999 resultados para degradação de pastagem
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
This paper presents some results of MFI and OIT tests performed on HDPE geomembranes of 0,8 and 2,5 mm that were exposed to weathering effects and leachate after 30 months (2,5 years). The aim of this work is the evaluation of the oxidative degradation process by comparison of fresh and exposed samples results. The expositing and tests were performed according the following standards recommendations: ASTM D1435 (weathering), ASTM D5747 e D5322 (leachate), ASTM D1238 (MFI) e D3895 (OIT). The results shows, for instance, that the MFI values presented high increases on the HDPE (2.5 mm) showing that polymeric chain break occurred for both exposures and, therefore, oxidative degradation. Concerning the OIT values all the geomembranes presented very low values even in the fresh samples. This demonstrates that there wasn’t an antioxidant package appropriate for these membranes.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
The inadequate soil use is an aggravating factor of the environmental degradation and ecological unbalance. The analysis of the use and covering of the soil, by information of Remote Sensing, constitutes a technique of great usefulness to the planning and administration of the ordered occupation and rational of the physical middle, besides making possible to evaluate and to monitor the preservation of areas of natural vegetation. This work sought to evaluate the conflicts of soil use in permanent preservation areas (PPA) in Stream Comur watershed - Botucatu (SP) through Geographical Information System and satellite image of 2009. The study area is located among the geographical coordinates 48o 23’ 04” to 48o 25’ 54” of longitude WGr. and 22o 44’ 42” to 22o 48” 12” of latitude S with an area of 1,719.6 ha. The results allowed to verify that the geoprocessing techniques were of fundamental importance in the identification of the areas of soil use, of APP and of conflicts among use and PPA where it leaves of the areas of APP is being used inadequately. In terms of environmental sustainability, it can be deduced that the watershed is very unfavorable, once it presents 70.67% of area used inadequately with sugarcane and pasture.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Pós-graduação em Geografia - IGCE
Resumo:
Pós-graduação em Geografia - IGCE
Resumo:
The benzoxaxine resin is a new class of thermoset phenolic resin, which is presenting, in the lasts decades, a great application in the aircraft industry due mainly to its excellent mechanical and thermal properties. This resin associates the mechanical properties of epoxy resin with the thermal and flame retardant properties of phenolic resin. In this context, they are considered polymers of high performance and they are excellent candidates to replace the current thermoset matrices used in the processing of high performance composites. Thus, in this study nanostructured composites Benzoxazine/CNT were produced at different concentrations of functionalized and non-functionalized CNT (0,1%; 0,5% and 1,0% w/w). The thermal stability of the benzoxazine resin and its nanostructured composites was studied using thermogravimetry (TGA) and degradation kinetic model Ozawa-Wall-Flynn (O-W-F). The thermal characterization also included differential scanning calorimetry (DSC) and dynamic-mechanical analysis, infrared spectroscopy with Fourier transform (FTIR) and scanning electron microscopy (SEM).The introduction of non-functionalized CNT at low concentrations resulted in nanostructured composites with better thermal properties in relation to the neat resin. For all cases, however, the dispersion of CNT in the matrix was ineffective
Resumo:
The benzoxaxine resin is a new class of thermoset phenolic resin, which is presenting, in the lasts decades, a great application in the aircraft industry due mainly to its excellent mechanical and thermal properties. This resin associates the mechanical properties of epoxy resin with the thermal and flame retardant properties of phenolic resin. In this context, they are considered polymers of high performance and they are excellent candidates to replace the current thermoset matrices used in the processing of high performance composites. Thus, in this study nanostructured composites Benzoxazine/CNT were produced at different concentrations of functionalized and non-functionalized CNT (0,1%; 0,5% and 1,0% w/w). The thermal stability of the benzoxazine resin and its nanostructured composites was studied using thermogravimetry (TGA) and degradation kinetic model Ozawa-Wall-Flynn (O-W-F). The thermal characterization also included differential scanning calorimetry (DSC) and dynamic-mechanical analysis, infrared spectroscopy with Fourier transform (FTIR) and scanning electron microscopy (SEM).The introduction of non-functionalized CNT at low concentrations resulted in nanostructured composites with better thermal properties in relation to the neat resin. For all cases, however, the dispersion of CNT in the matrix was ineffective
Resumo:
DEVELOPMENT AND EVALUATION OF GAS DIFFUSION ELECTRODES (GDE) FOR GENERATION OF H2O2 IN SITU AND THEIR APPLICATION IN THE DEGRADATION OF REACTIVE BLUE 19 DYE. This work reports the development of GDE for electrogeneration of H2O2 and their application in the degradation process of Reactive Blue 19 dye. GDE produced by carbon black with 20% polytetrafluoroethylene generated up to 500 mg L-1 of H2O2 through the electrolysis of acidic medium at -0.8 V vs Ag/AgCl. Reactive Blue 19 dye was degraded most efficiently with H2O2 electrogenerated in the presence of Fe(II) ions, leading to removal of 95% of the original color and 39% of TOC at -0.8 V vs Ag/AgCl.
Resumo:
A matéria orgânica do solo (MOS) é responsável pela fertilidade, ciclagem de nutrientes e estabilidade da estrutura, possuindo estreita relação com a agregação do solo. No entanto, ainda não é clara a relação entre as classes de agregados na dinâmica de acúmulo ou perda de MOS em função do uso e manejo do solo. Este trabalho teve como objetivo avaliar os teores de carbono (C) em agregados do solo sob quatro usos e manejos: Cerrado nativo (CE), sistema plantio direto (SPD), sistema plantio convencional (SPC) e pastagem (PA). As áreas de estudo estão localizadas no município de Rio Verde (GO), em solo classificado como Latossolo Vermelho distrófico de textura argilosa. Em amostras de solo coletadas em fevereiro de 2007 nas camadas de 0-5, 5-10 e 10-20 cm de profundidade, foram determinados: a quantidade de macroagregados (maiores que 2,0 mm), mesoagregados (maiores que 0,25 e menores que 2,00 mm) e microagregados (maiores que 0,05 e menores que 0,25 mm) estáveis em água, os índices de agregação diâmetro médio ponderado (DMP) e geométrico (DMG) e os teores de C nas classes de agregados estabelecidas. No solo avaliado observou-se predominância de macroagregados, com maior quantidade sob CE e PA, em comparação ao solo sob SPD e SPC, indicando efeito negativo do cultivo do solo na conservação de macroagregados. Contudo, os teores de C nos agregados do solo na camada de 0-20 cm foram maiores no CE e SPD em relação a PA e SPC, sugerindo que o não revolvimento e a manutenção dos resíduos culturais na superfície do solo favorecem o acúmulo de C. Com isso, foi verificado que os macro e mesoagregados podem ser mais sensíveis ao tipo de uso e manejo do solo, quando comparados aos microagregados. A agregação do solo sob PA é semelhante à do CE, embora com menores teores de C, sugerindo dinâmica de agregação diferenciada, o que merece a atenção de novas pesquisas.
Resumo:
This work reports the development of GDE for electrogeneration of H2O2 and their application in the degradation process of Reactive Blue 19 dye. GDE produced by carbon black with 20% polytetrafluoroethylene generated up to 500 mg L-1 of H2O2 through the electrolysis of acidic medium at -0.8 V vs Ag/AgCl. Reactive Blue 19 dye was degraded most efficiently with H2O2 electrogenerated in the presence of Fe(II) ions, leading to removal of 95% of the original color and 39% of TOC at -0.8 V vs Ag/AgCl.