739 resultados para eye lens
Resumo:
This thesis reports on research done for the integration of eye tracking technology into virtual reality environments, with the goal of using it in rehabilitation of patients who suffered from stroke. For the last few years, eye tracking has been a focus on medical research, used as an assistive tool to help people with disabilities interact with new technologies and as an assessment tool to track the eye gaze during computer interactions. However, tracking more complex gaze behaviors and relating them to motor deficits in people with disabilities is an area that has not been fully explored, therefore it became the focal point of this research. During the research, two exploratory studies were performed in which eye tracking technology was integrated in the context of a newly created virtual reality task to assess the impact of stroke. Using an eye tracking device and a custom virtual task, the system developed is able to monitor the eye gaze pattern changes over time in patients with stroke, as well as allowing their eye gaze to function as an input for the task. Based on neuroscientific hypotheses of upper limb motor control, the studies aimed at verifying the differences in gaze patterns during the observation and execution of the virtual goal-oriented task in stroke patients (N=10), and also to assess normal gaze behavior in healthy participants (N=20). Results were found consistent and supported the hypotheses formulated, showing that eye gaze could be used as a valid assessment tool on these patients. However, the findings of this first exploratory approach are limited in order to fully understand the effect of stroke on eye gaze behavior. Therefore, a novel model-driven paradigm is proposed to further understand the relation between the neuronal mechanisms underlying goal-oriented actions and eye gaze behavior.
Resumo:
Objective: To determine the prevalence of ocular findings of the external structures and anterior segment of the eye, detected by biomicroscopic examination in schoolchildren in Natal (RN) - Brazil. Methods: After previous random selection, 1,024 pupils from elementary and secondary public and private schools in the city of Natal were evaluated from March to June 2001. All were submitted to preestablished standard research norms, consisting of identification, demographic information, ophthalmologic biomicroscopic examination, with slit lamp, performed by ophthalmologists from the “Onofre Lopes” University Hospital. Results: Alterations of the conjunctival and palpebral conditions were the most prevalent (10.4% and 6.2% respectively). Follicles (4.2%) and papillae (3.0%) were the frequent conjunctival lesions, while blepharitis (3.5%) and meibomitis (1.1%) were the most detected abnormalities in the eyelids. Upon examining the cornea, iris, lens and anterior vitreous, the most encountered findings were nubecula (0.5%), papillary membrane reliquiae (0.5%), posterior capsula opacity (0.8%) and hyaloid arteria reliquiae (2.0%). Conclusion: The most prevalent findings affecting the external structures of the eye such as eyelids and conjunctiva, consisted of blepharitis followed by follicular reaction of the conjunctiva. The most prevalent abnormalities in the cornea, iris, lens and anterior vitreous were nubecula, papillary membrane reliquiae, posterior capsular opacity and hyaloid arteria reliquiae, in that order
Resumo:
Importance of the field: The use of topical agents poses unique and challenging hurdles for drug delivery. Topical steroids effectively control ocular inflammation, but are associated with the well-recognized dilemma of patient compliance. Although administration of topical antimicrobials as prophylaxis is acceptable among ophthalmologists, this common practice has no sound evidence base Developing a new antimicrobial agent or delivery strategy with enhanced penetration by considering the anatomical and physiological constraints exerted by the barriers of the eye is not a commonly perceived strategy. Exploiting the permeability of the sclera, subconjunctival routes may offer a promising alternative for enhanced drug delivery and tissue targeting.Area covered in this review: Ocular drug delivery strategies were reviewed for ocular inflammation and infections clinically adopted for newer class of antimicrobials, which use a multipronged approach to limit risks of endophthalmitis.What the reader will gain: The analysis substantiates a new transscleral drug delivery therapeutic approach for cataract surgery.Take home message: A new anti-inflammatory and anti-infective paradigm that frees the patient from the nuisance of topical therapeutics is introduced, opening a large investigative avenue for future improved therapies.
Resumo:
This article aims to analyse the introduction of environmental issues in the context of the production function, which has been referred to as the organisational area to lead corporate environmental management. With that purpose, the theoretical references for corporate environmental management and the necessary alterations in production function have been organised to include environmental aspects, especially in terms of product and process development, quality management, and logistics. Considering that this research field still lacks empirical evidence for Brazilian companies, four case studies were conducted using companies located in the country. The environmental management maturity level of those companies tends to follow the rate with which the environmental issue is introduced in production sub-areas, especially in the product development process. However, in most cases we found that the companies had difficulties in structuring the insertion of the environmental dimension in logistics. The final notes point out the distance observed between what is recommended by international literature and the reality of Brazilian companies in the challenge of making the production function environmentally friendly.
Resumo:
The visual system is an important link between the animal and the environment, com profound influences on the habits and lifestyle in various habitats. Adaptive mechanismsto the temporal niche are present in the visual system of many vertebrates, involving changins in ocular dimensios and design, retinal cell distribution and organization of neurochemical circuits related to the retinal resolution or sensitivity. The sensory system of the eye is represented by the retina, whose organization is responsible by receipty, initial analysis, and transmission of the information to the brain. The knowledge of the position of the eyes in the head and the distribution of retinal cells allow to identify adaptive aspects of each species to its visual field, which is characteristic to the ecological niche it occupies. In this research, we study eye anatomical characteristics and retina neurochemical features of the rock cavy (Kerodon rupestris), a tipical Brazilian rodent from the suborder Hystricomorpha, family Caviidae. The rock cavy has lateral eyes well constitute bony orbit and well differentiated extrinsic muscle. The study of the descriptive and morphometric anatomy of the showed mean values of axial diameter 10.7±0,5mm and equatorial diameter 11.6±0.7mm. The pupil is slit shaped and the lens has mean axial diameter 5.4±0.03 mm, corresponding to ~45% of the axial diameter of the eye. The posterior nodal distance and the retinal magnification factor were estimated at 6.74 mm e 118 μm/grau, respectively. Flat mounts were processed for Nissl stain, and the topographic distribution of ganglion cells showed a moderate visual band, just below the optic disc, with higher density in the ventral retina. Retinal vertical sections and flat mounts were processed for immunohistochemistry to visualize tyrosine hydroxilase (TH) and thus two types of TH+ cells were detected. Type 1 cells had strong TH-immunoreactivity, the body cell varied from 120.047 to 269.373 μm2 stratifying in the sublamina 1 of the IPL. Type 2 cells were weakly TH-imunoreactive, had cell body located mostly in the IPL, varying from 54.848 to 177.142 μm2, constituting ~10% of the TH+ cells. Both cell types exhibited similar topographic distribution with higher density found in a horizontal band along of the naso-temporal axis in the dorsal retina. The total population of dopaminergic cells was 2,156±469,4 cells, occupying an average area of 198,164 μm2. The presence of cones and rods was detected by immunohistochemistry in vertical sections and flat mounts. S cones density is around 10 times smaller than L cones, with different degree of spatial organization. Other retinal neuronal populations of the rock cavy were also detected in vertical sections with specific markers. Comparative analysis of the anatomical characteristics of the rock cavy eye 12 suggest that it was designed to acquire higher sensitivity to light, at expense of image sharpness, compatible with a vision at mesopic conditions. Additionally, the distribution of the 2 subtypes of dopaminergic cells in a naso-temporal band in the dorsal retina seems suitable to a gain in sensitivity, coherent with an animal with predominantly crepuscular activity pattern
Resumo:
Purpose: To investigate the dynamics of ocular eyelid movements in newborn infants and preschool-age children.Methods: Fifty newborn infants and 200 preschool children aged 4-6 years were examined. Images of each child, with his or her eyes in the primary eye position looking at an object placed at the child's height, were recorded with a digital videocamera for 3 mins. Complete and incomplete blink rates, opening, closing and complete blink times were calculated.Results: Newborn infants presented a lower number of incomplete movements than preschool children. The complete blink rate was lower in newborn infants (6.2 blinks/min) than in preschool children (8.0 blinks/minute). Eyelid closing, opening and compete blink times were longer in newborn infants than in preschool children at all observation times.Conclusions: Newborn infants had a different pattern of eyelid movement compared with preschool children. Specific characteristics that are found in this group of children particularly, such as immaturity of the neural system and more resistant tear film, may explain these findings in part.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
A catarata, especialmente na espécie canina, é uma doença oftálmica importante. Seu tratamento é eminentemente cirúrgico, mas a perda do cristalino resulta em alta hipermetropia, e a visão fica comprometida. A correção pode ser feita com a utilização de lente intra-ocular (LIO). Este estudo teve por objetivo colher dados que pudessem fornecer subsídios métricos para a produção de LIOs a serem aplicadas em cães facectomizados, visando a restauração de visão adequada nos animais acometidos por catarata. Foram selecionados 120 cães de ambos os sexos, sadios ao exame clínico e sem evidência de doença ocular ao exame oftálmico de rotina. Foram realizados estudos ceratométrico e biométrico, pela ultra-sonografia modo-A. Uma fórmula específica foi utilizada para a determinação do poder dióptrico de uma LIO utilizada para substituir o cristalino extraído. O poder dióptrico da LIO foi correlacionado com o peso e o sexo dos animais, e entre os olhos direito e esquerdo. Baseado nestas correlações, concluiu-se que o poder dióptrico adequado para uma LIO a ser implantada em um cão facectomizado é influenciado principalmente pelo peso do animal, apesar de apresentar discretas diferenças quando comparado entre os olhos direito e esquerdo e entre machos e fêmeas.
Resumo:
OBJETIVO: Avaliar as causas de baixa visão e cegueira em indivíduos facectomizados, de amostra da população de cidades da região centrooeste do estado de São Paulo. Métodos: Estudo transversal, observacional, feito em cinco cidades da região centro-oeste do estado de São Paulo, em amostra domiciliar e baseada nos dados do último Censo Demográfico (IBGE, 1995), com escolha sistemática dos domicílios. Foi considerada para o presente estudo uma subamostra de indivíduos facectomizados, dos quais foram obtidos dados de identificação e exame oftalmológico completo. Os dados foram avaliados por estatísticas descritivas, análise de freqüência de ocorrência e proporção de concordância, com intervalo de confiança de 95%. RESULTADOS: Dos indivíduos amostrados, 2,37% haviam sido submetidos à facectomia. Dos 201 olhos operados, 26,9% apresentavam acuidade visual compatível com cegueira ou deficiência visual. Com a melhor correção óptica, a acuidade visual permaneceu <0,3 em 19,0%. O exame refracional proporcionou melhora da acuidade visual para 27,9% dos indivíduos facectomizados. As causas de baixa visão foram os erros refrativos não corrigidos, opacidade de cápsula posterior (19,4%), ceratopatia bolhosa (8,3%) coriorretinite cicatricial (8,3%), afacia (8,3%), degeneração macular relacionada a idade (5,5%), leucoma (5,5%), glaucoma (5,5%), atrofia de papila (5,5,%), descolamento de retina (2,8%), atrofia de epitelio pigmentado da retina (2,8%) e alta miopia (2,8%). CONCLUSÃO: Apesar da catarata ser causa de cegueira que pode ser evitável, mesmo após a correção cirúrgica porcentagem expressiva de indivíduos permanece com baixa visão, em geral, em decorrência de fatores relacionados ao seguimento pós-operatório negligenciado.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
OBJETIVO: A catarata é a principal causa tratável de cegueira e deficiência visual em países subdesenvolvidos. Este estudo foi realizado para avaliar se a catarata continua sendo uma importante causa de cegueira no centro-oeste do Estado de São Paulo. MÉTODOS: Um estudo transversal, de caráter observacional, realizado em cinco cidades da região centro-oeste do Estado de São Paulo, para as quais o centro de referência é a cidade de Botucatu. A amostra estabelecida para este estudo, de forma aleatória, seria composta por 5.555 indivíduos, sendo que foram examinados 4.229 indivíduos (8.458 olhos), ou seja, 78% da amostra pretendida. Os indivíduos foram submetidos a um exame oftalmológico completo que consistia em avaliação da acuidade visual (com e sem correção), tonometria, biomicroscopia, fundoscopia e exame refracional. O diagnóstico de catarata foi dado aos indivíduos que apresentassem opacidade de cristalino na biomicroscopia, de acordo com o Sistema de Classificação de Opacidade do Cristalino II (LOCS II). Olhos apresentando deficiência visual ou cegueira, com a melhor correção e causados por catarata, foram considerados após excluir outras patologias que pudessem causar baixa da acuidade visual (AV). Olhos com deficiência visual foram considerados quando 0,05 < AV < 0,3 e olhos cegos quando AV < 0,05. Indivíduos com deficiência visual foram considerados quando 0,05 < AV < 0,3 e indivíduos cegos quando AV < 0,3, no melhor olho com a melhor correção. Foi considerado o número de olhos com catarata, o número de olhos com deficiência visual e cegueira e o número de indivíduos com deficiência visual e cegueira. RESULTADOS: A prevalência de catarata na população estudada foi de 4,94% (209 indivíduos), afetando principalmente indivíduos com mais de 50 anos (92,34%) e do sexo feminino (61,11%). A catarata foi a causa de deficiência visual para 0,96% e a causa de cegueira para 0,52% de toda a população estudada. CONCLUSÃO: Nossos resultados mostraram que a prevalência de catarata na população estudada é semelhante aos índices de países desenvolvidos.