968 resultados para CT scan
Resumo:
Background: Cetuximab significantly enhances efficacy of radiotherapy and chemotherapy in head and neck cancer. We investigated the safety and feasibility of adding cetuximab to neoadjuvant chemoradiation of locally advanced esophageal cancer. Methods: Pts with resectable, locally advanced squamous cell carcinoma (SCC) or adenocarcinoma (AC) of the thoracic esophagus or gastroesophageal junction (staged by EUS, CT and PET scan) were treated with 2 cycles of induction chemotherapy (docetaxel 75mg/m2, cisplatin 75mg/m2 q3w and weekly cetuximab 250mg/m2), followed by concomitant chemo- immuno-radiation therapy (CIRT: docetaxel 20mg/m2, cisplatin 25mg/m2 and cetuximab 250mg/m2 weekly five times concomitant with 45 Gy radiotherapy in 25 fractions); followed by surgery 4-8 weeks later. The phase I part consisted of 2 cohorts of 7 patients each, without and with docetaxel during CIRT, respectively. Interpatient dose-escalation (adding docetaxel during CIRT) was possible if < 2 out of 7 pts of the 1st cohort experienced limiting toxicity. Having finished the phase 1 part, 13 additional patients were treated with docetaxel-containing CIRT in a phase II part. Pathological response was evaluated according to the Mandard classification. Results: 27 pts from 12 institutions were included. As of today, results from 20 pts are available (cohort 1: 7, cohort 2: 7, phase ll : 6). Median age was 64yrs (range 47-71). 11 AC; 9 SCC. 19 pts (95%) completed CIRT (1 pt stopped treatment during induction therapy due to sepsis). 17 pts underwent resection (no surgery: 1pt for PD, 1pt for cardiac reasons). Grade 3 toxicities during CIRT included anorexia 15%, dysphagia/esophagitis 15%, fatigue 10%, nausea 10%, pruritus 5%, dehydration 5%, nail changes 5% and rash 5% .1 pt suffered from pulmonary embolism. 13 pts (65%, intention-to-treat) showed a complete or near complete pathological remission (cohort 1: 5, cohort 2: 4, phase II: 4). Conclusions: Adding cetuximab to preoperative chemoradiation for esophageal cancer is safe and feasible in a community-based multicenter setting. Antineoplastic activity is encouraging with 65% pathological responders.
Resumo:
OBJECTIVE: The objective of our study was to establish a standardized procedure for postmortem whole-body CT-based angiography with lipophilic and hydrophilic contrast media solutions and to compare the results of these two methods. MATERIALS AND METHODS: Minimally invasive postmortem CT angiography was performed on 10 human cadavers via access to the femoral blood vessels. Separate perfusion of the arterial and venous systems was established with a modified heart-lung machine using a mixture of an oily contrast medium and paraffin (five cases) and a mixture of a water-soluble contrast medium with polyethylene glycol (PEG) 200 in the other five cases. Imaging was executed with an MDCT scanner. RESULTS: The minimally invasive femoral approach to the vascular system provided a good depiction of lesions of the complete vascular system down to the level of the small supplying vessels. Because of the enhancement of well-vascularized tissues, angiography with the PEG-mixed contrast medium allowed the detection of tissue lesions and the depiction of vascular abnormalities such as pulmonary embolisms or ruptures of the vessel wall. CONCLUSION: The angiographic method with a water-soluble contrast medium and PEG as a contrast-agent dissolver showed a clearly superior quality due to the lack of extravasation through the gastrointestinal vascular bed and the enhancement of soft tissues (cerebral cortex, myocardium, and parenchymal abdominal organs). The diagnostic possibilities of these findings in cases of antemortem ischemia of these tissues are not yet fully understood.
Resumo:
PURPOSE: To compare the diagnostic performance of multi-detector CT arthrography (CTA) and 1.5-T MR arthrography (MRA) in detecting hyaline cartilage lesions of the shoulder, with arthroscopic correlation. PATIENTS AND METHODS: CTA and MRA prospectively obtained in 56 consecutive patients following the same arthrographic procedure were independently evaluated for glenohumeral cartilage lesions (modified Outerbridge grade ≥2 and grade 4) by two musculoskeletal radiologists. The cartilage surface was divided in 18 anatomical areas. Arthroscopy was taken as the reference standard. Diagnostic performance of CTA and MRA was compared using ROC analysis. Interobserver and intraobserver agreement was determined by κ statistics. RESULTS: Sensitivity and specificity of CTA varied from 46.4 to 82.4 % and from 89.0 to 95.9 % respectively; sensitivity and specificity of MRA varied from 31.9 to 66.2 % and from 91.1 to 97.5 % respectively. Diagnostic performance of CTA was statistically significantly better than MRA for both readers (all p ≤ 0.04). Interobserver agreement for the evaluation of cartilage lesions was substantial with CTA (κ = 0.63) and moderate with MRA (κ = 0.54). Intraobserver agreement was almost perfect with both CTA (κ = 0.94-0.95) and MRA (κ = 0.83-0.87). CONCLUSION: The diagnostic performance of CTA and MRA for the detection of glenohumeral cartilage lesions is moderate, although statistically significantly better with CTA. KEY POINTS: ? CTA has moderate diagnostic performance for detecting glenohumeral cartilage substance loss. ? MRA has moderate diagnostic performance for detecting glenohumeral cartilage substance loss. ? CTA is more accurate than MRA for detecting cartilage substance loss.
Resumo:
Purpose: Fluoroscopy-guided sacroiliac joint (SIJ) injections are technically difficult to perform because of the complex anatomy with helicoidal conformation of the joint. Our study describes the procedure of CT-guided SIJ injection, its feasibility and its rate of success. Methods and materials: Retrospective study included 46 consecutive patients. The procedure was performed by 3 MSK radiologists and consisted in a puncture with a posterior approach in the inferior articular part of SIJ, then in an injection of iodinated contrast agent (1ml) with CT control of SIJ space opacification and finally in an injection of slowacting corticosteroid. The SIJ approach was noticed as correct if there was an inferior articular puncture and if the needle was in the articular space, and as impossible if there was ankylosis or osteophytosis. The study was divided in two successive periods: period 1 (4 first months) and period 2 (12 last months). Results: SIJ opacification was successful in 57% (26/46). We observed a learning curve: opacification was succeeded in 66% (23/35) and there was incorrect approach in 9% (3/35) during period 2 versus respectively 27% (3/11) and 45% (5/11) during period 1. Causes of failure were incorrect approach in 40% (6/20 too low, 2/20 too high), impossible approach in 30% (6/20) and unexplained in 30% (6/20). Mean duration of procedure was about 28 minutes. No complication occurred. Conclusion: CT guided SIJ injection is safe and successful in 66% after a training period. The success depends on SIJ correct approach and also on anatomical lesions.
Resumo:
High-resolution side scan sonar has been used for mapping the seafloor of the Ría de Pontevedra. Four backscatter patterns have been mapped within the Ría: (1) Pattern with isolated reflections, correlated with granite and metamorphic outcrops and located close to the coastal prominence and Ons and Onza Islands. (2) Pattern of strong reflectivity usually located around the basement outcrops and near the coastline and produced by coarse-grained sediment. (3) Pattern of weak backscatter is correlated with fine sand to mud and comprising large areas in the central and deep part of the Ría, where the bottom currents are weak. It is generally featureless, except where pockmarks and anthropogenic features are present. (4) Patches of strong and weak backscatter are located in the boundary between coarse and fine-grained sediments and they are due to the effect of strong bottom currents. The presence of megaripples associated to both patterns of strong reflectivity and sedimentary patches indicate bedload transport of sediment during high energy conditions (storms). Side scan sonar records and supplementary bathymetry, bottom samples and hydrodynamic data reveal that the distribution of seafloor sediment is strongly related to oceanographic processes and the particular morphology and topography of the Ría.
Resumo:
With the current limited availability of organs for transplantation, it is important to consider marginal donor candidates, including survivors of potentially curable malignancies such as lymphoma. The absence of refractory/recurrent residual disease at the time of brain death can be difficult to establish. Therefore, it is critical to have objective data to decide whether to proceed or not with organ procurement and transplantation. We report a unique situation in which (18)F-fluorodeoxyglucose positron emission tomography (PET) was used to rule out Hodgkin's lymphoma recurrence in a 33-year-old, heart-beating, brain-dead, potential donor with a past history of Hodgkin's disease and a persistent mediastinal mass. PET showed no significant uptake in the mass, allowing organ donation and transplantation to occur. We present a new means of evaluating potential brain-dead donors with a past history of some lymphoma, whereby PET may help transplant physicians by optimizing donation safety while rationalizing the inclusion of marginal donors.
Resumo:
PURPOSE: To determine the lower limit of dose reduction with hybrid and fully iterative reconstruction algorithms in detection of endoleaks and in-stent thrombus of thoracic aorta with computed tomographic (CT) angiography by applying protocols with different tube energies and automated tube current modulation. MATERIALS AND METHODS: The calcification insert of an anthropomorphic cardiac phantom was replaced with an aortic aneurysm model containing a stent, simulated endoleaks, and an intraluminal thrombus. CT was performed at tube energies of 120, 100, and 80 kVp with incrementally increasing noise indexes (NIs) of 16, 25, 34, 43, 52, 61, and 70 and a 2.5-mm section thickness. NI directly controls radiation exposure; a higher NI allows for greater image noise and decreases radiation. Images were reconstructed with filtered back projection (FBP) and hybrid and fully iterative algorithms. Five radiologists independently analyzed lesion conspicuity to assess sensitivity and specificity. Mean attenuation (in Hounsfield units) and standard deviation were measured in the aorta to calculate signal-to-noise ratio (SNR). Attenuation and SNR of different protocols and algorithms were analyzed with analysis of variance or Welch test depending on data distribution. RESULTS: Both sensitivity and specificity were 100% for simulated lesions on images with 2.5-mm section thickness and an NI of 25 (3.45 mGy), 34 (1.83 mGy), or 43 (1.16 mGy) at 120 kVp; an NI of 34 (1.98 mGy), 43 (1.23 mGy), or 61 (0.61 mGy) at 100 kVp; and an NI of 43 (1.46 mGy) or 70 (0.54 mGy) at 80 kVp. SNR values showed similar results. With the fully iterative algorithm, mean attenuation of the aorta decreased significantly in reduced-dose protocols in comparison with control protocols at 100 kVp (311 HU at 16 NI vs 290 HU at 70 NI, P ≤ .0011) and 80 kVp (400 HU at 16 NI vs 369 HU at 70 NI, P ≤ .0007). CONCLUSION: Endoleaks and in-stent thrombus of thoracic aorta were detectable to 1.46 mGy (80 kVp) with FBP, 1.23 mGy (100 kVp) with the hybrid algorithm, and 0.54 mGy (80 kVp) with the fully iterative algorithm.