998 resultados para district heat
Resumo:
Sap flow could be used as physiological parameter to assist irrigation of screen house citrus nursery trees by continuous water consumption estimation. Herein we report a first set of results indicating the potential use of the heat dissipation method for sap flow measurement in containerized citrus nursery trees. 'Valencia' sweet orange [Citrus sinensis (L.) Osbeck] budded on 'Rangpur' lime (Citrus limonia Osbeck) was evaluated for 30 days during summer. Heat dissipation probes and thermocouple sensors were constructed with low-cost and easily available materials in order to improve accessibility of the method. Sap flow showed high correlation to air temperature inside the screen house. However, errors due to natural thermal gradient and plant tissue injuries affected measurement precision. Transpiration estimated by sap flow measurement was four times higher than gravimetric measurement. Improved micro-probes, adequate method calibration, and non-toxic insulating materials should be further investigated.
Resumo:
The effect of the heat flux on the rate of chemical reaction in dilute gases is shown to be important for reactions characterized by high activation energies and in the presence of very large temperature gradients. This effect, obtained from the second-order terms in the distribution function (similar to those obtained in the Burnett approximation to the solution of the Boltzmann equation), is derived on the basis of information theory. It is shown that the analytical results describing the effect are simpler if the kinetic definition for the nonequilibrium temperature is introduced than if the thermodynamic definition is introduced. The numerical results are nearly the same for both definitions
Resumo:
Kaukolämpöverkoston lämpötilatason alentaminen kasvattaa sähkösaalista sähkön ja lämmön yhteistuotannossa, pienentää kaukolämpöverkon lämpöhäviöitä ja lisäksi hyvä jäähdytys tuo säästöjä kaukolämpöveden pumppausenergian kulutuksessa. Työssä selvitettiin laskennallisesti kaukolämpöveden lämpötilojen alentamisen vaikutuksia ja niiden tuomia säästöjä Kuopion Energian kaukolämpöjärjestelmässä. Tulokseksi saatiin, että laskemalla paluulämpötilaa yhdellä asteella nousee vuotuinen sähköntuotanto 0,1 %, pienenevät lämpöhäviöt 0,88 % ja pumppausenergian kulutus 7,7 %. Menolämpötilaa laskemalla vaikutukseksi saatiin 0,4 % lisää sähköä ja 0,79 % pienemmät lämpöhäviöt. Työssä käytetyillä sähkön hinnalla 92 mk/MWh ja lämmön hinnalla 61 mk/MWh saatiin tulokseksi, että alentamalla paluulämpötilaa asteella on kokonaishyöty noin 68 700 mk vuodessa ja menolämpötilaa alentamalla 71 500 mk. Asiakkaiden lämmönjakojärjestelmät aikaansaavat jäähdytyksen. Ongelmana on, etteivät nykyiset yleisesti käytössä olevat kaukolämpötariffit ohjaa asiakkaita riittävästi hyvään jäähdytykseen. Asiakkaan jäähdytysmotivaation parantamiseksi tulisi kehittää tariffijärjestelmä, joka selkeästi palkitsisi hyvästä jäähdytyksestä. Työssä selvitettiin asiakaskyselyllä asiakkaiden näkemyksiä nykyisestä kaukolämpötariffista ja mielenkiintoa uusiin tariffivaihtoehtoihin. Kyselyn perustella asiakkaat olisivat motivoituneita jäähdytyksen parantamiseen, jos lämmityskustannusten alennus olisi vähintään 10 %. Meno- ja paluulämpötilan alentamisen taloudellisia hyötyjä asiakasta kohti selvitettiin esimerkkitapauksella. Vertaamalla asiakkaan aikaansaamia taloudellisia hyötyjä hänen lämmityskustannuksiinsa, selvitettiin kuinka suuri alennusprosentti jäähdytyksestä palkitsevassa tariffissa voitaisiin tarjota. Työssä käytetyillä energian hinnoilla ja lämpötilojen alentamistapauksilla asiakkaalle voitaisiin tarjota jäähdytyksestä palkitsevassa tariffissa 1-2 % alennus lämmityskustannuksista.
Resumo:
Diplomityössä selvitetään Hämeenlinnan Energian kaukolämpö- ja maakaasuverkoston suunnitteluun ja kunnossapitoon liittyvien tietojärjestelmien kehitysmahdollisuuksia. Käydään läpi olemassa olevat järjestelmät ja todetaan olevan tarpeen uudistaa verkostolaskenta- ja kunnossapito-ohjelmia. Mahdolliseksi uudeksi verkostolaskentaohjelmaksi rajataan Komartekin Flowra 32 tai Process Visionin lämpö Nexus. Kunnossapidon osalta Komartekin Lämpökunto tai Kunnondatan Visual Maint. Tehtyjen ohjelmavertailujen jälkeen työssä esitetään Hämeenlinnan Energian uudeksi verkostolaskentaohjelmaksi lämpö Nexus ja kunnossapito-ohjelmaksi Visual Maint. Ohjelmahankinnoille esitetään käyttöönottosuunnitelmat. Olemassa olevien tietojärjestelmien osalta esitetään vaihtoehtoja, joilla voidaan lisätä ohjelmista saatavaa hyötyä.
Resumo:
BACKGROUND: Plasmodium and soil transmitted helminth infections (STH) are a major public health problem, particularly among children. There are conflicting findings on potential association between these two parasites. This study investigated the Plasmodium and helminth co-infections among children aged 2 months to 9 years living in Bagamoyo district, coastal region of Tanzania. METHODS: A community-based cross-sectional survey was conducted among 1033 children. Stool, urine and blood samples were examined using a broad set of quality controlled diagnostic methods for common STH (Ascaris lumbricoides, hookworm, Strongyloides stercoralis, Enterobius vermicularis, Trichuris trichura), schistosoma species and Wuchereria bancrofti. Blood slides and malaria rapid diagnostic tests (mRDTs) were utilized for Plasmodium diagnosis. RESULTS: Out of 992 children analyzed, the prevalence of Plasmodium infection was 13% (130/992), helminth 28.5% (283/992); 5% (50/992) had co-infection with Plasmodium and helminth. The prevalence rate of Plasmodium, specific STH and co-infections increased significantly with age (p < 0.001), with older children mostly affected except for S. stercoralis monoinfection and co-infections. Spatial variations of co-infection prevalence were observed between and within villages. There was a trend for STH infections to be associated with Plasmodium infection [OR adjusted for age group 1.4, 95% CI (1.0-2.1)], which was more marked for S. stercoralis (OR = 2.2, 95% CI (1.1-4.3). Age and not schooling were risk factors for Plasmodium and STH co-infection. CONCLUSION: The findings suggest that STH and Plasmodium infections tend to occur in the same children, with increasing prevalence of co-infection with age. This calls for an integrated approach such as using mass chemotherapy with dual effect (e.g., ivermectin) coupled with improved housing, sanitation and hygiene for the control of both parasitic infections.
Resumo:
Diplomityön tavoitteena on tuottaa informaatiota kunnalliseen päätöksentekoon, jonka avulla kestävän kehityksen näkökulmia voidaan huomioida kunnan energiaratkaisusta päätettäessä. Yhtenä työn lähtökohtana on ollut myös uusi EU-direktiivi, jonka mukaan ympäristönäkökohtia voidaan huomioida julkisten hankintojen tarjouspyyntömenettelyssä valintaperusteena. Tarkastelun kohteena oli kokoluokaltaan 0,5–3 MW:n aluelämpölaitokset sekä polttoaineiden tuotantoketjut. Työssä vertailtavat polttoaineet olivat metsähake, raskas polttoöljy, kevyt polttoöljy ja turve. Diplomityössä on perehdytty kestävän kehityksen käsitteeseen ja muodostettu sen mukaan ekologiselle, sosiaaliselle ja taloudelliselle näkökulmalle kunnallisen energiaratkaisun indikaattoreita. Empiirisessä osassa käsitellään kestävän kehityksen näkökulmien muodostumista Enon energiaosuuskunnan toimintaan perustuen. Käytettävät kestävän kehityksen näkökulmien mukaiset indikaattorit ovat polttoaineen tuotannosta ja käytöstä aiheutuvat kasvihuonekaasupäästöt, polttoaineen tuotannon työllisyysvaikutukset sekä energian hinnan muodostuminen osuuskunnan asiakkaille. Tässä diplomityössä tarkastelluilla kestävän kehityksen indikaattoreilla mitattuna, metsähakkeen käytöllä energiantuotannossa on positiivinen vaikutus niin kunnan kasvihuonekaasutaseessa, työllisyystilanteessa sekä myös enemmän kuluttajaystävällinen asema, lämmön hinnan vakauden ansiosta, kuin muilla työssä käsiteltävillä polttoaineilla. Polttoaineen tuotantoketjun osalta metsähakkeelle saatiin tuotannon ja käytön aiheuttamaksi kasvihuonekaasupäästöksi 2,9–4,2 g CO2-ekv/MJ. Tulos perustuu Enon energiaosuuskunnan polttoaineen hankinnassa käytössä oleviin keskimääräisiin etäisyyksiin metsäkuljetuksessa (250 m) ja kaukokuljetuksessa (15 km). Tuotannon ja käytön aiheuttamat kasvihuonekaasupäästöt olivat raskaalla polttoöljyllä 88,2 g CO2-ekv/MJ, kevyellä polttoöljyllä 85,0 g CO2-ekv/MJ ja turpeella 104,0–108,1 g CO2-ekv/MJ. Metsähakkeen osalta polttoaineen tuotannon osuus koko tarkastellun energiaketjun kasvihuonekaasupäästöistä oli noin 43–57 %. Enon energiaosuuskunnan tapauksessa vuoden 2005 odotetulla toiminta-asteella metsähakkeella tuotetun lämmön tuotantoketjun kasvihuonekaasupäästöt ovat noin 160 t CO2-ekv. Kevyellä polttoöljyllä tuotetun lämmön tuotantoketjun kasvihuonekaasupäästöt olisivat noin 3700 t CO2-ekv sekä turpeen (50 %) ja metsähakkeen (50 %) seoskäyttöön perustuvalla ketjulla noin 2300–2400 t CO2-ekv. Samaisella toiminta-asteella työllisyysvaikutukset ovat käytettäessä metsähaketta 2,2–8,6 htv, raakaöljyä 0,12 htv ja turvetta 1,4–1,6 htv. Metsähakkeen käyttö aluelämpölaitosten pääpolttoaineena takaa myös vakaan hintakehityksen osuuskunnan asiakkaille.
Resumo:
Tämän työn tavoitteena on löytää suositeltavat mitoitusarvot Liljendalin kunnan kaukolämpöjärjestelmään. Kirjallisuuden perusteella tarkastellaan kaukolämpö-järjestelmän suunnittelua ja mitoitusta sekä lämmön hinnoittelua ja niistä annettuja määräyksiä, suosituksia ja ohjeita. Työssä käsitellään mahdollisuuksia ja keinoja kaukolämmityksen siirtolämpötilojen pienentämiseen. Lisäksi vertaillaan nykyarvomenetelmällä laskemalla kaukolämpöjärjestelmän siirtokustannuksia eri mitoituslämpötiloilla, putkikoolla ja eristyspaksuuksilla. Lämmön myyntihinnalle on tehty tariffiehdotus. Lopuksi on esitetty lämpökeskuksen hankintaa koskevia tietoja. Laskennan tuloksena havaittiin, että siirtolämpötilojen, putkikoon ja eristyspaksuuden oikealla valinnalla voidaan säästää lämmönsiirron kustannuksissa. Laskelmien perusteella suositellaan Liljendalin kunnan kaukolämpöjärjestelmän mitoituslämpötiloiksi 100/50°C ja eristyspaksuudeksi III-luokan eriste. Putkikoon oikealla valinnalla voidaan säästää merkittävästi varsinkin, kun kyseessä on lyhyt siirtoetäisyys. Putkikoon valinnassa on kuitenkin huomioitava mahdolliset tulevaisuuden laajennukset verkossa ja kulutuksen kasvu.
Resumo:
Tutkimuksen tarkoituksena on selvittää sivuainevirtojen paikallisen energiahyötykäytön kannattavuutta ja liiketoimintamahdollisuuksia. Sivuainevirtojen energiahyötykäytöllä tarkoitetaan jäteperäisen polttoaineen käyttöä energiantuotannossa. Tässä tutkimuksessa on keskitytty erilliskerätystä energiajätteestä valmistetun kierrätyspolttoaineen (REF) käyttöön hajautetuissa pienen kokoluokan lämmöntuotantolaitoksissa, tarkasteltava laitoskoko on alle 10 MW. Tällä hetkellä uhkakuvana on, että muuttavan lainsäädännön seurauksena jätteiden energiahyötykäytön kustannukset kohoavat tulevaisuudessa ja näin ollen toiminta pienissä laitoksissa voi muuttua taloudellisesti kannattamattomaksi. Työssä on selvitetty kahden toimivan case-tapauksen avulla paikallisen jätteiden energiahyötykäytön kustannusrakennetta sekä toiminnan jatkomahdollisuuksia uudistuvan lainsäädännön velvoitteet täyttäen. Virtain kaupungin tapauksessa selvitetään paikallisen kaukolämpölaitoksen mahdollisuuksia jatkaa REFin käyttöä turpeen ohella rinnakkaispolttotilanteessa. Etelä-Karjalan tapauksessa paikallisen sivuainevirtojen energiahyötykäytön kannattavuutta selvitetään uuden laitosinvestoinnin näkökulmasta. Molempien case-tapausten tulosten perusteella on lisäksi kartoitettu alan liiketoimintamahdollisuuksia.
Resumo:
Classic semiquantitative proteomic methods have shown that all organisms respond to a mild heat shock by an apparent massive accumulation of a small set of proteins, named heat-shock proteins (HSPs) and a concomitant slowing down in the synthesis of the other proteins. Yet unexplained, the increased levels of HSP messenger RNAs (mRNAs) may exceed 100 times the ensuing relative levels of HSP proteins. We used here high-throughput quantitative proteomics and targeted mRNA quantification to estimate in human cell cultures the mass and copy numbers of the most abundant proteins that become significantly accumulated, depleted, or unchanged during and following 4 h at 41 °C, which we define as mild heat shock. This treatment caused a minor across-the-board mass loss in many housekeeping proteins, which was matched by a mass gain in a few HSPs, predominantly cytosolic HSPCs (HSP90s) and HSPA8 (HSC70). As the mRNAs of the heat-depleted proteins were not significantly degraded and less ribosomes were recruited by excess new HSP mRNAs, the mild depletion of the many housekeeping proteins during heat shock was attributed to their slower replenishment. This differential protein expression pattern was reproduced by isothermal treatments with Hsp90 inhibitors. Unexpectedly, heat-treated cells accumulated 55 times more new molecules of HSPA8 (HSC70) than of the acknowledged heat-inducible isoform HSPA1A (HSP70), implying that when expressed as net copy number differences, rather than as mere "fold change" ratios, new biologically relevant information can be extracted from quantitative proteomic data. Raw data are available via ProteomeXchange with identifier PXD001666.
Resumo:
Työssä tutkittiin Andritz-Ahlstrom toimittamien soodakattiloiden lämmönsiirtoa ANITA 2.20- suunnitteluohjelmalla feedback- laskentaa apuna käyttäen. Data laskentaan saatiin kattiloiden takuukokeissa mitatuista arvoista. Mittaukset on suoritettiin Andritz-Ahlstromin henkilökunnan toimesta tehdashenkilökunnan avustuksella. Feedback -laskenta tapahtui mittaustulosten perusteella, joten tiettyä virhettä luonnollisesti esiintyi. Aluksi laskettiin taseet molempien ekojen yli erikseen sekä molemmat yhdessä Excel-taulukkolaskentaohjelmalla. Täältä saatiin oletettu savukaasuvirtaus kattilassa. Tämän jälkeen lämpöpintoja muokattiin todellisuutta vastaaviksi yleislikaisuuskerrointa muuttamalla (overall fouling factor). Kertoimet ovat liikkuivat noin 0.4 ja 1.6 välillä riipuen kattilan tyypistä ja ANITAn oletuksesta lämpöpintojen likaisuudelle. Havaittin että yhtä varsinaista syytä lämpöpintojen eroavaisuuteen oletetusta ei saatu. Syitä toiminnan poikkeamiseen oli monia. Mm. etukammion koolla havaittiin olevan suurtakin vaikutusta tulistimien, etenkin savukaasuvirrassa ensimmäisen tulistimen toimintaan. Yleisesti todettiin muiden tulistimien vastaavan oletettua toimintaa. Keittopinnan ja ekonomiserien toimintaa tutkittiin hivenen suppeammin ja havaittiin niiden toimivan huomattavasti stabiilimmin kuin tulistimien. Likaisuus kertoimet oletetusta vaihtelivat noin ±20 %.
Resumo:
Virtain kaupungissa sijaitseva vuodesta –79 toiminut lämpövoimala on pääasiassa kotimaisia polttoaineita käyttävä kaukolämpöä tuottava voimalaitos. Jätemurskeen (REF) osuus on tällä hetkellä noin 10 % laitoksen lämmöntuotosta. REF valmistetaan paikallisesti ja sen tuotantoa on tarkoitus lisätä lähivuosina voimakkaasti. EU:n uusi todennäköisesti loppuvuodesta-2000 hyväksyttävä jätteenpolttoa koskeva direktiivi asettaa jätteen rinnakkaispolttolaitoksille tiukat päästörajat ja mittausvelvoitteet. Tämä lisää tuntuvasti kustannuksia Virtain laitoksen kaltaisissa pienissä kierrätyspolttoainetta hyödyntävissä laitoksissa. Työssä selvitettiin jätteenpolttodirektiivistä aiheutuvat savukaasujen mittaamisen kokonaiskustannukset Virroilla. Taloudellisimman mittausjärjestelmän vuo-tuisiksi kokonaiskustannuksiksi saatiin 180 000 mk jakautuen seuraavasti: Jatkuvatoimiset mittauslaitteet käyttökuluineen 90 000 mk, jaksottaiset HF, HCl ja SO2 -mittaukset 20 000 mk, raskasmetallien, dioksiinien ja furaanien määräaikainen mittaaminen 40 000 mk ja vertailumittaukset 30 000 mk.
Resumo:
Puuenergian käyttö on viime vuosina lisääntynyt kaukolämmön tuotannossa sekä yhdistetyssä sähkön ja lämmön tuotannossa. Puun kilpailukykyä polttoaineena ovat lisänneet polttotekniikan ja korjuutekniikoiden kehittyminen. Puun energiakäyttöä on edistänyt myös valtiovalta tukien ja veroratkaisuiden avulla, koska fossiilisten polttoaineiden korvaaminen puupolttoaineilla tukee Suomen ilmastopoliittisia tavoitteita. Tämän työn tavoitteena oli selvittää puupolttoaineiden käytön mahdollisuudet Espoon Sähkön Suomenojan voimalaitoksella. Nykyiset Suomenojan pääpolttoaineet ovat kivihiili ja maakaasu. Suomenojalle toimitetut puupolttoaineet koostuisivat sahoilta saatavista sivutuotteista, metsätähdehakkeesta ja kierrätyspuusta. Puupolttoaineiden taloudellinen saatavuus vaihtelee alueittain huomattavasti. Espoo ei tässä suhteessa ole sijainniltaan edullinen. Saatujen polttoainetarjousten perusteella puunpolton kustannukset nousevat kivihiilen kustannuksia korkeammiksi kuljetusetäisyyksistä johtuen, kun puunpoltto on yli 300 GWh/a. Tämä vastaisi 10 prosenttia Espoon Sähkön vuoden 2000 kokonaispolttoainekäytöstä ja 8 prosenttia arvioidusta polttoaineiden käytöstä vuodelle 2010. Puuta voidaan polttaa leijukerrostekniikkaan perustuvissa kattiloissa, arinakattiloissa, pölypolttona tai kaasuttamalla ja johtamalla tuotekaasu poltettavaksi. Puun ravinneaineista kloori voi aiheuttaa kuumakorroosiota höyrykattiloiden tulistimissa. Tätä pyritään estämään seospoltolla rikkipitoisten polttoaineiden, kuten turpeen tai kivihiilen kanssa. Seospoltto muiden polttoaineiden kanssa parantaa myös puun palamistulosta. Puupolttoaineiden kosteus voi olla jopa 60 prosenttia. Tässä työssä tutkittiin puun energiakäytölle pääasiassa kuutta eri ratkaisua. Ne olivat: kaasuttimen rakentaminen ja tuotekaasun poltto nykyisessä hiilipölykattilassa, hiilipölykattilan muuttaminen leijukerrospolttoon, uuden vastapainevoimalaitoksen rakentaminen, Suomenojalla olevan hiilivesikattilan muuttaminen puupolttoaineille, kivihiilen ja puun yhteispoltto hiilipölykattilassa puu/hiilipölypolttimilla sekä leijukerroskattilan rakentaminen ja sen yhdistäminen olemassa olevaan höyryturbiiniin. Taloudellisesti kannattaviksi ratkaisuiksi osoittautui kaksi viimeksi mainittua. Jos voimalaitostonttia halutaan säästää myöhempää maakaasuvoimalaitoshanketta varten, nousee puun ja kivihiilen yhteispoltto puu/hiilipölypolttimilla oleellisesti paremmaksi vaih-toehdoksi. Tämän vaihtoehdon korollinen takaisinmaksuaika on 7-11 vuotta, riippuen puunpolton laajuudesta. Kannattavuudelle on hyvin tärkeää puulla tuotetun sähkön tuki. Yhteispolton ansiosta hiilipölykattilan rikkidioksidi- ja hiilidioksidipäästöt sekä mahdollisesti myös typenoksidipäästöt vähenisivät. Puunpoltto lisää savukaasuvirtaa, nostaa savukaasun loppulämpötilaa ja mahdollisesti laskee hyötysuhdetta. Laitoksen rekkaliikenne lisääntyy. Kaikki esitetyt ratkaisuvaihtoehdot vähentäisivät hiilidioksidipäästöjä. Puunpolttoratkaisuilla ei kuitenkaan pystytä vähentämään Espoon Sähkön energiantuotannon hiilidioksidipäästöjä alle vuoden 1990 tason, mutta hiilidioksidin ominaispäästöissä edellä mainitun tason alle päästäisiin.
Resumo:
Diplomityössä tarkasteltiin lentoaseman terminaalirakennuksen energia- ja ainevirtoja sekä sisäilman ominaisuuksia. Esimerkkikohteena oli Helsinki-Vantaan lentoaseman keskiterminaalirakennus, jonka 1. ja 2. rakennusvaiheen ulkovaippa muodosti taserajan. Taseen ulkopuolisista tekijöistä tarkasteltiin jäähdytysenergian tuotantoa ja ulkoilman laatua. Työn yhtenä tavoitteena oli muodostaa rakennukselle energiatase. Taseen avulla saatiin tietoa energian jakautumisesta eri toimintoihin ja löydettiin tekijät, joita suunnittelussa tulee painottaa. Terminaalin lähiympäristössä tutkittiin ulkoilman laatua mittausten avulla. Mittaustietoja käytetään apuna tulevaisuuden ilmanottosuunnittelussa. Työssä tarkasteltiin energia- ja ainevirtoina lämpö-, jäähdytys- ja sähköenergian sekä veden ostoa, tuotantoa ja kulutusta sekä prosessointia. Terminaalin lämpötarpeesta hieman yli puolet katettiin kaukolämmöllä. Loput noin 45 % lämpöenergiasta saatiin ns. ilmaisenergioista. Näistä merkittävimmäksi havaittiin sähkölaitteiden luovuttama lämpömäärä. Lämpöhäviöiden kannalta merkittäviä energiavirtoja olivat ilmanvaihdon ja vuotoilmojen kautta siirtyvät energiavirrat, joiden osuuden todettiin olevan noin 80 % terminaalin kokonaislämpöhäviöistä. Vaipan lämmöneristyskyky ja kyky absorboida auringon säteilyä todettiin hyviksi. Tulevaisuudessa tärkeitä suunnittelunäkökohtia tulevat olemaan ilmanvaihdon ja vuotoilman kautta siirtyvien energiavirtojen hallinta sekä sähköenergian ominaiskulutuksen pienentäminen. Ulkoilma todettiin mittauksin hyvätasoiseksi. Lento- ja maaliikenteen päästöarvot olivat lähellä toisiaan ja selvästi ohjearvoja alemmalla tasolla. Päästöjen sijaintiin vaikuttivat liikennemääriä enemmän tuuliolosuhteet. Tulevaisuudessa tuloilma voidaan johtaa terminaaliin yhtä hyvin joko lento- tai maaliikenteen puolelta.
Resumo:
Työn teoriaosassa esitetään kirjallisuudessa esiintyviä teoreettisia ja kokeellisia yhtälöitä nesteen nopeuden, kaasun tilavuusosuuden, painehäviön ja lämmönsiirron laskemiseksi. Lisäksi käsitellään airlift-reaktoreiden toimintaa, rakennetta ja teollisia sovelluksia, sekä sekoitusta ja geometrian vaikutusta airlift-reaktoreiden hydrodynaamisiin ominaisuuksiin. Kokeellisessa osassa kuvataan käytetty koelaitteisto ja mittausmenetelmät sekä esitetään saadut koetulokset. Koelaitteisto on viidellä nousuputkella varustettu ulkoisen kierron airlift-reaktori. Kokeellisessa osassa pyritään ratkaisemaan tällaisessa reaktorissa mahdollisesti esiintyviä ongelmia, kuten "slug flown" muodostuminen nousuputkissa sekä fluidien epätasainen jakautuminen nousuputkiin. Lisäksi tutkitaan erilaisten muuttujien, kuten kaasun tilavuusvirran, nesteen viskositeetin, suutinkoon ja nesteen jakoputken rakenteen, vaikutusta kaasun tilavuusosuuteen ja nesteen nopeuteen nousuputkissa. Nesteen nopeudet mitataan merkkiainemenetelmällä ja kaasun tilavuusosuudet manometrimenetelmällä. Lämmönsiirtoa tutkitaan mittaamalla lämpötilaeroja nousuputkissa NiCr-Ni –termoelementeillä. Mittaustulosten perusteella muokataan korrelaatiot kaasun tilavuusosuudelle ja nesteen tyhjäputkinopeudelle. Korrelaatioista lasketut tulokset sopivat kohtuullisen hyvin yhteen mitattujen tulosten kanssa. "Slug flown" ei todettu muodostuvan ongelmaksi 2.5 mPa s pienemmillä viskositeetin arvoilla 2 metriä pitkissä ja 19 mm halkaisijaltaan olevissa putkissa. Lisäksi todettiin, että kaasu- ja nestefaasien jakautumisongelmat voidaan ratkaista rakenteellisesti.