966 resultados para photon counting detector
Resumo:
We present a measurement of the semileptonic mixing asymmetry for B0 mesons, asld, using two independent decay channels: B0→μ +D -X, with D -→K +π -π -; and B0→μ +D *-X, with D * -→D ̄0π -, D ̄0→ K +π - (and charge conjugate processes). We use a data sample corresponding to 10.4fb -1 of pp̄ collisions at √s=1.96TeV, collected with the D0 experiment at the Fermilab Tevatron collider. We extract the charge asymmetries in these two channels as a function of the visible proper decay length of the B0 meson, correct for detector-related asymmetries using data-driven methods, and account for dilution from charge-symmetric processes using Monte Carlo simulation. The final measurement combines four signal visible proper decay length regions for each channel, yielding asld=[0.68±0.45(stat)±0.14(syst)]%. This is the single most precise measurement of this parameter, with uncertainties smaller than the current world average of B factory measurements. © 2012 American Physical Society.
Resumo:
Results from the first study of isolated-photon+jet correlations in relativistic heavy ion collisions are reported. The analysis uses data from PbPb collisions at a centre-of-mass energy of 2.76TeV per nucleon pair corresponding to an integrated luminosity of 150μb-1 recorded by the CMS experiment at the LHC. For events containing an isolated photon with transverse momentum pTγ>60GeV/c and an associated jet with pTJet>30GeV/c, the photon+jet pT imbalance is studied as a function of collision centrality and compared to pp data and pythia calculations at the same collision energy. Using the pTγ of the isolated photon as an estimate of the momentum of the associated parton at production, this measurement allows an unbiased characterisation of the in-medium parton energy loss. For more central PbPb collisions, a significant decrease in the ratio pTJet/pTγ relative to that in the pythia reference is observed. Furthermore, significantly more pTγ>60GeV/c photons in PbPb are observed not to have an associated pTJet>30GeV/c jet, compared to the reference. However, no significant broadening of the photon+jet azimuthal correlation is observed. © 2012 CERN.
Resumo:
Changing the sample's temperature from 200 K to 535 K, we observed 670-fold enhancement of a phonon-assisted upconversion emission at ≈754 nm obtained from a Nd3+-doped tellurite glass excited by 5 ns laser pulses at 805 nm. A rate-equation model, including the relevant energy levels and temperature dependent transition rates, is proposed to describe the process. The results fit well with the data when one considers the nonradiative transitions contributing for the 754 nm luminescence are promoted by an effective phonon mode with energy of 700 cm-1. © 2013 American Institute of Physics.
Resumo:
Characterization by micro-Raman spectroscopy of polymeric materials used as nuclear track detectors reveals physico-chemical and morphological information on the material's molecular structure. In this work, the nuclear track detector poly(allyl diglycol carbonate), or Columbia Resin 39 (CR-39), was characterized according to the fluence of alpha particles produced by a 226Ra source and chemical etching time. Therefore, damage of the CR-39 chemical structure due to the alpha-particle interaction with the detector was analyzed at the molecular level. It was observed that the ionization and molecular excitation of the CR-39 after the irradiation process entail cleavage of chemical bonds and formation of latent track. In addition, after the chemical etching, there is also loss of polymer structure, leading to the decrease of the group density C-O-C (∼888 cm-1), CH=CH (∼960 cm -1), C-O (∼1110 cm-1), C-O-C (∼1240 cm -1), C-O (∼1290 cm-1), C-O (∼1741 cm -1), -CH2- (∼2910 cm-1), and the main band -CH2- (∼2950 cm-1). The analyses performed after irradiation and chemical etching led to a better understanding of the CR-39 molecular structure and better comprehension of the process of the formation of the track, which is related to chemical etching kinetics. Copyright © 2013 Society for Applied Spectroscopy.
Resumo:
Studies of the structure of excited baryons are key factors to the N* program at Jefferson Lab (JLab). Within the first year of data taking with the Hall B CLAS12 detector following the 12 GeV upgrade, a dedicated experiment will aim to extract the N* electrocouplings at high photon virtualities Q 2. This experiment will allow exploration of the structure of N* resonances at the highest photon virtualities ever achieved, with a kinematic reach up to Q2 = 12 GeV2. This high-Q 2 reach will make it possible to probe the excited nucleon structures at distance scales ranging from where effective degrees of freedom, such as constituent quarks, are dominant through the transition to where nearly massless bare-quark degrees of freedom are relevant. In this document, we present a detailed description of the physics that can be addressed through N* structure studies in exclusive meson electroproduction. The discussion includes recent advances in reaction theory for extracting N* electrocouplings from meson electroproduction off protons, along with Quantum Chromodynamics (QCD)-based approaches to the theoretical interpretation of these fundamental quantities. This program will afford access to the dynamics of the nonperturbative strong interaction responsible for resonance formation, and will be crucial in understanding the nature of confinement and dynamical chiral symmetry breaking in baryons, and how excited nucleons emerge from QCD. © 2013 World Scientific Publishing Company.
Resumo:
Measurements of inclusive jet and dijet production cross sections are presented. Data from LHC proton-proton collisions at √s=7 TeV, corresponding to 5.0 fb-1 of integrated luminosity, have been collected with the CMS detector. Jets are reconstructed up to rapidity 2.5, transverse momentum 2 TeV, and dijet invariant mass 5 TeV, using the anti-k T clustering algorithm with distance parameter R=0.7. The measured cross sections are corrected for detector effects and compared to perturbative QCD predictions at next-to-leading order, using five sets of parton distribution functions. © 2013 CERN.
Resumo:
Many epidemiological studies and clinical trials have been performed concerning actinic keratoses. The most eligible endpoint in the majority of articles is counting of actinic keratoses before and after treatments, nevertheless some authors support that this is not a reliable form of evaluation. The aim of this study was to evaluate the actinic keratoses counting by various raters and suggest approaches to increase the reliability. Cross-sectional study: forty-three patients were evaluated by four raters (inter- and intra-rater assessment) on the face and forearms. The mean actinic keratoses counts on the face and forearms were 7.7 and 9.1. The overall agreement among the raters for the facial and forearm actinic keratoses was 0.74 and 0.77. The intra-rater assessment showed high rates of agreement for the face (ICC = 0.93) and forearms (ICC = 0.83). Higher agreement occurred when counting up to five lesions. Four raters led to increased measurement variability and loss of reliability. Higher rates of agreement may be achieved with small number of lesions, limitation and/or segmentation of body areas to reduce their number, in AK prevention designs, are strategies that may lead to a greater reliability of these measurements. © 2013 Springer-Verlag Berlin Heidelberg.
Resumo:
The results of searches for new resonances decaying to a pair of massive vector bosons (WW, WZ, ZZ) are presented. All searches are performed using 5.0 fb-1 of proton-proton collisions, at TeV of center of mass energy, collected by the Compact Muon Solenoid detector at the Large Hadron Collider. No significant excess compared to the standard model background expectation is observed, and upper limits at 95% confidence level are set on the production cross section times the branching fraction of hypothetical particles decaying to a pair of vector bosons. The results are interpreted in the context of several benchmark models, such as the Randall-Sundrum gravitons, the Sequential Standard Model W′, and Technicolor. Graviton resonances in the Randall-Sundrum model with masses smaller than 940 GeV/c2, for coupling parameter k/MPl = 0.05 are excluded. Bulk (ADPS) Randall-Sundrum gravitons with masses smaller than 610 GeV/c2 are excluded, for k/MPl = 0.05. Sequential Standard Model W′ with masses smaller than 1143 GeV/c2 are excluded, as well as ρTC in the 167-687 GeV/c2 mass range, in Low Scale Technicolor models with M(πTC) = 3/4 M(ρTC) - 25 GeV/c2. © 2013 IOP Publishing Ltd.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Pós-graduação em Pesquisa e Desenvolvimento (Biotecnologia Médica) - FMB
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
The HPLC technique with UV-Vis detection was employed in the analysis of cocaine content in apprehended samples of cocaine and crack. A peak signal for cocaine was obtained in 3.5 minutes run by using acetonitrile/water (95:5v/v) as a mobile phase. Optimized spectrophotometric signal was obtained at a wavelength of 224 nm. The analytical curve from 1.0 to 40.0 ppm of cocaine was obtained, showing a linear correlation coefficient of 0.9989, with detection and quantification limits of 0.75 ppm and 3.78 ppm, respectively. This methodology was employed at the dosage of confiscated samples of cocaine and crack in the Scientific Police Laboratory of Ribeirão Preto-SP city.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
A determinação das concentrações sanguíneas de antimaláricos empregando métodos rápidos, simples e sensíveis, representa importante ferramenta para otimização dos esquemas terapêuticos adotados atualmente no Brasil. Neste sentido, este trabalho objetivou a validação de uma metodologia analítica por cromatografia líquida de alta eficiência com detecção no ultravioleta para determinação de cloroquina em amostras de sangue total adsorvidas em papel de filtro, oriundas de pacientes com malária vivax. Foram avaliados: precisão intra e inter ensaio, recuperação, limites de detecção e de quantificação, robustez, estabilidade, linearidade e seletividade. Os resultados demonstraram que os coeficientes de variação intra ensaio em concentrações de 100 a 1000 ng/mL variou de 6 a 10% tanto para cloroquina, quanto para desetilcloroquina. Os coeficientes de variação inter ensaio em concentrações de 100 a 1000 ng/mL variaram de 5 a 10% e 4 a 10% para cloroquina e desetilcloroquina, respectivamente. Os limites de detecção foram 62.5ng/mL para cloroquina e 50.0ng/mL para desetilcloroquina e os limites de quantificação foram 100ng/mL para ambos os analitos. A recuperação em concentração de 100 a 1000 ng/mL variou de 90 a 105% e 95 a 105%, para cloroquina e desetilcloroquina, respectivamente. O método foi linear em intervalo de concentração de 100 ng/mL a 2000 para cloroquina e de 100 a 800 ng/mL para desetilcloroquina. O método foi robusto para pequenas variações de fluxo, pH da fase móvel e composição da fase orgânica. Não foram observados interferentes no procedimento validado dentre aqueles fármacos utilizados no tratamento da malária. A determinação de cloroquina e desetilcloroquina em pacientes com malária vivax cujos valores médios foram de 1266±455 ng/mL e 357±165ng/mL, caracterizaram a aplicabilidade do procedimento validado para a determinação deste antimalárico nestes pacientes.
Resumo:
Compreendida por um dispositivo para determinação do espectro de substâncias sólidas e líquidas, com possibilidades de medições in vivo, e exibindo diversas vantagens sobre os dispositivos precedentes, que apresenta uma relação sinalruído excelente e comparável a uma câmara fotoacústica com microfone convencional com a grande vantagem de ser aberta. O dispositivo é composto por um detector transparente de radiação de Tantalato de Lítio, ao qual é acoplada, por contato físico, a amostra a ser analisada. Os eletrodos do detector são em formato de anel, sendo recobertos por uma camada de óxido de índio-estanho (ITO). Ao detector deve ser acoplado um amplificador eletrónico com elevada impedância de entrada.