941 resultados para Aortic Coarctation


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Current artificial heart valves are classified as mechanical and bioprosthetic. An appealing pathway that promises to overcome the shortcomings of commercially available heart valves is offered by the interdisciplinary approach of cardiovascular tissue engineering. However, the mechanical properties of the Tissue Engineering Heart Valves (TEHV) are limited and generally fail in the long-term use. To meet this performance challenge novel biodegradable triblock copolymer poly(ethylene oxide)-polypropylene oxide)-poly(ethylene oxide) (PEO-PPO-PEO or F108) crosslinked to Silk Fibroin (F108-SilkC) to be used as tri-leaflet heart valve material was investigated. ^ Synthesis of ten polymers with varying concentration and thickness (55 µm, 75 µm and 100 µm) was achieved via a covalent crosslinking scheme using bifunctional polyethylene glycol diglycidyl ether (PEGDE). Static and fatigue testing were used to assess mechanical properties of films, and hydrodynamic testing was performed to determine performance under a simulated left ventricular flow regime. The crosslinked copolymer (F108-Silk C) showed greater flexibility and resilience, but inferior ultimate tensile strength, by increasing concentration of PEGDE. Concentration molar ratio of 80:1 (F108: Silk) and thickness of 75 µm showed longer fatigue life for both tension-tension and bending fatigue tests. Four valves out of twelve designed satisfactorily complied with minimum performance requirement ISO 5840, 2005. ^ In conclusion, it was demonstrated that the applicability of a degradable polymer in conjugation with silk fibroin for tissue engineering cardiovascular use, specifically for aortic valve leaflet design, met the performance demands. Thinner thicknesses (t<75 µm) in conjunction with stiffness lower than 320 MPa (80:1, F108: Silk) are essential for the correct functionality of proposed heart valve biomaterial F108-SilkC. Fatigue tests were demonstrated to be a useful tool to characterize biomaterials that undergo cyclic loading. ^

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: The American College of Cardiology guidelines recommend 3 months of anticoagulation after replacement of the aortic valve with a bioprosthesis. However, there remains great variability in the current clinical practice and conflicting results from clinical studies. To assist clinical decision making, we pooled the existing evidence to assess whether anticoagulation in the setting of a new bioprosthesis was associated with improved outcomes or greater risk of bleeding. METHODS AND RESULTS: We searched the PubMed database from the inception of these databases until April 2015 to identify original studies (observational studies or clinical trials) that assessed anticoagulation with warfarin in comparison with either aspirin or no antiplatelet or anticoagulant therapy. We included the studies if their outcomes included thromboembolism or stroke/transient ischemic attacks and bleeding events. Quality assessment was performed in accordance with the Newland Ottawa Scale, and random effects analysis was used to pool the data from the available studies. I(2) testing was done to assess the heterogeneity of the included studies. After screening through 170 articles, a total of 13 studies (cases=6431; controls=18210) were included in the final analyses. The use of warfarin was associated with a significantly increased risk of overall bleeding (odds ratio, 1.96; 95% confidence interval, 1.25-3.08; P<0.0001) or bleeding risk at 3 months (odds ratio, 1.92; 95% confidence interval, 1.10-3.34; P<0.0001) compared with aspirin or placebo. With regard to composite primary outcome variables (risk of venous thromboembolism, stroke, or transient ischemic attack) at 3 months, no significant difference was seen with warfarin (odds ratio, 1.13; 95% confidence interval, 0.82-1.56; P=0.67). Moreover, anticoagulation was also not shown to improve outcomes at time interval >3 months (odds ratio, 1.12; 95% confidence interval, 0.80-1.58; P=0.79). CONCLUSIONS: Contrary to the current guidelines, a meta-analysis of previous studies suggests that anticoagulation in the setting of an aortic bioprosthesis significantly increases bleeding risk without a favorable effect on thromboembolic events. Larger, randomized controlled studies should be performed to further guide this clinical practice.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The development of atherosclerosis in the aorta is associated with low and oscillatory wall shear stress for normal patients. Moreover, localized differences in wall shear stress heterogeneity have been correlated with the presence of complex plaques in the descending aorta. While it is known that coarctation of the aorta can influence indices of wall shear stress, it is unclear how the degree of narrowing influences resulting patterns. We hypothesized that the degree of coarctation would have a strong influence on focal heterogeneity of wall shear stress. To test this hypothesis, we modeled the fluid dynamics in a patient-specific aorta with varied degrees of coarctation. We first validated a massively parallel computational model against experimental results for the patient geometry and then evaluated local shear stress patterns for a range of degrees of coarctation. Wall shear stress patterns at two cross sectional slices prone to develop atherosclerotic plaques were evaluated. Levels at different focal regions were compared to the conventional measure of average circumferential shear stress to enable localized quantification of coarctation-induced shear stress alteration. We find that the coarctation degree causes highly heterogeneous changes in wall shear stress.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We report the case of a 82-year-old woman, asymptomatic, subject to chest computed tomography for trauma. Then the patient underwent surgery. Before sternotomy, femoro-femoral bypass was starter in order to decompress the aneurysm; using deep hypothermia and circulatory arrest, ascending aorta and hemiarch replacement were performed with a Dacron graft. Post-operative course was uneventful.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Minimally invasive approach for aortic valve surgery has been developed since 1995, reducing the complications related to the full sternotomy. We have introduced a new method for central cannulation that reduces the length of surgical incision for the aortic valve replacement through upper mini-sternotomy. To improve the surgical view without enlargement of the incision, two small additional incisions are performed for both arterial and atrial cannulation. We have used the modified technique in 60 patients without sternal infection or other surgical complications and with good cosmetic results. Cardiac surgery - Aortic valve replacement - Minimally invasive approach.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Voluntary methadone administration for the purpose of sedation eventually resulting in the infant's death is extremely infrequent, though it has been observed. In this report, we describe an autopsy case pertaining to a 32-month-old infant who was repeatedly exposed to methadone by his parents. Autopsy revealed a coarctation of the aorta with a focal stenosis located at the junction of the distal aortic arch and the descending aorta. Left ventricular hypertrophy was also observed. Both these findings were considered to not have played a role in the child's death. Methadone was detected in the femoral blood (0.633 mg/l), urine (5.25 mg/l), bile (2.64 mg/l), and gastric contents (1.08 mg). A segmental hair analysis showed the presence of methadone and morphine in both the proximal and distal portion of the lock. Methadone was also detected in nail samples. A segmental hair analysis performed on the younger brother of the deceased revealed the presence of methadone and morphine in both the proximal and distal segments, as well as the presence of 6-monoacetylmorphine exclusively in the distal portion. Though the parents denied any involvement in methadone administration or exposure for the purpose of sedation, the manner of death was listed as homicide. The case emphasizes the usefulness of hair analysis to identify threatening situations for the children of drug-dependent parents and possibly support measures by the authorities to recognize and intervene in these potentially fatal situations.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Thoracic aortic dissection (TAD) has a very high mortality rate and is often missed due to the atypical presentation of patients. We present a case of a man with chronic hypertension, atrial fibrillation (AF) (on regular warfarin) and a previous endovascular aneurysm repair (EVAR), who presented with dyspepsia and was incidentally found to have a ruptured distal thoracic aneurysm on imaging with no obvious clinical signs on examination, nor abnormalities on admission chest x-ray (CXR).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

International audience

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVES: Due to the high prevalence of renal failure in transcatheter aortic valve replacement (TAVR) candidates, a non-contrast MR technique is desirable for pre-procedural planning. We sought to evaluate the feasibility of a novel, non-contrast, free-breathing, self-navigated three-dimensional (SN3D) MR sequence for imaging the aorta from its root to the iliofemoral run-off in comparison to non-contrast two-dimensional-balanced steady-state free-precession (2D-bSSFP) imaging. METHODS: SN3D [field of view (FOV), 220-370 mm(3); slice thickness, 1.15 mm; repetition/echo time (TR/TE), 3.1/1.5 ms; and flip angle, 115°] and 2D-bSSFP acquisitions (FOV, 340 mm; slice thickness, 6 mm; TR/TE, 2.3/1.1 ms; flip angle, 77°) were performed in 10 healthy subjects (all male; mean age, 30.3 ± 4.3 yrs) using a 1.5-T MRI system. Aortic root measurements and qualitative image ratings (four-point Likert-scale) were compared. RESULTS: The mean effective aortic annulus diameter was similar for 2D-bSSFP and SN3D (26.7 ± 0.7 vs. 26.1 ± 0.9 mm, p = 0.23). The mean image quality of 2D-bSSFP (4; IQR 3-4) was rated slightly higher (p = 0.03) than SN3D (3; IQR 2-4). The mean total acquisition time for SN3D imaging was 12.8 ± 2.4 min. CONCLUSIONS: Our results suggest that a novel SN3D sequence allows rapid, free-breathing assessment of the aortic root and the aortoiliofemoral system without administration of contrast medium. KEY POINTS: • The prevalence of renal failure is high among TAVR candidates. • Non-contrast 3D MR angiography allows for TAVR procedure planning. • The self-navigated sequence provides a significantly reduced scanning time.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Cardiovascular diseases (CVDs) have reached an epidemic proportion in the US and worldwide with serious consequences in terms of human suffering and economic impact. More than one third of American adults are suffering from CVDs. The total direct and indirect costs of CVDs are more than $500 billion per year. Therefore, there is an urgent need to develop noninvasive diagnostics methods, to design minimally invasive assist devices, and to develop economical and easy-to-use monitoring systems for cardiovascular diseases. In order to achieve these goals, it is necessary to gain a better understanding of the subsystems that constitute the cardiovascular system. The aorta is one of these subsystems whose role in cardiovascular functioning has been underestimated. Traditionally, the aorta and its branches have been viewed as resistive conduits connected to an active pump (left ventricle of the heart). However, this perception fails to explain many observed physiological results. My goal in this thesis is to demonstrate the subtle but important role of the aorta as a system, with focus on the wave dynamics in the aorta.

The operation of a healthy heart is based on an optimized balance between its pumping characteristics and the hemodynamics of the aorta and vascular branches. The delicate balance between the aorta and heart can be impaired due to aging, smoking, or disease. The heart generates pulsatile flow that produces pressure and flow waves as it enters into the compliant aorta. These aortic waves propagate and reflect from reflection sites (bifurcations and tapering). They can act constructively and assist the blood circulation. However, they may act destructively, promoting diseases or initiating sudden cardiac death. These waves also carry information about the diseases of the heart, vascular disease, and coupling of heart and aorta. In order to elucidate the role of the aorta as a dynamic system, the interplay between the dominant wave dynamic parameters is investigated in this study. These parameters are heart rate, aortic compliance (wave speed), and locations of reflection sites. Both computational and experimental approaches have been used in this research. In some cases, the results are further explained using theoretical models.

The main findings of this study are as follows: (i) developing a physiologically realistic outflow boundary condition for blood flow modeling in a compliant vasculature; (ii) demonstrating that pulse pressure as a single index cannot predict the true level of pulsatile workload on the left ventricle; (iii) proving that there is an optimum heart rate in which the pulsatile workload of the heart is minimized and that the optimum heart rate shifts to a higher value as aortic rigidity increases; (iv) introducing a simple bio-inspired device for correction and optimization of aortic wave reflection that reduces the workload on the heart; (v) deriving a non-dimensional number that can predict the optimum wave dynamic state in a mammalian cardiovascular system; (vi) demonstrating that waves can create a pumping effect in the aorta; (vii) introducing a system parameter and a new medical index, Intrinsic Frequency, that can be used for noninvasive diagnosis of heart and vascular diseases; and (viii) proposing a new medical hypothesis for sudden cardiac death in young athletes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Diabetes mellitus type 1 is the most common endocrine metabolic disorder occurring in childhood and adolescence due to the autoimmune destruction of pancreatic beta cells as a result of various environmental factors interacting with an underlying genetic predisposition. Diabetes is a risk factor for early onset atherosclerosis, and the high mortality rate seen in these patients is partially related to cardiovascular diseases. Objectives: This study was conducted to compare mean platelet volume as a marker of early atherosclerosis with aortic intima-media thickness in children with type 1 diabetes and to identify its correlation with known cardiovascular risk factors. Patients and Methods: The study included 27 patients between age range of 6 and 17 years that were diagnosed with type 1 diabetes and 30 healthy children of the same age range who did not have any chronic disease. In both groups, we used the color Doppler ultrasound to measure children’s aortic intima-media thickness and identify their mean platelet volumes. Results: There was no significant difference between the groups regarding gender distribution, age, High-Density Lipoprotein (HDL) and Low-Density Lipoprotein (LDL) cholesterol levels (P > 0.05). Also no significant difference could be documented between the patient and control groups regarding the aortic intima-media thickness and mean platelet volume (P > 0.05). However, there was a significant correlation between aortic intima-media thickness and mean platelet volume (r = 0.351; P < 0.05). Conclusions: In the present study, there was no evidence of early atherosclerosis in children with type 1 diabetes. However, mean platelet volume having a significant correlation with aortic intima-media thickness may be useful as an early marker of atherosclerosis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The factors that influence decision making in severe aortic stenosis (AS) are unknown. Our aim was to assess, in patients with severe AS, the determinants of management and prognosis in a multicenter registry that enrolled all consecutive adults with severe AS during a 1-month period. One-year follow-up was obtained in all patients and included vital status and aortic valve intervention (aortic valve replacement [AVR] and transcatheter aortic valve implantation [TAVI]). A total of 726 patients were included, mean age was 77.3 ± 10.6 years, and 377 were women (51.8%). The most common management was conservative therapy in 468 (64.5%) followed by AVR in 199 (27.4%) and TAVI in 59 (8.1%). The strongest association with aortic valve intervention was patient management in a tertiary hospital with cardiac surgery (odds ratio 2.7, 95% confidence interval 1.8 to 4.1, p <0.001). The 2 main reasons to choose conservative management were the absence of significant symptoms (136% to 29.1%) and the presence of co-morbidity (128% to 27.4%). During 1-year follow-up, 132 patients died (18.2%). The main causes of death were heart failure (60% to 45.5%) and noncardiac diseases (46% to 34.9%). One-year survival for patients treated conservatively, with TAVI, and with AVR was 76.3%, 94.9%, and 92.5%, respectively, p <0.001. One-year survival of patients treated conservatively in the absence of significant symptoms was 97.1%. In conclusion, most patients with severe AS are treated conservatively. The outcome in asymptomatic patients managed conservatively was acceptable. Management in tertiary hospitals is associated with valve intervention. One-year survival was similar with both interventional strategies.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Despite current recommendations, a high percentage of patients with severe symptomatic aortic stenosis are managed conservatively. The aim of this study was to study symptomatic patients undergoing conservative management from the IDEAS registry, describing their baseline clinical characteristics, mortality, and the causes according to the reason for conservative management. Consecutive patients with severe aortic stenosis diagnosed at 48 centers during January 2014 were included. Baseline clinical characteristics, echocardiographic data, Charlson index, and EuroSCORE-II were registered, including vital status and performance of valve intervention during one-year follow-up. For the purpose of this substudy we assessed symptomatic patients undergoing conservative management, including them in 5 groups according to the reason for performing conservative management [I: comorbidity/frailty (128, 43.8%); II: dementia 18 (6.2%); III: advanced age 34 (11.6%); IV: patients’ refusal 62 (21.2%); and V: other reasons 50 (17.1%)]. We included 292 patients aged 81.5 ± 9 years. Patients from group I had higher Charlson index (4 ± 2.3), higher EuroSCORE-II (7.5 ± 6), and a higher overall (42.2%) and non-cardiac mortality (16.4%) than the other groups. In contrast, patients from group III had fewer comorbidities, lower EuroSCORE-II (4 ± 2.5), and low overall (20.6%) and non-cardiac mortality (5.9%). Patients with severe symptomatic aortic stenosis managed conservatively have different baseline characteristics and clinical course according to the reason for performing conservative management. A prospective assessment of comorbidity and other geriatric syndromes might contribute to improve therapeutic strategy in this clinical setting.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study is to describe the characteristics of infective endocarditis (IE) after transcatheter aortic valve implantation (TAVI). This study was performed using the GAMES database, a national prospective registry of consecutive patients with IE in 26 Spanish hospitals. Of the 739 cases of IE diagnosed during the study, 1.3% were post-TAVI IE, and these 10 cases, contributed by five centres, represented 1.1% of the 952 TAVIs performed. Mean age was 80 years. All valves were implanted transfemorally. IE appeared a median of 139 days after implantation. The mean age-adjusted Charlson comorbidity index was 5.45. Chronic kidney disease was frequent (five patients), as were atrial fibrillation (five patients), chronic obstructive pulmonary disease (four patients), and ischaemic heart disease (four patients). Six patients presented aortic valve involvement, and four only mitral valve involvement; the latter group had a higher percentage of prosthetic mitral valves (0% vs. 50%). Vegetations were found in seven cases, and four presented embolism. One patient underwent surgery. Five patients died during follow-up: two of these patients died during the admission in which the valve was implanted. Conclusions: IE is a rare but severe complication after TAVI which affects about 1% of patients and entails a relatively high mortality rate. IE occurred during the first year in nine of the 10 patients.