939 resultados para weld toe notch
Resumo:
This work is an example of the improvement on quantitative fractography by means of digital image processing and light microscopy. Two techniques are presented to investigate the quantitative fracture behavior of Ti-4Al-4V heat-treated alloy specimens, under Charpy impact testing. The first technique is the Minkowski method for fractal dimension measurement from surface profiles, revealing the multifractal character of Ti-4Al-4V fracture. It was not observed a clear positive correlation of fractal values against Charpy energies for Ti-4Al-4V alloy specimens, due to their ductility, microstructural heterogeneities and the dynamic loading characteristics at region near the V-notch. The second technique provides an entire elevation map of fracture surface by extracting in-focus regions for each picture from a stack of images acquired at successive focus positions, then computing the surface roughness. Extended-focus reconstruction has been used to explain the behavior along fracture surface. Since these techniques are based on light microscopy, their inherent low cost is very interesting for failure investigations.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
The aim of this study was to analyze the effect of successive TIG (tungsten inert gas) welding repairs on the reverse bending fatigue strength of AISI 4130 steel, which is widely used in components critical to the flight-safety. In order to simulate the abrupt maneuvers, wind bursts, motor vibration and helixes efforts, which generate cyclic bending loadings at the welded joints of a specific aircraft component called motor cradle, experimental reverse bending fatigue tests were carried out on specimens made from hot-rolled steel plate, 1.10 mm (0.043 in) thick, by mean of a SCHENK PWS equipment, with load ratio R = -1, under constant amplitude, at 30 Hz frequency and room temperature. It was observed that the bending fatigue strength decreases after the TIG (Tungsten Inert Gas) welding process application on AISI 4130 steel, with subsequent decrease due to re-welding sequence as well. Microstructural analyses and microhardness measurements on the base material, heat-affected zone (HAZ) and weld metal, as well as the effects of the weld bead geometry on the obtained results, have complemented this study.
Resumo:
The conventional radiographic technique using industrial radiographic films is with the days finishing. The Digital Radiography is taking place in several sectors, e.g., the medical, aerospace, security, automotive, etc. In addition to representing a technological trend, it has been demonstrated that digital radiography offers a series of benefits in terms of productivity, sensitivity, environmental aspects, image treatment tools, cost reduction, etc. If one weld seam to be inspected is from a serried product, as example a pipe, the best option to be implemented is the Flat Panel Detector with this equipment is possible to reduce the obtaining digital radiographic images in place of films and reducing the inspection cycle time due to its high degree of automation. In the experiments described in this paper this new technique was tested and the results were compared with those obtained by the conventional radiography. The welded specimens were prepared using the submerged-arc welding process and small artificial cracks of the most varied dimensions, present in the specimens, were used to establish a comparison of the sensitivities presented by the techniques employed After conducting several experiments, the digital method presented the highest sensitivity to the wire-type Image Quality Indicator (IQI) and in the detection of small defects, leading to the conclusion that the use of digital radiography using the flat-panel detector offers advantages over the conventional technique [1, 2]. This work was carried out based on the API 5L Edition 2004 [3] and ISO 3183 Edition 2007 [4] specifications.
Resumo:
Digital radiography in the inspection of welded pipes to be installed under deep water offshore gas and oil pipelines, like a presalt in Brazil, in the paper has been investigated. The aim is to use digital radiography for nondestructive testing of welds as it is already in use in the medical, aerospace, security, automotive, and petrochemical sectors. Among the current options, the DDA (Digital Detector Array) is considered as one of the best solutions to replace industrial films, as well as to increase the sensitivity to reduce the inspection cycle time. This paper shows the results of this new technique, comparing it to radiography with industrial films systems. In this paper, 20 test specimens of longitudinal welded pipe joints, specially prepared with artificial defects like cracks, lack of fusion, lack of penetration, and porosities and slag inclusions with varying dimensions and in 06 different base metal wall thicknesses, were tested and a comparison of the techniques was made. These experiments verified the purposed rules for parameter definitions and selections to control the required digital radiographic image quality as described in the draft international standard ISO/DIS 10893-7. This draft is first standard establishing the parameters for digital radiography on weld seam of welded steel pipes for pressure purposes to be used on gas and oil pipelines.
Resumo:
Structures critical to the flight-safety are commonly submitted to several maintenance repairs at the welded joints in order to prolong the in-service life of aircrafts. The aim of this study is to analyze the effects of Tungsten Inert Gas (TIG) welding repair on the structural integrity of the AISI 4130 aeronautical steel by means of experimental fatigue crack growth tests in base-material, heat-affected zone (HAZ) and weld metal. The tests were performed on hot-rolled steel plate specimens, 0.89 mm thick, with load ratio R = 0.1, constant amplitude, at 10 Hz frequency and room temperature. Increase of the fracture resistance was observed in the weld metal but decreasing in the HAZ after repair. The results were associated to microhardness and microstructural changes with the welding sequence. (C) 2010 Published by Elsevier Ltd.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
In this study a pulsed Nd:YAG laser was used to join Monel 400 thin foil with 100 mu m thickness. Pulse energy was varied from 1.0 to 2.25J at small increments of 0.25J. The macro and microstructures were analyzed by optical microscopy, tensile shear test and microhardness. Sound laser welds without discontinuities were obtained with 1.5 J pulse energy. Results indicate that using a precise control of the pulse energy, and so a control of the bottom foil dilution rate, it is possible to weld Monel 400 thin foil. The process appeared to be very sensitive to the gap between couples.
Resumo:
In this study a pulsed Nd:YAG laser was used to join Hastelloy C-276 thin foil with 100 microns thickness. Pulse energy was varied from 1.0 to 2.25 J at small increments of 0.25 J with a 4 ms pulse duration. The macro and microstructures of the welds were analyzed by optical and electronic microscopy, tensile shear test and microhardness. Sound laser welds without discontinuities were obtained with 1.5 J pulse energy. Results indicate that using a precise control of the pulse energy, and so a control of the dilution rate, it is possible to weld Hastelloy C-276 thin foil by pulsed Nd: YAG laser. (C) 2012 Published by Elsevier B. V. Selection and/or review under responsibility of Bayerisches Laserzentrum GmbH
Resumo:
Descreve-se caso clínico de paciente do sexo masculino, jovem, imunocompetente, portador de melanoníquia fúngica no terceiro pododáctilo causado por Scytalidium dimidiatum. Discutem-se a semiotécnica diagnóstica, seus diferenciais e a terapêutica adequada. Os autores destacam que a etiologia fúngica deva ser considerada no diagnóstico das melanoníquias.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Spermiogenesis in Plagioscion squamosissimus occurs in cysts. It involves a gradual differentiation process of spermatids that is characterized mainly by chromatin compaction in the nucleus and formation of the flagellum, resulting in the spermatozoa, the smallest germ cells. At the end of spermiogenesis, the cysts open and release the newly formed spermatozoa into the lumen of the seminiferous tubules, the spermatozoa do not have an acrosome and are divided into head, midpiece, and tail or flagellum, the spermatozoa of P. squamosissimus are of perciform type with the flagellum parallel to the nucleus and the centrioles located outside the nuclear notch. (C) 1999 Harcourt Publishers Ltd.
Resumo:
CONTEXTO: Os efeitos da levodopa na marcha de pacientes com Doença de Parkinson (DP) em terrenos desobstruídos são conhecidos, mas pouco se conhece sobre seus efeitos na marcha com obstáculos. OBJETIVO: Este estudo objetivou descrever, por meio de ferramenta cinemática, o comportamento locomotor de pacientes com DP e verificar as estratégias locomotoras, sem e sob o efeito da levodopa, durante a ultrapassagem de obstáculos de diferentes alturas. MÉTODO: Cinco pacientes com DP (Hoehn e Yahr= 2±0; idade= 68,4±5,7 anos) percorreram, andando, 10m e ultrapassaram um de dois obstáculos (alto= metade da altura do joelho e baixo= altura do tornozelo) posicionado no meio da passarela em duas sessões (em jejum e no pico de ação do medicamento). As seguintes variáveis foram coletadas e analisadas: distância horizontal pé-obstáculo (DHPO), distância vertical pé-obstáculo (DVPO); distância horizontal obstáculo-pé (DHOP) e velocidades médias, horizontais e verticais, nas fases de abordagem e aterrissagem (respectivamente, VHAO,VVAO; VHDO,VVDO). RESULTADOS: A ANOVA, por tentativa, revelou efeito principal de obstáculo para DVPO (F1,49=15,33; p< 0,001), para VVAO (F1,49= 82,184; p< 0,001), para VHDO (F1,49= 15,33; p< 0,001) e para VVDO (F1,49= 31,30; p< 0,001); e efeito principal de medicamento para DVPO (F1,49= 6,66; p< 0,013) e para VVAO (F1,49= 10,174; p< 0,002). CONCLUSÕES: Pacientes foram mais perturbados pelo obstáculo alto. Os sintomas da DP (bradicinesia e hipocinesia) foram diminuídos com o medicamento, evidenciando aumento geral da velocidade da perna de abordagem e da margem de segurança sobre os obstáculos. Pacientes com DP, independente da condição de medicamento, apresentaram um comportamento que garantiu segurança e estabilidade na marcha.
Resumo:
INTRODUÇÃO: Comprometimentos na marcha de pacientes com paralisia supranuclear progressiva (PSP) podem aumentar o risco de quedas durante o andar, especialmente em ambientes complexos. OBJETIVO: Descrever o comportamento locomotor de uma paciente com PSP, nas condições de marcha livre e marcha adaptativa. MATERIAIS E MÉTODOS: Estudo de caso de uma paciente com PSP (71 anos). Para análise cinemática, nas condições de marcha livre, com obstáculo baixo e alto, uma câmera digital registrou uma passada completa da paciente. RESULTADOS: Com o aumento da complexidade do ambiente (marcha livre, obstáculo baixo e alto, respectivamente), foi observada diminuição do comprimento do passo (0,37 ± 0,07; 0,30 ± 0,07; 0,26 ± 0,06 m), do comprimento da passada (0,71 ± 0,11; 0,58 ± 0,15; 0,47 ± 0,07 m) e da velocidade da passada (0,55 ± 0,14; 0,43 ± 0,11; 0,36 ± 0,11 m/s). Aumento progressivo ocorreu na duração do duplo suporte da passada livre (29,47%) para a passada antes do obstáculo alto (41,11%). Observou-se, ainda, ligeira diminuição na distância vertical pé/obstáculo alto (membro/abordagem: 7,18 ± 1,88; e membro/suporte: 8,84 ± 2,57 cm) em relação ao obstáculo baixo (membro de abordagem: 8,86 ± 1,88; e membro de suporte: 11,67 ± 2,09 cm). CONCLUSÃO: A PSP afetou de forma evidente a marcha da paciente. Inflexibilidade para a adaptação da marcha às demandas do ambiente foi observada durante a aproximação e a transposição dos obstáculos, o que pode aumentar o risco de tropeços e quedas.