951 resultados para water drinking test


Relevância:

30.00% 30.00%

Publicador:

Resumo:

This project was performed at Rochester Institute of Technology to get more understanding and knowledge about AM and FM screenings similarities and differences with considerations of the mottle. By designing a test form conformed to the specific measurements and printing it on Heidelberg's Sunday 2000 press, the project group has evaluated the questions that already existed and the ones that occurred during the project. Hence the first press run left some unexpected phenomenon therefore another press run was performed. Measurements were performed and graphs produced in Excel. The project group evaluated the results and from that able to establish facts and draw conclusions. It has been a great experience for the project group and they have learnt a lot.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Dynamic system test methods for heating systems were developed and applied by the institutes SERC and SP from Sweden, INES from France and SPF from Switzerland already before the MacSheep project started. These test methods followed the same principle: a complete heating system – including heat generators, storage, control etc., is installed on the test rig; the test rig software and hardware simulates and emulates the heat load for space heating and domestic hot water of a single family house, while the unit under test has to act autonomously to cover the heat demand during a representative test cycle. Within the work package 2 of the MacSheep project these similar – but different – test methods were harmonized and improved. The work undertaken includes:  • Harmonization of the physical boundaries of the unit under test. • Harmonization of the boundary conditions of climate and load. • Definition of an approach to reach identical space heat load in combination with an autonomous control of the space heat distribution by the unit under test. • Derivation and validation of new six day and a twelve day test profiles for direct extrapolation of test results.   The new harmonized test method combines the advantages of the different methods that existed before the MacSheep project. The new method is a benchmark test, which means that the load for space heating and domestic hot water preparation will be identical for all tested systems, and that the result is representative for the performance of the system over a whole year. Thus, no modelling and simulation of the tested system is needed in order to obtain the benchmark results for a yearly cycle. The method is thus also applicable to products for which simulation models are not available yet. Some of the advantages of the new whole system test method and performance rating compared to the testing and energy rating of single components are:  • Interaction between the different components of a heating system, e.g. storage, solar collector circuit, heat pump, control, etc. are included and evaluated in this test. • Dynamic effects are included and influence the result just as they influence the annual performance in the field. • Heat losses are influencing the results in a more realistic way, since they are evaluated under "real installed" and representative part-load conditions rather than under single component steady state conditions.   The described method is also suited for the development process of new systems, where it replaces time-consuming and costly field testing with the advantage of a higher accuracy of the measured data (compared to the typically used measurement equipment in field tests) and identical, thus comparable boundary conditions. Thus, the method can be used for system optimization in the test bench under realistic operative conditions, i.e. under relevant operating environment in the lab.   This report describes the physical boundaries of the tested systems, as well as the test procedures and the requirements for both the unit under test and the test facility. The new six day and twelve day test profiles are also described as are the validation results.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Previous to 1970, state and federal agencies held exclusive enforcement responsibilities over the violation of pollution control standards. However, recognizing that the government had neither the time nor resources to provide full enforcement, Congress created citizen suits. Citizen suits, first amended to the Clean Air Act in 1970, authorize citizens to act as private attorney generals and to sue polluters for violating the terms of their operating permits. Since that time, Congress has included citizen suits in 13 other federal statutes. The citizen suit phenomenon is sufficiently new that little is known about it. However, we do know that citizen suits have increased rapidly since the early 1980's. Between 1982 and 1986 the number of citizen suits jumped from 41 to 266. Obviously, they are becoming a widely used method of enforcing the environmental statutes. This paper will provide a detailed description, analysis and evaluation of citizen suits. It will begin with an introduction and will then move on to provide some historic and descriptive background on such issues as how citizen suit powers are delegated, what limitations are placed on the citizens, what parties are on each side of the suit, what citizens can enforce against, and the types of remedies available. The following section of the paper will provide an economic analysis of citizen suits. It will begin with a discussion of non-profit organizations, especially non-profit environmental organizations, detailing the economic factors which instigate their creation and activities. Three models will be developed to investigate the evolution and effects of citizen suits. The first model will provide an analysis of the demand for citizen suits from the point of view of a potential litigator showing how varying remedies, limitations and reimbursement procedures can effect both the level and types of activities undertaken. The second model shows how firm behavior could be expected to respond to citizen suits. Finally, a third model will look specifically at the issue of efficiency to determine whether the introduction of citizen enforcement leads to greater or lesser economic efficiency in pollution control. The database on which the analysis rests consists of 1205 cases compiled by the author. For the purposes of this project this list of citizen suit cases and their attributes were computerized and used to test a series of hypotheses derived from three original economic models. The database includes information regarding plaintiffs, defendants date notice and/or complaint was filed and statutes involved in the claim. The analysis focuses on six federal environmental statutes (Clean Water Act} Resource Conservation and Recovery Act, Comprehensive Environmental Response Compensation and Liability Act, Clean Air Act, Toxic Substances Control Act, and Safe Drinking Water Act) because the majority of citizen suits have occurred under these statutes.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Drinking water distribution networks risk exposure to malicious or accidental contamination. Several levels of responses are conceivable. One of them consists to install a sensor network to monitor the system on real time. Once a contamination has been detected, this is also important to take appropriate counter-measures. In the SMaRT-OnlineWDN project, this relies on modeling to predict both hydraulics and water quality. An online model use makes identification of the contaminant source and simulation of the contaminated area possible. The objective of this paper is to present SMaRT-OnlineWDN experience and research results for hydraulic state estimation with sampling frequency of few minutes. A least squares problem with bound constraints is formulated to adjust demand class coefficient to best fit the observed values at a given time. The criterion is a Huber function to limit the influence of outliers. A Tikhonov regularization is introduced for consideration of prior information on the parameter vector. Then the Levenberg-Marquardt algorithm is applied that use derivative information for limiting the number of iterations. Confidence intervals for the state prediction are also given. The results are presented and discussed on real networks in France and Germany.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

New business and technology platforms are required to sustainably manage urban water resources [1,2]. However, any proposed solutions must be cognisant of security, privacy and other factors that may inhibit adoption and hence impact. The FP7 WISDOM project (funded by the European Commission - GA 619795) aims to achieve a step change in water and energy savings via the integration of innovative Information and Communication Technologies (ICT) frameworks to optimize water distribution networks and to enable change in consumer behavior through innovative demand management and adaptive pricing schemes [1,2,3]. The WISDOM concept centres on the integration of water distribution, sensor monitoring and communication systems coupled with semantic modelling (using ontologies, potentially connected to BIM, to serve as intelligent linkages throughout the entire framework) and control capabilities to provide for near real-time management of urban water resources. Fundamental to this framework are the needs and operational requirements of users and stakeholders at domestic, corporate and city levels and this requires the interoperability of a number of demand and operational models, fed with data from diverse sources such as sensor networks and crowsourced information. This has implications regarding the provenance and trustworthiness of such data and how it can be used in not only the understanding of system and user behaviours, but more importantly in the real-time control of such systems. Adaptive and intelligent analytics will be used to produce decision support systems that will drive the ability to increase the variability of both supply and consumption [3]. This in turn paves the way for adaptive pricing incentives and a greater understanding of the water-energy nexus. This integration is complex and uncertain yet being typical of a cyber-physical system, and its relevance transcends the water resource management domain. The WISDOM framework will be modeled and simulated with initial testing at an experimental facility in France (AQUASIM – a full-scale test-bed facility to study sustainable water management), then deployed and evaluated in in two pilots in Cardiff (UK) and La Spezia (Italy). These demonstrators will evaluate the integrated concept providing insight for wider adoption.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The effects of serum and brain calcium concentration on rat behavior were tested by maintaining animals on either distilled water (N = 60) or water containing 1% calcium gluconate (N = 60) for 3 days. Animals that were maintained on high calcium drinking water presented increased serum calcium levels (control = 10.12 ± 0.46 vs calcium treated = 11.62 ± 0.51 µg/dl). Increase of brain calcium levels was not statistically significant. In the behavioral experiments each rat was used for only one test. Rats that were maintained on high calcium drinking water showed increased open-field behavior of ambulation (20.68%) and rearing (64.57%). on the hole-board, calcium-supplemented animals showed increased head-dip (67%) and head-dipping (126%), suggesting increased ambulatory and exploratory behavior. The time of social interaction was normal in animals maintained on drinking water containing added calcium. Rats supplemented with calcium and submitted to elevated plus-maze tests showed a normal status of anxiety and elevated locomotor activity. We conclude that elevated levels of calcium enhance motor and exploratory behavior of rats without inducing other behavioral alterations. These data suggest the need for a more detailed analysis of several current proposals for the use of calcium therapy in humans, for example in altered blood pressure states, bone mineral metabolism disorders in the elderly, hypocalcemic states, and athletic activities.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A quantificação da evaporação do solo é requerida em estudos de balanço hídrico de culturas e em aplicações que visam a aumentar a eficiência do uso da água pelos cultivos. O objetivo deste trabalho foi testar um modelo de microlisímetro (ML) para medir a evaporação do solo em condições irrigada e não irrigada. Os MLs foram construídos utilizando tubos de PVC rígido, medindo 100 mm de diâmetro interno, 150 mm de profundidade e 2,5 mm de espessura da parede. Quatro MLs foram assentados sobre a superfície de dois lisímetros de pesagem de alta precisão conduzidos com solo nu, previamente instalados no Iapar, em Londrina-PR. Os lisímetros tinham dimensões de 1,4 m de largura, 1,9 m de comprimento e 1,3 m de profundidade, e estavam sendo conduzidos com e sem irrigação. A evaporação medida nos MLs (E ML) foi comparada com a medida nos lisímetros (E L), durante quatro períodos do ano. As diferenças entre E ML e E L foram mínimas para condições de baixa e elevada demanda atmosférica, e também para condições de solo irrigado ou não irrigado, indicado que o modelo de ML testado neste trabalho é adequado para medir a evaporação do solo.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The accelerated ageing (AA) test is widely used to evaluate seed vigor in various species including vegetable crops. The objective of this work was to study procedures for conducting AA to evaluate seed vigor of pumpkin and zucchini seed lots. Five seed lots of commercially acceptable quality (germination) standards were selected from both cv. `Menina Brasileira' (zucchini) and `Barbara' Hybrid (pumpkin). The following tests were conducted: standard germination, the first count of germination, and AA with and without saline solution (periods of 48, 72 and 96 hours). For each combination of temperature and ageing period, seeds were placed in a single layer on a screen in a germination plastic box with either 40 mL deionized water or 40g NaCl/100mL of water. Both AA methods identified lots 2 and 5 of `Menina Brasileira' and lot 10 of `Barbara' hybrid as having the lowest physiological quality. The temperature 41 C promoted a more drastic reduction in germination than did 38 C. This observation was more marked after 96 hours. Based on the results obtained, it can be concluded that the combination 41 degrees C/96 hours should be used to evaluate the physiological potential of pumpkin and zucchini seeds; however, additional studies are necessary to evaluate other combinations and confirm this indication.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The electrical conductivity test is still an excellent tool to evaluate the effect of seeds of various forest and agricultural species and recent studies have been conducted aiming at verifying its application in forest seeds. The objective of this study was to establish a specific methodology to test the electrical conductivity of forest seeds of Zeyheria tuberculosis. Four lots of seeds were used, which were submitted to the germination test, evaluating the percentage of germination, germination speed index and dry mass of seedlings. For the electrical conductivity test, five replicates of 20 seeds installed in three volumes of deionized water (75, 100 and 125 mL) were used and eight periods for seed imbibitions (2, 4, 6, 12, 18, 24, 48 and 72 hour) at 25 degrees C were allowed. The statistical design used was completely random; the comparison of means was performed by Tukey test at 5 % probability. Lot II showed higher germination percentage and speed. The electrical conductivity test allows discrimination of the same batch by the germination test under laboratory conditions. It was possible to separate the seed lot presenting better physiological quality (lot II) from among the other lots. It was recommended the use of 75 or 125 mL of deionized water at a temperature of 25 degrees C to perform the electrical conductivity test.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Um experimento foi realizado visando avaliar o fornecimento de rações úmidas e de água de consumo e rações com edulcorante para leitões desmamados e seus efeitos sobre o desempenho até o 90kg de peso vivo. Foram utilizados 32 leitões Large White x Landrace, desmamados aos 21 dias, submetidos, durante a fase inicial I (21 a 42 dias de idade), a 8 tratamentos correspondentes à combinação dos fatores: forma de apresentação da ração (seca e úmida), tipo de ração (sem e com edulcorante) e água de consumo (sem e com edulcorante). Foram avaliados a ocorrência de diarréia até o 10º dia pós-desmame, o ganho diário de peso (GDP), o consumo diário de ração (CDR) e a conversão alimentar (CA) até os 90kg de peso vivo. O consumo diário de água (CDA) foi avaliado na fase inicial I. O delineamento foi em blocos ao acaso, com arranjo fatorial 2³, com quatro repetições, sendo as médias comparadas pelo teste de Tukey e a incidência de diarréia pelo teste de qui-quadrado. Foram observadas diferenças (P<0,05), na fase inicial I, para o CDA para os grupos tratados com ração seca e para o CDR para os animais que receberam água com edulcorante. A ocorrência de diarréia foi maior (P<0,05) para os animais tratados com ração seca. O desempenho até os 90 kg de peso vivo foi semelhante entre os fatores (P>0,05). O experimento demonstrou que os tratamentos dirigidos na fase pós-desmame são insuficientes para melhorar os resultados até os 90kg de peso vivo.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Eutrophication is a growing process present in the water sources located in the northeast of Brazil. Among the main consequences of these changes in trophic levels of a water source, stands out adding complexity to the treatment to achieve water standards. By these considerations, this study aimed to define, on a laboratory scale, products and operational conditions to be applied in the processing steps using raw water from Gargalheiras dam, RN, Brazil. The dam mentioned shows a high number of cyanobacteria, with a concentration of cells / ml higher than that established by Decree No. 518/04 MS. The same source was also considered by the state environmental agency in 2009 as hypereutrophic. The static tests developed in this research simulated direct filtration (laboratory filters) and pre-oxidation with chlorine and powdered activated carbon adsorption. The research included the evaluation of the coagulants aluminum hydrochloride (HCA) and alum (SA). The development of the research investigated the conditions for rapid mixing, the dosages of coagulants and pHs of coagulation by the drawing of diagrams. The interference of filtration rate and particle size of filtering means were evaluated as samples and the time of contact were tested with chlorine and activated carbon. By the results of the characterization of the raw water source it was possible to identify the presence of a high pH (7.34). The true color was significant (29 uH) in relation to the apparent color and turbidity (66 uH and 13.60 NTU), reflecting in the measurement of organic matter: MON (8.41 mg.L-1) and Abs254 (0.065 cm-1). The optimization of quick mix set time of 17", the speed gradient of 700 s-1 in the coagulation with HCA and the time of 20" with speed gradient of 800 s-1 for SA. The smaller particle sizes of sand filtering means helped the treatment and the variation in filtration rate did not affect significantly the efficiency of the process. The evaluation of the processing steps found adjustment in standard color and turbidity of the Decree nº 518/04 MS, taking in consideration the average values found in raw water. In the treatment using the HCA for direct filtration the palatable pattern based on the apparent color can be achieved with a dose of 25 mg L-1. With the addition of pre-oxidation step, the standard result was achieved with a reduced dose for 12 mgHCA.L-1. The turbidity standard for water was obtained by direct filtration when the dose exceeds 25 mg L-1 of HCA. With pre-oxidation step there is the possibility of reducing the dose to 20 mg L-1.The addition of CAP adsorption, promoted drinking water for both parameters, with even lower dosage, 13 mg L-1 of HCA. With coagulation using SA removal required for the parameter of apparent color it was achieved with pre-oxidation and 22 mgSA.L-1. Despite the satisfactory results of treatment with the alum, it was not possible to provide water with turbidity less than 1.00 NTU even with the use of all stages of treatment

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)