934 resultados para computed tomographic scan artifact, false positive, facet subluxation
Resumo:
Nucleic acid amplification tests (NAATs) for the detection of Neisseria gonorrhoeae became available in the early 1990s. Although offering several advantages over traditional detection methods, N. gonorrhoeae NAATs do have some limitations. These include cost, risk of carryover contamination, inhibition, and inability to provide antibiotic resistance data. In addition, there are sequence-related limitations that are unique to N. gonorrhoeae NAATs. In particular, false-positive results are a major consideration. These primarily stem from the frequent horizontal genetic exchange occurring within the Neisseria genus, leading to commensal Neisseria species acquiring N. gonorrhoeae genes. Furthermore, some N. gonorrhoeae subtypes may lack specific sequences targeted by a particular NAAT. Therefore, NAAT false-negative results because of sequence variation may occur in some gonococcal populations. Overall, the N. gonorrhoeae species continues to present a considerable challenge for molecular diagnostics. The need to evaluate N. gonorrhoeae NAATs before their use in any new patient population and to educate physicians on the limitations of these tests is emphasized in this review.
Resumo:
Objective: The description and evaluation of the performance of a new real-time seizure detection algorithm in the newborn infant. Methods: The algorithm includes parallel fragmentation of EEG signal into waves; wave-feature extraction and averaging; elementary, preliminary and final detection. The algorithm detects EEG waves with heightened regularity, using wave intervals, amplitudes and shapes. The performance of the algorithm was assessed with the use of event-based and liberal and conservative time-based approaches and compared with the performance of Gotman's and Liu's algorithms. Results: The algorithm was assessed on multi-channel EEG records of 55 neonates including 17 with seizures. The algorithm showed sensitivities ranging 83-95% with positive predictive values (PPV) 48-77%. There were 2.0 false positive detections per hour. In comparison, Gotman's algorithm (with 30 s gap-closing procedure) displayed sensitivities of 45-88% and PPV 29-56%; with 7.4 false positives per hour and Liu's algorithm displayed sensitivities of 96-99%, and PPV 10-25%; with 15.7 false positives per hour. Conclusions: The wave-sequence analysis based algorithm displayed higher sensitivity, higher PPV and a substantially lower level of false positives than two previously published algorithms. Significance: The proposed algorithm provides a basis for major improvements in neonatal seizure detection and monitoring. Published by Elsevier Ireland Ltd. on behalf of International Federation of Clinical Neurophysiology.
Resumo:
Application of a computational membrane organization prediction pipeline, MemO, identified putative type II membrane proteins as proteins predicted to encode a single alpha-helical transmembrane domain (TMD) and no signal peptides. MemO was applied to RIKEN's mouse isoform protein set to identify 1436 non-overlapping genomic regions or transcriptional units (TUs), which encode exclusively type II membrane proteins. Proteins with overlapping predicted InterPro and TMDs were reviewed to discard false positive predictions resulting in a dataset comprised of 1831 transcripts in 1408 TUs. This dataset was used to develop a systematic protocol to document subcellular localization of type II membrane proteins. This approach combines mining of published literature to identify subcellular localization data and a high-throughput, polymerase chain reaction (PCR)-based approach to experimentally characterize subcellular localization. These approaches have provided localization data for 244 and 169 proteins. Type II membrane proteins are localized to all major organelle compartments; however, some biases were observed towards the early secretory pathway and punctate structures. Collectively, this study reports the subcellular localization of 26% of the defined dataset. All reported localization data are presented in the LOCATE database (http://www.locate.imb.uq.edu.au).
Resumo:
Gametic selection during fertilization or the effects of specific genotypes on the viability of embryos may cause a skewed transmission of chromosomes to surviving offspring. A recent analysis of transmission distortion in humans reported significant excess sharing among full siblings. Dizygotic (DZ) twin pairs are a special case of the simultaneous survival of two genotypes, and there have been reports of DZ pairs with excess allele sharing around the HLA locus, a candidate locus for embryo survival. We performed an allele-sharing study of 1,592 DZ twin pairs from two independent Australian cohorts, of which 1,561 pairs were informative for linkage on chromosome 6. We also analyzed allele sharing in 336 DZ twin pairs from The Netherlands. We found no evidence of excess allele sharing, either at the HLA locus or in the rest of the genome. In contrast, we found evidence of a small but significant (P = .003 for the Australian sample) genomewide deficit in the proportion of two alleles shared identical by descent among DZ twin pairs. We reconciled conflicting evidence in the literature for excess genomewide allele sharing by performing a simulation study that shows how undetected genotyping errors can lead to an apparent deficit or excess of allele sharing among sibling pairs, dependent on whether parental genotypes are known. Our results imply that gene-mapping studies based on affected sibling pairs that include DZ pairs will not suffer from false-positive results due to loci involved in embryo survival.
Resumo:
Background. Postoperative cognitive dysfunction (POCD) after coronary artery bypass graft surgery is a common complication for which, despite many clinical investigations, no definitive etiology has been found. The current use of both high and low-dose fentanyl as anesthetic techniques allowed us to investigate the effect of fentanyl on the incidence of POCD. Methods. Three hundred fifty patients scheduled to undergo elective coronary artery bypass graft surgery were randomized to receive either high-dose fentanyl (50 mu g/kg) or low-dose fentanyl (10 mu g/kg) as the basis of the anesthetic. All patients underwent neuropsychological testing before surgery and at 1 week, 3 months, and 12 months after surgery. Results. One hundred sixty-eight patients in the low-dose group and 158 patients in the high-dose group were included in the final analysis. Neuropsychological testing was performed on 88%, 93%, and 92% of patients at 1 week, 3 months, and 12 months, respectively. There was no difference between group mean scores at any of the three testing times. Analysis of individual patients by the 20% rule did not detect any differences between groups. The one SD rule, which has fewer false-positive results, detected significantly more patients with POCD in the low-dose group than in the high-dose group at 1 week (23.6% vs. 13.7%; P = 0.03) but not at the other testing times. Patients with POCD spent an average of 1.2 days longer in the hospital than those without POCD (P = 0.021). Conclusions: High-dose fentanyl is not associated with a difference in the incidence of POCD at 3 or 12 months after surgery. Low-dose fentanyl leads to shorter postoperative ventilation times and may be associated with a greater incidence of POCD 1 week after surgery. Early POCD is associated with an increased duration of stay in the hospital.
Resumo:
PTS1 proteins are peroxisomal matrix proteins that have a well conserved targeting motif at the C-terminal end. However, this motif is present in many non peroxisomal proteins as well, thus predicting peroxisomal proteins involves differentiating fake PTS1 signals from actual ones. In this paper we report on the development of an SVM classifier with a separately trained logistic output function. The model uses an input window containing 12 consecutive residues at the C-terminus and the amino acid composition of the full sequence. The final model gives a Matthews Correlation Coefficient of 0.77, representing an increase of 54% compared with the well-known PeroxiP predictor. We test the model by applying it to several proteomes of eukaryotes for which there is no evidence of a peroxisome, producing a false positive rate of 0.088%.
Resumo:
O objetivo deste estudo prospectivo foi avaliar os efeitos do aparelho Forsus® nos incisivos centrais superiores e inferiores. A amostra constituiu-se de 22 tomografias computadorizadas de 11 pacientes (sexo masculino e feminino) idade média de 15,8 anos com má oclusão de Classe II que foram tratados com o aparelho Forsus® na clínica do programa de pós-graduação em Odontologia, área de concentração Ortodontia, da Universidade Metodista de São Paulo. As tomografias foram obtidas em dois momentos T1 (final de nivelamento e antes da instalação do Forsus® e T2 (remoção do Forsus®). Para avaliar a distância do ápice até a tábua óssea, as imagens a serem examinadas foram obtidas com o auxílio do viewer do próprio i-CAT® , o iCATVision® e examinadas com o CorelDRAW X5® já para as medidas cefalométricas IMPA e 1.PP as imagens cefalométricas ortogonais foram obtidas em proporção 1:1 com auxílio do software Dolphin 3D® (Dolphin Imaging and Management Solutions, Chatsworth, EUA) e em seguida examinadas com o software Radiocef Studio 2 (Radio Memory, Belo Horizonte, Brasil). Para a obtenção do erro intra-examinador foi feito o teste t de Student pareado para o erro sistemático e a fórmula de DAHLBERG para estimar a ordem de grandeza dos erros casuais e na análise estatística dos resultados utilizou-se: o teste t para a determinação das diferenças entres as fases de observação e o teste de correlação de Pearson para avaliar a correlação entres as alterações. Observou-se: um aumento significativo (p<0,05) tanto no IMPA quanto no 1.PP, aproximação do ápice dos incisivos inferiores da tábua óssea lingual, aproximação do ápice dos incisivos superiores da tábua óssea vestibular, uma correlação negativa muito forte entre o IMPA e a distância do ápice do incisivo até a tábua óssea lingual e uma correlação negativa moderada entre 1.PP e a distância do ápice do incisivo até a tábua óssea vestibular. Sendo assim o aparelho Forsus® no tratamento da Classe II teve como efeito: vestibularização significativa dos incisivos centrais inferiores, uma verticalização significativa dos incisivos centrais superiores, aproximação do ápice dos incisivos inferiores da cortical óssea lingual e aproximação do ápice dos incisivos superiores da cortical óssea vestibular.
Resumo:
This Thesis addresses the problem of automated false-positive free detection of epileptic events by the fusion of information extracted from simultaneously recorded electro-encephalographic (EEG) and the electrocardiographic (ECG) time-series. The approach relies on a biomedical case for the coupling of the Brain and Heart systems through the central autonomic network during temporal lobe epileptic events: neurovegetative manifestations associated with temporal lobe epileptic events consist of alterations to the cardiac rhythm. From a neurophysiological perspective, epileptic episodes are characterised by a loss of complexity of the state of the brain. The description of arrhythmias, from a probabilistic perspective, observed during temporal lobe epileptic events and the description of the complexity of the state of the brain, from an information theory perspective, are integrated in a fusion-of-information framework towards temporal lobe epileptic seizure detection. The main contributions of the Thesis include the introduction of a biomedical case for the coupling of the Brain and Heart systems during temporal lobe epileptic seizures, partially reported in the clinical literature; the investigation of measures for the characterisation of ictal events from the EEG time series towards their integration in a fusion-of-knowledge framework; the probabilistic description of arrhythmias observed during temporal lobe epileptic events towards their integration in a fusion-of-knowledge framework; and the investigation of the different levels of the fusion-of-information architecture at which to perform the combination of information extracted from the EEG and ECG time-series. The performance of the method designed in the Thesis for the false-positive free automated detection of epileptic events achieved a false-positives rate of zero on the dataset of long-term recordings used in the Thesis.
Resumo:
Development of mass spectrometry techniques to detect protein oxidation, which contributes to signalling and inflammation, is important. Label-free approaches have the advantage of reduced sample manipulation, but are challenging in complex samples owing to undirected analysis of large data sets using statistical search engines. To identify oxidised proteins in biological samples, we previously developed a targeted approach involving precursor ion scanning for diagnostic MS3 ions from oxidised residues. Here, we tested this approach for other oxidations, and compared it with an alternative approach involving the use of extracted ion chromatograms (XICs) generated from high-resolution MSMS data using very narrow mass windows. This accurate mass XIC data methodology was effective at identifying nitrotyrosine, chlorotyrosine, and oxidative deamination of lysine, and for tyrosine oxidations highlighted more modified peptide species than precursor ion scanning or statistical database searches. Although some false positive peaks still occurred in the XICs, these could be identified by comparative assessment of the peak intensities. The method has the advantage that a number of different modifications can be analysed simultaneously in a single LC-MSMS run. This article is part of a Special Issue entitled: Posttranslational Protein modifications in biology and Medicine. Biological significance: The use of accurate mass extracted product ion chromatograms to detect oxidised peptides could improve the identification of oxidatively damaged proteins in inflammatory conditions. © 2013 Elsevier B.V.
Resumo:
Background: Introducing neonatal screening procedures may not be readily accepted by parents and may increase anxiety. The acceptability of pulse oximetry screening to parents has not been previously reported. Objective: To assess maternal acceptability of pulse oximetry screening for congenital heart defects and to identify factors predictive of participation in screening. Design and setting: A questionnaire was completed by a cross-sectional sample of mothers whose babies were recruited into the PulseOx Study which investigated the test accuracy of pulse oximetry screening. Participants: A total of 119 mothers of babies with false-positive (FP) results, 15 with true-positive and 679 with true-negative results following screening. Main outcome measures: Questionnaires included measures of satisfaction with screening, anxiety, depression and perceptions of test results. Results: Participants were predominantly satisfied with screening. The anxiety of mothers given FP results was not significantly higher than that of mothers given true-negative results (median score 32.7 vs 30.0, p=0.09). White British/Irish mothers were more likely to participate in screening, with a decline rate of 5%; other ethnic groups were more likely to decline with the largest increase in declining being for Black African mothers (21%, OR 4.6, 95% CI 3.8 to 5.5). White British mothers were also less anxious (p<0.001) and more satisfied (p<0.001) than those of other ethnicities Conclusions: Pulse oximetry screening was acceptable to mothers and FP results were not found to increase anxiety. Factors leading to differences in participation and satisfaction across ethnic groups need to be identified so that staff can support parents appropriately.
Resumo:
Background: Screening for congenital heart defects (CHDs) relies on antenatal ultrasound and postnatal clinical examination; however, life-threatening defects often go undetected. Objective: To determine the accuracy, acceptability and cost-effectiveness of pulse oximetry as a screening test for CHDs in newborn infants. Design: A test accuracy study determined the accuracy of pulse oximetry. Acceptability of testing to parents was evaluated through a questionnaire, and to staff through focus groups. A decision-analytic model was constructed to assess cost-effectiveness. Setting: Six UK maternity units. Participants: These were 20,055 asymptomatic newborns at = 35 weeks’ gestation, their mothers and health-care staff. Interventions: Pulse oximetry was performed prior to discharge from hospital and the results of this index test were compared with a composite reference standard (echocardiography, clinical follow-up and follow-up through interrogation of clinical databases). Main outcome measures: Detection of major CHDs – defined as causing death or requiring invasive intervention up to 12 months of age (subdivided into critical CHDs causing death or intervention before 28 days, and serious CHDs causing death or intervention between 1 and 12 months of age); acceptability of testing to parents and staff; and the cost-effectiveness in terms of cost per timely diagnosis. Results: Fifty-three of the 20,055 babies screened had a major CHD (24 critical and 29 serious), a prevalence of 2.6 per 1000 live births. Pulse oximetry had a sensitivity of 75.0% [95% confidence interval (CI) 53.3% to 90.2%] for critical cases and 49.1% (95% CI 35.1% to 63.2%) for all major CHDs. When 23 cases were excluded, in which a CHD was already suspected following antenatal ultrasound, pulse oximetry had a sensitivity of 58.3% (95% CI 27.7% to 84.8%) for critical cases (12 babies) and 28.6% (95% CI 14.6% to 46.3%) for all major CHDs (35 babies). False-positive (FP) results occurred in 1 in 119 babies (0.84%) without major CHDs (specificity 99.2%, 95% CI 99.0% to 99.3%). However, of the 169 FPs, there were six cases of significant but not major CHDs and 40 cases of respiratory or infective illness requiring medical intervention. The prevalence of major CHDs in babies with normal pulse oximetry was 1.4 (95% CI 0.9 to 2.0) per 1000 live births, as 27 babies with major CHDs (6 critical and 21 serious) were missed. Parent and staff participants were predominantly satisfied with screening, perceiving it as an important test to detect ill babies. There was no evidence that mothers given FP results were more anxious after participating than those given true-negative results, although they were less satisfied with the test. White British/Irish mothers were more likely to participate in the study, and were less anxious and more satisfied than those of other ethnicities. The incremental cost-effectiveness ratio of pulse oximetry plus clinical examination compared with examination alone is approximately £24,900 per timely diagnosis in a population in which antenatal screening for CHDs already exists. Conclusions: Pulse oximetry is a simple, safe, feasible test that is acceptable to parents and staff and adds value to existing screening. It is likely to identify cases of critical CHDs that would otherwise go undetected. It is also likely to be cost-effective given current acceptable thresholds. The detection of other pathologies, such as significant CHDs and respiratory and infective illnesses, is an additional advantage. Other pulse oximetry techniques, such as perfusion index, may enhance detection of aortic obstructive lesions.
Resumo:
Aims - A National Screening Programme for diabetic eye disease in the UK is in development. We propose a grading and early disease management protocol to detect sight-threatening diabetic retinopathy and any retinopathy, which will allow precise quality assurance at all steps while minimizing false-positive referral to the hospital eye service. Methods - Expert panel structured discussions between 2000 and 2002 with review of existing evidence and grading classifications. Proposals - Principles of the protocol include: separate grading of retinopathy and maculopathy, minimum number of steps, compatible with central monitoring, expandable for established more complex systems and for research, no lesion counting, no ‘questionable’ lesions, attempt to detect focal exudative, diffuse and ischaemic maculopathy and fast track referral from primary or secondary graders. Sight-threatening diabetic retinopathy is defined as: preproliferative retinopathy or worse, sight-threatening maculopathy and/or the presence of photocoagulation. In the centrally reported minimum data set retinopathy is graded into four levels: none (R0), background (R1), preproliferative (R2), proliferative (R3). Maculopathy and photocoagulation are graded as absent (M0, P0) or present (M1, P1). Discussion - The protocol developed by the Diabetic Retinopathy Grading and Disease Management Working Party represents a new consensus upon which national guidelines can be based leading to the introduction of quality-assured screening for people with diabetes.
Resumo:
Oxidative post-translational modifications (oxPTMs) can alter the function of proteins, and are important in the redox regulation of cell behaviour. The most informative technique to detect and locate oxPTMs within proteins is mass spectrometry (MS). However, proteomic MS data are usually searched against theoretical databases using statistical search engines, and the occurrence of unspecified or multiple modifications, or other unexpected features, can lead to failure to detect the modifications and erroneous identifications of oxPTMs. We have developed a new approach for mining data from accurate mass instruments that allows multiple modifications to be examined. Accurate mass extracted ion chromatograms (XIC) for specific reporter ions from peptides containing oxPTMs were generated from standard LC-MSMS data acquired on a rapid-scanning high-resolution mass spectrometer (ABSciex 5600 Triple TOF). The method was tested using proteins from human plasma or isolated LDL. A variety of modifications including chlorotyrosine, nitrotyrosine, kynurenine, oxidation of lysine, and oxidized phospholipid adducts were detected. For example, the use of a reporter ion at 184.074 Da/e, corresponding to phosphocholine, was used to identify for the first time intact oxidized phosphatidylcholine adducts on LDL. In all cases the modifications were confirmed by manual sequencing. ApoB-100 containing oxidized lipid adducts was detected even in healthy human samples, as well as LDL from patients with chronic kidney disease. The accurate mass XIC method gave a lower false positive rate than normal database searching using statistical search engines, and identified more oxidatively modified peptides. A major advantage was that additional modifications could be searched after data collection, and multiple modifications on a single peptide identified. The oxPTMs present on albumin and ApoB-100 have potential as indicators of oxidative damage in ageing or inflammatory diseases.
Resumo:
OBJECTIVES: Pregnancy may provide a 'teachable moment' for positive health behaviour change, as a time when women are both motivated towards health and in regular contact with health care professionals. This study aimed to investigate whether women's experiences of pregnancy indicate that they would be receptive to behaviour change during this period. DESIGN: Qualitative interview study. METHODS: Using interpretative phenomenological analysis, this study details how seven women made decisions about their physical activity and dietary behaviour during their first pregnancy. RESULTS: Two women had required fertility treatment to conceive. Their behaviour was driven by anxiety and a drive to minimize potential risks to the pregnancy. This included detailed information seeking and strict adherence to diet and physical activity recommendations. However, the majority of women described behaviour change as 'automatic', adopting a new lifestyle immediately upon discovering their pregnancy. Diet and physical activity were influenced by what these women perceived to be normal or acceptable during pregnancy (largely based on observations of others) and internal drivers, including bodily signals and a desire to retain some of their pre-pregnancy self-identity. More reasoned assessments regarding benefits for them and their baby were less prevalent and influential. CONCLUSIONS: Findings suggest that for women who conceived relatively easily, diet and physical activity behaviour during pregnancy is primarily based upon a combination of automatic judgements, physical sensations, and perceptions of what pregnant women are supposed to do. Health professionals and other credible sources appear to exert less influence. As such, pregnancy alone may not create a 'teachable moment'. Statement of contribution What is already known on this subject? Significant life events can be cues to action with relation to health behaviour change. However, much of the empirical research in this area has focused on negative health experiences such as receiving a false-positive screening result and hospitalization, and in relation to unequivocally negative behaviours such as smoking. It is often suggested that pregnancy, as a major life event, is a 'teachable moment' (TM) for lifestyle behaviour change due to an increase in motivation towards health and regular contact with health professionals. However, there is limited evidence for the utility of the TM model in predicting or promoting behaviour change. What does this study add? Two groups of women emerged from our study: the women who had experienced difficulties in conceiving and had received fertility treatment, and those who had conceived without intervention. The former group's experience of pregnancy was characterized by a sense of vulnerability and anxiety over sustaining the pregnancy which influenced every choice they made about their diet and physical activity. For the latter group, decisions about diet and physical activity were made immediately upon discovering their pregnancy, based upon a combination of automatic judgements, physical sensations, and perceptions of what is normal or 'good' for pregnancy. Among women with relatively trouble-free conception and pregnancy experiences, the necessary conditions may not be present to create a 'teachable moment'. This is due to a combination of a reliance on non-reflective decision-making, perception of low risk, and little change in affective response or self-concept.
Resumo:
We propose a novel template matching approach for the discrimination of handwritten and machine-printed text. We first pre-process the scanned document images by performing denoising, circles/lines exclusion and word-block level segmentation. We then align and match characters in a flexible sized gallery with the segmented regions, using parallelised normalised cross-correlation. The experimental results over the Pattern Recognition & Image Analysis Research Lab-Natural History Museum (PRImA-NHM) dataset show remarkably high robustness of the algorithm in classifying cluttered, occluded and noisy samples, in addition to those with significant high missing data. The algorithm, which gives 84.0% classification rate with false positive rate 0.16 over the dataset, does not require training samples and generates compelling results as opposed to the training-based approaches, which have used the same benchmark.