947 resultados para ct gel dosimetry
Resumo:
OBJETIVOS: testar a eficácia e a tolerância do gel de aroeira (Schinus terebinthifolius Raddi) para tratamento da vaginose bacteriana. MÉTODOS: quarenta e oito mulheres com vaginose bacteriana sintomática (de acordo com os critérios de Amsel) foram incluídas em ensaio clínico randomizado, duplo-cego, controlado, comparando-se o uso do gel vaginal de aroeira (25 casos) com placebo (23 casos). Os principais desfechos avaliados foram: taxa de cura, presença de lactobacilos na colpocitologia depois do tratamento e efeitos colaterais. Realizou-se análise estatística usando os testes chi2 e exato de Fisher, ao nível de significância de 5%. RESULTADOS: adotando-se os parâmetros clínicos de Amsel para vaginose bacteriana, a taxa de cura foi de 84% no grupo da aroeira e 47,8% no grupo placebo (p = 0,008). Observou-se freqüência significativamente maior de lactobacilos na colpocitologia entre as pacientes tratadas com aroeira (43,5%) em relação ao placebo (4,3%) (p = 0,002). Efeitos adversos relacionados ao tratamento não foram freqüentes em ambos os grupos. CONCLUSÕES: o presente estudo indica que o gel vaginal de aroeira é efetivo e seguro para o tratamento da vaginose bacteriana. Além disso, sugerem-se potenciais efeitos benéficos na flora vaginal.
Resumo:
Foi feita uma comparação entre os antígenos (Ag), preparados a partir dos vírus Maedi-Visna (MVV) e Artrite-encefalite Caprina (CAEV) para detecção de anticorpos contra o CAEV em 120 amostras de soro caprino. A sensibilidade e especificidade relativa da imunodifusão em ágar gel (IDAG) usando-se Ag MVV em relação ao Ag CAEV, foi 77,3% e 100%, respectivamente (X2, p<0,01). Assim, para diagnóstico de infecção pelo CAEV recomenda-se apenas o uso de Ag preparado a partir do CAEV.
Resumo:
Polymerase chain reaction (PCR) with JB1 or REP consensus oligonucleotides and pulsed field gel electrophoresis (PFGE) were used to study genomic DNA extracted from 31 strains of enterococci. Eleven ATCC strains, representative of 11 species of Enterococcus, were initially tested by JB1-PCR, revealing that Enterococcus malodoratus and Enterococcus hirae presented identical banding patterns. Eight Enterococcus faecium isolates from Stanford University and 12 from São Paulo Hospital were studied by JB1-PCR, REP-PCR 1/2R and PFGE. Among the isolates from Stanford University, 5 genotypes were defined by JB1-PCR, 7 by REP-PCR 1/2R and 4 by PFGE. Among the isolates from São Paulo Hospital, 9 genotypes were identified by JB1-PCR, 6 by REP-PCR and 5 by PFGE. The three methods identified identical genotypes, but there was not complete agreement among them.
Resumo:
The objective of this thesis was to study the effect of pulsed electric field on the preparation of TiO2 nanoparticles via sol-gel method. The literature part deals with properties of different TiO2 crystal forms, principles of photocatalysis, sol-gel method and pulsed electric field processing. It was expected that the pulsed electric field would have an influence on crystallite size, specific surface area, polymorphism and photocatalytic activity of produced particles. TiO2 samples were prepared by using different frequencies and treatment times of pulsed electric field. The properties of produced TiO2 particles were examined X-ray diffraction (XRD), Raman spectroscopy and BET surface area analysis. The photocatalytic activities of produced TiO2 particles were determined by using them as photocatalysts for the degradation of formic acid under UVA-light. The photocatalytic activities of samples produced with sol-gel method were also compared with the commercial TiO2 powder Aeroxide® (Evonic Degussa GmbH). Pulsed electric field did not have an effect on the morphology of particles. Results from XRD and Raman analysis showed that all produced TiO2 samples were pure anatase. However, pulsed electric field did have an effect on crystallite size, specific surface area and photocatalytic activity of TiO2 particles. Generally, the crystallite sizes were smaller, specific surface areas larger and initial formic acid degradation rates higher for samples that were produced by applying the pulsed electric field. The higher photocatalytic activities were attributed to larger surface areas and smaller crystallite sizes. Though, with all of the TiO2 samples produced by the sol-gel method the initial formic acid degradation rates were significantly slower than with the commercial TiO2 powder.
Resumo:
Epithelial ovarian cancer (EOC) is usually diagnosed in an advanced stage. The prognosis depends highly on the amount of the residual tumor in surgery. In patients with extensive disease, neoadjuvant chemotherapy (NACT) is used to diminish the tumor load before debulking surgery. New non-invasive methods are needed to preoperatively evaluate the disease dissemination and operability. [18F] FDG PET/CT (Positron emission tomography/computed tomography) is a promising method for cancer diagnostics and staging. The biomarker profiles during treatment can predict patient’s outcome. This prospective study included 41 EOC patients, 21 treated with primary surgery and 20 with NACT and interval surgery. The performances of preoperative contrast enhanced PET/CT (PET/ceCT) and diagnostic CT (ceCT) were compared. Perioperative visual estimation of tumor spread was studied in primary and interval surgery. The profile of the serum marker HE4 (Human epididymis 4) during primary chemotherapy was evaluated. In primary surgery, surgical findings were found to form an adequate reference standard for imaging studies. After NACT, the sensitivity for visual estimation of cancer dissemination was significantly worse. Preoperative PET/ceCT was more effective than ceCT alone in detecting extra-abdominal disease spread. The high number of supradiaphragmatic lymph node metastases detected by PET/ceCT at the time of diagnosis brings new insight in EOC spread patterns. The sensitivity of both PET/CT and ceCT remained modest in intra-abdominal areas important to operability. The HE4 profile was in concordance with the CA125 profile during primary chemotherapy. Its role in the evaluation of EOC chemotherapy response will be clarified in further studies.
Resumo:
The objective of this thesis was to study the effect of pulsed electric field on the preparation of TiO2 nanoparticles via sol-gel method under the visible light irradiation. The literature part introduces properties of different TiO2 crystal forms and principle of photocatalysis. It was expected that pulsed electric field would have an influence on degradation for oxalic acid and formic acid. TiO2 samples were prepared by using three frequencies (50Hz, 294Hz, and 963Hz) and two treatment times (12 minutes and 24 minutes) of pulsed electric field. The photocatalytic activities of TiO2 samples produced with sol-gel method were also compared with the TiO2 particles made by previous study and with the commercial TiO2 powder Aeroxide® (Evonic Degussa GmbH) at the same condition. Results show that pulsed electric field does have an effect on degradation for oxalic acid and formic acid. Generally, higher photocatalytic activities for oxalic acid and formic acid were obtained with lower frequency and longer treatment time of pulsed electric field.
Resumo:
Radiotherapy is one of the main approaches to cure prostate cancer, and its success depends on the accuracy of dose planning. A complicating factor is the presence of a metallic prosthesis in the femur and pelvis, which is becoming more common in elderly populations. The goal of this work was to perform dose measurements to check the accuracy of radiotherapy treatment planning under these complicated conditions. To accomplish this, a scale phantom of an adult pelvic region was used with alanine dosimeters inserted in the prostate region. This phantom was irradiated according to the planned treatment under the following three conditions: with two metallic prostheses in the region of the femur head, with only one prosthesis, and without any prostheses. The combined relative standard uncertainty of dose measurement by electron spin resonance (ESR)/alanine was 5.05%, whereas the combined relative standard uncertainty of the applied dose was 3.35%, resulting in a combined relative standard uncertainty of the whole process of 6.06%. The ESR dosimetry indicated that there was no difference (P>0.05, ANOVA) in dosage between the planned dose and treatments. The results are in the range of the planned dose, within the combined relative uncertainty, demonstrating that the treatment-planning system compensates for the effects caused by the presence of femur and hip metal prostheses.
Resumo:
According to the International Atomic Energy Agency (IAEA), a relatively significant number of radiological accidents have occurred in recent years mainly because of the practices referred to as potentially high-risk activities, such as radiotherapy, large irradiators and industrial radiography, especially in gammagraphy assays. In some instances, severe injuries have occurred in exposed persons due to high radiation doses. In industrial radiography, 80 cases involving a total of 120 radiation workers, 110 members of the public including 12 deaths have been recorded up to 2014. Radiological accidents in industrial practices in Brazil have mainly resulted in development of cutaneous radiation syndrome (CRS) in hands and fingers. Brazilian data include 5 serious cases related to industrial gammagraphy, affecting 7 radiation workers and 19 members of the public; however, none of them were fatal. Some methods of reconstructive dosimetry have been used to estimate the radiation dose to assist in prescribing medical treatment. The type and development of cutaneous manifestations in the exposed areas of a person is the first achievable gross dose estimation. This review article presents the state-of-the-art reconstructive dosimetry methods enabling estimation of local radiation doses and provides guidelines for medical handling of the exposed individuals. The review also presents the Chilean and Brazilian radiological accident cases to highlight the importance of reconstructive dosimetry.