993 resultados para Active tracking


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Images of myocardial strain can be used to diagnose heart disease, plan and monitor treatment, and to learn about cardiac structure and function. Three-dimensional (3D) strain is typically quantified using many magnetic resonance (MR) images obtained in two or three orthogonal planes. Problems with this approach include long scan times, image misregistration, and through-plane motion. This article presents a novel method for calculating cardiac 3D strain using a stack of two or more images acquired in only one orientation. The zHARP pulse sequence encodes in-plane motion using MR tagging and out-of-plane motion using phase encoding, and has been previously shown to be capable of computing 3D displacement within a single image plane. Here, data from two adjacent image planes are combined to yield a 3D strain tensor at each pixel; stacks of zHARP images can be used to derive stacked arrays of 3D strain tensors without imaging multiple orientations and without numerical interpolation. The performance and accuracy of the method is demonstrated in vitro on a phantom and in vivo in four healthy adult human subjects.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A new paint testing device was built to determine the resistance of paints to darkening due to road grime being tracked onto them. The device consists of a tire rotating on a sample drum. Soil was applied to the tire and then tracked onto paint samples which were attached to the drum. A colorimeter was used to measure the lightness of the paints after being tracked. Lightness is measured from 0 (absolute black) to 100 (absolute white). Four experiments were run to determine the optimum time length to track a sample, the reproducibility, the effects of different soils, and the maximum acceptable level for darkening of a paint. The following conclusions were reached: 1) the optimum tracking time was 10 minutes; 2) the reproducibility had a standard deviation of 1.5 lightness units; 3) different soils did not have a large effect on the amount of darkening on the paints; 4) a maximum acceptable darkness could not be established based on the limited amount of data; and 5) a correlation exists between the paints which were darkening in the field and the paints which were turning the darkest on the tracking wheel.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction: The development of novel therapies and the increasing number of trials testing management strategies for luminal Crohn's disease (CD) have not filled all the gaps in our knowledge. Thus, in clinical practice, many decisions for CD patients need to be taken without high quality evidence. For this reason, a multidisciplinary European expert panel followed the RAND method to develop explicit criteria for the management of individual patients with active, steroid-dependent (ST-D) and steroid-refractory (ST-R) CD. Methods: Twelve international experts convened in Geneva, Switzerland in December 2007, to rate explicit clinical scenarios, corresponding to real daily practice, on a 9-point scale according to the literature evidence and their own expertise. Median ratings were stratified into three categories: appropriate (7-9), uncertain (4-6) and inappropriate (1-3). Results: Overall, panelists rated 296 indications pertaining to mild-to-moderate, severe, ST-D, and ST-R CD. In anti-TNF naïve patients, budesonide and prednisone were found appropriate for mildmoderate CD, and infliximab (IFX) when those had previously failed or had not been tolerated. In patients with prior success with IFX, this drug with or without co-administration of a thiopurine analog was favored. Other anti-TNFs were appropriate in case of intolerance or resistance to IFX. High doses steroids, IFX or adalimumab were appropriate in severe active CD. Among 105 indications for ST-D or ST-R disease, the panel considered appropriate the thiopurine analogs, methotrexate, IFX, adalimumab and surgery for limited resection, depending on the outcome of prior therapies. Anti-TNFs were generally considered appropriate in ST-R. Conclusion: Steroids, including budesonide for mild-to-moderate CD, remain first-line therapies in active luminal CD. Anti-TNFs, in particular IFX with respect to the amount of available evidence, remain second-line for most indications. Thiopurine analogs are preferred to anti-TNFs when steroids are not appropriate, except when anti-TNFs were previously successful. These recommendations are available online (www.epact.ch). A prospective evaluation of these criteria in a large database in Switzerland in underway to validate these criteria.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The IDPH Public Health Tracking Program is an excellent way to collect data related to various indicators for Iowans, but those looking for national statistics or data from other states may want to check out the Health Indicators Warehouse (healthindicators.gov). Run and maintained by the CDC’s National Center for Health Statistics, this site is a centralized source for national, state, and county data for a wide variety of indicators. The data is available to the public, and can be accessed either through the tables and charts directly on the website, or indicators can be downloaded to use in a spreadsheet. Once on the site, users are able to search for their desired data either by topic or geographic region. Filters can then be applied to the chosen field to narrow down the user’s search and obtain the preferred statistics. In addition, users are also able to search for indicators derived from state and federal health indicator initiatives: County Health Rankings, Community Health Status Indicators, Healthy People 2020, and CMS Community Indicators. The warehouse provides an overview of each indicator after the user has made their selection. This overview includes information on how the data was calculated and what characteristics are being represented. For example, percent of binge drinking adults is prefaced in the overview that data was based on the question: “Considering all types of alcoholic beverages, how many times during the past 30 days did you have [5 for men, 4 for women] or more drinks on an occasion?" Data is viewable either in the basic table format, chart format, or for some indicators it is possible to view it in terms of a national map. The Health Indicators Warehouse updates indicators as data becomes available, but the collection of years varies amongst the indicators. Nonetheless, this site is a useful resource to anyone looking for comparative indicators throughout the nation or is interested in one of the hundreds of indicators housed by the site. For more information or to check out what the warehouse has to offer visit: http://healthindicators.gov/

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The active fragment derived from factor XII (factor XIIf) was purified from human plasma and administered intravenously to normotensive conscious rats. Factor XIIf-mediated hypotension was dose-dependent and augmented by pretreatment with captopril, an inhibitor of the angiotensin I- and bradykinin-processing enzyme. In contrast, factor XIIf-induced hypotension was not enhanced by blockade of the renin-angiotensin system by saralasin, a competitive antagonist of angiotensin II at the vascular receptor level. These results suggest that factor XIIf-mediated hypotension is due to the formation of bradykinin.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: Bone cements and substitutes are commonly used in surgery to deliver antibiotics locally. The objective of this study was to assess the systemic absorption and disposition of vancomycin in patients treated with active calcium sulfate bone filler and to predict systemic concentrations under various conditions. Method: 277 blood samples were taken from 42 patients receiving vancomycin in bone cement during surgery. Blood samples were collected from 3h to 10 days after implantation. Vancomycin was measured by immunoenzymatic assay. Population pharmacokinetic (PK) analysis was performed using NONMEM to assess average estimates and variability of PK parameters. Based on the final model, simulations with various doses and renal function levels were performed. Results: The patients were 64 ± 20 years old, their body weight was 81 ± 22 kg and Cockcroft-Gault creatinine clearance (CLcr) 98 ± 55 mL/min. Vancomycin doses ranged from 200 mg to 6000 mg and implantation sites were hip (n=16), tibia (10) or others (16). Concentration profiles remained low and consistent with absorption rate-limited first-order release, while showing prominent variability. Mean clearance (CL) was 3.87 L/h (CV 35%), absorption rate constant (ka) 0.004 h-1 (66%) and volume of distribution (V) 9.5 L. Simulations with up to 8000 mg vancomycin implant showed systemic concentrations exceeding 20 mg/L for 3.5 days in 43% of the patients with CLcr 15 mL/min, whereas 7% of the patients with normal renal function had a concentration above 20 mg/L for 1.1 days. Subtherapeutic concentrations (0.4-4 mg/L) were predicted during a median of 22 days in patients with normal renal function and 4000 mg vancomycin implant, with limited influence of dose or renal function. Conclusion: Vancomycin-laden calcium sulfate implant does not raise toxicity concern. Selection of resistant bacteria, such as Enterococcus and Staphylococcus species, might however be a concern, as simulations show persistent subtherapeutic systemic concentrations during 3 to 4 weeks in these patients.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Paclitaxel (Tx)-loaded anti-HER2 immunonanoparticles (NPs-Tx-HER) were prepared by the covalent coupling of humanized monoclonal anti-HER2 antibodies (trastuzumab, Herceptin) to Tx-loaded poly (dl-lactic acid) nanoparticles (NPs-Tx) for the active targeting of tumor cells that overexpress HER2 receptors. The physico-chemical properties of NPs-Tx-HER were compared to unloaded immunonanoparticles (NPs-HER) to assess the influence of the drug on anti-HER2 coupling to the NP surface. The immunoreactivity of sulfo-MBS activated anti-HER2 mAbs and the in vitro efficacy of NPs-Tx-HER were tested on SKOV-3 ovarian cancer cells that overexpress HER2 antigens. Tx-loaded nanoparticles (NPs-Tx) obtained by a salting-out method had a size of 171+/-22 nm (P.I.=0.1) and an encapsulation efficiency of about of 78+/-10%, which corresponded to a drug loading of 7.8+/-0.8% (w/w). NPs-Tx were then thiolated and conjugated to activated anti-HER2 mAbs to obtain immunonanoparticles of 237+/-43 nm (P.I.=0.2). The influence of the activation step on the immunoreactivity of the mAbs was tested on SKOV-3 cells using 125I-radiolabeled mAbs, and the activity of the anti-HER2 mAbs was minimally affected after sulfo-MBS functionalization. Approximately 270 molecules of anti-HER2 mAbs were bound per nanoparticle. NPs-Tx-HER exhibited a zeta potential of 0.2+/-0.1 mV. The physico-chemical properties of the Tx-loaded immunonanoparticles were very similar to unloaded immunonanoparticles, suggesting that the encapsulation of the drug did not influence the coupling of the mAbs to the NPs. No drug loss was observed during the preparation process. DSC analysis showed that encapsulated Tx is in an amorphous or disordered-crystalline phase. These results suggest that Tx is entrapped in the polymeric matrix and not adsorbed to the surface of the NPs. In vitro studies on SKOV-3 ovarian cancer cells demonstrated the greater cytotoxic effect of NPs-Tx-HER compared to other Tx formulations. The results showed that at 1 ng Tx/ml, the viability of cells incubated with drug encapsulated in NP-Tx-HER was lower (77.32+/-5.48%) than the viability of cells incubated in NPs-Tx (97.4+/-12%), immunonanoparticles coated with Mabthera, as irrelevant mAb (NPs-Tx-RIT) (93.8+/-12%) or free drug (92.3+/-9.3%).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: Colonoscopy is reported to be a safe procedure that is routinely performed for the diagnosis and treatment of colorectal diseases. Splenic rupture is considered to be a rare complication with high mortality and morbidity that requires immediate diagnosis and management. Nonoperative management (NOM), surgical treatment (ST), and, more recently, proximal splenic artery embolization (PSAE) have been proposed as treatment options. The goal of this study was to assess whether PSAE is safe even in high-grade ruptures. METHODS: We report two rare cases of post colonoscopy splenic rupture. A systematic review of the literature from 2002 to 2010 (first reported case of PSAE) was performed and the three types of treatment compared. RESULTS: All patients reviewed (77 of 77) presented with intraperitoneal hemorrhage due to isolated splenic trauma. Splenic rupture was high-grade in most patients when grading was possible. Six of 77 patients (7.8 %) were treated with PSAE, including the 2 cases reported herein. Fifty-seven patients (74 %) underwent ST. NOM was attempted first in 25 patients with a high failure rate (11 of 25 [44 %]) and requiring a salvage procedure, such as PSAE or ST. Previous surgery (31 of 59 patients), adhesions (10 of 13), diagnostic colonoscopies (49 of 71), previous biopsies or polypectomies (31 of 57) and female sex (56 of 77) were identified as risk factors. In contrast, splenomegaly (0 of 77 patients), medications that increase the risk of bleeding (13 of 30) and difficult colonoscopies (16 of 51) were not identified as risk factors. PSAE was safe and effective even in elderly patients with comorbidities and those taking medications that increase the risk of bleeding, and the length of the hospital stay was similar to that after ST. CONCLUSION: We propose a treatment algorithm based on clinical and radiological criteria. Because of the high failure rate after NOM, PSAE should be the treatment of choice to manage grade I through IV splenic ruptures after colonoscopy in hemodynamically stabilized patients.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

L'idée d'écrire cet article naît suite à l'arrivée aux urgences du Centre Hospitalier Universitaire Vaudois de deux cas cliniques de rupture de rate après colonoscopie. Ces deux patients se sont présentés à quelques semaines d'intervalle et illustrent une complication peu rapportée des colonoscopies mais décrite dans la littérature scientifique. Nos deux patients ont été traités avec succès par embolisation artérielle proximale. Nous présentons donc 2 cas de rupture de rate après colonoscopie. Nous comparons nos données avec celles obtenues par analyse après revue pertinente de la littérature. Nous avons mis en évidence les facteurs de risque inhérents aux patients et à la procédure. Les différentes prises en charges ont été analysées et les points principaux mis en évidence dans un tableau. Pour finir, nous proposons un diagramme de prise en charge des ruptures de rate de bas grade après colonoscopie par embolisation artérielle proximale.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Listeria monocytogenes was inoculated on the surface of sliced fermented sausages with no added sodium salt. The pathogen was progressively inactivated during the product shelf life (90 days). Antimicrobial packaging of fermented sausages with PVOH films containing nisin induced a more pronounced reduction of L. monocytogenes counts during refrigerated storage. HPP alone (600 MPa, 5 min, 12 °C) had no antimicrobial effect against L. monocytogenes at the studied conditions. Combination of HPP with antimicrobial packaging did not produce any extra protection against L. monocytogenes compared to antimicrobial packaging alone. The lack of effect of HPP on L. monocytogenes was attributed to a protective effect exerted by the low water activity of the product and its lactate content. These results reflect that antimicrobial packaging with the inclusion of nisin as a natural antimicrobial could be considered as an effective method to reduce the levels of L. monocytogenes in sliced fermented sausages with no added sodium salt