932 resultados para polyester resins
Resumo:
PURPOSE: To meta-analyze the literature on the clinical performance of Class V restorations to assess the factors that influence retention, marginal integrity, and marginal discoloration of cervical lesions restored with composite resins, glass-ionomer-cement-based materials [glass-ionomer cement (GIC) and resin-modified glass ionomers (RMGICs)], and polyacid-modified resin composites (PMRC). MATERIALS AND METHODS: The English literature was searched (MEDLINE and SCOPUS) for prospective clinical trials on cervical restorations with an observation period of at least 18 months. The studies had to report about retention, marginal discoloration, marginal integrity, and marginal caries and include a description of the operative technique (beveling of enamel, roughening of dentin, type of isolation). Eighty-one studies involving 185 experiments for 47 adhesives matched the inclusion criteria. The statistical analysis was carried out by using the following linear mixed model: log (-log (Y /100)) = β + α log(T ) + error with β = log(λ), where β is a summary measure of the non-linear deterioration occurring in each experiment, including a random study effect. RESULTS: On average, 12.3% of the cervical restorations were lost, 27.9% exhibited marginal discoloration, and 34.6% exhibited deterioration of marginal integrity after 5 years. The calculation of the clinical index was 17.4% of failures after 5 years and 32.3% after 8 years. A higher variability was found for retention loss and marginal discoloration. Hardly any secondary caries lesions were detected, even in the experiments with a follow-up time longer than 8 years. Restorations placed using rubber-dam in teeth whose dentin was roughened showed a statistically significantly higher retention rate than those placed in teeth with unprepared dentin or without rubber-dam (p < 0.05). However, enamel beveling had no influence on any of the examined variables. Significant differences were found between pairs of adhesive systems and also between pairs of classes of adhesive systems. One-step self-etching had a significantly worse clinically index than two-step self-etching and three-step etch-and-rinse (p = 0.026 and p = 0.002, respectively). CONCLUSION: The clinical performance is significantly influenced by the type of adhesive system and/or the adhesive class to which the system belongs. Whether the dentin/enamel is roughened or not and whether rubberdam isolation is used or not also significantly influenced the clinical performance. Composite resin restorations placed with two-step self-etching and three-step etch-and-rinse adhesive systems should be preferred over onestep self-etching adhesive systems, GIC-based materials, and PMRCs.
Resumo:
Työssä tutkittiin laboratorio-olosuhteissa germaniumin talteenottoa happamista hydrometallurgisista sulfaattiliuoksista käyttäen kaupallisia ioninvaihtohartseja. Germaniumin talteenottoa tutkittiin sekä tasapaino- että kolonnikokein syöttöliuoksista joiden pH oli alueella 0,8–3,0. Tutkituista hartseista parhaiten germanium voitiin erottaa käyttäen emäsmuotoista N-metyyli-D-glukamiini-tyyppistä ioninvaihtohartsia (esim. Rohm & Haasin IRA-743). Germaniumille määritettiin adsorptioisotermit tasapainokokein sekä emäs- että happomuotoisilla hartseilla. Adsorptioisotermien perusteella parhaiten germa-niumia adsorboi emäsmuotoinen IRA-743-hartsi kun liuoksen alku-pH oli tutkitun alueen korkein. Lämpötilassa 25 °C kapasiteetti oli 114 mg Ge/g. Tasapainokokein määritettiin emäsmuotoisilla hartseilla germaniumin lisäksi myös kuparia ja kobolttia sisältävillä liuoksilla Ge:n jakaantumisvakiot sekä erotustekijät Ge/Cu ja Ge/Co. Havaittiin, että IRA-743:lla alku-pH:ssa 3,0 Ge:n jakaantumisvakiot sekä erotustekijät Ge/Cu ja Ge/Co olivat selvästi suuremmat kuin muilla tutkituilla hartseilla. Arseenin, nikkelin, sinkin ja rauta(III):n adsorboitumista emäsmuotoiseen IRA-743:een tutkittiin monimetallisella liuoksella syöttöliuoksen pH:n ollessa alueella 1,4–3,6. Kokeissa havaittiin, että hartsi adsorboi hieman Ni:a ja Zn:a tasapaino-pH:n ollessa yli 5,5. Arseenia ei tutkitulla pH-alueella havaittu adsorboituvan. Lisäksi huomattiin, että rauta alkaa saostua pH:n ollessa hieman alle kolme. Kolonnikokeissa havaittiin, että emäsmuotoinen IRA-743-hartsi toimii hyvin germaniumin talteenotossa myös kolonnissa. Pelkästään germaniumia ja kobolttia sisältäneellä liuoksella hartsin dynaamiseksi kapasiteetiksi saatiin 54 mg Ge/g. Germaniumin eluointi IRA-743:sta onnistui parhaiten 0,5 M H2SO4:lla. Kolonnikokeita IRA-743:lla ajettiin myös monimetallisilla liuoksilla, mutta silloin havaittiin hartsin kapasiteetin pienenevän hartsin myrkyttymisen takia.
Resumo:
The cuticle is an essential diffusion barrier on aerial surfaces of land plants whose structural component is the polyester cutin. The PERMEABLE CUTICLE1/ABCG32 (PEC1) transporter is involved in plant cuticle formation in Arabidopsis. The gpat6 pec1 and gpat4 gapt8 pec1 double and triple mutants are characterized. Their PEC1-specific contributions to aliphatic cutin composition and cuticle formation during plant development are revealed by gas chromatography/mass spectrometry and Fourier-transform infrared spectroscopy. The composition of cutin changes during rosette leaf expansion in Arabidopsis. C16:0 monomers are in higher abundance in expanding than in fully expanded leaves. The atypical cutin monomer C18:2 dicarboxylic acid is more prominent in fully expanded leaves. Findings point to differences in the regulation of several pathways of cutin precursor synthesis. PEC1 plays an essential role during expansion of the rosette leaf cuticle. The reduction of C16 monomers in the pec1 mutant during leaf expansion is unlikely to cause permeability of the leaf cuticle because the gpat6 mutant with even fewer C16:0 monomers forms a functional rosette leaf cuticle at all stages of development. PEC1/ABCG32 transport activity affects cutin composition and cuticle structure in a specific and non-redundant fashion.
Resumo:
Tämän tutkimuksen tarkoituksena oli määrittää melamiinipinnoituslinjalla käytettäville eri pinnoituskalvoille linjan käytön kannalta optimaaliset puristusparametrit. Tutkimuksessa vertailtiin erityisesti puristuslämpötilan ja -ajan vaikutusta pinnoitettujen levyjen pinnoitteiden kypsymiseen. Pinnoitteiden kypsyminen mitattiin pääasiassa kypsyystestien avulla. Tulosten pohjalta laadittiin 6 eri pinnoitusreseptiä, joihin pinnoitteet jaoteltiin. Yksi pinnoitusresepti pitää sisällään tiedot käytettävistä puristusparametreista, eli puristuspaineesta, -lämpötilasta ja -ajasta. Testien tuloksia analysoitaessa havaittiin eri pinnoitteiden käyttäytyvän eri tavoin. Osa pinnoitteista kesti korkeampia lämpötiloja, osa taas vaati pidemmän puristusajan sopivan kypsyysasteen saavuttamiseksi. Sopiviin puristusaikoihin havaittiin vaikuttavan erityisesti käytetyn hartsin reaktiivisuus ja kalvoissa käytetyn pigmenttiväriaineen tummuus.
Resumo:
This study aimed at comparing the efficiency of various sampling materials for the collection and subsequent analysis of organic gunshot residues (OGSR). To the best of our knowledge, it is the first time that sampling devices were investigated in detail for further quantitation of OGSR by LC-MS. Seven sampling materials, namely two "swab"-type and five "stub"-type collection materials, were tested. The investigation started with the development of a simple and robust LC-MS method able to separate and quantify molecules typically found in gunpowders, such as diphenylamine or ethylcentralite. The evaluation of sampling materials was then systematically carried out by first analysing blank extracts of the materials to check for potential interferences and determining matrix effects. Based on these results, the best four materials, namely cotton buds, polyester swabs, a tape from 3M and PTFE were compared in terms of collection efficiency during shooting experiments using a set of 9 mm Luger ammunition. It was found that the tape was capable of recovering the highest amounts of OGSR. As tape-lifting is the technique currently used in routine for inorganic GSR, OGSR analysis might be implemented without modifying IGSR sampling and analysis procedure.
Resumo:
The SEC and VPO behaviour of hydroxyl-terminated polybutadiene resins was investigated using toluene as solvent and polybutadiene and polystyrene as standards. The results show that molar mass obtained depend on the nature of the standards used in the calibration, specialy in SEC analysis.
Resumo:
A flow injection spectrophotometric method was developed for determining aspartame in sweeteners. Sample was dissolved in water and 250 µL of the solution was injected into a carrier stream of 5.0 x 10-5 mol L-1 sodium borate solution. The sample flowed through a column (14 cm x 2.0 mm) packed with Zn3(PO4)2 immobilized in a polymeric matrix of polyester resin and Zn(II) ions were released from the solid-phase reactor by formation of the Zn(II)-aspartame complex. The mixture merged with a stream of borate buffer solution (pH 9.0) containing 0.030 % (m/v) alizarin red S and the Zn(II)-alizarin red complex formed was measured spectrophotometrically at 540 nm. The calibration graph for aspartame was linear in the concentration range from 10 to 80 µg mL-1 with a detection limit of 4 µg mL-1 of aspartame. The RSD was 0.3 % for a solution containing 40 µg mL-1 aspartame (n = 10) and seventy results were obtained per hour. The proposed method was applied for determining aspartame in commercial sweeteners.
Resumo:
Phenil glycidyl ether (PGE), a monofunctional diluent, has been used in epoxy resins formulations in order to increase the toughness of the epoxy molded composite. In a systematic study concerning its influence in the cure kinetics of the epoxy resin, it was used in concentrations of 2,5; 5,0; 10 and 20% in relation to a diglycidyl ether bisphenol-A (DGEBA)/diamino diphenil-sulfone (DDS) base matrix. Dynamic and isothermal scanning analysis were carried out using a differential scanning calorimety (DSC) equipment. For all the concentrations of PGE, a n order kinetics was observed, with n varing between 0,35 -- 0,91 as a function of the increase in the PGE concentration.
Resumo:
The developments in stationary phase synthesis and capillary column technology, have opened new perspectives in analysis of high molecular mass compounds (³600 daltons) and thermolabile organic compounds by High Temperature High Resolution Gas Chromatography (HT-HRGC). HT-HRGC is a new analytical borderline and its application to the analysis of high molecular mass compounds is still in its infancy. The apolar and medium polar gum phases can now be operated at temperatures up to 400-480ºC, being used for the analysis of n-alcanes up to C-100, lipids, oligosaccharides, industrial resins, polyglycerols, cyclodextrins, porphyrins, etc. This technique should play a leading role as a powerful tool, for many different analysis types, in multidisciplinary fields of Science.
Resumo:
This thesis focuses on fibre coalescers whose efficiency is based on the surface properties/characteristics. They have the ability to preferentially wet or interact with one or more of the fluids to be separated. Thus, the interfacial phenomena governing the separation efficiency of the coalescers is investigated depending on physical factors such as flowrates, phase ratios and coalescer packing density. Design of process equipment to produce and separate of the emulsions was carried out.The experimentation was carried out to test the separation efficiency of the coalescing medias, namely fibreglass, polyester I and polyester II. The performances of the coalescing medias were assessed via droplet size information. In conclusion, the objectives (design of process equipment and experimentation) were achieved. Fibre glass was the best coalescing media, next was polyester I and then finally polyester II. Droplets sizes increased with decreased flowrates and increased packing density of the coalescer. Phase ratio had effect on the droplet sizes of the feed but had no effect on the coalescence of droplets of the feed.
Resumo:
This paper reviews the most important methods used to characterize the porosity of styrene-divinylbenzene resins. Methods such as adsorption of nitrogen for determination of surface area and mercury intrusion porosimetry for characterization of pore size distribution are related.
Resumo:
The counteranion exchange of quaternary 1,2,3-triazolium salts was examined using a simple method that permitted halide ions to be swap for a variety of anions using an anion exchange resin (A¯ form). The method was applied to 1,2,3-triazolium-based ionic liquids and the iodideto- anion exchange proceeded in excellent to quantitative yields, concomitantly removing halide impurities. Additionally, an anion exchange resin (N3¯ form) was used to obtain the benzyl azide from benzyl halide under mild reaction. Likewise, following a similar protocol, bis(azidomethyl)arenes were also synthesized in excellent yields. The results of a proton NMR spectroscopic study of simple azolium-based ion pairs are discussed, with attention focused on the significance of the charged-assisted (CH)+···anion hydrogen bonds of simple azolium systems such as 1-butyl-3-methylimidazolium and 1-benzyl-3-methyl-1,2,3-triazolium salts.
Resumo:
The counteranion exchange of quaternary 1,2,3-triazolium salts was examined using a simple method that permitted halide ions to be swap for a variety of anions using an anion exchange resin (A¯ form). The method was applied to 1,2,3-triazolium-based ionic liquids and the iodideto- anion exchange proceeded in excellent to quantitative yields, concomitantly removing halide impurities. Additionally, an anion exchange resin (N3¯ form) was used to obtain the benzyl azide from benzyl halide under mild reaction. Likewise, following a similar protocol, bis(azidomethyl)arenes were also synthesized in excellent yields. The results of a proton NMR spectroscopic study of simple azolium-based ion pairs are discussed, with attention focused on the significance of the charged-assisted (CH)+···anion hydrogen bonds of simple azolium systems such as 1-butyl-3-methylimidazolium and 1-benzyl-3-methyl-1,2,3-triazolium salts.
Resumo:
The counteranion exchange of quaternary 1,2,3-triazolium salts was examined using a simple method that permitted halide ions to be swap for a variety of anions using an anion exchange resin (A¯ form). The method was applied to 1,2,3-triazolium-based ionic liquids and the iodideto- anion exchange proceeded in excellent to quantitative yields, concomitantly removing halide impurities. Additionally, an anion exchange resin (N3¯ form) was used to obtain the benzyl azide from benzyl halide under mild reaction. Likewise, following a similar protocol, bis(azidomethyl)arenes were also synthesized in excellent yields. The results of a proton NMR spectroscopic study of simple azolium-based ion pairs are discussed, with attention focused on the significance of the charged-assisted (CH)+···anion hydrogen bonds of simple azolium systems such as 1-butyl-3-methylimidazolium and 1-benzyl-3-methyl-1,2,3-triazolium salts.
Resumo:
A demonstractive experiment was proposed in order to verify students' habilities in recognizing the presence and nature of ions in solutions, before and after their passage through ion-exchange columns. The students have no previous contact with ion-exchange resins, so they must deduce how they work and explain the experimental facts. The performance of classes, at different stages of learning, is compared and discussed.