948 resultados para Angular acceleration


Relevância:

10.00% 10.00%

Publicador:

Resumo:

In this work, we describe the process of teleportation between Alice in an inertial frame, and Rob who is in uniform acceleration with respect to Alice. The fidelity of the teleportation is reduced due to Davies-Unruh radiation in Rob's frame. In so far as teleportation is a measure of entanglement, our results suggest that quantum entanglement is degraded in non-inertial frames. We discuss this reduction in fidelity for both bosonic and fermionic resources.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Glucocorticoids are an important cause of secondary osteoporosis in humans, which decreases bone quality and leads to fractures. Mechanical stimulation in the form of low-intensity and high-frequency vibration seems to be able to prevent bone loss and to stimulate bone formation. The objective of this study was to evaluate the effects of mechanical vibration on bone structure in rats treated with glucocorticoids. Thirty 3-month-old adult male Wistar rats were randomized to three groups: control (C), glucocorticoid (G), and glucocorticoid with vibration (CV). The G and GV groups received 3.5 mg/kg/day of methylprednisolone 5 days/week for a duration of 9 weeks, and the C group received vehicle (saline solution) during the same period. The CV group was vibrated on a special platform for 30 min per day, 5 days per week during the experiment. The platform was set to provide a vertical acceleration of 1 G and a frequency of 60 Hz. Skeletal bone mass was evaluated by total body densitometry (DXA). Fracture load threshold, undecalcified bone histomorphometry, and bone volume were measured in tibias. Glucocorticoids induced a significantly lower weight gain (-9.7%) and reduced the bone mineral content (-9.2%) and trabecular number (-41.8%) and increased the trabecular spacing (+98.0%) in the G group, when compared to the control (C). Vibration (CV) was able to significantly preserve (29.2%) of the trabecular number and decrease the trabecular spacing (+ 26.6%) compared to the G group, although these parameters did not reach C group values. The fracture load threshold was not different between groups, but vibration significantly augmented the bone volume of the tibia by 21.4% in the CV group compared to the C group. Our study demonstrated that low-intensity and high-frequency mechanical vibration was able to partially inhibit the deleterious consequences of glucocorticoids on bone structure in rats. (C) 2010 Elsevier Inc. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim of this study was to evaluate (1) the prevalence of periodic leg movements during sleep (PLMs) in a consecutive sample of congestive heart failure (CHF) outpatients; (2) the presence of correlation between PLMs, subjective daytime sleepiness, and sleep architecture; and (3) the heart rate response to PLMs in CHF. Seventy-nine [50 men, age 59 +/- 11 years, body mass index (BMI) 26 +/- 5 kg/m(2)] consecutive adult stable outpatients with CHF [left ventricular ejection fraction (LVEF) 36 +/- 6%] were prospectively evaluated. The patients underwent assessment of echocardiography, sleepiness (Epworth Scale), and overnight in-lab polysomnography. Fifteen patients (19%) had PLM index > 5. These subjects were similar in sex distribution, BMI, subjective somnolence, LVEF, and apnea-hypopnea index (AHI), but were significantly older than subjects without PLMs. Sleep architecture was similar in subjects with and without PLMs. There was a small but significant elevation of heart rate after PLMs (80.1 +/- 9.4 vs. 81.5 +/- 9.2; p < 0.001). The cardiac acceleration was also present in absence of electroencephalogram activation. The prevalence of PLMs in consecutive sample of adult CHF outpatients was 19%. There were no differences in subjective daytime sleepiness, sleep architecture, AHI, and severity of CHF in subjects with and without PLMs. PLMs caused a small but statistically significant cardiac acceleration.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

To understand the dynamic mechanisms of the mechanical milling process in a vibratory mill, it is necessary to determine the characteristics of the impact forces associated with the collision events. However, it is difficult to directly measure the impact force in an operating mill. This paper describes an inverse technique for the prediction of impact forces from acceleration measurements on a vibratory ball mill. The characteristics of the vibratory mill have been investigated by the modal testing technique, and its system modes have been identified. In the modelling of the system vibration response to the impact forces, two modal equations have been used to describe the modal responses. The superposition of the modal responses gives rise to the total response of the system. A method based on an optimisation approach has been developed to predict the impact forces by minimising the difference between the measured acceleration of the vibratory ball mill and the predicted acceleration from the solution of the modal equations. The predicted and measured impact forces are in good agreement. Copyright (C) 1996 Elsevier Science Ltd.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objective. The objective of this study was to evaluate, using computed tomography, correlations between Hyrax appliance opening and post-SARPE skeletal changes. Study design. Fifteen patients underwent SARPE according to a specific protocol and were followed. Linear and angular measurements of the anterior, intermediate, and posterior portions of the maxilla were evaluated. The correlation between maxillary expansion and appliance opening was investigated. Results. Significant overall expansion was observed. In the anterior and intermediate portions of the maxilla, the increase in maxillary width was greater than that observed in the posterior portion. The degree of appliance opening was significantly greater than that of the skeletal expansion. Also, no linear correlation between appliance opening and regional maxillary expansion was established. Conclusion. The transverse expansion of the maxilla was less than uniform. The lack of linear correlation between appliance opening and skeletal expansion is attributable to multiple factors, including those related to the device, the surgical technique, and the craniofacial deformity itself. (Oral Surg Oral Med Oral Pathol Oral Radiol Endod 2008; 106: 812-819)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Molecular dynamics simulations are used to study the interaction of low-energy Ar atoms with the Ni(001) surface, Angular scattering distributions, in and out of the plane of incidence, are investigated as a function of incident energy, angles of incidence, crystallographic orientation of the incident beam and surface temperature. The results show a clear transition to the structure scattering regime at around 2 eV. However, at lower energies, two sub-regimes are revealed by the simulations, Far energies up to 250 meV, scattering is mainly diffuse, and significant trapping on the surface is observed, At energies above this level, lobular patterns start to form and trapping decreases with the increase in energy, Generally, there is a weak temperature dependence, but variations in the angle of incidence and/or changes in the crystallographic direction, generate significant changes in the scattering patterns.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This study aimed to quantify the efficiency and smoothness of voluntary movement in Huntington's disease (HD) by the use of a graphics tablet that permits analysis of movement profiles. In particular, we aimed to ascertain whether a concurrent task (digit span) would affect the kinematics of goal-directed movements. Twelve patients with HD and their matched controls performed 12 vertical zig-zag movements, with both left and right hands (with and without the concurrent task), to large or small circular targets over long or short extents. The concurrent task was associated with shorter movement times and reduced right-hand superiority. Patients with HD were overall slower, especially with long strokes, and had similar peak velocities for both small and large targets, so that controls could better accommodate differences in target size. Patients with HD spent more time decelerating, especially with small targets, whereas controls allocated more nearly equal proportions of time to the acceleration and deceleration phases of movement, especially with large targets. Short strokes were generally less force inefficient than were long strokes, especially so for either hand in either group in the absence of the concurrent task, and for the right hand in its presence. With the concurrent task, however, the left hand's behavior changed differentially for the two groups; for patients with HD, it became more force efficient with short strokes and even less efficient with long strokes, whereas for controls, it became more efficient with long strokes. Controls may be able to divert attention away from the inferior left hand, increasing its automaticity, whereas patients with HD, because of disease, may be forced to engage even further online visual control under the demands of a concurrent task. Patients with HD may perhaps become increasingly reliant on terminal visual guidance, which indicates an impairment in constructing and refining an internal representation of the movement necessary for its. effective execution. Basal ganglia dysfunction may impair the ability to use internally generated cues to guide movement.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The suprathermal particles, electrons and protons, coming from the magnetosphere and precipitating into the high-latitude atmosphere are an energy source of the Earth's ionosphere. They interact with ambient thermal gas through inelastic and elastic collisions. The physical quantities perturbed by these precipitations, such as the heating rate, the electron production rate, or the emission intensities, can be provided in solving the kinetic stationary Boltzmann equation. This equation yields particle fluxes as a function of altitude, energy, and pitch angle. While this equation has been solved through different ways for the electron transport and fully tested, the proton transport is more complicated. Because of charge-changing reactions, the latter is a set of two-coupled transport equations that must be solved: one for protons and the other for H atoms. We present here a new approach that solves the multistream proton/hydrogen transport equations encompassing the collision angular redistributions and the magnetic mirroring effect. In order to validate our model we discuss the energy conservation and we compare with another model under the same inputs and with rocket observations. The influence of the angular redistributions is discussed in a forthcoming paper.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Rapid shoulder movement is preceded by contraction of the abdominal muscles to prepare the body for the expected disturbance to postural equilibrium and spinal stability provoked by the reactive forces resulting from the movement. The magnitude of the reactive forces is proportional to the inertia of the limb. The aim of the study was to investigate if changes in the reaction time latency of the abdominal muscles was associated with variation in the magnitude of the reactive forces resulting from variation in limb speed. Fifteen participants performed shoulder flexion at three different speeds (fast, natural and slow). The onset of EMG of the abdominal muscles, erector spinae and anterior deltoid (AD) was recorded using a combination of fine-wire and surface electrodes. Mean and peak velocity was recorded for each limb movement speed for five participants. The onset of transversus abdominis (TrA) EMG preceded the onset of AD in only the fast movement condition. No significant difference in reaction time latency was recorded between the fast and natural speed conditions for all muscles. The reaction time of each of the abdominal muscles relative to AD was significantly delayed with the slow movement compared to the other two speeds. The results indicate that the reaction time latency of the trunk muscles is influenced by limb inertia only with limb movement below a threshold velocity.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background and Aim: It is unclear to what extent diabetes modulates the ageing-related adaptations of cardiac geometry and function. Methods and Results: We examined 1005 adults, aged 25-74 years, from a population-based survey at baseline in 1994/5 and at follow-up in 2004/5. We compared persistently non-diabetic individuals (ND; no diabetes at baseline and at follow-up, n = 833) with incident (ID; non-diabetic at baseline and diabetic at follow-up, n = 36) and with prevalent diabetics (PD; diabetes at baseline and follow-up examination, n = 21). Left ventricular (LV) geometry and function were evaluated by echocardiography. Statistical analyses were performed with multivariate linear regression models. Over ten years the PD group displayed a significantly stronger relative increase of LV mass (+9.34% vs. +23.7%) that was mediated by a more pronounced increase of LV end-diastolic diameter (+0% vs. +6.95%) compared to the ND group. In parallel, LA diameter increased (+4.50% vs. +12.7%), whereas ejection fraction decreased (+3.02% vs. -4.92%) more significantly in the PD group. Moreover, at the follow-up examination the PD and ID groups showed a significantly worse diastolic function, indicated by a higher E/EM ratio compared with the ND group (11.6 and 11.8 vs. 9.79, respectively). Conclusions: Long-standing diabetes was associated with an acceleration of age-related changes of left ventricular geometry accumulating in an eccentric remodelling of the left ventricle. Likewise, echocardiographic measures of systolic and diastolic ventricular function deteriorated more rapidly in individuals with diabetes. (C) 2009 Elsevier B.V. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Study design: Single-blind randomized, controlled clinical study. Objectives: To evaluate, using kinematic gait analysis, the results obtained from gait training on a treadmill with body weight support versus those obtained with conventional gait training and physiotherapy. Setting: Thirty patients with sequelae from traumatic incomplete spinal cord injuries at least 12 months earlier; patients were able to walk and were classified according to motor function as ASIA (American Spinal Injury Association) impairment scale C or D. Methods: Patients were divided randomly into two groups of 15 patients by the drawing of opaque envelopes: group A (weight support) and group B (conventional). After an initial assessment, both groups underwent 30 sessions of gait training. Sessions occurred twice a week, lasted for 30min each and continued for four months. All of the patients were evaluated by a single blinded examiner using movement analysis to measure angular and linear kinematic gait parameters. Six patients (three from group A and three from group B) were excluded because they attended fewer than 85% of the training sessions. Results: There were no statistically significant differences in intra-group comparisons among the spatial-temporal variables in group B. In group A, the following significant differences in the studied spatial-temporal variables were observed: increases in velocity, distance, cadence, step length, swing phase and gait cycle duration, in addition to a reduction in stance phase. There were also no significant differences in intra-group comparisons among the angular variables in group B. However, group A achieved significant improvements in maximum hip extension and plantar flexion during stance. Conclusion: Gait training with body weight support was more effective than conventional physiotherapy for improving the spatial-temporal and kinematic gait parameters among patients with incomplete spinal cord injuries. Spinal Cord (2011) 49, 1001-1007; doi:10.1038/sc.2011.37; published online 3 May 2011

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: Several attempts to determine the transit time of a high dose rate (HDR) brachytherapy unit have been reported in the literature with controversial results. The determination of the source speed is necessary to accurately calculate the transient dose in brachytherapy treatments. In these studies, only the average speed of the source was measured as a parameter for transit dose calculation, which does not account for the realistic movement of the source, and is therefore inaccurate for numerical simulations. The purpose of this work is to report the implementation and technical design of an optical fiber based detector to directly measure the instantaneous speed profile of a (192)Ir source in a Nucletron HDR brachytherapy unit. Methods: To accomplish this task, we have developed a setup that uses the Cerenkov light induced in optical fibers as a detection signal for the radiation source moving inside the HDR catheter. As the (192)Ir source travels between two optical fibers with known distance, the threshold of the induced signals are used to extract the transit time and thus the velocity. The high resolution of the detector enables the measurement of the transit time at short separation distance of the fibers, providing the instantaneous speed. Results: Accurate and high resolution speed profiles of the 192Ir radiation source traveling from the safe to the end of the catheter and between dwell positions are presented. The maximum and minimum velocities of the source were found to be 52.0 +/- 1.0 and 17.3 +/- 1:2 cm/s. The authors demonstrate that the radiation source follows a uniformly accelerated linear motion with acceleration of vertical bar a vertical bar = 113 cm/s(2). In addition, the authors compare the average speed measured using the optical fiber detector to those obtained in the literature, showing deviation up to 265%. Conclusions: To the best of the authors` knowledge, the authors directly measured for the first time the instantaneous speed profile of a radiation source in a HDR brachytherapy unit traveling from the unit safe to the end of the catheter and between interdwell distances. The method is feasible and accurate to implement on quality assurance tests and provides a unique database for efficient computational simulations of the transient dose. (C) 2010 American Association of Physicists in Medicine. [DOI: 10.1118/1.3483780]

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objective: The purpose of this study was to investigate the reliability and validity of photogrammetry in measuring the lateral spinal inclination angles. Methods: Forty subjects (32 female and 8 males) with a mean age of 23.4 +/- 11.2 years had their scoliosis evaluated by radiographs of their trunk, determined by the Cobb angle method, and by photogrammetry. The statistical methods used included Cronbach alpha, Pearson/Spearman correlation coefficients, and regression analyses. Results: The Cronbach a values showed that the photogrammetric measures showed high internal consistency, which indicated that the sample was bias free. The radiograph method showed to be more precise with intrarater reliabilities of 0.936, 0.975, and 0.945 for the thoracic, lumbar, and thoracolumbar curves, respectively, and interrater reliabilities of 0.942 and 0.879 for the angular measures of the thoracic and thoracolumbar segments, respectively. The regression analyses revealed a high determination coefficient although limited to the adjusted linear model between the radiographic and photographic measures. It was found that with more severe scoliosis, the lateral curve measures obtained with the photogrammetry were for the thoracic and lumbar regions (R = 0.619 and 0.551). Conclusions: The photogrammetric measures were found to be reproducible in this study and could be used as Supplementary information to decrease the number of radiographs necessary for the monitoring of scoliosis. (J Manipulative Physiol Ther 2009;32:423-430)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objective: To introduce a new coupling system between screw driver and interference screw, and biomechanical tests that validate the safety of its application. Methods: The new system was submitted to biomechanical torsion assays. Two types of analysis were performed: maximum torque of manual insertion of the screws into bovine bone; destructive assays of torsion of the system using an INSTRON 55MT machine. The same tests were also performed on a control group, using a commercially available interference screw coupling system (Acufex (R)). Results: In the tests on manual insertion of screws in bovine femurs, the average values found with a digital torque meter were 1.958 N/m for Acufex (R) and 2.563 N/m for FMRP. Considering p>0.05, there were no statistical differences between the two groups (p=0.02) in the values for maximum torque of insertion, in the two systems studied. The average values for maximum torque of torsion resisted by the screw were 15N/m for the Acufex (R) screw and 13N/m for the FMRP screw, again with no statistical differences between the two groups (p>0.05). In the evaluation of angular deformation, there was also no significant difference between the two screw types (p=0.15). Conclusion: The new coupling system for interference screws developed at FMRP-USP revealed a torsion resistance that is comparable with the system already available on the market and regulated for international use.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In adolescent idiopathic scoliosis (AIS) there has been a shift towards increasing the number of implants and pedicle screws, which has not been proven to improve cosmetic correction. To evaluate if increasing cost of instrumentation correlates with cosmetic correction using clinical photographs. 58 Lenke 1A and B cases from a multicenter AIS database with at least 3 months follow-up of clinical photographs were used for analysis. Cosmetic parameters on PA and forward bending photographs included angular measurements of trunk shift, shoulder balance, rib hump, and ratio measurements of waist line asymmetry. Pre-op and follow-up X-rays were measured for coronal and sagittal deformity parameters. Cost density was calculated by dividing the total cost of instrumentation by the number of vertebrae being fused. Linear regression and spearman`s correlation were used to correlate cost density to X-ray and photo outcomes. Three independent observers verified radiographic and cosmetic parameters for inter/interobserver variability analysis. Average pre-op Cobb angle and instrumented correction were 54A degrees (SD 12.5) and 59% (SD 25) respectively. The average number of vertebrae fused was 10 (SD 1.9). The total cost of spinal instrumentation ranged from $6,769 to $21,274 (Mean $12,662, SD $3,858). There was a weak positive and statistically significant correlation between Cobb angle correction and cost density (r = 0.33, p = 0.01), and no correlation between Cobb angle correction of the uninstrumented lumbar spine and cost density (r = 0.15, p = 0.26). There was no significant correlation between all sagittal X-ray measurements or any of the photo parameters and cost density. There was good to excellent inter/intraobserver variability of all photographic parameters based on the intraclass correlation coefficient (ICC 0.74-0.98). Our method used to measure cosmesis had good to excellent inter/intraobserver variability, and may be an effective tool to objectively assess cosmesis from photographs. Since increasing cost density only improves mildly the Cobb angle correction of the main thoracic curve and not the correction of the uninstrumented spine or any of the cosmetic parameters, one should consider the cost of increasing implant density in Lenke 1A and B curves. In the area of rationalization of health care expenses, this study demonstrates that increasing the number of implants does not improve any relevant cosmetic or radiographic outcomes.