728 resultados para Analgesia Intrapleural


Relevância:

10.00% 10.00%

Publicador:

Resumo:

A 37-year-old man with advanced Friedreich's ataxia was referred to our emergency department with acute exacerbated abdominal pain of unclear aetiology. Laboratory tests showed slightly increased inflammatory parameters, elevated troponin and B-type natriuretic peptide, as well as minimal proteinuria. Transthoracic echocardiography revealed a pre-existing dilated cardiomyopathy. Abdominal sonography showed no pathological alterations. Owing to persistent pain under analgesia, a contrast-enhanced CT-abdomen was performed, which revealed a non-homogeneous perfusion deficit of the right kidney, although neither abdominal vascular alteration, cardiac thrombus, deep vein thrombosis nor a patent foramen ovale could be detected. Taking all clinical and radiological results into consideration, the current incident was diagnosed as a thromboembolic kidney infarction. As a consequence, lifelong oral anticoagulation was initiated.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

REASONS FOR PERFORMING STUDY: Evidence-based information is limited on distribution of local anaesthetic solution following perineural analgesia of the palmar (Pa) and palmar metacarpal (PaM) nerves in the distal aspect of the metacarpal (Mc) region ('low 4-point nerve block'). OBJECTIVES: To demonstrate the potential distribution of local anaesthetic solution after a low 4-point nerve block using a radiographic contrast model. METHODS: A radiodense contrast medium was injected subcutaneously over the medial or the lateral Pa nerve at the junction of the proximal three-quarters and distal quarter of the Mc region (Pa injection) and over the ipsilateral PaM nerve immediately distal to the distal aspect of the second or fourth Mc bones (PaM injection) in both forelimbs of 10 mature horses free from lameness. Radiographs were obtained 0, 10 and 20 min after injection and analysed subjectively and objectively. Methylene blue and a radiodense contrast medium were injected in 20 cadaver limbs using the same techniques. Radiographs were obtained and the limbs dissected. RESULTS: After 31/40 (77.5%) Pa injections, the pattern of the contrast medium suggested distribution in the neurovascular bundle. There was significant proximal diffusion with time, but the main contrast medium patch never progressed proximal to the mid-Mc region. The radiological appearance of 2 limbs suggested that contrast medium was present in the digital flexor tendon sheath (DFTS). After PaM injections, the contrast medium was distributed diffusely around the injection site in the majority of the limbs. In cadaver limbs, after Pa injections, the contrast medium and the dye were distributed in the neurovascular bundle in 8/20 (40%) limbs and in the DFTS in 6/20 (30%) of limbs. After PaM injections, the contrast and dye were distributed diffusely around the injection site in 9/20 (45%) limbs and showed diffuse and tubular distribution in 11/20 (55%) limbs. CONCLUSIONS AND POTENTIAL RELEVANCE: Proximal diffusion of local anaesthetic solution after a low 4-point nerve block is unlikely to be responsible for decreasing lameness caused by pain in the proximal Mc region. The DFTS may be penetrated inadvertently when performing a low 4-point nerve block.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Substantial variation exists in response to standard doses of codeine ranging from poor analgesia to life-threatening central nervous system (CNS) depression. We aimed to discover the genetic markers predictive of codeine toxicity by evaluating the associations between polymorphisms in cytochrome P450 2D6 (CYP2D6), UDP-glucuronosyltransferase 2B7 (UGT2B7), P-glycoprotein (ABCB1), mu-opioid receptor (OPRM1), and catechol O-methyltransferase (COMT) genes, which are involved in the codeine pathway, and the symptoms of CNS depression in 111 breastfeeding mothers using codeine and their infants. A genetic model combining the maternal risk genotypes in CYP2D6 and ABCB1 was significantly associated with the adverse outcomes in infants (odds ratio (OR) 2.68; 95% confidence interval (CI) 1.61-4.48; P(trend) = 0.0002) and their mothers (OR 2.74; 95% CI 1.55-4.84; P(trend) = 0.0005). A novel combination of the genetic and clinical factors predicted 87% of the infant and maternal CNS depression cases with a sensitivity of 80% and a specificity of 87%. Genetic markers can be used to improve the outcome of codeine therapy and are also probably important for other opioids sharing common biotransformation pathways.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

To quantify the dose of pancuronium required to obtain moderate neuromuscular blockade as monitored by acceleromyography (NMB(mod) : train-of-four count of ≤2) as a part of a balanced anaesthetic protocol in pigs used in cardiovascular research.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Inflammatory reactions involve a network of chemical and molecular signals that initiate and maintain host response. In inflamed tissue, immune system cells generate opioid peptides that contribute to potent analgesia by acting on specific peripheral sensory neurons. In this study, we show that opioids also modulate immune cell function in vitro and in vivo. By binding to its specific receptor, the opioid receptor-specific ligand DPDPE triggers monocyte adhesion. Integrins have a key role in this process, as adhesion is abrogated in cells treated with specific neutralizing anti-alpha5beta1 integrin mAb. We found that DPDPE-triggered monocyte adhesion requires PI3Kgamma activation and involves Src kinases, the guanine nucleotide exchange factor Vav-1, and the small GTPase Rac1. DPDPE also induces adhesion of pertussis toxin-treated cells, indicating involvement of G proteins other than Gi. These data show that opioids have important implications in regulating leukocyte trafficking, adding a new function to their known effects as immune response modulators.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND: In contrast to hypnosis, there is no surrogate parameter for analgesia in anesthetized patients. Opioids are titrated to suppress blood pressure response to noxious stimulation. The authors evaluated a novel model predictive controller for closed-loop administration of alfentanil using mean arterial blood pressure and predicted plasma alfentanil concentration (Cp Alf) as input parameters. METHODS: The authors studied 13 healthy patients scheduled to undergo minor lumbar and cervical spine surgery. After induction with propofol, alfentanil, and mivacurium and tracheal intubation, isoflurane was titrated to maintain the Bispectral Index at 55 (+/- 5), and the alfentanil administration was switched from manual to closed-loop control. The controller adjusted the alfentanil infusion rate to maintain the mean arterial blood pressure near the set-point (70 mmHg) while minimizing the Cp Alf toward the set-point plasma alfentanil concentration (Cp Alfref) (100 ng/ml). RESULTS: Two patients were excluded because of loss of arterial pressure signal and protocol violation. The alfentanil infusion was closed-loop controlled for a mean (SD) of 98.9 (1.5)% of presurgery time and 95.5 (4.3)% of surgery time. The mean (SD) end-tidal isoflurane concentrations were 0.78 (0.1) and 0.86 (0.1) vol%, the Cp Alf values were 122 (35) and 181 (58) ng/ml, and the Bispectral Index values were 51 (9) and 52 (4) before surgery and during surgery, respectively. The mean (SD) absolute deviations of mean arterial blood pressure were 7.6 (2.6) and 10.0 (4.2) mmHg (P = 0.262), and the median performance error, median absolute performance error, and wobble were 4.2 (6.2) and 8.8 (9.4)% (P = 0.002), 7.9 (3.8) and 11.8 (6.3)% (P = 0.129), and 14.5 (8.4) and 5.7 (1.2)% (P = 0.002) before surgery and during surgery, respectively. A post hoc simulation showed that the Cp Alfref decreased the predicted Cp Alf compared with mean arterial blood pressure alone. CONCLUSION: The authors' controller has a similar set-point precision as previous hypnotic controllers and provides adequate alfentanil dosing during surgery. It may help to standardize opioid dosing in research and may be a further step toward a multiple input-multiple output controller.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

During general anesthesia drugs are administered to provide hypnosis, ensure analgesia, and skeletal muscle relaxation. In this paper, the main components of a newly developed controller for skeletal muscle relaxation are described. Muscle relaxation is controlled by administration of neuromuscular blocking agents. The degree of relaxation is assessed by supramaximal train-of-four stimulation of the ulnar nerve and measuring the electromyogram response of the adductor pollicis muscle. For closed-loop control purposes, a physiologically based pharmacokinetic and pharmacodynamic model of the neuromuscular blocking agent mivacurium is derived. The model is used to design an observer-based state feedback controller. Contrary to similar automatic systems described in the literature this controller makes use of two different measures obtained in the train-of-four measurement to maintain the desired level of relaxation. The controller is validated in a clinical study comparing the performance of the controller to the performance of the anesthesiologist. As presented, the controller was able to maintain a preselected degree of muscle relaxation with excellent precision while minimizing drug administration. The controller performed at least equally well as the anesthesiologist.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND: Ilioinguinal and iliohypogastric nerve blocks may be used in the diagnosis of chronic groin pain or for analgesia for hernia repair. This study describes a new ultrasound-guided approach to these nerves and determines its accuracy using anatomical dissection control. METHODS: After having tested the new method in a pilot cadaver, 10 additional embalmed cadavers were used to perform 37 ultrasound-guided blocks of the ilioinguinal and iliohypogastric nerve. After injection of 0.1 ml of dye the cadavers were dissected to evaluate needle position and colouring of the nerves. RESULTS: Thirty-three of the thirty-seven needle tips were located at the exact target point, in or directly at the ilioinguinal or iliohypogastric nerve. In all these cases the targeted nerve was coloured entirely. In two of the remaining four cases parts of the nerves were coloured. This corresponds to a simulated block success rate of 95%. In contrast to the standard 'blind' techniques of inguinal nerve blocks we visualized and targeted the nerves 5 cm cranial and posterior to the anterior superior iliac spine. The median diameters of the nerves measured by ultrasound were: ilioinguinal 3.0x1.6 mm, and iliohypogastric 2.9x1.6 mm. The median distance of the ilioinguinal nerve to the iliac bone was 6.0 mm and the distance between the two nerves was 10.4 mm. CONCLUSIONS: The anatomical dissections confirmed that our new ultrasound-guided approach to the ilioinguinal and iliohypogastric nerve is accurate. Ultrasound could become an attractive alternative to the 'blind' standard techniques of ilioinguinal and iliohypogastric nerve block in pain medicine and anaesthetic practice.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Recently, our study group demonstrated the usefulness of ultrasonographic guidance in ilioinguinal/iliohypogastric nerve blocks in children. As a consequence, we designed a follow-up study to evaluate the optimal volume of local anesthetic for this regional anesthetic technique. Using a modified step-up-step-down approach, with 10 children in each study group, a starting dose of 0.2 mL/kg of 0.25% levobupivacaine was administered to perform an ilioinguinal/iliohypogastric nerve block under ultrasonographic guidance. After each group of 10 patients, the results were analyzed, and if all blocks were successful, the volume of local anesthetic was decreased by 50%, and a further 10 patients were enrolled into the study. Failure to achieve a 100% success rate within a group subjected patients to an automatic increase of half the previous volume reduction to be used in the subsequent group. Using 0.2 and 0.1 mL/kg of 0.25% levobupivacaine, the success rate was 100%. With a volume of 0.05 mL/kg of 0.25% levobupivacaine, 4 of 10 children received additional analgesia because of an inadequate block. Therefore, according to the protocol, the amount was increased to 0.075 mL/kg of 0.25% levobupivacaine, where the success rate was again 100%. We conclude that ultrasonographic guidance for ilioinguinal/iliohypogastric nerve blocks in children allowed a reduction of the volume of local anesthetic to 0.075 mL/kg.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND: Hypnotic depth but not haemodynamic response to painful stimulation can be measured with various EEG-based anaesthesia monitors. We evaluated the variation of pulse plethysmography amplitude induced by an electrical tetanic stimulus (PPG variation) as a potential measure for analgesia and predictor of haemodynamic responsiveness during general anaesthesia. METHODS: Ninety-five patients, ASA I or II, were randomly assigned to five groups [Group 1: bispectral index (BIS) (range) 40-50, effect site remifentanil concentration 1 ng ml(-1);Group 2: BIS 40-50, remifentanil 2 ng ml(-1); Group 3: BIS 40-50, remifentanil 4 ng ml(-1); Group 4: BIS 25-35, remifentanil 2 ng ml(-1); Group 5: BIS 55-65, remifentanil 2 ng ml(-1)]. A 60 mA tetanic stimulus was applied for 5 s on the ulnar nerve. From the digitized pulse oximeter wave recorded on a laptop computer, linear and non-linear parameters of PPG variation during the 60 s period after stimulation were computed. The haemodynamic response to subsequent orotracheal intubation was recorded. The PPG variation was compared between groups and between responders and non-responders to intubation (anova). Variables independently predicting the response were determined by logistic regression. RESULTS: The probability of a response to tracheal intubation was 0.77, 0.47, 0.05, 0.18 and 0.52 in Groups 1-5, respectively (P<0.03). The PPG variability was significantly higher in responders than in non-responders but it did not improve the prediction of the response to tracheal intubation based on BIS level and effect site remifentanil concentration. CONCLUSION: Tetanic stimulation induced PPG variation does not reflect the analgesic state in a wide clinical range of surgical anaesthesia.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Besides providing effective analgesia, thoracic epidural anesthesia (TEA) has been shown to decrease perioperative morbidity and mortality. Because of its vasodilatory properties in association with the sympathetic blockade, however, TEA may potentially aggravate cardiovascular dysfunctions resulting from sepsis and systemic inflammatory response syndrome. The objective of the present study was to assess the effects of TEA on hemodynamics, global oxygen transport, and renal function in ovine endotoxemia. After a baseline measurement in healthy sheep (n = 18), Salmonella typhosa endotoxin was centrally infused at incremental doses to induce and maintain a hypotensive-hypodynamic circulation using an established protocol. The animals were then randomly assigned to one of two groups. In the treatment group, continuous TEA was initiated with 0.1 mL.kg of 0.125% bupivacaine at the onset of endotoxemia and maintained with 0.1 mL.kg.h. In the control group, the same amount of isotonic sodium chloride solution was injected through the epidural catheter. In the animals surviving the entire experiment (n = 7 per group), cardiac index and mean arterial pressure decreased in a dose-dependent manner during endotoxin infusion. In the TEA group, neither systemic hemodynamics nor global oxygen transport were impaired beyond the changes caused by endotoxemia itself. Urinary output was increased in the TEA group as compared with the control group (P < 0.05). In this model of endotoxic shock, TEA improved renal perfusion without affecting cardiopulmonary hemodynamics and global oxygen transport.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Avoidance of excessively deep sedation levels is problematic in intensive care patients. Electrophysiologic monitoring may offer an approach to solving this problem. Since electroencephalogram (EEG) responses to different sedation regimens vary, we assessed electrophysiologic responses to two sedative drug regimens in 10 healthy volunteers. Dexmedetomidine/remifentanil (dex/remi group) and midazolam/remifentanil (mida/remi group) were infused 7 days apart. Each combination of medications was given at stepwise intervals to reach Ramsay scores (RS) 2, 3, and 4. Resting EEG, bispectral index (BIS), and the N100 amplitudes of long-latency auditory-evoked potentials (ERP) were recorded at each level of sedation. During dex/remi, resting EEG was characterized by a recurrent high-power low-frequency pattern which became more pronounced at deeper levels of sedation. BIS Index decreased uniformly in only the dex/remi group (from 94 +/- 3 at baseline to 58 +/- 14 at RS 4) compared to the mida/remi group (from 94 +/- 2 to 76 +/- 10; P = 0.029 between groups). The ERP amplitudes decreased from 5.3 +/- 1.3 at baseline to 0.4 +/- 1.1 at RS 4 (P = 0.003) in only the mida/remi group. We conclude that ERPs in volunteers sedated with dex/remi, in contrast to mida/remi, indicate a cortical response to acoustic stimuli, even when sedation reaches deeper levels. Consequently, ERP can monitor sedation with midazolam but not with dexmedetomidine. The reverse is true for BIS.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In a surfactant-depletion model of lung injury, tidal recruitment of atelectasis and changes in shunt fraction lead to large Pao2 oscillations. We investigated the effect of these oscillations on conventional arterial blood gas (ABG) results using different sampling techniques in ventilated rabbits. In each rabbit, 5 different ventilator settings were studied, 2 before saline lavage injury and 3 after lavage injury. Ventilator settings were altered according to 5 different goals for the amplitude and mean value of brachiocephalic Pao2 oscillations, as guided by a fast responding intraarterial probe. ABG collection was timed to obtain the sample at the peak or trough of the Pao2 oscillations, or over several respiratory cycles. Before lung injury, oscillations were small and sample timing did not influence Pao2. After saline lavage, when Po2 fluctuations measured by the indwelling arterial Po2 probe confirmed tidal recruitment, Pao2 by ABG was significantly higher at peak (295 +/- 130 mm Hg) compared with trough (74 +/- 15 mm Hg) or mean (125 +/- 75 mm Hg). In early, mild lung injury after saline lavage, Pao2 can vary markedly during the respiratory cycle. When atelectasis is recruited with each breath, interpretation of changes in shunt fraction, based on conventional ABG analysis, should account for potentially large respiratory variations in arterial Po2.