857 resultados para ultrasound assisted dissolution-evaporation
Resumo:
The objective was to design a vascular phantom compatible with digital subtraction angiography, computerized tomography angiography, ultrasound and magnetic resonance angiography (MRA). Fiducial markers were implanted at precise known locations in the phantom to facilitate identification and orientation of plane views from three-dimensional (3-D) reconstructed images. A vascular conduit connected to tubing at the extremities of the phantom ran through an agar-based gel filling it. A vessel wall in latex was included around the conduit to avoid diffusion of contrast agents. Using a lost-material casting technique based on a low melting point metal, geometries of pathological vessels were modeled. During the experimental testing, fiducial markers were detectable in all modalities without distortion. No leak of gadolinium through the vascular wall was observed on MRA after 5 hours. Moreover, no significant deformation of the vascular conduit was noted during the fabrication process (confirmed by microtome slicing along the vessel). The potential use of the phantom for calibration, rescaling, and fusion of 3-D images obtained from the different modalities as well as its use for the evaluation of intra- and inter-modality comparative studies of imaging systems are discussed. In conclusion, the vascular phantom can allow accurate calibration of radiological imaging devices based on x-ray, magnetic resonance and ultrasound and quantitative comparisons of the geometric accuracy of the vessel lumen obtained with each of these methods on a given well defined 3-D geometry.
Resumo:
Dual-energy X-ray absorptiometry (DXA) is commonly used in the care of patients for diagnostic classification of osteoporosis, low bone mass (osteopenia), or normal bone density; assessment of fracture risk; and monitoring changes in bone density over time. The development of other technologies for the evaluation of skeletal health has been associated with uncertainties regarding their applications in clinical practice. Quantitative ultrasound (QUS), a technology for measuring properties of bone at peripheral skeletal sites, is more portable and less expensive than DXA, without the use of ionizing radiation. The proliferation of QUS devices that are technologically diverse, measuring and reporting variable bone parameters in different ways, examining different skeletal sites, and having differing levels of validating data for association with DXA-measured bone density and fracture risk, has created many challenges in applying QUS for use in clinical practice. The International Society for Clinical Densitometry (ISCD) 2007 Position Development Conference (PDC) addressed clinical applications of QUS for fracture risk assessment, diagnosis of osteoporosis, treatment initiation, monitoring of treatment, and quality assurance/quality control. The ISCD Official Positions on QUS resulting from this PDC, the rationale for their establishment, and recommendations for further study are presented here.
Resumo:
Intraoperative ultrasound (IOUS) has been described to be useful during central corpectomy for compressive cervical myelopathy. This study aimed at documenting the utility of IOUS in oblique cervical corpectomy (OCC). Prospective data from 24 patients undergoing OCC for cervical spondylotic myelopathy and ossified posterior longitudinal ligament (OPLL) were collected. Patients had a preoperative cervical spine magnetic resonance (MR) image, IOUS and a postoperative cervical CT scan. Retrospective data from 16 historical controls that underwent OCC without IOUS were analysed to compare the incidence of residual compression between the two groups. IOUS identified the vertebral artery in all cases, detected residual cord compression in six (27%) and missed compression in two cases (9%). In another two cases with OPLL, IOUS was sub-optimal due to shadowing. IOUS measurement of the corpectomy width correlated well with these measurements on the postoperative CT. The extent of cord expansion noted on IOUS after decompression showed no correlation with immediate or 6-month postoperative neurological recovery. No significant difference in residual compression was noted in the retrospective and prospective groups of the study. Craniocaudal spinal cord motion was noted after the completion of the corpectomy. IOUS is an inexpensive and simple real-time imaging modality that may be used during OCC for cervical spondylotic myelopathy. It is helpful in identifying the vertebral artery and determining the trajectory of approach, however, it has limited utility in patients with OPLL due to artifacts from residual ossification.
Resumo:
Assisting people to commit suicide has generated a passionate public debate. In exceptional situations, access to this support can be granted to the demanders in a hospital environment. So did the CHUV and the academic hospitals of Geneva draw up a procedure permitting, in principle, the access to an assistance to commit suicide. Two recent clinical situations experienced in the CHUV's Service of internal medicine have created a lot of discussions, doubts and revealed, sometimes, divergent positions. By the light of this clinical cases, we wished to share the perspective of the internist in charge of the ethician, of the chaplain, of the medical director, of the psychiatrist and of the palliative care responsible. Theses complex situations illustrate the deep ambivalence felt by the clinicians confronted to situations which require a multidisciplinary approach.
Resumo:
OBJECTIVE: To evaluate the correlation between clinical measures of disease activity and a ultrasound (US) scoring system for synovitis applied by many different ultrasonographers in a daily routine care setting within the Swiss registry for RA (SCQM) and further to determine the sensitivity to change of this US Score. METHODS: One hundred and eight Swiss rheumatologists were trained in performing the Swiss Sonography in Arthritis and Rheumatism (SONAR) score. US B-mode and Power Doppler (PwD) scores were correlated with DAS28 and compared between the clinical categories in a cross-sectional cohort of patients. In patients with a second US (longitudinal cohort), we investigated if change in US score correlated with change in DAS and evaluated the responsiveness of both methods. RESULTS: In the cross-sectional cohort with 536 patients, correlation between the B-mode score and DAS28 was significant but modest (Pearson coefficient r=0.41, P<0.0001). The same was true for the PwD score (r=0.41, P<0.0001). In the longitudinal cohort with 183 patients we also found a significant correlation between change in B-mode and in PwD score with change in DAS28 (r=0.54, P<0.0001 and r=0.46, P<0.0001, respectively). Both methods of evaluation (DAS and US) showed similar responsiveness according to standardized response mean (SRM). CONCLUSIONS: The SONAR Score is practicable and was applied by many rheumatologists in daily routine care after initial training. It demonstrates significant correlations with the degree of as well as change in disease activity as measured by DAS. On the level of the individual, the US score shows many discrepancies and overlapping results exist.
Resumo:
Purpose:To evaluate the histological features of cellular retinal fragments on the internal limiting membrane (ILM) removed during epiretinal membrane peeling surgery with and without the aid of ICG diluted in 5% glucose Methods:ILM specimens removed from 88 eyes undergoing vitrectomy and membrane peeling surgery for idiopathic epiretinal membrane between 1995 and 2003 were reviewed retrospectively. Surgery was performed in all cases by the same surgeon using the same technique. ICG was diluted with 5% glucose. Histological analysis focused on the presence and characteristics of retinal structures on the retinal surface of the ILM. Statistical analysis compared the results between group I (conventional surgery without ICG) and group II (ICG-assisted peeling) Results:Seventy-one eyes underwent EMM surgery without the aid of ICG (group I) and seventeen underwent EMM ICG-assisted surgery assisted using ICG (group II). The amount of Muller cell debris on the retinal surface of the ILM was more significant in the group I (no ICG) than in the group II (ICG) (40.8 versus 11.8; p = 0.024). Large fragments of Muller cells were more frequently observed in the group I (no ICG) than in the group II (ICG) (63.4% versus 23.5%; p= 0.003).The presence of larger retinal elements such as neural axons and vessels were observed attached to retinal face of the ILM in 5 (7%) cases of the no-ICG group. No such retinal elements were detected in any of the histological ILM specimens of the ICG-assisted group Conclusions:The use of ICG diluted with 5% glucose in the aid of ILM removal during epiretinal membrane surgery was associated with less retinal debris attached to retinal face of the ILM compared to surgery in which ICG was not used. Our findings contradict previous reports in the literature, in which use of ICG diluted with balanced salt solution (BSS) was associated with more retinal fragments attached to the retinal face of the ILM. According to our results, we hypothesize that diluting ICG with 5% glucose may decrease the adhesion of the ILM to the underlying retinal layers such that less retinal debris is removed with peeling of the ILM.
Resumo:
Objective: To evaluate the agreement between multislice CT (MSCT) and intravascular ultrasound (IVUS) to assess the in-stent lumen diameters and lumen areas of left main coronary artery (LMCA) stents. Design: Prospective, observational single centre study. Setting: A single tertiary referral centre. Patients: Consecutive patients with LMCA stenting excluding patients with atrial fibrillation and chronic renal failure. Interventions: MSCT and IVUS imaging at 912 months follow-up were performed for all patients. Main outcome measures: Agreement between MSCT and IVUS minimum luminal area (MLA) and minimum luminal diameter (MLD). A receiver operating characteristic (ROC) curve was plotted to find the MSCT cut-off point to diagnose binary restenosis equivalent to 6 mm2 by IVUS. Results: 52 patients were analysed. PassingBablok regression analysis obtained a β coefficient of 0.786 (0.586 to 1.071) for MLA and 1.250 (0.936 to 1.667) for MLD, ruling out proportional bias. The α coefficient was −3.588 (−8.686 to −0.178) for MLA and −1.713 (−3.583 to −0.257) for MLD, indicating an underestimation trend of MSCT. The ROC curve identified an MLA ≤4.7 mm2 as the best threshold to assess in-stent restenosis by MSCT. Conclusions: Agreement between MSCT and IVUS to assess in-stent MLA and MLD for LMCA stenting is good. An MLA of 4.7 mm2 by MSCT is the best threshold to assess binary restenosis. MSCT imaging can be considered in selected patients to assess LMCA in-stent restenosis
Resumo:
Conventional methods are sometimes insufficient to identify human bacterial pathogens, and alternative techniques, often molecular, are required. Matrix-assisted laser desorption ionization-time of flight mass spectrometry (MALDI-TOF MS) identified with a valid score 45.9% of 410 clinical isolates from 207 different difficult-to-identify species having required 16S rRNA gene sequencing. MALDI-TOF MS might represent an alternative to 16S rRNA gene sequencing.
Resumo:
BACKGROUND: Angiographic studies suggest that acute vasospasm within 48 h of aneurysmal subarachnoid hemorrhage (SAH) predicts symptomatic vasospasm. However, the value of transcranial Doppler within 48 h of SAH is unknown. METHODS: We analyzed 199 patients who had at least 1 middle cerebral artery (MCA) transcranial Doppler examination within 48 h of SAH onset. Abnormal MCA mean blood flow velocity (mBFV) was defined as >90 cm/s. Delayed cerebral ischemia (DCI) was defined as clinical deterioration or radiological evidence of infarction due to vasospasm. RESULTS: Seventy-six patients (38%) had an elevation of MCA mBFV >90 cm/s within 48 h of SAH onset. The predictors of elevated mBFV included younger age (OR = 0.97 per year of age, p = 0.002), admission angiographic vasospasm (OR = 5.4, p = 0.009) and elevated white blood cell count (OR = 1.1 per 1,000 white blood cells, p = 0.003). Patients with elevated mBFV were more likely to experience a 10 cm/s fall in velocity at the first follow-up than those with normal baseline velocities (24 vs. 10%, p < 0.01), suggestive of resolving spasm. DCI developed in 19% of the patients. An elevated admission mBFV >90 cm/s during the first 48 h (adjusted OR = 2.7, p = 0.007) and a poor clinical grade (Hunt-Hess score 4 or 5, OR = 3.2, p = 0.002) were associated with a significant increase in the risk of DCI. CONCLUSION: Early elevations of mBFV correlate with acute angiographic vasospasm and are associated with a significantly increased risk of DCI. Transcranial Doppler ultrasound may be an early useful tool to identify patients at higher risk to develop DCI after SAH.
Resumo:
The objective of this work was to validate microsatellite markers associated with resistance to soybean cyst nematode (Heterodera glycines Ichinohe) races 3 and 14, in soybean (Glycine max L.) genotypes, for use in marker-assisted selection (MAS) programs. Microsatellites of soybean linkage groups A2, D2 and G were tested in two populations, and their selection efficiencies were determined. The populations were 65 F2:3 families from Msoy8001 (resistant) x Conquista (susceptible) cross, and 66 F2:3 families of S5995 (resistant) x Renascença (susceptible) cross, evaluated for resistance to races 3 and 14, respectively. Families with female index up to 30% were considered moderately resistant. Markers of A2 and G linkage groups were associated with resistance to race 3. Markers Satt309 and GMENOD2B explained the greatest proportion of phenotypic variance in the different groups. The combinations Satt309+GMENOD2B and Satt309+Satt187 presented 100% selection efficiency. Resistance to race 14 was associated with markers of G linkage group, and selection efficiency in the Satt309+Satt356 combination was 100%. The selection differential obtained by phenotypic and marker assisted selection showed that both can result in similar gains.
Resumo:
OBJECTIVES: Determine if arm veins are good conduits for infrainguinal revascularisation and should be used when good quality saphenous vein is not available. DESIGN: Retrospective study. MATERIALS AND METHODS: We evaluated a consecutive series of infrainguinal bypass (IB) using arm vein conduits from March 2001 to December 2006.We selected arm vein by preoperative ultrasound mapping to identify suitable veins. We measured vein diameter and assessed vein wall quality. We followed patients with systematic duplex imaging at 1 week, 1, 3, 6 and 12 months, and annually thereafter. We treated significative stenoses found during the follow-up. RESULTS: We performed 56 infrainguinal revascularisation using arm vein conduits in 56 patients. Primary patency rates at 1, 2 and 3 years were 65%, 51% and 47%. Primary assisted patencies at 1, 2 and 3 years were 96%, 96% and 82%. Secondary patency rates at 1, 2 and 3 years were 92%, 88% and 88%. The three-year limb salvage rate was 88%. CONCLUSIONS: We conclude that infrainguinal bypass using arm vein for conduits gives good patency rates, if selected by a preoperative US mapping to use the best autogenous conduit available.
Resumo:
The present study describes some of the applications of ultrasound in bone surgery, based on the presentation of two clinical cases. The Piezosurgery® ultrasound device was used (Tecnología Mectron Medical, Carasco, Italy). In one case the instrument was used to harvest a chin bone graft for placement in a bone defect at level 1.2, while in the other case a bony window osteotomy was made in the external wall of the maxillary sinus, in the context of a sinus membrane lift procedure. The Piezosurgery® device produces specific ultrasound frequency modulation (25-29 kHz), and has been designed to secure increased precision in application to bone surgery. This instrument produces selective sectioning of the mineralized bone structures, and causes less intra- and postoperative bleeding. One of the advantages of the Piezosurgery® device is that it can be used for maxillary sinus lift procedures in dental implant placement. In this context it considerably lessens the risk of sinus mucosa laceration by preparing the bony window in the external wall of the upper maxilla, and can be used to complete the lifting maneuver. The use of ultrasound in application to hard tissues can be regarded as a slow technique compared with the conventional rotary instruments, since it requires special surgical skill and involves a certain learning curve.