955 resultados para measurement scale
Resumo:
Polymers have become the reference material for high reliability and performance applications. In this work, a multi-scale approach is proposed to investigate the mechanical properties of polymeric based material under strain. To achieve a better understanding of phenomena occurring at the smaller scales, a coupling of a Finite Element Method (FEM) and Molecular Dynamics (MD) modeling in an iterative procedure was employed, enabling the prediction of the macroscopic constitutive response. As the mechanical response can be related to the local microstructure, which in turn depends on the nano-scale structure, the previous described multi-scale method computes the stress-strain relationship at every analysis point of the macro-structure by detailed modeling of the underlying micro- and meso-scale deformation phenomena. The proposed multi-scale approach can enable prediction of properties at the macroscale while taking into consideration phenomena that occur at the mesoscale, thus offering an increased potential accuracy compared to traditional methods.
Resumo:
A numeric model has been proposed to investigate the mechanical and electrical properties of a polymeric/carbon nanotube (CNT) composite material subjected to a deformation force. The reinforcing phase affects the behavior of the polymeric matrix and depends on the nanofiber aspect ratio and preferential orientation. The simulations show that the mechanical behavior of a computer generated material (CGM) depends on fiber length and initial orientation in the polymeric matrix. It is also shown how the conductivity of the polymer/CNT composite can be calculated for each time step of applied stress, effectively providing the ability to simulate and predict strain-dependent electrical behavior of CNT nanocomposites.
Resumo:
The purpose of this study was to evaluate and establish the mean values of IOP in healthy adult sheep using an applanation tonometer. Information on age, sex, and breed was obtained for all animals included in this study. Twenty five healthy sheep (Ovis aries), of the same breed (Texel), male or female, with three years of age, received an ophthalmic examination in both eyes, including pupillary reflexes, Schirmer tear test, slit lamp biomicroscopy, and fluorescein staining. For all ophthalmic testing, animals were gently physically restrained, with no pressure in the jugular area and the eyelids were carefully open. IOP was measured by applanation tonometry (Tonopen XL). The same examiner performed the tonometry; measurements were taken three times for each eye, and their average was recorded as the IOP of the animal. Statistical analysis was performed using paired t-test and values of P < 0.05 were considered significant. The mean intraocular pressure in the whole group of 50 eyes was of 16.36 +/- 2.19 mm Hg. The mean (SD) IOP in the right eye was of 15.96 +/- 2.02 mm Hg, while the mean (SD) IOP in the left eye was of 16.76 +/- 2.32 mm Hg. Significant differences in IOP were not found between right and left eyes. The applanation tonometer was adequate for measuring the intraocular pressure in sheep. Reference data will assist in diagnosing testing for ophthalmic disease in sheep, as¹ well as promote further studies in this area.
Resumo:
Performance measurement of police services is complicated by ambiguous and complex goal- and objectives-setting, and by the difficulties of measuring outputs. This article looks at the organizational and management changes being made in Portuguese police forces. The authors fill a gap in the literature on performance measurement in Portugal by taking a national approach to the study of how law enforcement agencies are introducing new management accounting changes. The article therefore widens the debate on performance measurement and performance improvements in law enforcement.
Resumo:
Polymeric materials have become the reference material for high reliability and performance applications. However, their performance in service conditions is difficult to predict, due in large part to their inherent complex morphology, which leads to non-linear and anisotropic behavior, highly dependent on the thermomechanical environment under which it is processed. In this work, a multiscale approach is proposed to investigate the mechanical properties of polymeric-based material under strain. To achieve a better understanding of phenomena occurring at the smaller scales, the coupling of a finite element method (FEM) and molecular dynamics (MD) modeling, in an iterative procedure, was employed, enabling the prediction of the macroscopic constitutive response. As the mechanical response can be related to the local microstructure, which in turn depends on the nano-scale structure, this multiscale approach computes the stress-strain relationship at every analysis point of the macro-structure by detailed modeling of the underlying micro- and meso-scale deformation phenomena. The proposed multiscale approach can enable prediction of properties at the macroscale while taking into consideration phenomena that occur at the mesoscale, thus offering an increased potential accuracy compared to traditional methods.
Resumo:
Websites are, nowadays, the face of institutions, but they are often neglected, especially when it comes to contents. In the present paper, we put forth an investigation work whose final goal is the development of a model for the measurement of data quality in institutional websites for health units. To that end, we have carried out a bibliographic review of the available approaches for the evaluation of website content quality, in order to identify the most recurrent dimensions and the attributes, and we are currently carrying out a Delphi Method process, presently in its second stage, with the purpose of reaching an adequate set of attributes for the measurement of content quality.
Resumo:
Many public organisations have been under great pressure in recent years to increase the efficiency and transparency of outputs, to rationalise the use of public resources, and to increase the quality of service delivery. In this context, public organisations were encouraged to introduce the New Public Management reforms with the goal of improving the efficiency and effectiveness of the performance organisation through a new public management model. This new public management model is based on measurement by outputs and outcomes, a clear definition of responsibilities, the transparency and accountability of governmental activities, and on a greater value for citizens. What type of performance measurement systems are used in police services? Based on the literature, we see that multidimensional models, such as the Balanced Scorecard, are important in many public organisations, like municipalities, universities, and hospitals. Police services are characterised by complex, diverse objectives and stakeholders. Therefore, performance measurement of these public services calls for a specific analysis. Based on a nationwide survey of all police chiefs of the Portuguese police force, we find that employee performance measurement is the main form of measurement. Also, we propose a strategic map for the Portuguese police service.
Resumo:
This paper examines the nature of the construct of consumers' trust toward the electronic channel of their financial institution. Through a study of a total of 372 individual users of Internet banking in Spain, we have managed to develop a third-order measuring instrument that integrates a total of seven dimensions. The exploratory and confirmatory factor analyses were used to test the validation and reliability of the proposed scale. Findings provide useful information to professionals who seek to identify how customer's trust is formed in the online channel and in the financial sector.
Resumo:
In order to obtain evidence on the size of the impact of the Hong Kong/68 variant of influenza A2 virus on the population of São Paulo, Brazil, serum samples taken in 1967 before this variant appeared and during successive years after it appeared were examined for their antibody content. Haemagglutination-inhibition tests performed on a total of 2726 serum samples from adults showed a sharp decrease in 1969 of the proportion of sera without antibody to the Hong Kong/68 variant and a corresponding mercase in the proportion with high titres. It was concluded that about three-quarters of the adult population became infected at some time after the variant appeared, the majority in the first year of prevalence.
Resumo:
Introdução: A Motor Assessment Scale (MAS) tem mostrado ser um instrumento válido e fidedigno na avaliação do progresso clínico de indivíduos que sofreram um Acidente Vascular Cerebral (AVC). Objectivos: Traduzir e adaptar a MAS à realidade portuguesa e contribuir para a validação da versão portuguesa, avaliando a sua consistência interna. Metodologia: Após um processo de tradução, revisão por peritos, retroversão e comparação com a versão original, obteve-se a versão portuguesa da MAS. Procedeu-se a um estudo correlacional transversal para avaliação da consistência interna; a amostra final incluiu 30 sujeitos, 16 do sexo masculino e 14 do sexo feminino, com idades entre os 42 e 85 anos (média de 64±11,85 anos), com hemiparésia ou hemiplegia decorrente de AVC e que realizavam fisioterapia em um de 6 Hospitais seleccionados por conveniência; a média do tempo de diagnóstico foi de 306±1322,82 dias e do tempo de fisioterapia foi de 47±57,57 dias. Resultados: Obteve-se uma média de 24±14,51 pontos nas pontuações totais e um coeficiente de Alfa de Cronbach de 0,939, sem a exclusão de qualquer item; as correlações inter item variaram entre 0,395 e 0,916. Conclusões: Apesar da reduzida amostra e da sua heterogeneidade nas características e pontuações da escala, a Versão Portuguesa da MAS apresentou uma forte consistência interna, verificando-se que os itens estão, na sua maioria, muito correlacionados entre si, o que sustenta a adequação de cada item e apoia que, de forma geral, esta escala tem uma concepção lógica e estruturada.
Resumo:
INTRODUCTION: Among psychiatric disorders schizophrenia is often said to be the condition with the most disputed definition.The Bleulerian and Schneiderian approaches have given rise to diagnostic formulations that have varied with time and place. Controversies over the concept of schizophrenia were examined within European/North American settings in the early 1970s but little has since been reported on the views of psychiatrists in developing countries. In Brazil both concepts are referred to in the literature. A scale was developed to measure adherence to Bleulerian and Schneiderian concepts among psychiatrists working in S. Paulo. METHODOLOGY: A self-reported questionnaire comprising seventeen visual analogue-scale statements related to Bleulerian and Schneiderian definitions of Shizophrenia, plus sociodemographic and training characteristics, was distributed to a non-randomised sample of 150 psychiatrists. The two sub-scales were assessed by psychometric methods for internal consistency, sub-scale structure and test-retest reliability. Items selected according to internal consistency were examined by a two-factor model exploratory factor analysis. Intraclass correlation coefficients described the stability of the scale. RESULTS: Replies were received from 117 psychiatrists (mean age 36 (SD 7.9)), 74% of whom were made and 26% female. The Schneiderian scale showed better overall internal consistency than the Bleulerian scale. Intra-class correlation coefficients for test-retest comparisons were between 0.5 and 0.7 for Schneiderian items and 0.2 and 0.7 for Bleulerian items. There was no negative association between Bleulerian and Schneiderian scale scores, suggesting that respondents may hold both concepts. Place of training was significantly associated with the respondent's opinion; disagreement with a Bleulerian standpoint predominated for those trained at the University of S. Paulo. CONCLUSIONS: The less satisfactory reliability for the Bleulerian sub-scale limits confidence in the whole scale but on the other hand this questionnaire contributes to the understanding of the controversy over Bleulerian and Schneiderian models for conceptualisation of schizophrenia, the former requiring more inference and therefore being prone to unreliability.
Resumo:
Introdução: O acidente vascular encefálico (AVE) é uma importante e frequente condição de saúde que se repercute na funcionalidade do indivíduo. No sentido de reabilitar a função perdida, é comum o recurso a intervenções de fisioterapia baseado o conceito de Bobath. Como tal, importa verificar, as modificações no âmbito do controlo postural, através da migração do centro de pressão na base de suporte, face à aplicação de uma intervenção segundo abordagem baseada no conceito de Bobath em dois indivíduos com AVE. Métodos e participantes: Foram recrutados dois indivíduos com diagnóstico de AVE num hospital da zona do grande Porto. Dados referentes ao equilíbrio estático na condição de medição “olhos abertos ou fechados” e “calçado ou descalço” foram obtidos através de plataforma de forças, antes e após uma intervenção baseado no conceito de Bobath durante 13 semanas (M0 e M1). Nestes dois momentos foram ainda avaliados a mobilidade, função cognitiva, participação, equilíbrio através do teste Timed Up & Go (TUG) e Timed Up & Go Modificado (TUGM), e das escalas Mini Mental State Examination (MMSE), Postural Assessment for Stroke Scale (PASS), Escala de Berg (EB) e Índice de Barthel Modificado (IBM). Resultados: Os participantes obtiveram em ambos os momentos pontuação máxima no MMSE. Ambos os indivíduos atingiram o valor máximo no IBM em M1 (Mo: A: 78; B: 65). Ambos os indivíduos aumentaram o score entre M0 e M1, relativamente ao PASS (A: M0:21; M1:33; B: M0: 26; M1:34) e EB (A: M0:48; M1:54; B: M0: 30; M1:50). O tempo de realização do TUG e do TUGM diminuíram entre momentos em ambos os indivíduos (respectivamente: A: 15''13'' a 13''27''; B: 24''13'' a 13''88'' e A: 19''08''' a 13''27''; B: 29''60''' a 17''64'''). A área de deslocação do centro de pressão (CP) variou entre momentos em todas as condições de avaliação, sendo menor na condição “olhos abertos e descalço” em ambos os participantes (“olhos abertos e calçado”: A: M0= 1,364, M1=2,796; B: M0=1,892, M1=2,979; “olhos abertos e descalço”: A: M0= 0,758, M1=0,727; B: M0=3,064, M1=1,952; “olhos fechados e calçado”: A: M0= 2,360, M1=2,998; B: M0=2,232, M1= 4,392; “olhos fechados e descalço”: A: M0= 1,347, M1=2,388; B: M0=1,652, M1= 1,016). O desvio padrão das deslocações anteroposteriores variou entre momentos, sendo tendencialmente maior em M1 e na condição “descalço e olhos abertos”(“olhos abertos e calçado”: A: M0= 0,201, M1=0,500; B: M0=0,252, M1=0,310; “olhos abertos e descalço”: A: M0= 0,118, M1=0,165; B: M0=0,282, M1=0,276; “olhos fechados e calçado”: A: M0= 0,308, M1=0,398; B: M0=0,274, M1= 0,471; “olhos fechados e descalço”: A: M0= 0,158 , M1=0,373; B: M0=0,230, M1= 0,172), o desvio padrão das deslocações médio-lateral seguem a mesma tendência (“olhos abertos e calçado”: A: M0= 0,370 , M1=0,473; B: M0=0,454, M1=0,517; “olhos abertos e descalço”: A: M0= 0,354, M1=0,236 ; B: M0=0,584, M1=0,381; “olhos fechados e calçado”: A: M0= 0,425, M1=0,463; B: M0=0,462, M1= 0,583; “olhos fechados e descalço”: A: M0= 0,475, M1=0,416; B: M0=0,389, M1= 0,342). A velocidade de oscilação na direcção antero – posterior variou entre momentos, sendo tendencialmente menor em M1, em ambos os participantes e em todas as condições de avaliação: “olhos abertos e calçado”: A: M0= 0,886 , M1=0,532; B: M0=2,507, M1=01,072; “olhos abertos e descalço”: A: M0= 2,562, M1=3,815 ; B: M0=4,367, M1=0,262; “olhos fechados e calçado”: A: M0= 2,689, M1=1,757; B: M0=2,821, M1= 0,769; “olhos fechados e descalço”: A: M0= 2,984, M1=2,525; B: M0=4,100, M1= 0,265), a velocidade de oscilação na direcção médio – lateral seguem a mesma tendência para as condições de “olhos abertos e calçado”: A: M0= 6,524 , M1=6,218; B: M0=0,467, M1=0,404; “olhos fechados e calçado”: A: M0= 6,387, M1=1,927; B: M0=0,351, M1= 0,505; mas a velocidade de oscilação aumenta para as condições de “olhos abertos e descalço”: A: M0= 3,108, M1=7,806 ; B: M0=1,150, M1=8,054; “olhos fechados e descalço”: A: M0= 3,444, M1=3,839; B: M0=1,434, M1= 7,891). Conclusão: Entre os dois momentos os indivíduos melhoraram a sua mobilidade, equilíbrio, participação e actividades, potencialmente devido à intervenção baseado no conceito de Bobath.
Resumo:
As sequelas fisiopatológicas do stress oxidativo são difíceis de quantificar. Apesar dos obstáculos, a relevância médica do stress oxidativo tem vindo a ser cada vez mais reconhecida, sendo hoje em dia encarado como um componente chave de virtualmente todas as doenças. A disfunção erétil (DE) surge neste contexto como uma espécie de barómetro da função endotelial e do dano oxidativo. A quantificação de biomarcadores de stress oxidativo poderá apresentar um enorme impacto na avaliação de pacientes com DE. O rácio glutationa reduzida/oxidada (GSH/GSSG) e a nitrotirosina (3-NT) têm vindo a demonstrar relevância clínica. A consideração de polimorfismos genéticos constitui ainda uma abordagem promissora na avaliação destas relações no futuro. Um método altamente sensível de cromatografia líquida de alta performance (HPLC) foi desenvolvido para a determinação de 3-NT em plasma humano. As concentrações de 3-NT medidos em indivíduos com DE foram 6,6±2,1μM (média±S.D., n = 46). A medição da concentração plasmática de 3-NT poderá revelar-se útil como marcador de dano oxidativo dependente do óxido nítrico (NO). O nível de stress oxidativo pode também ser quantificado através da medição do decréscimo do rácio GSH/GSSG, que tem mostrado alterações numa miríade de patologias, como a DE e a diabetes mellitus. O método proposto para a quantificação do rácio GSH/GSSG em HPLC apresenta a vantagem de avaliação concomitante dos dois parâmetros em apenas uma corrida. O valor do rácio GSH/GSSG obtido a partir de sangue de indivíduos com DE foi 11,9±9,8 (média±S.D., n = 49). Os resultados estatísticos revelaram diferenças significativas (p<0,001) entre ambos a concentração plasmática de 3-NT e o rácio GSH/GSSG de sangue de indivíduos com DE e as respetivas medições em indivíduos saudáveis. Observaram-se ainda diferenças estatisticamente significativas (p≈0,027) entre o rácio GSH/GSSG do sangue de pacientes apenas com diagnóstico de DE e a medição respetiva em indivíduos com DE e comorbilidades cardiovasculares. Estes resultados enfatizam o papel do dano oxidativo na biopatologia da DE, elucidado com o auxílio destas duas metodologias, que poderão ter um amplo campo de aplicação no futuro, dado que se mostraram simples, não dispendiosas e rápidas, podendo eventualmente adequar-se a estudos de rastreio em larga escala.