927 resultados para voltage measurement


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Due to the intense international competition, demanding, and sophisticated customers, and diverse transforming technological change, organizations need to renew their products and services by allocating resources on research and development (R&D). Managing R&D is complex, but vital for many organizations to survive in the dynamic, turbulent environment. Thus, the increased interest among decision-makers towards finding the right performance measures for R&D is understandable. The measures or evaluation methods of R&D performance can be utilized for multiple purposes; for strategic control, for justifying the existence of R&D, for providing information and improving activities, as well as for the purposes of motivating and benchmarking. The earlier research in the field of R&D performance analysis has generally focused on either the activities and considerable factors and dimensions - e.g. strategic perspectives, purposes of measurement, levels of analysis, types of R&D or phases of R&D process - prior to the selection of R&Dperformance measures, or on proposed principles or actual implementation of theselection or design processes of R&D performance measures or measurement systems. This study aims at integrating the consideration of essential factors anddimensions of R&D performance analysis to developed selection processes of R&D measures, which have been applied in real-world organizations. The earlier models for corporate performance measurement that can be found in the literature, are to some extent adaptable also to the development of measurement systemsand selecting the measures in R&D activities. However, it is necessary to emphasize the special aspects related to the measurement of R&D performance in a way that make the development of new approaches for especially R&D performance measure selection necessary: First, the special characteristics of R&D - such as the long time lag between the inputs and outcomes, as well as the overall complexity and difficult coordination of activities - influence the R&D performance analysis problems, such as the need for more systematic, objective, balanced and multi-dimensional approaches for R&D measure selection, as well as the incompatibility of R&D measurement systems to other corporate measurement systems and vice versa. Secondly, the above-mentioned characteristics and challenges bring forth the significance of the influencing factors and dimensions that need to be recognized in order to derive the selection criteria for measures and choose the right R&D metrics, which is the most crucial step in the measurement system development process. The main purpose of this study is to support the management and control of the research and development activities of organizations by increasing the understanding of R&D performance analysis, clarifying the main factors related to the selection of R&D measures and by providing novel types of approaches and methods for systematizing the whole strategy- and business-based selection and development process of R&D indicators.The final aim of the research is to support the management in their decision making of R&D with suitable, systematically chosen measures or evaluation methods of R&D performance. Thus, the emphasis in most sub-areas of the present research has been on the promotion of the selection and development process of R&D indicators with the help of the different tools and decision support systems, i.e. the research has normative features through providing guidelines by novel types of approaches. The gathering of data and conducting case studies in metal and electronic industry companies, in the information and communications technology (ICT) sector, and in non-profit organizations helped us to formulate a comprehensive picture of the main challenges of R&D performance analysis in different organizations, which is essential, as recognition of the most importantproblem areas is a very crucial element in the constructive research approach utilized in this study. Multiple practical benefits regarding the defined problemareas could be found in the various constructed approaches presented in this dissertation: 1) the selection of R&D measures became more systematic when compared to the empirical analysis, as it was common that there were no systematic approaches utilized in the studied organizations earlier; 2) the evaluation methods or measures of R&D chosen with the help of the developed approaches can be more directly utilized in the decision-making, because of the thorough consideration of the purpose of measurement, as well as other dimensions of measurement; 3) more balance to the set of R&D measures was desired and gained throughthe holistic approaches to the selection processes; and 4) more objectivity wasgained through organizing the selection processes, as the earlier systems were considered subjective in many organizations. Scientifically, this dissertation aims to make a contribution to the present body of knowledge of R&D performance analysis by facilitating dealing with the versatility and challenges of R&D performance analysis, as well as the factors and dimensions influencing the selection of R&D performance measures, and by integrating these aspects to the developed novel types of approaches, methods and tools in the selection processes of R&D measures, applied in real-world organizations. In the whole research, facilitation of dealing with the versatility and challenges in R&D performance analysis, as well as the factors and dimensions influencing the R&D performance measure selection are strongly integrated with the constructed approaches. Thus, the research meets the above-mentioned purposes and objectives of the dissertation from the scientific as well as from the practical point of view.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study compares different rotor structures of permanent magnet motors with fractional slot windings. The surface mounted magnet and the embedded magnet rotor structures are studied. This thesis analyses the characteristics of a concentrated two-layer winding, each coil of which is wound around one tooth and which has a number of slots per pole and per phase less than one (q < 1). Compared to the integer slot winding, the fractional winding (q < 1) has shorter end windings and this, thereby, makes space as well as manufacturing cost saving possible. Several possible ways of winding a fractional slot machine with slots per pole and per phase lessthan one are examined. The winding factor and the winding harmonic components are calculated. The benefits attainable from a machine with concentrated windingsare considered. Rotor structures with surface magnets, radially embedded magnets and embedded magnets in V-position are discussed. The finite element method isused to solve the main values of the motors. The waveform of the induced electro motive force, the no-load and rated load torque ripple as well as the dynamic behavior of the current driven and voltage driven motor are solved. The results obtained from different finite element analyses are given. A simple analytic method to calculate fractional slot machines is introduced and the values are compared to the values obtained with the finite element analysis. Several different fractional slot machines are first designed by using the simple analytical methodand then computed by using the finite element method. All the motors are of thesame 225-frame size, and have an approximately same amount of magnet material, a same rated torque demand and a 400 - 420 rpm speed. An analysis of the computation results gives new information on the character of fractional slot machines.A fractional slot prototype machine with number 0.4 for the slots per pole and per phase, 45 kW output power and 420 rpm speed is constructed to verify the calculations. The measurement and the finite element method results are found to beequal.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Pulsewidth-modulated (PWM) rectifier technology is increasingly used in industrial applications like variable-speed motor drives, since it offers several desired features such as sinusoidal input currents, controllable power factor, bidirectional power flow and high quality DC output voltage. To achieve these features,however, an effective control system with fast and accurate current and DC voltage responses is required. From various control strategies proposed to meet these control objectives, in most cases the commonly known principle of the synchronous-frame current vector control along with some space-vector PWM scheme have been applied. Recently, however, new control approaches analogous to the well-established direct torque control (DTC) method for electrical machines have also emerged to implement a high-performance PWM rectifier. In this thesis the concepts of classical synchronous-frame current control and DTC-based PWM rectifier control are combined and a new converter-flux-based current control (CFCC) scheme is introduced. To achieve sufficient dynamic performance and to ensure a stable operation, the proposed control system is thoroughly analysed and simple rules for the controller design are suggested. Special attention is paid to the estimationof the converter flux, which is the key element of converter-flux-based control. Discrete-time implementation is also discussed. Line-voltage-sensorless reactive reactive power control methods for the L- and LCL-type line filters are presented. For the L-filter an open-loop control law for the d-axis current referenceis proposed. In the case of the LCL-filter the combined open-loop control and feedback control is proposed. The influence of the erroneous filter parameter estimates on the accuracy of the developed control schemes is also discussed. A newzero vector selection rule for suppressing the zero-sequence current in parallel-connected PWM rectifiers is proposed. With this method a truly standalone and independent control of the converter units is allowed and traditional transformer isolation and synchronised-control-based solutions are avoided. The implementation requires only one additional current sensor. The proposed schemes are evaluated by the simulations and laboratory experiments. A satisfactory performance and good agreement between the theory and practice are demonstrated.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The research of power-line communications has been concentrated on home automation, broadband indoor communications and broadband data transfer in a low voltage distribution network between home andtransformer station. There has not been carried out much research work that is focused on the high frequency characteristics of industrial low voltage distribution networks. The industrial low voltage distribution network may be utilised as a communication channel to data transfer required by the on-line condition monitoring of electric motors. The advantage of using power-line data transfer is that it does not require the installing of new cables. In the first part of this work, the characteristics of industrial low voltage distribution network components and the pilot distribution network are measured and modelled with respect topower-line communications frequencies up to 30 MHz. The distributed inductances, capacitances and attenuation of MCMK type low voltage power cables are measured in the frequency band 100 kHz - 30 MHz and an attenuation formula for the cables is formed based on the measurements. The input impedances of electric motors (15-250 kW) are measured using several signal couplings and measurement based input impedance model for electric motor with a slotted stator is formed. The model is designed for the frequency band 10 kHz - 30 MHz. Next, the effect of DC (direct current) voltage link inverter on power line data transfer is briefly analysed. Finally, a pilot distribution network is formed and signal attenuation in communication channels in the pilot environment is measured. The results are compared with the simulations that are carried out utilising the developed models and measured parameters for cables and motors. In the second part of this work, a narrowband power-line data transfer system is developed for the data transfer ofon-line condition monitoring of electric motors. It is developed using standardintegrated circuits. The system is tested in the pilot environment and the applicability of the system for the data transfer required by the on-line condition monitoring of electric motors is analysed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

IIn electric drives, frequency converters are used to generatefor the electric motor the AC voltage with variable frequency and amplitude. When considering the annual sale of drives in values of money and units sold, the use of low-performance drives appears to be in predominant. These drives have tobe very cost effective to manufacture and use, while they are also expected to fulfill the harmonic distortion standards. One of the objectives has also been to extend the lifetime of the frequency converter. In a traditional frequency converter, a relatively large electrolytic DC-link capacitor is used. Electrolytic capacitors are large, heavy and rather expensive components. In many cases, the lifetime of the electrolytic capacitor is the main factor limiting the lifetime of the frequency converter. To overcome the problem, the electrolytic capacitor is replaced with a metallized polypropylene film capacitor (MPPF). The MPPF has improved properties when compared to the electrolytic capacitor. By replacing the electrolytic capacitor with a film capacitor the energy storage of the DC-linkwill be decreased. Thus, the instantaneous power supplied to the motor correlates with the instantaneous power taken from the network. This yields a continuousDC-link current fed by the diode rectifier bridge. As a consequence, the line current harmonics clearly decrease. Because of the decreased energy storage, the DC-link voltage fluctuates. This sets additional conditions to the controllers of the frequency converter to compensate the fluctuation from the supplied motor phase voltages. In this work three-phase and single-phase frequency converters with small DC-link capacitor are analyzed. The evaluation is obtained with simulations and laboratory measurements.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this work, a LIDAR-based 3D Dynamic Measurement System is presented and evaluated for the geometric characterization of tree crops. Using this measurement system, trees were scanned from two opposing sides to obtain two three-dimensional point clouds. After registration of the point clouds, a simple and easily obtainable parameter is the number of impacts received by the scanned vegetation. The work in this study is based on the hypothesis of the existence of a linear relationship between the number of impacts of the LIDAR sensor laser beam on the vegetation and the tree leaf area. Tests performed under laboratory conditions using an ornamental tree and, subsequently, in a pear tree orchard demonstrate the correct operation of the measurement system presented in this paper. The results from both the laboratory and field tests confirm the initial hypothesis and the 3D Dynamic Measurement System is validated in field operation. This opens the door to new lines of research centred on the geometric characterization of tree crops in the field of agriculture and, more specifically, in precision fruit growing.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Postmortem human chorionic gonadotrophin (HCG) blood assay can confirm postmortem diagnosis of pregnancy or document situations in which HCG levels are elevated. In some cases, however, blood sampling is not possible at autopsy. In this study, HCG was quantified by enzyme-linked fluorescent assay (ELFA) in the bile (n = 5), vitreous humor (n = 4), and postmortem blood (n = 4) of five pregnant women. There were no false negatives in the pregnant subjects (n = 5) or false positives in controls (n = 34), enabling this test to be recommended for routine use in forensic contexts in which the detection of elevated HCG levels could be of interest.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Sap flow could be used as physiological parameter to assist irrigation of screen house citrus nursery trees by continuous water consumption estimation. Herein we report a first set of results indicating the potential use of the heat dissipation method for sap flow measurement in containerized citrus nursery trees. 'Valencia' sweet orange [Citrus sinensis (L.) Osbeck] budded on 'Rangpur' lime (Citrus limonia Osbeck) was evaluated for 30 days during summer. Heat dissipation probes and thermocouple sensors were constructed with low-cost and easily available materials in order to improve accessibility of the method. Sap flow showed high correlation to air temperature inside the screen house. However, errors due to natural thermal gradient and plant tissue injuries affected measurement precision. Transpiration estimated by sap flow measurement was four times higher than gravimetric measurement. Improved micro-probes, adequate method calibration, and non-toxic insulating materials should be further investigated.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Diplomityössä on käsitelty paperin pinnankarkeuden mittausta, joka on keskeisimpiä ongelmia paperimateriaalien tutkimuksessa. Paperiteollisuudessa käytettävät mittausmenetelmät sisältävät monia haittapuolia kuten esimerkiksi epätarkkuus ja yhteensopimattomuus sileiden papereiden mittauksissa, sekä suuret vaatimukset laboratorio-olosuhteille ja menetelmien hitaus. Työssä on tutkittu optiseen sirontaan perustuvia menetelmiä pinnankarkeuden määrittämisessä. Konenäköä ja kuvan-käsittelytekniikoita tutkittiin karkeilla paperipinnoilla. Tutkimuksessa käytetyt algoritmit on tehty Matlab® ohjelmalle. Saadut tulokset osoittavat mahdollisuuden pinnankarkeuden mittaamiseen kuvauksen avulla. Parhaimman tuloksen perinteisen ja kuvausmenetelmän välillä antoi fraktaaliulottuvuuteen perustuva menetelmä.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A network of twenty stakes was set up on Johnsons Glacier in order to determine its dynamics. During the austral summers from 1994-95 to 1997-98, we estimated surface velocities, mass balances and ice thickness variations. Horizontal velocity increased dow nstream from 1 m a- 1 near the ice divides to 40 m a- 1 near the ice terminus. The accumulation zone showed low accumulation rates (maximum of 0,6 m a- 1 (ice)), whereas in the lower part of the glacier, ablation rates were 4,3 m a- 1 (ice). Over the 3-year study period, both in the accumulation and ablation zones, we detected a reduction in the ice surface level ranging from 2 to 10 m from the annual ve rt ical velocities and ice-thinning data, the mass balance was obtained and compared with the mass balance field values, resulting in similar estimates. Flux values were calculated using cross-section data and horizontal velocities, and compared with the results obtained by means of mass balance and ice thinning data using the continuity equation. The two methods gave similar results.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Abstract Purpose: Several well-known managerial accounting performance measurement models rely on causal assumptions. Whilst users of the models express satisfaction and link them with improved organizational performance, academic research, of the realworld applications, shows few reliable statistical associations. This paper provides a discussion on the"problematic" of causality in a performance measurement setting. Design/methodology/approach: This is a conceptual study based on an analysis and synthesis of the literature from managerial accounting, organizational theory, strategic management and social scientific causal modelling. Findings: The analysis indicates that dynamic, complex and uncertain environments may challenge any reliance upon valid causal models. Due to cognitive limitations and judgmental biases, managers may fail to trace correct cause-and-effect understanding of the value creation in their organizations. However, even lacking this validity, causal models can support strategic learning and perform as organizational guides if they are able to mobilize managerial action. Research limitations/implications: Future research should highlight the characteristics necessary for elaboration of convincing and appealing causal models and the social process of their construction. Practical implications: Managers of organizations using causal models should be clear on the purposes of their particular models and their limitations. In particular, difficulties are observed in specifying detailed cause and effect relations and their potential for communicating and directing attention. They should therefore construct their models to suit the particular purpose envisaged. Originality/value: This paper provides an interdisciplinary and holistic view on the issue of causality in managerial accounting models.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Tässä työssä selostetaan kuumalanka-anemometrin käyttö virtausmittauksissa. Kuumalanka-anemometrilla saadaan mitattua virtausnopeuden ja -suunnan lisäksi nopeusheilahteluja. Mittaustaajuus on tyypillisesti useita kymmeniä tuhansia mittauksia sekunnissa ja signaali on jatkuva. Nykytekniikalla pystytään helposti tallentamaan mittauslaitteistolta saatu viesti tietokoneelle ja muuntamaan se nopeudeksi. Hetkellisten nopeuksien avulla voidaan laskea turbulenttisen virtauksen ominaisuuksia, kuten turbulenssin intensiteetti ja spektri. Kuumalanka-anemometrissa lämmitetään sähköisesti ohutta lankaa, joka on mitattavassa virtauksessa. Langan sähköteho on suunnilleen yhtäsuuri kuin langasta konvektiolla siirtyvä lämpöteho. Tällöin on teoreettisesti mahdollista laskea virtausnopeus lämpötehosta lämmönsiirtokorrelaatioilla. Käytännössä laitteisto joudutaan kuitenkin erikseen kalibroimaan, mutta sähkötehon teoreettista riippuvuutta konvektiosta käytetään hyväksi. Kuumalangan lämmitettävä osuus on tyypillisesti halkaisijaltaan 5 µm ja pituudeltaan noin 1 mm. Sitä käytetään pääasiassa kaasuvirtausten mittaamiseen ja valtaosassa mittauksissa virtausaineena on ilma. Kuumalanka voi olla toteutettu kuumakalvotekniikalla, jossa halkaisijaltaan noin 50 - 70 µm paksuinen kuitu on päällystetty ohuella sähköä johtavalla kalvolla. Kuumakalvoanturin ei tarvitse olla muodoltaan sylinterimäinen, se voi olla mm. kartiomainen tai kiilamainen. Erikoispäällystetyllä kuumakalvoanturilla on mahdollista mitata myös nestevirtauksia. Mitattaessa kaasuvirtauksia kuumakalvon etuna on selvästi parempi kestävyys verrattuna kuumalankaan. Nimitystä kuumalanka-anemometri käytetään yleisesti molemmista anturityypeistä Tämän työn alussa käsitellään sylinterin yli tapahtuvaan virtaukseen liittyvää virtausmekaniikkaa ja lämmönsiirtoa. Anemometrin sähköinen osa, laitteisto ja sen kalibrointi käydään läpi. Langan suuntariippuvuuden laskentaan esitetään tarvittavat yhtälöt. Työssä esitellään kolme laitteistolla tehtyä perusmittausta: anturin kohtauskulman muuttaminen, pyörähdyssymmerisen suihkun nopeuskenttä ja tuulitunnelin rajakerros. Lisäksi esitellään yksi käytännöllinen ja vaativampi mittaus, jossa on mitattu nopeusprofiili radiaalikompressorin diffuusorin loppuosassa.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To achieve success in a constantly changing environment and with ever-increasing competition, companies must develop their operations continuously. To do this, they must have a clear vision of what they want to be in the future. This vision can be attained through careful planning and strategising. One method of transforming a strategy and vision into an everyday tool used by employees is the use of a balanced performance measurement system. The importance of performance measurement in the implementation of companies' visions and strategies has grown substantially in the last ten years. Measures are derived from the company's critical success factors and from many different perspectives. There are three time dimensions: past, present and future. Many such performance measurement systems have been created since the 1990s. This is a case study whose main objective is to provide a recommendation for how the case company could make use of performance measurement to support strategic management. To answer this question, the study uses literature-based research and empirical research at the case company's premises. The theoretical part of the study consists of two sections: introducing the Balanced Scorecard and discussing how it supports strategic management and change management. The empirical part of this study determines the company's present performance measurement situation through interviews in the company. The study resulted in a recommendation to the company to start developing the Balanced Scorecard system. By setting up this kind process, the company would be able to change its focus more towards the future, beginning to implement a more process-based organisation and getting its employees to work together towards common goals.