902 resultados para Bouncing ball
Resumo:
The reduction of the power loss generated in mechanical transmissions and the use of low friction biodegradable lubricants has been attracting considerable attention in recent times. Therefore, it is necessary to develop methods to test and evaluate the performance of such lubricants and compare them with conventional ones. In this sense, a Four-Ball Machine was modified allowing the test of rolling bearings. A 51107 thrust ball bearing was used to test two different greases and the corresponding base oils. Friction torque and operating temperatures were continuously monitored to quantify the power loss and the heat evacuation for each lubricant tested. Copyright © 2010 John Wiley & Sons, Ltd.
Resumo:
In the injection moulding of polypropylene reinforced with hard glass fibres, die materials are commonly subjected to severe abrasive wear. In order to improve its wear resistance, an unbalanced magnetron sputtering PVD compositional monolayered coating has been produced. The film was composed by a nanostructured TiB2 monolayer. Microstructure characterization and thickness evaluation were conducted by scanning electron microscopy (SEM). Film topography and roughness were accessed by SEM and Atomic Force Microscopy (AFM). The phase analyse was investigated by X-ray diffraction (XRD), using Cu Kalpha radiation. Scratch tests were conducted in order to study the film adhesion to the substrate. Load-Displacement curves (nanoindentation analysis) allowed measuring the film hardness and Young's modulus. A ball-cratering tribometer was used to determine the micro-abrasion laboratorial wear resistance, under different tests conditions, using SiC particles in distilled water slurry. At the end of these tests, the worn surfaces were analyzed by SEM and Energy Dispersive X-ray Spectroscopy (EDS) in order to compare these results with some other coatings already tested in the same conditions. To test the practical wear resistance, 135000 injection cycles were done in a plastic injection industrial mould. Coated samples were put on the plastic feed canal, after a turbulent zone. In these tests, a 30% (wt) glass fibres reinforced polypropylene was used. Worn sample surfaces were analyzed by SEM after 45.000 and 90.000 cycles. Image analyses were made in order to evaluate the damage increases and to observe the wear mechanisms involved.
Resumo:
Micro-abrasion wear tests with ball-cratering configuration are widely used. Sources of variability are already studied by different authors and conditions for testing are parameterized by BS EN 1071-6: 2007 standard which refers silicon carbide as abrasive. However, the use of other abrasives is possible and allowed. In this work, ball-cratering wear tests were performed using four different abrasive particles of three dissimilar materials: diamond, alumina and silicon carbide. Tests were carried out under the same conditions on a steel plate provided with TiB2 hard coating. For each abrasive, five different test durations were used allowing understanding the initial wear phenomena. Composition and shape of abrasive particles were investigated by SEM and EDS. Scar areas were observed by optical and electronic microscopy in order to understand the wear effects caused by each of them. Scar geometry and grooves were analyzed and compared. Wear coefficient was calculated for each situation. It was observed that diamond particles produce well-defined and circular wear scars. Different silicon carbide particles presented dissimilar results as consequence of distinct particle shape and size distribution.
Resumo:
Num sistema de ensino cada vez mais exigente, a experimentação assume um papel fundamental na aquisição e validação do conhecimento. No ensino da Física, a necessidade de compreender a influência do meio num dado conceito teórico leva a que a experimentação tenha um carácter obrigatório. Neste contexto, surgem três cenários capazes de suportar a aprendizagem dos conceitos teóricos adquiridos. A simulação que faz uso da velocidade e capacidades de cálculo do computador para obter o resultado de uma experiência, a experimentação tradicional em laboratório, na qual o aluno executa, presencialmente, a sua experiência e por último a experimentação remota, que permite a execução de uma experiência real sem a presença física do aluno. Esta dissertação apresenta o projeto de um aparato para experimentação remota do “Lançamento de projéteis”. De forma a providenciar um meio de ensino de Física mais flexível, o aparato desenvolvido permite, aos alunos, a determinação da aceleração da gravidade e o estudo da dependência do movimento de um projétil num conjunto de parâmetros. Este aparato, operado remotamente, é acedido via web, onde primeiramente é reservado um intervalo de tempo. O conjunto de parâmetros (“Bola”, “Altura de lançamento” e “Ângulo de lançamento”) da máquina permite suportar vários cenários de ensino da Física, com diferentes complexidades.
Resumo:
Ball rotating micro-abrasion tribometers are commonly used to carry out wear tests on thin hard coatings. In these tests, different kinds of abrasives were used, as alumina (Al2O3), silicon carbide (SiC) or diamond. In each kind of abrasive, several particle sizes can be used. Some studies were developed in order to evaluate the influence of the abrasive particle shape in the micro-abrasion process. Nevertheless, the particle size was not well correlated with the material removed amount and wear mechanisms. In this work, slurry of SiC abrasive in distilled water was used, with three different particles size. Initial surface topography was accessed by atomic force microscopy (AFM). Coating hardness measurements were performed with a micro-hardness tester. In order to evaluate the wear behaviour, a TiAlSiN thin hard film was used. The micro-abrasion tests were carried out with some different durations. The abrasive effect of the SiC particles was observed by scanning electron microscopy (SEM) both in the films (hard material) as in the substrate (soft material), after coating perforation. Wear grooves and removed material rate were compared and discussed.
Resumo:
The injection process of glass fibres reinforced plastics promotes the moulds surface degradation by erosion. In order to improve its wear resistance, several kinds of PVD thin hard coatings were used. It is well-known that nanostructures present a better compromise between hardness and toughness. Indeed, when the coating is constituted by a large number of ultra-thin different layers, cracks and interface troubles tend to decrease. However, it is not clear that these nanostructures present a better wear behaviour in erosion processes. In order to study its wear behaviour, a sputtered PVD nanostructured TiAlCrSiN coating was used. The substrate and film surfaces topography were analyzed by profilometry and atomic force microscopy techniques. Film adhesion to the substrate was evaluated by scratch tests. The surface hardness was measured with a Vickers micro-hardness tester. The wear resistance was evaluated by micro-abrasion with a rotating ball tribometer tests. Slurry of SiC particles in distilled water was used in order to provoke the surface abrasion. Different duration tests were performed in order to analyze the wear evolution. After these tests, the wear mechanisms developed were analyzed by scanning electron microscopy. Wear craters were measured and the wear rate was calculated and discussed. With the same purpose, coated inserts were mounted in an injection mould working with a 30% glass fibres reinforced polypropylene. After 45 000 cycles no relevant wear was registered.
Resumo:
The minimization of the power loss and the use of the biodegradable greases have attracting considerable attention. To compare the energetic performance of biodegradable lubricant greases, power loss tests were performed on a modified four-ball machine. A correlation between the grease formulation and rheology was established with its energetic performance
Resumo:
Six cases of a cavitary pulmonary ball formed by Actinomycetes are reported. They were observed in the state of Bahia, Brazil. All patients complained of cough and hemoptysis and the pathological study showed bronchiectasis and small cavities in the lungs. The lesions contained micro-colonies of Actinomyces, identified by morphology, staining properties and culture in two cases (thioglycolate media). In the six patients the disease was limited to the lungs. In one patient grains were found, within micro-abscesses in the surrounding parenchyma. Probably the invasion occurred due to ulceration of bronchial mucosa that was covered by granulation tissue. The author suggests that as in nocardiosis actinomycosys may have an invasive form, a saprophytic one may and colonize pulmonary cavities.
Resumo:
Mestrado em Engenharia Geotécnica e Geoambiente
Resumo:
Two cases of Chronic Pulmonary Histoplasmosis are reported and other eleven cases, collected from Brazilian literature, are commented. After being clinically cured, one of our patients presented an Aspergillus fungus ball inside a cavitation in the wall of which H. capsulatum was disclosed. Comments are also done on the diagnosis of the mycosis
Resumo:
Four cases of respiratory tract intracavitary colonization (fungus ball) due to Scedosporium apiospermum (teleomorph, Pseudallescheria boydii) are reported. The need for a careful search for anneloconidia, in order to establish the etiologic diagnosis in the clinical specimen by microscopy, is emphasized.
Resumo:
A compreensão do conceito de OPA é essencial de forma a entender o funcionamento das combinações empresariais. Esta dissertação tem dois objetivos. O primeiro objetivo tem a finalidade de perceber quais as estratégias defensivas mais eficazes em contexto de OPA. Foi através de um inquérito realizado a 192 empresas envolvidas em situação de OPA entre os anos 1991 e 2014. Através dos resultados das 14 respostas destaca-se que a Recompra de Ações é a estratégia defensiva mais utilizada, tanto em situações de defesas pré-proposta e pós-proposta. A defesa consegue evitar o sucesso, da proposta efetuada pela empresa adquirente, em mais de metade das situações em que é utilizada, tendo sido classificada como muito eficaz. 5 das operações foram de cariz hostil e 7 delas eram expectáveis pela Gestão. Em nenhuma das operações se verificou contraoperação e as áreas mais prejudicadas, pela iniciativa de OPA, foram as respeitantes ao tempo, Time-consuming, e estratégicas. O segundo objetivo tenta perceber o comportamento dos retornos médios anormais das empresas envolvidas numa OPA em face do respetivo anúncio preliminar. Seguiram-se as metodologias de Ball & Brown (1968) e Beaver (1968). Identificaram-se 100 operações compreendidas entre os anos 2000 e 2014. Através do resultado das 12 operações analisadas confirma-se que as empresas-alvo apresentam um retorno médio anormal superior ao das empresas adquirentes e que têm a tendência de acumular retornos médios anormais positivos, pelo contrário as empresas adquirentes têm a tendência de acumular retornos médios anormais negativos. Globalmente, as empresas reagem fortemente ao anúncio preliminar e apresentam uma tendência de ganho nos períodos circundantes e não-circundantes.
Resumo:
A PhD Dissertation, presented as part of the requirements for the Degree of Doctor of Philosophy from the NOVA - School of Business and Economics
Resumo:
Dissertation presented the Ph.D degree in Biology
Resumo:
In this work, a volumetric unit previously assembled by the research group was upgraded. This unit revamping was necessary due to the malfunction of the solenoid valves employed in the original experimental setup, which were not sealing the gas properly leading to erroneous adsorption equilibrium measurements. Therefore, the solenoid valves were substituted by manual ball valves. After the volumetric unit improvement its operation was validated. For this purpose, the adsorption equilibrium of carbon dioxide (CO2) at 323K and 0 - 20 bar was measured on two different activated carbon samples, in the of extrudates (ANG6) and of a honeycomb monolith (ACHM). The adsorption equilibrium results were compared with data previously measured by the research group, using a high-pressure microbalance from Rubotherm GmbH (Germany) – gravimetric. The results obtained using both apparatuses are coincident thus validating the good operation of the volumetric unit upgraded in this work. Furthermore, the adsorption equilibrium of CO2 at 303K and 0 - 10 bar on Metal-Organic Frameworks (MOFs) Cu-BTC and Fe-BTC was also studied. The CO2 adsorption equilibrium results for both MOFs were compared with the literature results showing good agreement, which confirms the good quality of the experimental results obtained in the new volumetric unit. Cu-BTC sample showed significantly higher CO2 adsorption capacity when compared with the Fe-BTC sample. The revamping of the volumetric unit included a new valve configuration in order to allow testing an alternative method for the measurement of adsorption equilibrium. This new method was employed to measure the adsorption equilibrium of CO2 on ANG6 and ACHM at 303, 323 and 353K within 0-10 bar. The good quality of the obtained experimental data was testified by comparison with data previously obtained by the research group in a gravimetric apparatus.