complete removal of phenanthrene in three days of biodegradation if the initial phenanthrene concentration is low. When the initial concentration is high, the removal rate is increased but 20%-40% of the phenanthrene remains at the end of the experiment. The biomass shows a peak on the third day due to the combined effects of microbial growth and decay. Another peak is evident for cases with a high initial concentration, possibly due to production of an intermediate metabolite. The pH generally decreased during biodegradation because of the production of organic acid. Two phenomenological models were designed to simulate the phenanthrene biodegradation and biomass growth. A relatively simple model that does not consider the intermediate metabolite and its inhibition of phenanthrene biodegradation cannot fit the observed data. A modified Monod model that considered an intermediate metabolite (organic acid) and its inhibiting reversal effect reasonably depicts the experimental results.
Resumo:
Context: 21-Hydroxylase deficiency (21OHD) is caused by CYP21A2 gene mutations disrupting the adrenal 21-hydroxylase, P450c21. CYP21A2 mutations generally correlate well with the 21OHD phenotype, but some children with severe CYP21A2 mutations have residual 21-hydroxylase activity. Some hepatic P450 enzymes can 21-hydroxylate progesterone, but their physiological relevance in modifying 21OHD is not known. Objective: Wedetermined the ability of CYP2C19 and CYP3A4 to 21-hydroxylate progesterone and 17-hydroxyprogesterone (17OHP), determined the impact of the common P450 oxidoreductase (POR) variant A503V on these activities, and examined correlations between CYP2C19 variants and phenotype in patients with 21OHD. Methods: Bacterially expressed, N-terminally modified, C-His-tagged human P450c21, CYP2C19, and CYP3A4 were combined with bacterially expressed wild-type and A503V POR. The 21-hydroxylation of radiolabeled progesterone and 17OHP was assessed, and the Michaelis constant (Km) and maximum velocity (Vmax) of the reactions were measured. CYP2C19 was genotyped in 21OHD patients with genotypes predicting severe congenital adrenal hyperplasia. Results: Compared to P450c21, the Vmax/Km for 21-hydroxylation of progesterone by CYP2C19 and CYP3A4 were 17 and 10%, respectively. With both forms of POR, the Km for P450c21 was approximately 2.6 mu M, the Km for CYP2C19 was approximately 11 mu M, and the Km for CYP3A4 was approximately 110 mu M. Neither CYP2C19 nor CYP3A4 could 21-hydroxylate 17OHP. The CYP2C19 ultrametabolizer allele CYP2C19* 17 was homozygous in one of five patients with a 21OHD phenotype that was milder than predicted by the CYP21A2 genotype. Conclusions: CYP2C19 and CYP3A4 can 21-hydroxylate progesterone but not 17OHP, possibly ameliorating mineralocorticoid deficiency, but not glucocorticoid deficiency. Multiple enzymes probably contribute to extraadrenal 21-hydroxylation. (J Clin Endocrinol Metab 94: 89-95, 2009)
Resumo:
Background: The accuracy of multidetector computed tomographic (CT) angiography involving 64 detectors has not been well established. Methods: We conducted a multicenter study to examine the accuracy of 64-row, 0.5-mm multidetector CT angiography as compared with conventional coronary angiography in patients with suspected coronary artery disease. Nine centers enrolled patients who underwent calcium scoring and multidetector CT angiography before conventional coronary angiography. In 291 patients with calcium scores of 600 or less, segments 1.5 mm or more in diameter were analyzed by means of CT and conventional angiography at independent core laboratories. Stenoses of 50% or more were considered obstructive. The area under the receiver-operating-characteristic curve (AUC) was used to evaluate diagnostic accuracy relative to that of conventional angiography and subsequent revascularization status, whereas disease severity was assessed with the use of the modified Duke Coronary Artery Disease Index. Results: A total of 56% of patients had obstructive coronary artery disease. The patient-based diagnostic accuracy of quantitative CT angiography for detecting or ruling out stenoses of 50% or more according to conventional angiography revealed an AUC of 0.93 (95% confidence interval [CI], 0.90 to 0.96), with a sensitivity of 85% (95% CI, 79 to 90), a specificity of 90% (95% CI, 83 to 94), a positive predictive value of 91% (95% CI, 86 to 95), and a negative predictive value of 83% (95% CI, 75 to 89). CT angiography was similar to conventional angiography in its ability to identify patients who subsequently underwent revascularization: the AUC was 0.84 (95% CI, 0.79 to 0.88) for multidetector CT angiography and 0.82 (95% CI, 0.77 to 0.86) for conventional angiography. A per-vessel analysis of 866 vessels yielded an AUC of 0.91 (95% CI, 0.88 to 0.93). Disease severity ascertained by CT and conventional angiography was well correlated (r=0.81; 95% CI, 0.76 to 0.84). Two patients had important reactions to contrast medium after CT angiography. Conclusions: Multidetector CT angiography accurately identifies the presence and severity of obstructive coronary artery disease and subsequent revascularization in symptomatic patients. The negative and positive predictive values indicate that multidetector CT angiography cannot replace conventional coronary angiography at present. (ClinicalTrials.gov number, NCT00738218.).
Resumo:
PURPOSE: To determine whether implantation of an intraocular lens (IOL) with an aspheric surface (Akreos AO, Bausch & Lomb Inc) results in reduced ocular aberrations (spherical aberration) and improved Strehl ratio and modulation transfer function (MTF) after cataract surgery. METHODS: In an intraindividual, randomized, double-masked, prospective study of 50 eyes (25 patients) with bilateral cataract, an IOL with modified anterior and posterior surfaces (Akreos AO) was implanted in one eye and a biconvex IOL with spherical surfaces (Akreos Fit, Bausch & Lomb Inc) implanted in the fellow eye. Ocular aberrations, Strehl ratio, and MTF curve with 4.5-, 5.0-, and 6.0-mm pupils were measured with a NIDEK OPD-Scan dynamic retinoscopy aberrometer 3 months after surgery. Uncorrected and corrected distance visual acuity (UDVA and CDVA, respectively) were also measured. RESULTS: No statistically significant difference was noted between eyes in postoperative UDVA and CDVA at 1 month. At 3 months, the Akreos AO IOL group obtained statistically significant lower values of higher order and spherical aberrations with 4.5-, 5.0-, and 6.0-mm pupil diameters than the Akreos Fit IOL group (P<.05). The value of Strehl ratio was statistically significantly higher in eyes with the Akreos AO IOL for 4.5- and 6.0-mm pupils (P<.05). The MTF curve was better in the Akreos AO IOL group in 4.5-, 5.0-, and 6.0-mm pupils (P<.05). CONCLUSIONS: The aspheric Akreos AO IOL induced significantly less spherical aberration than the Akreos Fit IOL for 4.5-, 5.0-, and 6.0-mm pupils. Modulation transfer function and Strehl ratio were also better in eyes implanted with the Akreos AO IOL than the Akreos Fit. [J Refract Surg. 2011;27(4):287-292.] doi:10.3928/1081597X-20100714-01
Resumo:
Background: Posterior reconstruction (PR) of the rhabdosphincter has been previously described during retropubic radical prostatectomy, and shorter times to return of urinary continence were reported using this technical modification. This technique has also been applied during robot-assisted radical prostatectomy (RARP); however, contradictory results have been reported. Objective: We describe here a modified technique for PR of the rhabdosphincter during RARP and report its impact on early recovery of urinary continence and on cystographic leakage rates. Design, setting, and participants: We analyzed 803 consecutive patients who underwent RARP by a single surgeon over a 12-mo period: 330 without performing PR and 473 with PR. Surgical procedure: The reconstruction was performed using two 6-in 3-0 Poliglecaprone sutures tied together. The free edge of the remaining Denonvillier`s fascia was identified after prostatectomy and approximated to the posterior aspect of the rhabdosphincter and the posterior median raphe using one arm of the continuous suture. The second layer of the reconstruction was then performed with the other arm of the suture, approximating the posterior lip of the bladder neck and vesicoprostatic muscle to the posterior urethral edge. Measurements: Continence rates were assessed with a self-administrated, validated questionnaire (Expanded Prostate Cancer Index Composite) at 1, 4, 12, and 24 wk after catheter removal. Continence was defined as the use of ""no absorbent pads."" Cystogram was performed in all patients on postoperative day 4 or 5 before catheter removal. Results and limitations: There was no significant difference between the groups with respect to patient age, body mass index, prostate-specific antigen levels, prostate weight, American Urological Association symptom score, estimated blood loss, operative time, number of nerve-sparing procedures, and days with catheter. In the PR group, the continence rates at 1, 4, 12, and 24 wk postoperatively were 22.7%, 42.7%, 91.8%, and 96.3%, respectively; in the non-PR group, the continence rates were 28.7%, 51.6%, 91.1%, and 97%, respectively. The modified PR technique resulted in significantly higher continence rates at 1 and 4 wk after catheter removal (p = 0.048 and 0.016, respectively), although the continence rates at 12 and 24 wk were not significantly affected (p = 0.908 and p = 0.741, respectively). The median interval to recovery of continence was also statistically significantly shorter in the PR group (median: 4 wk; 95% confidence interval [CI]: 3.39-4.61) when compared to the non-PR group (median: 6 wk; 95% CI: 5.18-6.82; log-rank test, p = 0.037). Finally, the incidence of cystographic leaks was lower in the PR group (0.4% vs 2.1%; p = 0.036). Although the patients` baseline characteristics were similar between the groups, the patients were not preoperatively randomized and unknown confounding factors may have influenced the results. Conclusions: Our modified PR combines the benefits of early recovery of continence reported with the original PR technique with a reinforced watertight closure of the posterior anastomotic wall. Shorter interval to recovery of continence and lower incidence of cystographic leaks were demonstrated with our PR technique when compared to RARP with no reconstruction. (C) 2010 European Association of Urology. Published by Elsevier B.V. All rights reserved.
Resumo:
Background and study aims In many patients, percutaneous endoscopic gastrostomy (PEG) can be limited by digestive tract stenosis. PEG placement using an introducer is the safest alternative for this group of patients, but the available devices are difficult to implement and require smaller-caliber tubes. The aim of this study was to evaluate the modification of an introducer technique device for PEG placement with regard to the following: procedure feasibility, possibility of using a 20-Fr balloon gastrostomy tube, tube-related function and problems, complications, procedure safety, and mortality. Patients and methods Between March 2007 and February 2008, 30 consecutive patients with head and neck malignancies underwent introducer PEG placement with the modified device and gastropexy. Each patient was evaluated for 60 days after the procedure for the success of the procedure, infection, pain, complications, mortality, and problems with the procedure. Results The procedure was successful in all cases with no perioperative complications. No signs of stomal infection were observed using the combined infection score. The majority of patients experienced mild-to-moderate pain both in the immediate postoperative period and at 72 hours. One major early complication (3.3%) and two minor complications (6.7%) were observed. No procedure-related deaths occurred during the first 60 days after the procedure. Conclusion The device modification for PEG using the introducer technique is feasible, safe, and efficient in outpatients with obstructive head and neck cancer. In this series, it allowed the use of a larger-caliber tube with low complication rates and no procedure-related mortality.
Resumo:
Involvement of the celiac trunk and common hepatic artery are two of the most common forms of vascular invasion by tumours of the distal pancreas, and until recently this finding was considered a contra-indication to resection. We described a modified Appleby operation for locally advanced distal pancreatic cancer with compromised hepatic collateral flow that needed hepatic arterial revascularization, successfully accomplished by left external iliac-hepatic arterial bypass with Dacron prosthesis. Patient recovery was uneventful and he was discharged on the 10th postoperative day. Postoperative angio-CT disclosed a patent arterial bypass. Patient is well and asymptomatic 13 months after operation. At the time of this writing, postoperative CT scan showed no evidence of disease and CA 19-9 level is normal. There is a well established rationale to perform extended resection of pancreatic carcinomas that compromise vascular structures. Modified Appleby procedure can safely be performed, has oncological advantages to palliative procedures and provides relief of pain but is reserved for selected patients. Preservation of hepatic arterial flow has utmost importance to avoid hepatobiliary complications as liver necrosis, liver abscess, gallbladder necrosis or cholecystitis. In this case, hepatic revascularization was particularly challenging, but was successfully accomplished by left external iliac-hepatic arterial bypass. To our knowledge this type of arterial bypass has never been described so far in the English literature and its description may be important for surgeons dealing with advanced pancreatic cancer. (C) 2009 Elsevier Ltd. All rights reserved.