972 resultados para minimally invasive treatment
Resumo:
We present a video of an ultrasound-guided laparoscopic surgical management of a large uterine scar isthmocele connected with the extra-amniotic space in early pregnancy. A case of a pregnant patient who was diagnosed with a large isthmocele connected with the extra-amniotic space on routine ultrasound at 8 weeks of gestational age is presented. The uterine defect was successfully sutured laparoscopically under ultrasound guidance. The pregnancy continued uneventfully, and a healthy baby was delivered via cesarean section at 38 weeks gestational age.
Resumo:
Herein is presented a technique for minimally invasive sentinel node mapping. The patient had apparently early stage endometrial cancer. Sentinel node mapping was performed using a hysteroscopic injection of indocyanine green followed by laparoscopic sentinel node detection via near-infrared fluorescence. This technique ensures delineation of lymphatic drainage from the tumor area, thus achieving accurate detection of sentinel nodes.
Resumo:
Three groups of Atlantic salmon were kept at a constant temperature of 4, 10 and 14 °C. The adipose fins were removed; six fish/group were sampled at 11 subsequent time points post-clipping. Samples were prepared for histopathological examination to study the course of re-epithelization. A score sheet was developed to assess the regeneration of epidermal and dermal cell types. Wounds were covered by a thin epidermal layer between 4 and 6 h post-clipping at 10 and 14 °C. In contrast, wound closure was completed between 6 and 12 h in fish held at a constant temperature of 4 °C. By 18 h post-clipping, superficial cells, cuboidal cells, prismatic basal cells and mucous cells were discernible in all temperature groups, rapidly progressing towards normal epidermal structure and thickness. Within the observation period, only minor regeneration was found in the dermal layers. A positive correlation between water temperature and healing rates was established for the epidermis. The rapid wound closure rate, epidermal normalization and the absence of inflammatory reaction signs suggest that adipose fin clipping under anaesthesia constitutes a minimally invasive method that may be used to mark large numbers of salmon presmolts without compromising fish welfare.
Resumo:
Nucleus pulposus replacements have been subjected to highly controversial discussions over the last 40 years. Their use has not yet resulted in a positive outcome to treat herniated disc or degenerated disc disease. The main reason is that not a single implant or tissue replacement was able to withstand the loads within an intervertebral disc. Here, we report on the development of a photo-polymerizable poly(ethylene glycol)dimethacrylate nano-fibrillated cellulose composite hydrogel which was tuned according to native tissue properties. Using a customized minimally-invasive medical device to inject and photopolymerize the hydrogel insitu, samples were implanted through an incision of 1 mm into an intervertebral disc of a bovine organ model to evaluate their long-term performance. When implanted into the bovine disc model, the composite hydrogel implant was able to significantly re-establish disc height after surgery (p < 0.0025). The height was maintained after 0.5 million loading cycles (p < 0.025). The mechanical resistance of the novel composite hydrogel material combined with the minimally invasive implantation procedure into a bovine disc resulted in a promising functional orthopedic implant for the replacement of the nucleus pulposus.
Resumo:
Peripheral arteriovenous malformations (AVM) remain most challenging among various congenital vascular malformations to be treated. Here we present three illustrative patients with Yakes type IIIb and type IV AVM at the plantar aspect of the foot who were successfully treated by minimally invasive embolization. The value of the Yakes AVM classification system to guide the therapeutic decision making by directing specific therapeutic procedures to specific AVM types defined by their angioarchitecture is demonstrated. Direct percutaneous AVM puncture with coiling of aneurysmal outflow vein and subsequent ethanol embolization is shown. Finally, the report illustrates that several AVM types can coexist.
Resumo:
Purpose: To examine the effect of obesity and gestational weight gain on heart rate variability (HRV), oxygenation (HbO 2 and SpO2), hemoglobin A1c (HbA1c) and the frequency of pregnancy complications in obese (O) and non-obese (NO) women.^ Design: The study was an observational comparison study with a repeated measures design. ^ Setting: The setting was a low risk prenatal, university clinic located in a large southeastern metropolitan city. ^ Sample: The sample consisted of a volunteer group of 41 pregnant women who were observed at the three time points of 20, 28, and 36 weeks gestation. ^ Analysis: Analysis included general linear modeling with repeated measures to test for group differences with changes over time on vagal response, HbA1c, and oxygenation. Odds ratios were computed to compare the frequency of birth outcomes. ^ Findings: The interaction effect of time between O and NO women on HbO2 was significant. The mean HP, RSA, and HbO2 changed significantly over time within the NO women. The mean HbA 1c increased significantly over time within the O women. Women with excess gestational weight gain had significantly lower heart period than women with weight gain within the IOM recommendations. Obese women were more likely to have Group B streptococcal infections, gestational hypertension, give birth by cesarean or instrument assistance, and have at least one postnatal event. ^ Conclusions: Monitoring HRV, oxygenation, and HbA1c using minimally invasive measures may permit early identification of alterations in autonomic response. Implementation of interventions to promote vagal tone may help to reduce risks for adverse perinatal outcomes related to obesity. Future studies should examine the effect of obesity on the vagal response and perinatal outcomes. ^
Resumo:
Automatic analysis of minimally invasive surgical (MIS) video has the potential to drive new solutions that alleviate existing needs for safer surgeries: reproducible training programs, objective and transparent assessment systems and navigation tools to assist surgeons and improve patient safety. As an unobtrusive, always available source of information in the operating room (OR), this research proposes the use of surgical video for extracting useful information during surgical operations. Methodology proposed includes tools' tracking algorithm and 3D reconstruction of the surgical field. The motivation for these solutions is the augmentation of the laparoscopic view in order to provide orientation aids, optimal surgical path visualization, or preoperative virtual models overlay
Resumo:
Auxetic materials (or metamaterials) are those with a negative Poisson ratio (NPR) and display the unexpected property of lateral expansion when stretched, as well as an equal and opposing densification when compressed. Such geometries are being progressively employed in the development of novel products, especially in the fields of intelligent expandable actuators, shape morphing structures and minimally invasive implantable devices. Although several auxetic and potentially auxetic geometries have been summarized in previous reviews and research, precise information regarding relevant properties for design tasks is not always provided. In this study we present a comparative study of two-dimensional and three-dimensional auxetic geometries carried out by means of computer-aided design and engineering tools (from now on CAD–CAE). The first part of the study is focused on the development of a CAD library of auxetics. Once the library is developed we simulate the behavior of the different auxetic geometries and elaborate a systematic comparison, considering relevant properties of these geometries, such as Poisson ratio(s), maximum volume or area reductions attainable and equivalent Young's modulus, hoping it may provide useful information for future designs of devices based on these interesting structures.
Resumo:
Enhanced learning environments are arising with great success within the field of cognitive skills training in minimally invasive surgery (MIS) because they provides multiple benefits since they avoid time, spatial and cost constraints. TELMA [1,2] is a new technology enhanced learning platform that promotes collaborative and ubiquitous training of surgeons. This platform is based on four main modules: an authoring tool, a learning content and knowledge management system, an evaluation module and a professional network. TELMA has been designed and developed focused on the user; therefore it is necessary to carry out a user validation as final stage of the development. For this purpose, e-MIS validity [3] has been defined. This validation includes usability, contents and functionality validities both for the development and production stages of any e-Learning web platform. Using e-MIS validity, the e-Learning is fully validated since it includes subjective and objective metrics. The purpose of this study is to specify and apply a set of objective and subjective metrics using e-MIS validity to test usability, contents and functionality of TELMA environment within the development stage.
Resumo:
INTRODUCTION: Objective assessment of motor skills has become an important challenge in minimally invasive surgery (MIS) training.Currently, there is no gold standard defining and determining the residents' surgical competence.To aid in the decision process, we analyze the validity of a supervised classifier to determine the degree of MIS competence based on assessment of psychomotor skills METHODOLOGY: The ANFIS is trained to classify performance in a box trainer peg transfer task performed by two groups (expert/non expert). There were 42 participants included in the study: the non-expert group consisted of 16 medical students and 8 residents (< 10 MIS procedures performed), whereas the expert group consisted of 14 residents (> 10 MIS procedures performed) and 4 experienced surgeons. Instrument movements were captured by means of the Endoscopic Video Analysis (EVA) tracking system. Nine motion analysis parameters (MAPs) were analyzed, including time, path length, depth, average speed, average acceleration, economy of area, economy of volume, idle time and motion smoothness. Data reduction was performed by means of principal component analysis, and then used to train the ANFIS net. Performance was measured by leave one out cross validation. RESULTS: The ANFIS presented an accuracy of 80.95%, where 13 experts and 21 non-experts were correctly classified. Total root mean square error was 0.88, while the area under the classifiers' ROC curve (AUC) was measured at 0.81. DISCUSSION: We have shown the usefulness of ANFIS for classification of MIS competence in a simple box trainer exercise. The main advantage of using ANFIS resides in its continuous output, which allows fine discrimination of surgical competence. There are, however, challenges that must be taken into account when considering use of ANFIS (e.g. training time, architecture modeling). Despite this, we have shown discriminative power of ANFIS for a low-difficulty box trainer task, regardless of the individual significances between MAPs. Future studies are required to confirm the findings, inclusion of new tasks, conditions and sample population.
Resumo:
Minimally invasive surgery is a highly demanding surgical approach regarding technical requirements for the surgeon, who must be trained in order to perform a safe surgical intervention. Traditional surgical education in minimally invasive surgery is commonly based on subjective criteria to quantify and evaluate surgical abilities, which could be potentially unsafe for the patient. Authors, surgeons and associations are increasingly demanding the development of more objective assessment tools that can accredit surgeons as technically competent. This paper describes the state of the art in objective assessment methods of surgical skills. It gives an overview on assessment systems based on structured checklists and rating scales, surgical simulators, and instrument motion analysis. As a future work, an objective and automatic assessment method of surgical skills should be standardized as a means towards proficiency-based curricula for training in laparoscopic surgery and its certification.
Resumo:
The present work covers the first validation efforts of the EVA Tracking System for the assessment of minimally invasive surgery (MIS) psychomotor skills. Instrument movements were recorded for 42 surgeons (4 expert, 22 residents, 16 novice medical students) and analyzed for a box trainer peg transfer task. Construct validation was established for 7/9 motion analysis parameters (MAPs). Concurrent validation was determined for 8/9 MAPs against the TrEndo Tracking System. Finally, automatic determination of surgical proficiency based on the MAPs was sought by 3 different approaches to supervised classification (LDA, SVM, ANFIS), with accuracy results of 61.9%, 83.3% and 80.9% respectively. Results not only reflect on the validation of EVA for skills? assessment, but also on the relevance of motion analysis of instruments in the determination of surgical competence.
Resumo:
This paper presents the AMELIE Authoring Tool for e-health applications. AMELIE provides the means for creating video-based contents with a focus on e-learning and telerehabilitation processes. The main core of AMELIE lies in the efficient exploitation of raw multimedia resources, which may be already available at clinical centers or recorded ad hoc for learning purposes by health professionals. Three real use cases scenarios involving different target users are presented: (1) cognitive skills? training of surgeons in minimally invasive surgery (medical professionals), (2) training of informal carers for elderly home assistance and (3) cognitive rehabilitation of patients with acquired brain injury. Preliminary validation in the field of surgery hints at the potential of AMELIE; and its versatility in different medical applications is patent from the use cases described. Regardless, new validation studies are planned in the three main application areas identified in this work.
Resumo:
Background: Minimally invasive surgery creates two technological opportunities: (1) the development of better training and objective evaluation environments, and (2) the creation of image guided surgical systems.
Resumo:
Auxetic materials (or metamaterials) have negative Poisson ratios (NPR) and display the unexpected properties of lateral expansion when stretched, and equal and opposing densification when compressed. Such auxetic materials are being used more frequently in the development of novel products, especially in the fields of intelligent expandable actuators, shape-morphing structures, and minimally invasive implantable devices. Although several micromanufacturing technologies have already been applied to the development of auxetic materials and devices, additional precision is needed to take full advantage of their special mechanical properties. In this study, we present a very promising approach for the development of auxetic materials and devices based on the use of deep reactive ion etching (DRIE). The process stands out for its precision and its potential applications to mass production. To our knowledge, it represents the first time this technology has been applied to the manufacture of auxetic materials with nanometric details. We take into account the present capabilities and challenges linked to the use of DRIE in the development of auxetic materials and auxetic-based devices.