946 resultados para COLLAGEN INJECTION


Relevância:

20.00% 20.00%

Publicador:

Resumo:

A rapid and simple method for procaine determination was developed by flow injection analysis (FIA) using a screen-printed carbon electrode (SPCE) as amperometric detector. The present method is based on the amine/hydroxylamine oxidation from procaine monitored at 0.80 V on SPCE in sodium acetate solution pH 6.0. Using the best experimental conditions assigned as: pH 6.0, flow rate of 3.8 mL min(-1), sample volume of 100 mu L and analytical path of 30 cm it is possible to construct a linear calibration curve from 9.0 x 10(-6) to 1.0 x 10(-4) mol L-1. The relative standard deviation for 5.0 x 10(-5) mol L-1 procaine (15 repetitions using the same electrode) is 3.2% and detection limit calculated is 6.0 x 10(-6) mol L-1. Recoveries obtained for procaine gave a mean values from 94.8 to 102.3% and an analytical frequency of 36 injections per hour was achieved. The method was successfully applied for the determination of procaine in pharmaceutical formulation without any pre-treatment, which are in good accordance with the declared values of manufacturer and an official method based on spectrophotometric analysis. (c) 2006 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A method based an ion exchange(IE)-atomic absorption spectrometry(AAS) coupled by flow techniques, allowing the determination of formation constants of, at least, the first species of complex systems, in aqueous solution, was developed.The IE-AAS coupling reduces significantly the number of experimental steps in comparison with IE batch methods, resulting in an important increase in analytical rate. The method is simple both from experimental and computational points of view, making possible its utilization by workers without special expertise in the field of complex equilibria in solution. on the other hand, taking into account mainly the amount of hollow cathode lamps available to date, the developed procedure may be applied, within certain limitations, to the study of many systems whose features prevent the use of traditional approaches.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An automatic Procedure with a high current-density anodic electrodissolution unit (HDAE) is proposed for the determination of aluminium, copper and zinc in non-ferroalloys by flame atonic absorption spectrometry, based on the direct solid analysis. It consists of solenoid valve-based commutation in a flow-injection system for on-line sample electro-dissolution and calibration with one multi-element standard, an electrolytic cell equipped with two electrodes (a silver needle acts as cathode, and sample as anode), and an intelligent unit. The latter is assembled in a PC-compatible microcomputer for instrument control, and far data acquisition and processing. General management of the process is achieved by use of software written in Pascal. Electrolyte compositions, flow rates, commutation times, applied current and electrolysis time mere investigated. A 0.5 mol l(-1) HNO3 solution was elected as electrolyte and 300 A/cm(2) as the continuous current pulse. The performance of the proposed system was evaluated by analysing aluminium in Al-allay samples, and copper/zinc in brass and bronze samples, respectively. The system handles about 50 samples per hour. Results are precise (R.S.D < 2%) and in agreement with those obtained by ICP-AES and spectrophotometry at a 95% confidence level.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A method was developed using the multi-element graphite furnace atomic absorption spectrometry technique for the direct and simultaneous determination of As, Cu, and Pb in Brazilian sugar cane spirit (cachaqa) samples. Also employed was the end-capped transversely heated graphite atomizer (THGA) with platforms pre-treated with W permanent modifier and co-injection of Pd/Mg(NO3)(2). Pyrolysis and atomization temperature curves were established in a cachaqa medium (1+1; v/v) containing 0.2% (v/v) HNO3 and spiked with 20 mu g L-1 As and Pb and 200 mu g L-1 Cu. The effect of the concentration of major elements usually present in cachaqa matrices (Ca, Mg, Na, and K) and ethanol on the absorbance of As, Cu, and Pb was investigated. Analytical working solutions of As, Cu, and Pb were prepared in 10% (v/v) ethanol plus 5.0 mg L-1 Ca, Mg, Na, and K. Acidified to 0.2% (v/v) HNO3, these solutions were suitable to build calibration curves by matrix matching. The proposed method was applied to the simultaneous determination of As, Cu, and Pb in commercial sugar cane spirits. The characteristic mass for the simultaneous determination was 16 pg As, 119 pg Cu, and 28 pg Pb. The pretreated tube lifetime was about 450 firings. The limit of detection (LOD) was 0.6 mu g L-1 As, 9.2 mu g L-1 Cu, and 0.3 pig L-1 Pb. The found concentrations varied from 0.81 to 4.28 mu g L-1 As, 0.28 to 3.82 mg L-1 Cu and 0.82 to 518 mu g L-1 Pb. The recoveries of the spiked samples varied from 94-112% (As), 97-111% (Cu), and 95-101% (Pb). The relative standard deviation (n=12) was 6.9%, 7.4%, and 7.7% for As, Cu, and Pb, respectively, present in a sample at 0.87 mu g L-1, 0.81 mg L-1, and 38.9 mu g L-1 concentrations.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: To compare the safety and anti-inflammatory efficacy of a single posterior subtenon injection of triamcinolone acetonide (TA) with prednisolone acetate 1% eyedrops after pars plana vitrectomy (PPV).Methods: the study included 40 consecutive phakic eyes of 40 patients undergoing PPV for non-clearing vitreous haemorrhage with attached retina (verified by echography), epiretinal membrane or macular hole. At the end of the surgical procedure, eyes were randomized to receive either a single posterior subtenon injection of TA (40 mg in 1 ml) plus sham eyedrops (prednisolone acetate 1% vehicle) postoperatively (group TA), or a posterior subtenon sham injection (1 ml balanced salt solution) plus prednisolone acetate 1% eyedrops postoperatively (group ED).Results: There was no difference in the severity of anterior chamber cell and flare between the two groups at any time-point during the study period (p > 0.05). Separate within-group analysis revealed a significant decrease in anterior chamber cell and flare from postoperative day 1 to postoperative days 7, 14 and 28 in both groups (p < 0.05). There was no difference in pain, photophobia, conjunctival erythema, ciliary flush or chemosis scores between the two groups at any time-point during the study period (p > 0.05). Steroid-induced intraocular hypertension was not observed in either group.Conclusions: A single posterior subtenon injection of TA can be as effective and safe as a 4-week regimen of prednisolone acetate 1% eyedrops in controlling intraocular inflammation after PPV.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The changes of arterial pressure promoted by bolus injection of 50 mg phenylephrine (PHE) were studied in 20 atropinized patients (5 normal subjects, 13 patients with mitral valve disease, 1 patient with essential arterial hypertension and 1 patient with hypertrophic cardiomyopathy) submitted to routine catheterism. Patients with aortic valve disease, left ventricular outflow tract obstruction and intracardiac shunt were excluded from the study. All patients were in sinus rhythm, without heart failure. Arterial pressure started to increase at 14.8 +/- 5.4 s (range, 5.6 to 27 s; mean +/- SD) after PHE. There was an increase of 37.8 +/- 16.7 mmHg (range, 12.5 to 70 mmHg) in systolic pressure and of 26.6 +/- 11.1 mmHg (range, 7.5 to 42.5 mmHg) in diastolic pressure. Peak hypertension was attained at 36.6 +/- 16.4 s (range, 10.8 to 64.9 s) and hypertension continued for 176 +/- 92 s (range, 11 to 365 s). Heart rate was 114 +/- 21 bpm before PHE and 111 +/- 21 bpm (P<0.05) after PHE. There were no adverse events associated with intravenous PHE injection in any patient, in accordance with the general view that bolus injection of PHE is a safe and practical maneuver to promote arterial hypertension.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Statement of problem. A clinically significant incisal pin opening may occur after processing complete dentures if a compression molding technique is used. To recover the proper vertical dimension of occlusion, a time-consuming occlusal adjustment is necessary that often destroys the anatomy of the artificial teeth. A new injection molding process claims to produce dentures that require few, if any, occlusal adjustments in the laboratory after processing.Purpose. This laboratory study compared incisal pin opening, dimensional accuracy, and laboratory working time for dentures fabricated by this new injection system with dentures constructed by the conventional compression molding technique.Material and methods. Two groups of 6 maxillary and 6 mandibular dentures were evaluated as follows: group 1 (control), Lucitone 199, compression molded with a long cure cycle; and group 2, Lucitone 199, injection molded with a long cure. Incisal pin opening was measured with a micrometer immediately after deflasking. A computerized coordinate measuring machine was used to measure dimensional accuracy of 3-dimensional variations in selected positions of artificial teeth in 4 stages of denture fabrication. Analysis of variance (ANOVA) and t tests were performed to compare the groups.Results. A significant difference was found in pin opening between groups (t test). Horizontal dimensional changes evaluated with repeated measures ANOVA revealed no significant differences between groups. However, analysis of vertical dimensional changes disclosed significant differences between the groups. There was no appreciable difference in laboratory working time for flasking and molding denture bases between the injection and compression molding techniques when polymethyl methacrylate resin was used.Conclusion. The injection molding method produced a significantly smaller incisal pin opening over the standard compression molding technique. The injection molding technique, using polymethyl methacrylate, was a more accurate method for processing dentures. There were no appreciable differences in laboratory working time between the injection and compression molding techniques.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study aims to evaluate the effect of using anionic collagen membranes in guided tissue regeneration treatment of Class II furcation lesions in dogs. The defects were created in the buccal furcation of 16 mandibular premolars of four dogs. After 56 days without plaque control, the sites were scaled and divided into two groups according to the treatment applied: control sites, open flap debridement; and test sites, guided tissue regeneration treatment. The animals were killed after 3 months. Histological and histometrical analyses showed that the collagen membrane was better than open flap debridement in terms of newly formed cementum and epithelial migration prevention. It provided effective blockade of epithelial tissue and promoted regeneration of lost periodontal tissues, suggesting that the membrane warrants further study. (C) 1997 Elsevier B.V. Limited. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background and Objectives. A combination of epidural and general anesthesia has been widely used to attenuate the surgical stress response and to provide postoperative analgesia. This case report illustrates the use of this anesthetic technique. Analgesia was induced with local anesthetic in the immediate postoperative period using unintentional 19.1% potassium chloride (KCI) as diluent. Methods. An ASA I male patient was scheduled for surgical correction of idiopathic megaesophagus under continuous epidural anesthesia combined with general anesthesia. In the postoperative period, while preparing 10 mt 0.125% bupivacaine to be administered through the epidural catheter for pain control, 5 mt 19.1% KCI was unintentionally used as diluent, resulting in a 9.55% potassium solution concentration. Results. The patient developed warmness of the lower limbs, tachycardia, hypertension, intense pruritus on the chest, agitation, exacerbation of sensory and motor blocks, and respiratory failure secondary to pulmonary edema, requiring ventilatory support. Total recovery was observed after 24 hours. Conclusions. Epidurally injected potassium leads to severe clinical manifestations caused by autonomic dysfunction, spinal cord irritation, and possible release of histamine. Despite continuous recommendations, ampule misidentification still happens in hospitals, frequently leading to serious accidents.