862 resultados para COLLISIONAL PLASMA


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Topiramate and the other frequently co-administered antiepileptic drugs carbamazepine, phenytoin and phenobarbital were determined in 100 µL plasma samples by gas chromatography with nitrogen phosphorus detection (GC-NPD), after a one-step liquid-liquid extraction with ethyl acetate, followed by flash methylation with trimethylphenylammonium hydroxide. Total chromatographic run time was 12.5 min. Intra-assay and inter-assay precision was 2.5-7.3% and 1.6-5.2%, respectively. Accuracy was 100.1-104.2%. The limit of quantitation was 1 µg mL-1 for all analytes, proving suitable for routine application in therapeutic drug monitoring of antiepileptic drugs.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this study, the validation of a method for analyzing the uranium (U) concentration in human urine samples by inductively coupled plasma-sector field mass spectrometry (ICP-SFMS) was conducted. PROCORAD (the Association for the Promotion of Quality Control in Radiotoxicological Analysis) provided two urine samples spiked with unknown contents of U (Sample A = 33.6 ± 1.0 µg/L and Sample B = 3.3 ± 0.1 µg/L) and one unspiked sample as a blank. The analyses were directly performed on the diluted urine samples (dilution factor = 1:20) in 5% v/v HNO3. The results obtained by ICP-SFMS corresponded well with the reference values, and the limits of detection were 235U = 0.049 × 10-3 µg/L and 238U = 7.37 × 10-3 µg/L. The ICP-SFMS technique has been shown to be successful in the analysis of the U concentration in human urine samples and for the quantification of isotopic ratios.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A new analytical approach was developed involving cloud point extraction (CPE) and spectrofluorimetric determination of triamterene (TM) in biological fluids. A urine or plasma sample was prepared and adjusted to pH 7, then TM was quickly extracted using CPE, using 0.05% (w/v) of Triton X-114 as the extractant. The main factors that affected the extraction efficiency (the pH of the sample, the Triton X-114 concentration, the addition of salt, the extraction time and temperature, and the centrifugation time and speed) were studied and optimized. The method gave calibration curves for TM with good linearities and correlation coefficients (r) higher than 0.99. The method showed good precision and accuracy, with intra- and inter-assay precisions of less than 8.50% at all concentrations. Standard addition recovery tests were carried out, and the recoveries ranged from 94.7% to 114%. The limits of detection and quantification were 3.90 and 11.7 µg L-1, respectively, for urine and 5.80 and 18.0 µg L-1, respectively, for plasma. The newly developed, environmentally friendly method was successfully used to extract and determine TM in human urine samples.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The impacts derived from the emission of volatile organic compounds (VOC) into the atmosphere can have harmful consequences for human health and the environment. In this regard, the present paper proposes the construction of a low-cost cold plasma reactor for the treatment of these compounds. Tests with the prototype were performed to confirm the efficiency for BTEX (benzene, toluene and xylene) samples. Degradation efficiency was confirmed by the gas chromatography method.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A simple procedure for ultrasound-assisted extraction and colorimetric determination of iron in soil samples was developed. The iron concentration in the analyzed samples was determined by the colorimetric method and the results compared with inductively coupled plasma mass spectrometry (ICP-MS). Fifteen soil samples were analyzed and the iron concentration results compared with those obtained by ICP-MS using microwave-assisted sample digestion. The proposed procedure showed good efficiency for iron extraction and the results obtained by colorimetric determination exhibited good agreement with ICP-MS. Moreover, ultrasound-assisted extraction and colorimetric determination is a simple, fast and low-cost procedure for application in routine analysis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Bioorganic and biological chemistry have been found to be highly motivating to undergraduate students and in this context, biochemical blood parameter analysis emerges as highly attractive content. In this proposal, several aspects related to analyses of glucose, cholesterol and triglycerides using the enzymatic colorimetric method were involved, and the findings have at least two relevant implications: i) introducing students to connections between organic chemistry and biology based on enzymatic processes, including reactivity and mechanistic aspects; ii) performing a micro scale bioassay analysis. The proposal requires two theoretical classes (2 h per class) and one practical class (4 h).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Um sistema de injeção em fluxo envolvendo complexação com dietilditiofosfato de amônio e sorção de complexos metálicos em minicolunas de sílica gel modificada por grupos octadecil C18 é proposto para determinações multielementares em espectrometria de massa com plasma indutivamente acoplado. Influência da concentração de reagentes, natureza do ácido, tempo de reação, tempos de comutação, vazões e interferência de sódio foram investigadas. Água ou solução 2% v/v HNO3 podem ser utilizadas para lavar a coluna antes da eluição dos analitos com etanol. Amostras contendo 5000 mg Na L-1 e analisadas diretamente com o sistema proposto produzem uma concentração aparente de 63Cu de 0,45 µg L-1; por outro lado não foi observada interferência para As, Pb, Bi, Se, In, Tl, Cd, Hg e 65Cu. Para 0,25 % w/v NH4DTP e 3 mL de solução de amostra, curvas analíticas para Bi, Cu, Pb, As, Se, In, Tl, Cd, Hg no intervalo de 0,10 a 2,00 µg L-1 podem ser construídas com boas correlações (r2 > 0.998). A velocidade analítica e sensibilidade podem ser melhoradas pois dependem das condições de pré-concentração e eluição selecionadas. Com os parâmetros acima fixados, limites de detecção de 0.014 (Cu), 0.027 (As), 0.06 (Se), 0.02 (Cd), 0.029 (In), 0.043 (Hg), 0.02 (Tl), 0.06 (Pb) e 0.002 µg L-1 (Bi) foram obtidos.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The properties of the paper surface play a crucial role in ensuring suitable quality and runnability in various converting and finishing operations, such as printing. Plasma surface modification makes it possible to modify the surface chemistry of paper without altering the bulk material properties. This also makes it possible to investigate the role of the surface chemistry alone on printability without influencing the porous structure of the pigment-coated paper. Since the porous structure of a pigment coating controls both ink setting and optical properties, surface chemical changes created by a plasma modification have a potential to decouple these two effects and to permit a better optimization of them both. The aim of this work was to understand the effects of plasma surface modification on paper properties, and how it influences printability in the sheet-fed offset process. The objective was to broaden the fundamental understanding of the role of surface chemistry on offset printing. The effects of changing the hydrophilicity/ hydrophobicity and the surface chemical composition by plasma activation and plasma coatings on the properties of coated paper and on ink-paper interactions as well as on sheet-fed offset print quality were investigated. In addition, the durability of the plasma surface modification was studied. Nowadays, a typical sheet-fed offset press also contains units for surface finishing, for example UVvarnishing. The role of the surface chemistry on the UV-varnish absorption into highly permeable and porous pigment-coated paper was also investigated. With plasma activation it was possible to increase the surface energy and hydrophilicity of paper. Both polar and dispersion interactions were found to increase, although the change was greater in the polar interactions due to induced oxygen molecular groups. The results indicated that plasma activation takes place particularly in high molecular weight components such as the dispersion chemicals used to stabilize the pigment and latex particles. Surface composition, such as pigment and binder type, was found to influence the response to the plasma activation. The general trend was that pilot-scale treatment modified the surface chemistry without altering the physical coating structure, whereas excessive laboratory-scale treatment increased the surface roughness and reduced the surface strength, which led to micro-picking in printing. It was shown that pilot-scale plasma activation in combination with appropriate ink oils makes it possible to adjust the ink-setting rate. The ink-setting rate decreased with linseed-oil-based inks, probably due to increased acid-base interactions between the polar groups in the oil and the plasma-treated paper surface. With mineral-oil-based inks, the ink setting accelerated due to plasma activation. Hydrophobic plasma coatings were able to reduce or even prevent the absorption of dampening water into pigmentcoated paper, even when the dampening water was applied under the influence of nip pressure. A uniform hydrophobic plasma coating with sufficient chemical affinity with ink gave an improved print quality in terms of higher print density and lower print mottle. It was also shown that a fluorocarbon plasma coating reduced the free wetting of the UV-varnish into the highly permeable and porous pigment coating. However, when the UV-varnish was applied under the influence of nip pressure, which leads to forced wetting, the role of the surface chemical composition seems to be much less. A decay in surface energy and wettability occurred during the first weeks of storage after plasma activation, after which it leveled off. However, the oxygen/carbon elemental ratio did not decrease as a function of time, indicating that ageing could be caused by a re-orientation of polar groups or by a contamination of the surface. The plasma coatings appeared to be more stable when the hydrophobicity was higher, probably due to fewer interactions with oxygen and water vapor in the air.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJETIVO: Estabelecer um método barato e eficiente de preparação do plasma rico em plaquetas e fatores de crescimento para utilização em cirurgia plástica. MÉTODO: Foram realizados 20 testes através de centrifugação de sangue, variando-se a força e o tempo de centrifugação, para determinarmos o melhor método que proporcione uma maior concentração plaquetária e mais 10 testes para comprovar a reprodutibilidade do método. RESULTADOS: A utilização de uma força de centrifugação de 300 g por 10 minutos na 1ª. centrifugação e de 640 g por 10 minutos na 2ª. centrifugação obtiveram as maiores concentrações plaquetárias, superiores a 4,5 vezes a concentração na amostra, e os testes foram reprodutíveis. CONCLUSÕES: Uma alta concentração plaquetária pode ser obtida por este protocolo de obtenção de plasma rico em plaquetas e fatores de crescimento e a formação do gel é possível através da utilização de trombina autóloga, também obtida pelo protocolo descrito, facilitando sua utilização em cirurgia plástica, onde vem mostrando bons resultados na cicatrização de feridas e na integração de enxertos ósseos e cutâneos.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJETIVO: Definir qual a melhor potência a ser empregada de forma a atingir a profundidade necessária para ablação com o menor número de sintomas pós-procedimento. MÉTODO: Foram estudados 28 pacientes com esôfago de Barrett, após tratamento cirúrgico do refluxo ou em uso de bloqueadores de bomba de prótons, submetidos à ablação endoscópica, randomizados em dois grupos com potências diferentes - 50 ou 70W. Imediatamente após, foram realizadas biópsias endoscópicas das áreas fulguradas. A sintomatologia foi avaliada por questionário telefônico. RESULTADOS: Não houve diferença entre os grupos quanto a idade, a extensão do esôfago de Barrett, a porcentagem da circunferência esofagiana coagulada e a duração dos sintomas. A dor foi o sintoma predominante e a disfagia ocorreu de forma transitória. Houve correlação negativa moderada entre número de sintomas e potência (potência mais baixa com maior número de sintomas), porém sem diferença significativa. Em 40% dos casos em que se utilizou menor potência obteve-se fragmentos que atingiram apenas a porção superficial da mucosa, o que só ocorreu em 10% dos casos no grupo de 70W. Não foi observada diferença significativa entre a potência utilizada ou o acometimento da muscular da mucosa e o número de sintomas. CONCLUSÕES: A utilização de potência de 70W durante a coagulação do esôfago de Barrett com plasma de argônio sugere associação com menor incidência de metaplasia colunar especializada residual abaixo do epitélio escamoso neoformado.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

O plasma autólogo começou a ser estudado na década de 90, principalmente por suas propriedades adesivas, de angiogênese e pela presença de fatores de crescimento de origem plaquetária. Na verdade, o plasma pode ser isolado de modo autólogo, a partir do sangue do próprio paciente e obtido nas suas duas porções: uma com alta concentração de plaquetas (plasma rico em plaquetas- PRP) e outra com concentração baixa de plaquetas (plasma pobre em plaquetas- PPP). O presente estudo está em desenvolvimento no Hospital Universitário Clementino Fraga Filho, da Universidade Federal do Rio de Janeiro (HUCFF-UFRJ) e no Hospital Naval Marcílio Dias (HNMD), ambos no Rio de Janeiro. O objetivo é avaliar as propriedades do plasma pobre em plaquetas, principalmente a sua ação adesiva, em pacientes com indicação de dermolipectomia abdominal reparadora, de modo a reduzir as coleções no pós operatório, como hematoma e seroma, duas das principais complicações nesse tipo de cirurgia.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJETIVO: avaliar a eficácia da complementação por coagulação com plasma de argônio para reduzir a taxa de neoplasia residual ou recorrente após ressecção endoscópica completa fragmentada de grandes adenomas sésseis colorretais. MÉTODOS: critérios de inclusão: pacientes com grandes adenomas colorretais sésseis, > 20mm, sem sinais morfológicos de infiltração profunda, submetidos à ressecção endoscópica completa fragmentada estudada com cromoendoscopia e magnificação de imagens. Os pacientes foram randomizados em dois grupos: grupo 1 - nenhum procedimento adicional e, grupo 2 - complementação por coagulação com plasma de argônio. O seguimento por colonoscopia foi realizado em três, seis e 12 meses de pós-operatório. Foi avaliada a taxa de neoplasia residual ou recidiva local. RESULTADOS: foram incluídos no estudo um total de 21 lesões. Onze lesões no grupo 1 e dez no grupo 2. Ocorreram duas neoplasias residuais ou recorrências locais em cada grupo, detectadas em três meses de acompanhamento. CONCLUSÃO: a complementação por coagulação com plasma de argônio após uma aparente ressecção endoscópica completa em fragmentos de grandes adenomas sésseis colorretais não parece reduzir a ocorrência de lesão adenomatosa residual ou recidiva local.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJETIVO: avaliar um novo método de determinação do sexo fetal pela análise de DNA obtido do plasma materno. MÉTODOS: sangue periférico (10 mL) foi coletado de mulheres grávidas em diferentes idades gestacionais. O plasma foi separado e o DNA isolado do mesmo foi submetido à reação em cadeia da polimerase (PCR) com oligonucleotídeos iniciadores derivados do gene DYS14 específico do cromossomo Y. RESULTADOS: foram analisadas amostras de 212 pacientes. O resultado da PCR foi comparado ao sexo determinado pela ultra-sonografia e/ou do nascimento. Houve concordância em 209 das 212 pacientes. Nos 3 casos discordantes a PCR apontou resultado feminino, sendo as três amostras coletadas antes da 8ª semana de gravidez. CONCLUSÃO: o método de PCR desenvolvido para a determinação do sexo fetal possui excelente sensibilidade e especificidade, permitindo seu uso rotineiro. O resultado de sexo masculino possui maior confiabilidade que o feminino, principalmente em idade gestacional precoce. Novas aplicações para o DNA fetal no plasma materno estão sendo pesquisadas, permitindo no futuro o diagnóstico não invasivo de uma série de doenças.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJETIVO: avaliar a possibilidade do diagnóstico precoce do sexo fetal no plasma materno pela técnica da reação em cadeia da polimerase em tempo real (PCR em tempo real) a partir da 5ª semana de gestação. MÉTODOS: nesse estudo prospectivo foi coletado sangue periférico de gestantes com feto único a partir da 5ª semana de gestação. Após centrifugação do sangue, 0,4 mL de plasma foi separado para extração de DNA fetal. O DNA foi analisado em duplicata por PCR em tempo real para duas regiões genômicas (uma do cromossomo Y e outra comum a ambos os sexos) pelo método de TaqMan®, o qual utiliza um par de primers e uma sonda fluorescente. Foram excluídos da amostragem os casos que evoluíram para aborto. Para o cálculo da sensibilidade e especificidade, usamos o método de comparação com padrão-ouro, que foi o sexo ao nascimento. RESULTADOS: foram realizados 79 exames de DNA fetal no plasma materno de 52 gestantes. O resultado dos exames foi comparado com o sexo da criança após o parto. O índice de acerto conforme a idade gestacional foi de 92,6% (25 de 27 casos) na 5ª semana, conferindo sensibilidade de 87% e 95,6% (22 de 23 casos) na 6ª semana, com sensibilidade de 92%. A partir da 7ª semana de gestação o acerto foi em 100% (29 de 29 casos). A especificidade foi de 100% independente da idade gestacional. CONCLUSÕES: a técnica de PCR em tempo real para detecção do sexo fetal a partir da 5ª semana no plasma materno possui boa sensibilidade e excelente especificidade. Houve concordância do resultado em 100% dos casos em que o diagnóstico foi masculino, independente da idade gestacional, e no caso de feminino, a partir da 7ª semana de gestação.